• Title/Summary/Keyword: Aerosol removal efficiency

Search Result 51, Processing Time 0.029 seconds

An Experiment on Performance Evaluation of a Vapor Condensation Type Air Washer System for Semiconductor Clean Rooms (반도체 클린룸용 수증기 응축식 에어와셔 시스템의 성능평가)

  • Yeo, Kuk-Hyun;Park, Sang-Tae;Yoo, Kyung-Hoon;Son, Seung-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.442-447
    • /
    • 2006
  • In semiconductor manufacturing clean rooms, it becomes important to remove airborne molecular contaminants as well as particulate contaminant in outdoor air introduced into clean rooms. One suitable control technique for these chemical contaminants is air washing by water in an outdoor air handling unit. In order to enhance the removal efficiency of chemical contaminants the effect of adding a heating and humidifying process before an air washer was examined.

  • PDF

Semiempirical model for wet scrubbing of bubble rising in liquid pool of sodium-cooled fast reactor

  • Pradeep, Arjun;Sharma, Anil Kumar
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.849-853
    • /
    • 2018
  • Mechanistic calculations for wet scrubbing of aerosol/vapor from gas bubble rising in liquid pool are essential to safety of sodium-cooled fast reactor. Hence, scrubbing of volatile fission product from mixed gas bubble rising in sodium pool is presented in this study. To understand this phenomenon, a theoretical model has been setup based on classical theories of aerosol/vapor removal from bubble rising through liquid pools. The model simulates pool scrubbing of sodium iodide aerosol and cesium vapor from a rising mixed gas bubble containing xenon as the inert species. The scrubbing of aerosol and vapor are modeled based on deposition mechanisms and Fick's law of diffusion, respectively. Studies were performed to determine the effect of various key parameters on wet scrubbing. It is observed that for higher vapor diffusion coefficient in gas bubble, the scrubbing efficiency is higher. For aerosols, the cut-off size above which the scrubbing efficiency becomes significant was also determined. The study evaluates the retention capability of liquid sodium used in sodium-cooled fast reactor for its safe operation.

Removal Efficiency of Water Contents using Inertial Impaction Separator with Change in Relative Humidity (입구 습도 변화에 따른 관성 충돌 방식의 액적 분리장치의 수분제거효율 변화)

  • Song, Dong Keun;Lee, Sin Young;Hong, Won Seok;Shin, Wanho;Kim, Gyujin;Kim, Hanseok
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.247-252
    • /
    • 2013
  • Removal of water contents in a gas is needed in industrial field of gas processing related on energy production/conversion, and environmental treatment. Inertial separators are economic devices for separating droplets from the gas stream. For design and incorporation of inertial pre-treatment separator, characteristics of removal of water contents with various operation conditions are needed. In this study, removal efficiency of water droplets at various flowrates (5-14 SCMM) and relative humidity (R.H.) conditions (40%, and 90%) has been investigated. At low R.H. condition, the removal characteristic is similar to the removal of solid particles. But, droplet growth resulting from the condensation of water vapor at high R.H. condition, is significant and it made increase in removal efficiency of droplet phase of water contents. For rapid removal of water contents, an effective method to enhancing condensation growth of water droplets is highly needed.

Analysis of CA Certification Performance Test Results and Improvement of CA Test Method for a Better Differentiation of Gas Removal Performances for Room Air Cleaners (공기청정기 CA 규격성능시험 결과 분석 및 가스시험 변별력 향상 방안연구)

  • Kim, Hak-Joon;Han, Bangwoo;Kim, Yong-Jin;Cha, Sung-Il
    • Particle and aerosol research
    • /
    • v.7 no.3
    • /
    • pp.87-97
    • /
    • 2011
  • In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4 times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

Analysis of performance test results of CA-certified air cleaners from 2003 to 2015 (2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석)

  • Kim, Hak-Joon;Hong, Kee-Jung;Woo, Chang Gyu;Han, Bangwoo;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.

Removal Characteristics of $SO_2$ in the Coal Combustion Flue Gas Treatment Convergence System (석탄화력발전소 현장의 석탄연소 배가스 고도처리용 건식 분류층 반응 실증장치에서의 $SO_2$ 제거성능 특성)

  • Jeon, Seong-Min;Park, Hyung-Sang;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.239-246
    • /
    • 2013
  • The purpose of this study is to determine the feasibility of dry-type desulfurization process for actual application to coal-fired power plant. We used actual exhaust gas from Facility Y, Plant #2 to fabricate a demo-scale testing device to attempt to improve the efficiency of desulfurization. A spout-bed circulating dry scrubber convergence system connecting turbo reactor with bag filter was devised, then analyzed for performance characteristics of $SO_2$ removal for Ca/S mole ratio, superficial gas velocity, and ammonia injection, and for secondary reaction characteristics of the non-reactive sorbent at the bag filter. As a result, the installation of spout-bed circulating dry scrubber convergence system showed better economy and efficiency for removing sulfur than the existing wet/semidry-type desulfurization process. In addition, the best efficiency for desulfurization occurred when connected to the bag filter, with differential pressure maintained at 150 $mmH_2O$.

The $SO_2$ effect on NOx removal by Corona Shower System (코로나 샤워 시스템을 이용한 NOx제거에서 $SO_2$의 영향)

  • Park, Jae-Yoon;Kim, Ick-Kewn;Lee, Jae-Dong;Kim, Jong-Dal;Lee, Duck-Chool;Chang, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1794-1796
    • /
    • 1998
  • In this study, the $SO_2$ addition effect on NOx removal has been conducted from a combustion flue gases by the do corona discharge-activated radical shower systems. The simulated flue gases were consisted of NO-O_2-$N_2$, NO-$CO_2-N_2-O_2$ and $NO-SO_2-CO_2-Na-O_2$([NO]o:200ppm and $[SO_2]o$:800ppm). The injection gases used as radical source gases were $NH_3$-Ar-air. $SO_2$ and NOx removal efficiency and the other by-products were measured by Fourier Transform Infrared(FTIR) as well as $SO_2$. NOx and $NO_2$ gas detectors. By-product aerosol particles were also observed by Condensation Nucleation Particle Counter(CNPC) and SEM images after sampling. The results showed that asignificant aerosol Particle formation was observed during a removal operation in corona radical shower systems. The NOx removal efficiency significantly increased with increasing applied voltage and $NH_3$ molecule ratio. The $SO_2$ removal efficiency was not significantly effected by applied voltage and slightly increased with increasing $NH_3$ molecule ratio. The NOx removal efficiency for NO-$SO_2-CO_2-N_2-O_2$ was better than that for NO-$CO_2-N_2-O_2$.

  • PDF

Simultaneous Removal Characteristics of Particulate and Elemental Mercury in Convergence Particulate Collector (융합형여과집진장치에서의 먼지입자와 원소수은의 제거 성능 특성)

  • Park, Young Ok;Jeong, Ju Yeong
    • Particle and aerosol research
    • /
    • v.6 no.4
    • /
    • pp.173-183
    • /
    • 2010
  • The high temperature pleated filter bags which were used during this study were made of pleated nonwoven fabric of heat and acid resistant polysulfonate fibers which can withstand the heat up to $300^{\circ}C$ and have a filtration area which is 3 to 5 times larger than the conventional round filter bags. Cartridge module packed with 3 kind of the sulfur impregnated activated-carbon based sorbents were inserted in the inner of the pleated filter bag. This type of pleated filter bag was designed to remove not only the particulate matter but also the gaseous elemental mercury. The electrostatic precipitator part can enhance the particulate removal efficiency and reduce the pressure drop of the pleated filter bag by agglomerated particles to form a more porous dust layer on the surface of the pleated bag which is increased the filter bag cleaning efficiency. In addition, the most of particles are separated from the flue gas stream through the cyclone and the electrostatic precipitator part which were installed at the lower part and main body part of the convergence particulate collector, respectively. Thus reduce particulate loading of the high temperature pleated filter bags were applied in this study to analyze the removal characteristics of particulate matter and gaseous elemental mercury.

Particle removal characteristics of high-velocity electrostatic mist eliminator (정전 고속 미스트 엘리미네이터의 포집 효율 특성)

  • Kim, Jin-seon;Kim, Hak-Joon;Han, Bangwoo;Woo, Chang Gyu;Kim, Yong-Jin;Lee, Sangrin;Moon, Sangchul
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.121-133
    • /
    • 2018
  • In this study, we developed a flat-plate type wet electrostatic precipitator that generates stable corona discharge compared to wire type discharge electrode. In order to compare the particle removal efficiency according to the shape of the discharge electrode such as the variation of the horizontal and vertical distance between spiked edges, and the variation of the height of discharge pin support were tested. As a result, when the horizontal distance between spiked edges was increased up to 36 mm, the vertical distance between spiked edges was increased up to 54 mm, and the height of the discharge pin support was increased up to 76 mm, the removal efficiency of PM10 was maintained at approximate 60.0%. Furthermore, the removal efficiency of particles over $5{\mu}m$ was about 80% or more. When the flow rate was 4 m/s, the gap between collection plates was 60 mm, and -14 kV was applied to the discharge electrode. The particle removal efficiency of the flat-plate type electrostatic precipitator was maintained when the horizontal and vertical distance between spiked edges, and the height of the discharge pin support was below a certain level. Those variables may be the important design factors for the shape of the discharge electrode. Therefore, when designing the electrostatic precipitator with multiple channels, the horizontal and vertical distance between spiked edges, and the height of discharge pin support must be selected in consideration of the weight of the discharge electrode and the processing cost.

Evaluation of removal performance of a novel two-stage cylinder type cyclone against water and oil droplets (2단 실린더형 싸이클론의 물 및 오일 액적 제거 성능 분석 연구)

  • Kim, Sumin;Kim, Hak-Joon;Kim, Myungjoon;Han, Bangwoo;Woo, Chang Gyu;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.3
    • /
    • pp.119-125
    • /
    • 2017
  • A novel two stage cylindrical cyclone was developed for a 3 phase separator in shale oil production industry. The cyclone performance was compared with a cone type cyclone and multi cyclone at the same experimental condition using water and oil mists generated by a humidifier and atomizer at the flow rate 1 to $2m^3/min$. The removal efficiency of total suspended water droplets by the novel cyclone, calculated using inlet and outlet concentrations measured by an optical particle counter, was 99% which is higher than 90% of oil droplet removal efficiency at $2m^3/min$. It might be due to the evaporation of small water droplets during the tests. The water and oil droplet removal performance of the novel cyclone based on the quality factor which is a function of pressure drop and removal efficiency was the highest among three cyclones. The results indicate that the cyclone could be an economical device to remove water and oil mists from shale gas generation processes where a huge three phase separator is commonly used.