• Title/Summary/Keyword: Aerosol Particle

Search Result 666, Processing Time 0.02 seconds

Estimation of the Light Absorption Contribution for Asian Dust and Polluted Particles at Gosan, Jeju during the Asian Dust Episode in the Spring 2011 (2011년 봄 황사시기 제주도 고산에서의 황사와 오염입자의 광흡수 기여도 산정)

  • Lee, Si-Hye;Kim, Sang-Woo;Yoon, Soon-Chang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.4
    • /
    • pp.411-422
    • /
    • 2012
  • Ground-based in-situ measurements of aerosol optical properties at Gosan climate observatory have been analyzed to investigate the optical contribution of Asian dust and polluted particles on light absorption in springtime 2011. During the Asian dust episode, the contribution of Asian dust particle to aerosol absorption coefficient estimated about 45% at 370 nm and about 23% at 520 nm. Especially, black carbon in dust plume contributes about 48% to aerosol light absorption at 520 nm since the airmass are transported from the Gobi and inner Mongolia deserts, and this airmass comes across the northeastern coast of China, near the Shandong Peninsula. In pollution case, the contributions of dust particle and black carbon to aerosol absorption coefficient estimated about 41% and 11% at 370 nm, respectively. However, pollution case shows the highest light absorption of 48% for brown carbon at 370 nm, which indicates the significantly high mass concentration of organic carbon ($6.3{\pm}2.2{\mu}g\;m^{-3}$) in pollution plume can contribute to the increase of light absorption at near-UV spectral region.

Effective density measurement of ambient sub-micron aerosol using SMPS and 1 stage low-pressure impactor (SMPS와 1단 저압 임팩터를 이용한 대기 중 서브 마이크론 에어로졸 유효 밀도 측정)

  • Oh, Jaeho;Han, Jangseop;Park, Geunyoung;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.15 no.3
    • /
    • pp.115-126
    • /
    • 2019
  • In this study, a serial methodology is presented for estimating the effective density of ambient sub-micron aerosol employing lab-made 1 stage low-pressure impactor of Hyun et al. (2015) and SMPS (Scanning Mobility Particle Sizer) together. The effective density from this methodology (Impactor+SMPS) was compared with another methodology (BAM+SMPS) for estimating the effective density employing BAM (Beta-Attenuation Monitor) and SMPS. As a result, the effective density obtained with impactor+SMPS ranged from $0.42g/cm^3$ to $2.36g/cm^3$, while the effective density obtained with BAM+SMPS ranged from $1.01g/cm^3$ to $1.72g/cm^3$. The difference between these results might be caused by the particle loss in the impactor.

A Numerical Study on Particle Deposition onto a Heated Semiconductor Wafer in Vacuum Environment (진공 환경에서 가열되는 반도체 웨이퍼로의 입자 침착에 관한 수치해석적 연구)

  • Park, Su-Bin;Yoo, Kyung-Hoon;Lee, Kun-Hyung
    • Particle and aerosol research
    • /
    • v.14 no.2
    • /
    • pp.41-47
    • /
    • 2018
  • Numerical analysis was conducted to characterize particle deposition onto a heated horizontal semiconductor wafer in vacuum environment. In order to calculate the properties of gas surrounding the wafer, the gas was assumed to obey the ideal gas law. Particle transport mechanisms considered in the present study were convection, Brownian diffusion, gravitational settling and thermophoresis. Averaged particle deposition velocities on the upper surface of the wafer were calculated with respect to particle size, based on the numerical results from the particle concentration equation in the Eulerian frame of reference. The deposition velocities were obtained for system pressures of 1000 Pa~1 atm, wafer heating of 0~5 K and particle sizes of $2{\sim}10^4nm$. The present numerical results showed good agreement with the available experimental ones.

MODIS-estimated Microphysical Properties of Clouds Developed in the Presence of Biomass Burning Aerosols (MODIS 관측자료를 이용한 러시아 산불 영향 하에 발달한 구름의 미세 물리적 특성 연구)

  • Kim, Shin-Young;Sohn, Byung-Ju
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.4
    • /
    • pp.289-298
    • /
    • 2008
  • An algorithm was developed to retrieve both cloud optical thickness and effective particle radius considered the aerosol effect on clouds. This study apply the algorithm of Nakajima and Nakajima (1995) that is used to retrieve cloud optical thickness and effective particle radius from visible, near infrared satellite spectral measurements. To retrieve cloud properties, Look-up table (LUT) was made under different atmospheric conditions by using a radiative transfer model. Especially the vertical distribution of aerosol is based on a tropospheric aerosol profile in radiative transfer model. In the case study, we selected the extensive forest fire occurred in Russia in May 2003. The aerosol released from this fire may be transported to Korea. Cloud properties obtained from these distinct atmospheric situations are analysed in terms of their possible changes due to the interactions of the clouds with the aerosol particle plumes. Cloud properties over the East sea at this time was retrieved using new algorithm. The algorithm is applied to measurements from the MODerate Resolution Imaging Spectrometer (MODIS) onboard the Terra spacecrafts. As a result, cloud effective particle radius was decreased and cloud optical thickness was increased during aerosol event. Specially, cloud effective particle radius is hardly greater than $20{\mu}m$ when aerosol particles were present over the East Sea. Clouds developing in the aerosol event tend to have more numerous but smaller droplets.

Continuous Measurements of Size Separated Atmospheric Aerosol Number Concentration in Background Area (대기배경지역 에어로졸의 입경별 수농도 연속 측정)

  • Kang, Chang-Hee;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.21 no.4
    • /
    • pp.535-543
    • /
    • 2012
  • The aerosol number concentration have measured with an aerodynamic particle sizer spectrometer(APS) at Gosan site, which is known as background area in Korea, from January to September 2011. The temporal variation and the size distribution of aerosol number concentration have been investigated. The entire averaged aerosol number concentration in the size range 0.25~32.0 ${\mu}m$ is about 252 particles/$cm^3$. The number concentration in small size ranges(${\leq}0.5{\mu}m$) are very higher than those in large size ranges, such as, the number concentration in range of larger than 6.5 ${\mu}m$ are almost zero particles/$cm^3$. The contributions of the number concentration to PM10 and/or PM2.5 are about 34%, 20.1% and 20.4% in the size range 0.25~0.28 ${\mu}m$, 0.28~0.30 ${\mu}m$ and 0.30~0.35 ${\mu}m$, respectively, however, the contributions are below 1% in range of larger than 0.58 ${\mu}m$. The monthly variations in the number concentration in smaller size range(<1.0 ${\mu}m$) are evidently different from the variations in range of larger than 1.0 ${\mu}m$, but the variations are appeared similar patterns in smaller size range(<1.0 ${\mu}m$), also the variations in range of larger than 1.0 ${\mu}m$ are similar too. The diurnal variations in the number concentration for smaller particle(<1.0 ${\mu}m$) are not much, but the variations for larger particle are very evident. Size-fractioned aerosol number concentrations are dramatically decreased with increased particle size. The monthly differences in the size-fractioned number concentrations for smaller size range(<0.7 ${\mu}m$) are not observed, however, the remarkable monthly differences are observed for larger size than 0.7 ${\mu}m$.

Features on the Vertical Size Distribution of Aerosols using Ballon-borne Optical Particle Counter at Anmyeon (광학입자계수기를 이용한 안면도 연직 에어러솔 수농도 크기 분포 특성)

  • Choi, B.C.;Iwasaka, Y.;Lim, J.C.;Jeong, S.B.;Kim, Y.S.;Dmitri, T.;Nagatani, T.;Yamada, M.;Kim, S.B.;Hong, G.M.;Lee, Y.G.;Yoo, H.J.
    • Atmosphere
    • /
    • v.15 no.3
    • /
    • pp.149-153
    • /
    • 2005
  • A balloon-borne Optical Particle Counter (hereafter "OPC Sonde"), which was developed by the atmospheric research group of Nagoya University, is used for getting the information of vertical profile of particle size and concentration in Anmyeon ($36^{\circ}32^{\prime}N$ $126^{\circ}19^{\prime}E$) on 18 March 2005. A range of five different particle sizes is shown in the vertical profile of aerosol number density estimated from the OPC Sonde. It was found that small size particles have vertically larger aerosol number density than relatively big ones. For all size ranges the vertical aerosol number density shows a decreased pattern as the altitude becomes higher. The aerosol number density of $0.3{\sim}0.5{\mu}m$, $0.5{\sim}0.8{\mu}m$, $0.8{\sim}1.2{\mu}m$ size ranges at the 10km height, which is the tropopause approximately, are $1,000,000ea/m^3$, $100,000ea/m^3$, $10,000ea/m^3$ respectively. The data of OPC Sonde are also compared with the data of PM10 $\beta$-ray) and Micro Pulse Lidar which are operating at Korea Global Atmosphere Watch Observatory in Anmyeon.

A Study on the Characteristics Analysis of Cutting Fluid Aerosol Using Dual-PDA System - for Turning Process (Dual-PDA를 이용한 절삭유 에어로졸 특성분석에 관한 연구(I) -선삭공정을 중심으로)

  • Jeong, J.Y.;Hwang, D.C.;Hong, G.B.;Woo, C.K.;Hwang, J.
    • Journal of ILASS-Korea
    • /
    • v.10 no.2
    • /
    • pp.10-17
    • /
    • 2005
  • The proposed research has been performed to know the characteristics of cutting fluid aerosol formation using Dual-PDA system in machining process. The cutting fluid aerosol size and concentration is common attributes that quantify the environmental intrusiveness or air quality contamination. The atomized cutting fluid aerosols can be affected to human health risk such as lung cancer and skin irritations. Even though cutting fluid can be improved the machining quality and productivity in a carefully. its use must be controlled and optimized carefully. This experimental works using Dual-PDA were performed to analyze the cutting fluid aerosol behaviors and characteristics in turning process using precise aerosol particle measuring system. The obtained experimental results profovide basic knowledge to develop the environmentally conscious machining process. This results cail be provided as a basis to estimate and control the hazardous cutting fluid aerosol in machining process.

  • PDF

Investigation of the Optical and Cloud Forming Properties of Pollution, Biomass Burning, and Mineral Dust Aerosol

  • Lee Yong-Seop
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2006.04a
    • /
    • pp.55-56
    • /
    • 2006
  • This thesis describes the use of measured aerosol size distributions and size-resolved hygroscopic growth to examine the physical and chemical properties of several particle classes. The primary objective of this work was to investigate the optical and cloud forming properties of a range of ambient aerosol types measured in a number of different locations. The tool used for most of these analyses is a differential mobility analyzer / tandem differential mobility analyzer (DMA / TDMA) system developed in our research group. To collect the data described in two of the chapters of this thesis, an aircraft-based version of the DMA / TDMA was deployed to Japan and California. The data described in two other chapters were conveniently collected during a period when the aerosol of interest came to us. The unique aspect of this analysis is the use of these data to isolate the size distributions of distinct aerosol types in order to quantify their optical and cloud forming properties. I used collected data during the Asian Aerosol Characterization Experiment (ACE-Asia) to examine the composition and homogeneity of a complex aerosol generated in the deserts and urban regions of China and other Asian countries. An aircraft-based tandem differential mobility analyzer was used for the first time during this campaign to examine the size-resolved hygroscopic properties of particles having diameters between 40 and 586 nm. Asian Dust Above Monterey (ADAM-2003) study was designed both to evaluate the degree to which models can predict the long-range transport of Asian dust, and to examine the physical and optical properties of that aged dust upon reaching the California coast. Aerosol size distributions and hygroscopic growth are measured in College Station, TX to investigate the cloud nucleating and optical properties of a biomass burning aerosol generated from fires on the Yucatan Peninsula. Measured aerosol size distributions and size-resolved hygroscopicity and volatility were used to infer critical supersaturation distributions of the distinct particle types that were observed during this period. The predicted CCN concentrations were used in a cloud model to determine the impact of the different aerosol types on the expected cloud droplet concentration. RH-dependent aerosol extinction coefficients are calculated at a wavelength of 550 nm.

  • PDF

Size Distribution Characteristics of Particulate Matter Emitted from Cooking (조리과정에서 생성된 미세먼지의 크기분포 특성)

  • Joo, Sang-Woo;Ji, Jun-Ho
    • Particle and aerosol research
    • /
    • v.16 no.1
    • /
    • pp.9-17
    • /
    • 2020
  • The characteristics of particulate matter made from daily cooking at a Korean residential apartment house with three dwellers had been investigated for about 3 months. All data were recorded by an optical particle counter every minute at the kitchen. Types of cooking such as boiling, frying, and grilling that performed in the house were listed. Boiling only was used in 32% cases among total 234 meals. Frying and grilling were 14% and 11%, respectively. From an initial indoor particulate matter smaller than 10 ㎛ in diameter, the increases due to cooking are reported by size. In case of boiling, PM at 1-10 ㎛ size and under 1 ㎛ size little increased. Normally, particles from oil or combustion in a process of frying or grilling increased indoor PM. In a case of grilling, particle mass concentration in a region of 1-10 ㎛ in diameter increased as much as 295 ㎍/㎥. Mass concentration of particles smaller than 1 ㎛ increased as much as 33 ㎍/㎥.

Performance Evaluation of Gas Cleaning Industrial Filters using a Bi-Modal Test Aerosol for Dust Loading Studies

  • Lee, Jae-Keun;Kim, Seong-Chan;Benjamin Y.H. Liu
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.131-137
    • /
    • 1996
  • Typical size distribution of emission particulates is bi-modal in shape with particles in the fine mode (< 2.0 $\mu\textrm{m}$) and the coarse mode. An experimental study of pressure drop across the industrial gas cleaning filters has been conducted using particle mixture of fine alumina and coarse Arizona dusts with a rotating aerosol disperser to generate the bi-modal test aerosol. Pressure drop increased linearly with increasing mass loading. The pressure drop was found to be strongly dependent upon the mass ratio of fine to coarse particles. The smaller the mass ratio of fine to coarse particles and the higher face velocity are, the faster pressure drop rises. The fine particles and the greater inertia of the particle moving fast would cause a denser cake formation on the filter surface, resulting in a greater specific resistance to the gas flow.

  • PDF