• Title/Summary/Keyword: Aerodynamic diameter

검색결과 163건 처리시간 0.023초

500 W 급 마이크로 가스터빈 제너레이터용 환형 연소기의 특성에 관한 연구 (Study on the Characteristics of an Annular Combustor for a 500 W Class Micro Gas Turbine Generator)

  • 도규형;김태훈;한용식;김명배;최병일
    • 한국연소학회지
    • /
    • 제19권4호
    • /
    • pp.14-20
    • /
    • 2014
  • In the present study, an annular combustor for a 500 W class micro gas turbine generator was designed and its characteristics were investigated by using both numerical and experimental methods. For this purpose, geometrical configurations of the annular combustor were determined in the aspect of the aerodynamic and chemical consideration. Also, fluid flow and pressure drop characteristics in the combustor were numerically studied by using commercial tool, FLUENT. Based on the numerical results, the diameter and the angle of air admission holes in the primary zone were chosen to be 2.5 mm and $30^{\circ}$, respectively. Finally, an integrated test unit, which consisted of a compressor, combustor, turbine, and motor/generator, was developed in order to measure the combustor efficiency. As the temperature difference between the combustor inlet and the turbine inlet or the air mass flow rate increased, the combustor efficiency increased and it was over 90% when the air mass flow rate was larger than 7.30 g/s. It was shown that the annular combustor developed in this study met the design requirement for a 500 W class micro gas turbine generator.

Effects of Spray Surfactant and Particle Charge on Respirable Coal Dust Capture

  • Tessum, Mei W.;Raynor, Peter C.
    • Safety and Health at Work
    • /
    • 제8권3호
    • /
    • pp.296-305
    • /
    • 2017
  • Background: Surfactant-containing water sprays are commonly used in coal mines to collect dust. This study investigates the dust collection performance of different surfactant types for a range of coal dust particle sizes and charges. Methods: Bituminous coal dust aerosol was generated in a wind tunnel. The charge of the aerosol was either left unaltered, charge-neutralized with a neutralizer, or positively- or negatively-charged using a diffusion charger after the particles were neutralized. An anionic, cationic, or nonionic surfactant spray or a plain water spray was used to remove the particles from the air flow. Some particles were captured while passing through spray section, whereas remaining particles were charge-separated using an electrostatic classifier. Particle size and concentration of the charge-separated particles were measured using an aerodynamic particle sizer. Measurements were made with the spray on and off to calculate overall collection efficiencies (integrated across all charge levels) and efficiencies of particles with specific charge levels. Results: The diameter of the tested coal dust aerosol was $0.89{\mu}m{\pm}1.45$ [geometric $mean{\pm}geometric$ standard deviations (SD)]. Respirable particle mass was collected with $75.5{\pm}5.9%$ ($mean{\pm}SD$) efficiency overall. Collection efficiency was correlated with particle size. Surfactant type significantly impacted collection efficiency: charged particle collection by nonionic surfactant sprays was greater than or equal to collection by other sprays, especially for weakly-charged aerosols. Particle charge strength was significantly correlated with collection efficiency. Conclusion: Surfactant type affects charged particle spray collection efficiency. Nonionic surfactant sprays performed well in coal dust capture in many of the tested conditions.

증기터빈 저압 L-1단 블레이드-디스크 연성 진동 특성 분석 (Vibration Analysis for the L-1 Stage Bladed-disk of a LP Steam Turbine)

  • 이두영;배용채;김희수;이욱륜;김두영
    • 한국소음진동공학회논문집
    • /
    • 제20권1호
    • /
    • pp.29-35
    • /
    • 2010
  • This paper studies causes of the L-1 blade damage of a low pressure turbine, which was found during the scheduled maintenance, in 500 MW fossil power plants. Many failures of turbine blades are caused by the coupling of aerodynamic forcing with bladed-disk vibration characteristics. In this study the coupled vibration characteristics of the L-1 turbine bladed-disk in a fossil power plant is shown for the purpose of identifying the root cause of the damage and confirming equipment integrity. First, analytic and experimental modal analysis for the bladed-disk at zero rpm as well as a single blade were performed and analyzed in order to verify the finite element model, and then steady stresses, natural frequencies and corresponding mode shapes, dynamic stresses were calculated for the bladed-disk under operation. Centrifugal force and steady steam force were considered in calculation of steady and dynamic stress. The proximity of modes to sources of excitation was assessed by means of an interference diagram to examine resonances. In addition, fatigue analysis was done for the dangerous modes of operation by a local strain approach. It is expected that these dynamic characteristics will be used effectively to identify the root causes of blade failures and to perform prompt maintenance.

Spatial analysis of $PM_{10}$ and cardiovascular mortality in the Seoul metropolitan area

  • Lim, Yu-Ra;Bae, Hyun-Joo;Lim, Youn-Hee;Yu, Seungdo;Kim, Geun-Bae;Cho, Yong-Sung
    • Environmental Analysis Health and Toxicology
    • /
    • 제29권
    • /
    • pp.5.1-5.7
    • /
    • 2014
  • Objectives Numerous studies have revealed the adverse health effects of acute and chronic exposure to particulate matter less than $10{\mu}m$ in aerodynamic diameter ($PM_{10}$). The aim of the present study was to examine the spatial distribution of $PM_{10}$ concentrations and cardiovascular mortality and to investigate the spatial correlation between $PM_{10}$ and cardiovascular mortality using spatial scan statistic (SaTScan) and a regression model. Methods From 2008 to 2010, the spatial distribution of $PM_{10}$ in the Seoul metropolitan area was examined via kriging. In addition, a group of cardiovascular mortality cases was analyzed using SaTScan-based cluster exploration. Geographically weighted regression (GWR) was applied to investigate the correlation between $PM_{10}$ concentrations and cardiovascular mortality. Results An examination of the regional distribution of the cardiovascular mortality was higher in provincial districts (gu) belonging to Incheon and the northern part of Gyeonggi-do than in other regions. In a comparison of $PM_{10}$ concentrations and mortality cluster (MC) regions, all those belonging to MC 1 and MC 2 were found to belong to particulate matter (PM) 1 and PM 2 with high concentrations of air pollutants. In addition, the GWR showed that $PM_{10}$ has a statistically significant relation to cardiovascular mortality. Conclusions To investigate the relation between air pollution and health impact, spatial analyses can be utilized based on kriging, cluster exploration, and GWR for a more systematic and quantitative analysis. It has been proven that cardiovascular mortality is spatially related to the concentration of $PM_{10}$.

X-선 형광분광법을 이용한 대기부유분진중 중금속의 농도분포에 관한 연구 (Studies on the Distribution of Heavy Metal Concentrations in Ambient Suspended Particulate Matters Using the X-ray Fluorescence Spectroscopy)

  • 이태정;김동술
    • 한국대기환경학회지
    • /
    • 제8권1호
    • /
    • pp.20-28
    • /
    • 1992
  • The x-ray fluorescence(XRF) is one of the most convenient and widely used techniques for analyzing trace elements in ambient particulate matters. The objects of the study were to estimate the optimum exposure time using the XRF, to investigate the distributions of heavy metal levels in particulate matters, and finally to study seasonal variation for the concentrations of total suspended particulate matters(TSP) and size fractionated particulate matters. The suspended particulate matters had been collected by a cascade impactor having 9 size fragnated stages for 3 years(Dec. 1988 to Nov. 1991) in Kyung Hee University-Suwon Campus. The particulate matters were then collected on each stage by membrane filters. The weight concentrations were determined by the XRF system. Thus, seasonal variations and relationship between concentration and particle size could be investigated. Resulting distribution was bimodal with the coarse and the fine particle groups minimum occurring around 2.1 to 3.3 $\mu$m as an aerodynamic diameter. To determine optimum exposure time of the XRF for various trace inorganic elements, membrane filters and the NIST standard filters were extensively studied. Using a statistical technique, optimum exposure time was estimated for each trace element and overall elements. The time was then determined as 20 seconds for the XRF system. The concentration of TSP was 123.9$\mum/m^3$ on an arithmatic average. The levels of each inorganic metal were Si 2420.0ng/$m^3$, Fe 977.1ng/$m^3$, and so on. The Pb. Zn, and Cu abounded in the fine mode group, while Ca, Fe, Si, Al, and K in the coarse group. Marked seasonal variation of TSP and metal concentrations was observed. The concentration of heavy metals in the fine mode was highest in winter : on the other hand, that in the coarse mode was highest in spring.

  • PDF

다단 마이크로터빈에서 단수 변화에 따른 터빈의 성능에 관한 실험적연구 (An Experimental Study of the Performance Characteristics on a Multi-Stage Micro Turbine with Various Stages)

  • 조종현;조수용;최상규
    • 한국항공우주학회지
    • /
    • 제33권12호
    • /
    • pp.76-82
    • /
    • 2005
  • 본 연구에서는 축류형 마이크로터빈의 단 수를 단 단에서부터 최대 6단까지 변경하면서 각 단에서의 공력특성을 측정하였다. 실험에 사용된 마이크로터빈은 터빈입구에서 유량계수가 2.0, 부하계수가 3.25이며 유로의 평균직경이 25.8mm인 소형 축류형 다단터빈이 적용되었다. 정익과 동익의 솔리디티는 0.67~0.75 범위의 값이 적용되었으며 입구에 일정한 질유량과 전압력으로 조정한 후에 터빈의 부하를 변경하면서 탈설계 영역에서의 공력특성을 측정하였다. 본 실험에서는 단 당 최대 2kW/kg/sec의 비출력이 얻어졌으나 단수의 증가에 따라 비출력의 증가폭은 다소 완화되었으며, 토오크의 경우는 단수가 증가되면서 낮은 회전수 영역에서는 토오크의 증가폭이 일정하나 높은 회전수영역에서는 토오크의 증가폭이 둔화되었다. 블레이드의 높이에 비하여 팁간격의 영향이 크므로 터빈의 효율은 낮으나 단 수의 증가에 따라 증가가 가능하다.

서울시 대기 중 미세먼지 내 탄소성 입자의 농도 및 특성 : 2006~2007년 측정결과 (Concentrations and Characteristics of Carbonaceous Compounds in PM10 over Seoul: Measurement between 2006 and 2007)

  • 최나래;이지이;정창훈;이선영;이승묵;김용표
    • 한국대기환경학회지
    • /
    • 제31권4호
    • /
    • pp.345-355
    • /
    • 2015
  • Carbonaceous compounds in the atmospheric particulate matter with an aerodynamic diameter of less than or equal to a nominal $10{\mu}m$ ($PM_{10}$) were analyzed for the samples collected during the period of August 2006 to August 2007 at Jongro in Seoul. A total 18 dicarboxylic acids (DCAs) and levoglucosan, as well as organic carbon (OC), elemental carbon (EC), and water soluble organic carbon (WSOC), were analyzed. Distinctive seasonal patterns of the concentrations of OC, EC, and WSOC including levoglucosan were observed with the highest concentrations in winter and the lowest concentrations in summer. In addition, OC, WSOC, and most of DCAs showed also higher concentration in summer than in winter. Using the seasonal patterns and relevant indicative ratios (WSOC/EC and $OC_{sec}/OC_{tot}$) of the carbonaceous compounds, it was verified that (1) primary emission sources were elevated in winter, and (2) the formation of secondary OC increased due to the prompted photochemical reaction in summer. Results from this study also suggest that some organic compounds were likely attributed to longrange transport.

샘플유량과 기상조건에 따른 미세먼지 중량 측정용 기구간의 농도 비교 (Comparative Evaluation of Gravimetric Measurement Samplers for Fine Particles by Sampling Flow Rates and Meteorological Conditions)

  • 양원호;김대원;김진국;윤충식;허용;이부용
    • 한국환경과학회지
    • /
    • 제14권1호
    • /
    • pp.91-96
    • /
    • 2005
  • Several samplers using gravimetric methods such as high-volume air sampler, MiniVol portable sampler, personal environmental monitor(PEM) and cyclone were applied to determine the concentrations of fine particles in atmospheric condition. Comparative evaluation between high-volume air sampler and Minivol portable sampler for $PM_{10}$, and between Minivol portable sampler and PEM was undertaken from June, 2003 to January 2004. Simultaneously, meteorological conditions such as wind speed, wind direction, relative humidity and temperature was measured to check the factors affecting the concentrations of fine particles. In addition, particle concen­trations by cyclone with an aerodynamic diameter of $4{\mu}m$ were measured. Correlation coefficient between high­volume air sampler and portable air sampler for $PM_{10}$ was 0.79 (p<0.001). However, the mean concentration for $PM_{10}$ by high-volume air sampler was significantly higher than that by Minivol portable sampler (p=0.018). Correlation coefficient between Minivol portable sampler and PEM for $PM_{2.5}$ as 0.74 (p<0.001), and the measured mean concentrations for $PM_{2.5}$ did not show significant difference. Difference of the measured con­centrations of fine particle might be explained by wind speed and humidity among meteorological conditions. Particle concentration differences by measurement samplers were proportional to the wind speed, but inversely proportional to the relative humidity, though it was not a significant correlation.

부산지역의 미세먼지 중 중금속 및 이온성분과 선박배출가스의 영향에 관한 연구 (A Study on the Metallic and Ion Elements by Fine Particle and Effects of Vessels Exhaust Emission in Busan City)

  • 이승원;손이슬;김정권
    • 한국환경과학회지
    • /
    • 제20권1호
    • /
    • pp.147-153
    • /
    • 2011
  • The objectives of this study were to investigate the seasonal characteristics of metallic and ion elements of $PM_{10}$(Particulate matter with aerodynamic diameter ${\leq}10\;{\mu}m$) and the effects of vessels exhaust emission from ships harboring in Busan City. The $PM_{10}$ samples were collected from January 2010 to October 2010 at Dongsam-dong(coastal area), in Busan City. The particulate matters were analyzed for major water soluble ionic components and metals. The ranges of the $PM_{10}$ mass concentrations were from 29.8 ${\mu}g/m^3$ to 47.0 ${\mu}g/m^3$ in Dongsam-dong. The $PM_{10}$ mass concentrations in Dongsam-dong are very similar to Gwangbok-dong during same sampling periods. These results were understood by the effects of the shipping source emitted from ships anchoraging and running. The concentrations of water-soluble ions and metals in the $PM_{10}$ had a level of as high as the order of $SO_4^{2-}$>$NO_3^-$>$Cl^-$ and $NH_4^+$>$Na^+$>$Ca^{2+}$>$K^+$>$Mg^{2+}$, respectively. The correlation coefficients($R^2$) for $SO_4^{2-}/PM_{10}$ and $NH_4^+/PM_{10}$ of were 0.7446 and 0.7784, respectively, and it showed the high correlation with each other.

500W 급 다리우스형 풍력발전기의 최적설계를 위한 수치적 연구 (Numerical study to Determine Optimal Design of 500W Darrieus-type Vertical Axis Wind Turbine)

  • 이영태;임희창
    • 대한기계학회논문집B
    • /
    • 제39권8호
    • /
    • pp.693-702
    • /
    • 2015
  • 본 논문은 NACA 익형의 블레이드를 가지는 다리우스 수직축 풍력발전기(VAWT)의 성능특성에 대한 연구이다. 다양한 설계변수를 이용한 다리우스 VAWT 의 최적 형상을 예측하기 위해서 블레이드 근처에서 나타나는 공력특성 및 박리유동, 유동과 블레이드 간의 상호작용, 이로 인해 유도되는 토크 및 출력특성 등을 분석하였다. 블레이드의 최적 형상 설계 및 주변 유동과의 상호작용 특성을 보기 위하여 다양한 인자들 (즉, 코드길이, 로터직경, 피치각, 블레이드의 두께비 및 비틀림각 등)을 고려하였다. 본 연구에서 연구결과로는 TSR 가 낮은 영역에서는 솔리디티가 큰 로터가 높은 출력계수를 가지는 반면, TSR 이 높은 영역에서는 솔리디티가 작은 로터가 높은 출력계수를 가진다. 블레이드의 익형이 안쪽으로 향하는 피치각은 $-2^{\circ}$와 비틀림각이 $0^{\circ}$ 일 때, 다리우스형 VAWT 가 최대 출력을 발생하였다.