• 제목/요약/키워드: Advanced treatment

검색결과 4,471건 처리시간 0.039초

실험실 규모 크립토스포리디움의 불활성화 실험을 통한 오존 고도정수처리 정수장에서 소독 효과 예측 (Prediction of Cryptosporidium parvum Inactivation in Advanced Ozone Drinking Water Treatment with Lab Scale Experiments)

  • 조민;정현미;김이호;손진식;박상정;윤제용
    • 한국물환경학회지
    • /
    • 제21권1호
    • /
    • pp.7-13
    • /
    • 2005
  • With the appearance of pathogenic microorganisms, which were resistant to free chlorine, the significant attention to the necessity of powerful alternative disinfection methods such as ozone, chlorine dioxide, LTV irradiation to inactivating pathogens has been increased in water treatment. Among these alternative disinfection methods, ozone is well known as strong biocidal method and the usage of ozone is also increasing in Korea. However, in Korea, there has been no report on the quantitative study of Cryptosporidium parvum with ozone and its evaluation in advanced drinking water treatments. This study reports on the methodology for predicting the ozone inactivation of Cryptosporidium parvum by ozone disinfection in advanced drinking water treatment. The method is based on the fact that a specific inactivation level of microorganisms is achieved at a unique value of ozone exposures, independent of ozone dose and type of water, and quantitatively described by a delayed Chick-Watson model. The required values ${\bar{C}}T$ for 2 log inactivation of Cryptosporidium parvum was $6.0mg/L{\cdot}min$ and $15.5mg/L{\cdot}min$ at $20^{\circ}C$ and $5^{\circ}C$, respectively. From this obtained Cryptosporidium parvum inactivation curves and calculated ${\bar{C}}T$ values of advanced drinking water treatment water in Korea with FIA (Flow injection alaysis), we can predict that water treatment plant can achieve a 1.1~1.8 log inactivation and 0~0.4 log inactivation at $20^{\circ}C$ and $5^{\circ}C$, respectively. This methodology will be useful for drinking water treatment plants which intend to evaluate the disinfection efficiencies of their ozonation process without full scale test and direct experiments with Cryptosporidium parvum.

Emergy를 이용한 오염물질 저감시설의 환경 비용/편익 분석 (Environmental Cost and Benefit Analysis Pollutant Reduction Facilities of the using the Emergy)

  • 김진이;황하선;김상수;이재관
    • 한국물환경학회지
    • /
    • 제29권5호
    • /
    • pp.591-597
    • /
    • 2013
  • The input emergy of an advanced treatment plant for reducing the 1 kg of TN and TP was estimated 4.14E+14 sej/kg, 5.02E+15 sej/kg, respectively. In addition, the input emergy of constructed wetland for reduction of the 1 kg of TN and TP reduction was estimated to be 2.48E+14 sej/kg, 3.38E+15 sej/kg, respectively. The cost reducing 1 kg of TN and TP for an advanced treatment plant was estimated 197,466 won and 2,388,739 won respectively and constructed wetland was estimated 117,976 won and 1,609,213 won respectively. As a result, All of the emergy source of constructed wetland for reducing non-point source is renewable resource. If we use the constructed wetland, it results in enhancing economic value by reducing of non-point pollution, controlling a flood and providing the habitat of animals or plants. Improving water quality program in the Nakdong River Basin should be changed into an ecological treatment facilities from expansion of the sewage treatment facilities and advanced treatment plant using high cost and non-renewable energies.

Ti/Al/STS 클래드재의 접합특성에 미치는 예비 열처리의 영향 (Effect of Pre-Heat Treatment on Bonding Properties in Ti/Al/STS Clad Materials)

  • 배동현;정수정;조영래;정원섭;정호신;강창룡;배동수
    • 대한금속재료학회지
    • /
    • 제47권9호
    • /
    • pp.573-579
    • /
    • 2009
  • Titanium/aluminum/stainless steel(Ti/Al/STS) clad materials have received much attention due to their high specific strength and corrosion-resisting properties. However, it is difficult to fabricate these materials, because titanium oxide is easily formed on the titanium surface during heat treatment. The aim of the present study is to derive optimized cladding conditions and thereupon obtain the stable quality of Ti/Al/STS clad materials. Ti sheets were prepared with and without pre-heat treatment and Ti/Al/STS clad materials were then fabricated by cold rolling and a post-heat treatment process. Microstructure of the Ti/Al and STS/Al interfaces was observed using a Scanning Electron Microscope(SEM) and an Energy Dispersed X-ray Analyser(EDX) in order to investigate the effects of Ti pre-heat treatment on the bond properties of Ti/Al/STS clad materials. Diffusion bonding was observed at both the Ti/Al and STS/Al interfaces. The bonding force of the clad material with non-heat treated Ti was higher than that with pre-heat treated Ti before the cladding process. The bonding force decreased rapidly beyond $400^{\circ}C$, because the formed Ti oxide inhibited the joining process between Ti and Al. Bonding forces of STS/Al were lower than those of Ti/Al, because brittle $Fe_3Al$, $Al_3Fe$ intermetallic compounds were formed at the interface of STS/Al during the cladding process. In addition, delamination of the clad material with pre-heat treated Ti was observed at the Ti/Al interface after a cupping test.

하수처리수 재이용을 위하여 Sym-bio공정과 용존 오존 부상공정을 이용한 하수처리의 효율 분석 (A Treatment Efficiency of Wastewater by using Sym-Bio Process and Dissolved Ozone flotation Process for Water Reuse)

  • 박찬규;박재한;이경희;안윤희;고광백;정현철
    • 한국물환경학회지
    • /
    • 제24권1호
    • /
    • pp.86-90
    • /
    • 2008
  • Water reuse of effluent is limited, due to bacteria and chromaticity or turbidity which may result in low perception of water quality. Consequently, this study showed a method in the reuse of treated wastewater by a diversified treatment method, with separation of centralized reformation of aeration tank into pre-treatment with minimum installation of facilities, and post-treatment, applying advanced oxidation treatment. A pilot plant experiment was performed using Sym-Bio process adopting an NADH Sensor without modification of the exiting aeration tank. The Dissolved Ozone Flotation process, which is an advanced oxidation process, to treat the remaining organics, nutrients, chromaticity, turbidity and bacteria. As a result in the Sym-Bio process, the biological treatment, even on the condition of single stage reaction tank, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS and T-N were 96.6%, 84.6%, 88.25%, 95.1% and 71.0%, respectively, while that for T-P was 25.0%, which required further treatment. In the Dissolved Ozone Flotation process, the advanced oxidation treatment, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS, T-N, T-P, chromaticity, turbidity, bacteria, coliforms were 78.9%, 34.6%, 28.7%, 48.0%, 70.4%, 82.4%, 84.0%, 74.5%, 99.8% and 99.4%, respectively.

하.폐수 고도처리 기술개발사업 추진배경과 개발방향 (The Background and Direction of R&D Project for Advanced Technology of Wastewater Treatment and Reuse)

  • 김지태;황혜영;홍병표;변홍식
    • 멤브레인
    • /
    • 제21권3호
    • /
    • pp.277-289
    • /
    • 2011
  • 1980년대 이후 국내 하 폐수 처리시설에 대한 지속적인 투자로 하수도 보급률이 90%에 이를 만큼 비약적으로 확충되었다. 21세기 들어 물 부족에 대비한 대체수자원 확보, 기후변화 등 지구환경문제에 대비한 에너지 절감 및 생산, 하천 호소의 지속적인 수질개선 요구 등 사회적 환경적 영향 요소를 감안할 때 더욱 고도화된 선진 하 폐수 처리기술이 필수적이다. 신개념 처리기술은 수질유해물질 및 독성관리기술 등 초고도 처리기술, 맞춤형 재이용기술, 에너지 절감 회수 활용 기술을 유기적으로 조합 연계하는 기술이다. 이러한 선진 처리기술은 국내 수질환경개선은 물론 개도국을 중심으로 급성장세를 보이는 국제 환경시장에서의 경쟁력 확보의 토대가 될 것이므로 글로벌 탑 수준을 지향하는 하 폐수 고도처리 기술개발 사업에서는 상기 기술 분야를 중점 개발하고자 한다. 본 사업단은 방류수 고품질화. 재이용 기술 분야, 에너지자립 분야, 통합관리 분야로 구분, 향후 1단계 5개년(2011-2015) 사업을 본격 추진할 예정이다.

폴리케톤 섬유의 산소 플라즈마 처리에 따른 천연고무와의 계면접착 특성 (Interfacial Adhesion Properties of Oxygen Plasma Treated Polyketone Fiber with Natural Rubber)

  • 원종성;최혜영;유재정;최한나;용다경;이승구
    • 접착 및 계면
    • /
    • 제13권1호
    • /
    • pp.45-50
    • /
    • 2012
  • 폴리케톤(polyketone, PK) 섬유는 고무의 강화재로 사용하기 위해서 최근 개발되고 있는 소재이다. 섬유의 고무와의 접착성을 향상시키기 위하여 플라즈마로 표면을 개질하였다. 산소 플라즈마 처리에 의한 섬유표면의 물리적 형태변화를 관찰하기 위하여 주사전자현미경과 원자현미경을 이용하여 관찰하였다. 섬유표면의 화학적 조성변화를 XPS (X-ray photoelectron spectroscopy)를 이용하여 알아보았다. 최종적으로 이러한 변화가 PK 섬유와 고무와의 계면접착력에 어떠한 영향을 미치는지를 microdroplet debonding 시험을 통해 분석하였다. 플라즈마 처리에 의하여 섬유표면에 산소함유기들이 증가하는 결과를 보였으며, 처리시간과 처리전력이 증가함에 따라 에칭에 의한 표면조도(RMS roughness)가 증가하였다. 그러나 장시간의 플라즈마 처리조건에서는 표면에 degradation이 발생하여 오히려 표면조도가 감소하는 결과를 보였다. PK 섬유와 고무와의 계면전단강도는 처리시간 60 s의 80 W, 처리전력 60 W의 180 s에서 처리한 경우에 최대 계면전단강도를 나타내었다. 그러나 그 이상으로 증가하면 degradation이 발생하면서 계면전단강도가 감소하였다.

Co-sputtering에 의해 증착된 TiNi 박막의 미세조직 및 기계적성질에 미치는 어닐링 열처리 효과 (Effects of Annealing Treatments on Microstructure and Mechanical Property of co-sputtered TiNi Thin Film)

  • 박수대;백창현;홍주화
    • 열처리공학회지
    • /
    • 제21권1호
    • /
    • pp.26-32
    • /
    • 2008
  • Effects of annealing treatment on microstructure and mechanical property of co-sputtered TiNi thin films were studied. As-deposited films showed amorphous state. However, above annealing temperature of $500^{\circ}C$ martensite phase (B19'), precipitate phase ($Ti_2Ni$) and a small amount of parent phase ($B_2$) were present, and phase transformation behaviors were three multi-step phase transformations $B19^{\prime}{\rightarrow}B_2$ and $B_2{\rightarrow}R-phase$ and $R-phase{\rightarrow}B19^{\prime}$. Increase of martensite transformation temperature, increase of microhardness and Young's modulus of TiNi films annealed above $500^{\circ}C$ were discussed in terms of precipitate phase.

Fouling and cleaning protocols for forward osmosis membrane used for radioactive wastewater treatment

  • Liu, Xiaojing;Wu, Jinling;Hou, Li-an;Wang, Jianlong
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.581-588
    • /
    • 2020
  • The membrane fouling is an important problem for FO applied to the radioactive wastewater treatment. The FO fouling characteristics for simulated radioactive wastewater treatment was investigated. On-line cleaning by deionized (DI) water and external cleaning by ultrasound and HCl were applied for the fouled membrane. The effectiveness and foulant removing amount by each-step cleaning were evaluated. The membrane fouling was divided into three stages. Co(II), Sr(II), Cs(I), Na(I) were all found deposited on both active and support layers of the membrane surface, resulting in membrane surface became rougher and more hydrophobic, which increased membrane resistance. On-line cleaning by DI water recovered the water flux to 69%. HCl removed more foulants than ultrasound.

고도처리 하수처리장 운전조건의 통계분석 (Statistical Analysis of Operating Parameters on Advanced Wastewater Treatment Plant)

  • 이찬형;문경숙
    • 한국환경과학회지
    • /
    • 제14권2호
    • /
    • pp.251-258
    • /
    • 2005
  • Statistical analysis between operating parameters and effluent quality on advanced wastewater treatment plant was performed. Through factor analysis four factors derived varimax rotation were selected each plant. Four components explained $80\%,\;82\%$ of the total variance of the process, respectively. The components on MLE plant were identified in the following order: 1) HRT increase and BOD load decrease by influent decrease, 2) Biomass, 3) SVI increase by internal return increase, 4) Microbial diversity by SRT increase. On $A_2O$ plant, we defined them as follows: factor 1, high MLSS by return rate increase, HRT increase by influent decrease; factor 2, biomass; factor 3, BOD of influent; factor 4 was relate to DO.

Nedaplatin Salvage Chemotherapy for Cervical Cancer

  • Li, Wu-Ju;Jiang, Jia-ying;Wang, Xian-Lian
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3159-3162
    • /
    • 2015
  • Purpose: This systematic analysis was conducted to evaluate the efficacy and safety of nedaplatin based salvage chemotherapy for treatment of patients with advanced cervical cancer. Methods: Clinical studies evaluating the efficacy and safety of nedaplatin based regimens on response and safety for patients with cervical cancer were identified using a predefined search strategy. Pooled response rates (RRs) were calculated. Results: For nedaplatin based regimens, 5 clinical studies including 264 patients with advanced cervical cancer were considered eligible for inclusion. The analysis showed that, in all patients, pooled RR was 74.6% (197/264). Major adverse effects were leukopenia, thrombocytopenia and nausea/vomiting. No treatment related death occurred with nedaplatin based treatment. Conclusion: This systematic analysis suggests that nedaplatin based regimens are associated with good activity with acceptable tolerability in treating patients with advanced cervical cancer.