Browse > Article

A study on thermal fluid analysis in X-ray tube for non-fire alarm  

Yun, Dong-Min (Department of Fire Protection Engineering, Sangji University)
Jeon, Yong-Han (Department of Fire Protection Engineering, Sangji University)
Publication Information
Design & Manufacturing / v.16, no.2, 2022 , pp. 33-38 More about this Journal
Abstract
Currently, Korea is an aging society, and it is expected to enter a super-aging society in about 4 years. Accordingly, many X-ray technologies are being developed. In X-rays, 99% of X-rays are converted into heat energy and 1% into light energy (X-rays). 99% of the thermal energy raises the temperature of the anode and its surroundings, and the cooling system is an important factor as overheating can affect the deterioration of X-ray quality and shortened lifespan. There is a method of forced air cooling using natural convection. Therefore, in this study, when X-rays were taken 5 times, Flow analysis was performed on heat removal according to temperature rise and cooling time for the heat generated at the anode of the X-ray tube (input power 60kW, 75kW, 90kW). Based on one-shot, the most rapid temperature rise section increased by more than 57% to 0.03 seconds, A constant temperature rises from 0.03 seconds to 0.1 seconds, It is judged that the temperature rises by about 8.2% or more at one time. After one-shot cooling, the cooling drops sharply from about 60% to 0.03 seconds, It is judged that the temperature has cooled by more than 86% compared to the temperature before shooting. One-shot is cooled by more than 86% with cooling time after 0.1 seconds, As the input power of the anode increases, the cooling temperature gradually increases. Since the tungsten of the anode target inside the X-ray tube may be damaged by thermal shock caused by a rapid temperature rise, an improvement method for removing thermal energy is required when using a high-input power supply.
Keywords
X-ray Tube; Cooling Time; Thermal Energy;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Lee, S. M., "Thermal Characteristics of Rotating Anode X-ray Tube with Emissivity in Aging Process for Digital Radiography", Applied Science and Convergence Technology Vol. 24, No. 5, pp. 125-131, September 2015.   DOI
2 Jeon, S. O., Lee, S. J., Lee, J. C., Kim, Y. J., "Thermal-flow Analysis of the Cooling System in the Medicated Water Electrolysis Apparatus", Joural of fluid machinery, Vol. 14, No. 3, pp. 33-38, 2011.   DOI
3 Son, C. W., Seo, T. I., Kim, K. H., Lee, S. R., "Numerical Analysis of Flow Characteristies inside innes part of Fluid Control Valve System", Joumal of the Korea Academia-Industrial cooperation Society Vol. 19, No. 6, pp. 160-166, 2018.
4 Lee, S. M., "Compact Anode Design with the Heat Capacity Performance in Rotating Anode X-rat Tube for Digital Radiography", Applied Science and Convergence Technology Vol. 24, No 5, pp. 136-141, September 2015.   DOI
5 Lee, J,Y., Lee, S.P., Kim, S.W., Bae, D.S., Lee, J.K., "Characteristics of Ultrasonic Wave on Thermal Shock Damage of Tungsten", Joumal of the Korean Society for Power System Engineering, Vol. 22, No. 4, pp. 5-10, 2018.