• Title/Summary/Keyword: Advanced medical device

Search Result 134, Processing Time 0.023 seconds

Lubrication Modeling of Reciprocating Piston in Piston Pump with High Lateral Load (강한 측력이 작용하는 피스톤 펌프의 왕복동 피스톤 기구 부에서의 윤활모형에 관한 연구)

  • Shin, JungHun;Jung, DongSoo;Kim, KyungWoong
    • Tribology and Lubricants
    • /
    • v.30 no.2
    • /
    • pp.116-123
    • /
    • 2014
  • The objective of this study is to model and simulate the nonlinear lubrication performance of the sliding part between the piston and cylinder wall in a hydrostatic swash-plate-type axial piston pump. A numerical algorithm is developed that facilitates simultaneous calculation of the rotating body motion and fluid film pressure to observe the fluid film geometry and power loss. It is assumed that solid asperity contact, so-called mixed lubrication in this study, invariably occurs in the swash-plate-type axial piston pump, which produces a higher lateral moment on the pistons than other types of hydrostatic machines. Two comparative mixed lubrication models, rigid and elastic, are used to determine the reaction force and sliding friction. The rigid model does not allow any elastic deformation in the partial lubrication area. The patch shapes, reactive forces, and virtual local elastic deformation in the partial lubrication area are obtained in the elastic contact model using a simple Hertz contact theory. The calculation results show that a higher reaction force and friction loss are obtained in the rigid model, indicating that solid deformation is a significant factor on the lubrication characteristics of the reciprocating piston part.

A Study on the Development of Telephone for Improvement of the Hearing Impaired's Listening (난청인의 통화 청취도 향상을 위한 전화기 개발연구)

  • Lee, S.M.;Woo, B.C.;Kim, D.W.;Song, C.G.;Lee, Y.M.;Kim, W.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.111-113
    • /
    • 1996
  • The impaired person and the elderly who has hearing loss have been continuously increased and these people's desire for participating society as a producer has been increased also. So they strongly request the aid device which can compensate their handicap. The healing aid telephone is one of the basic aid devices that helps the hearing impaired to communicate with other people and to acquire useful information. We design the new model of the hearing aid telephone and test it's efficiency in three fields - electrical, speech perception, user test. From the result of the test we certify that the new model is better for the hearing impaired to understand the meaning of telephone speech than the old general models. We expect that the advanced healing aid telephone can be developed by the research about speech perception characteristics of the hearing impaired in engineering and clinical side.

  • PDF

Analysis of International Research Trends on Metaverse

  • Mina, Shim
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.453-459
    • /
    • 2022
  • This study attempted to explore the realization and research direction of a successful metaverse environment in the future by analyzing international research trends of the metaverse using topic modeling. A total of 208 papers among WoS and ScienceDirect papers using metaverse as keywords were selected, and quantitative frequency analysis and topic modeling were performed. As a result, it was confirmed that research has rapidly increased after 2022. The main keywords of the research topics were 'second', 'life', 'learning', 'reality', 'metaverse', 'virtual', 'blockchain', 'nft', 'medical', 'avatar', etc. The topic keywords 'Second life & Education' and 'Virtual Reality & Medical' accounted for a large proportion of 57%, followed by 'Blockchain & Cryptocurrency', 'Avatar & Interaction', and 'Sensing and Device'. As a result of semantic analysis, current metaverse research is focused on application and utilization, and research on underlying technologies and devices is also active. Therefore, it is necessary to identify the commonalities and differences between domestic and foreign studies, and to study the application method considering the domestic environment. In addition, new jurisprudence research is more necessary along with predicting new problems. It is expected that the results of study will provide the right research direction for domestic researchers in the era of digital transformation and contribute to the realization of a digital society.

Introduction to IEC Standardization for Superconducting Sensors and Detectors

  • Ohkubo, M.
    • Progress in Superconductivity
    • /
    • v.14 no.2
    • /
    • pp.106-109
    • /
    • 2012
  • Superconducting sensors and detectors have been applied to many fields or beginning to enter the maturing stage. The applications spread over a wide range of fields such as radio telescope, medical examination, quantum information, contamination inspection, materials analysis, etc. For users of the superconducting devices as well as developers, we have to avoid confusion of naming, graphical circuit symbols, and measurement methods for device performance. We are trying to formulate international standards under the International Electrotechnical Commission - Technical Committee 90 (IEC-TC90), which is responsible for superconductivity. The sensors and detectors to be considered are divided into two groups: coherent sensors (SQUID, SIS mixers, etc.) and direct detectors (TES, STJ, MKID, SSPD, etc.).

Study on Timing Failures in Cyber-Physical Systems

  • Kong, Joon-Ik
    • International journal of advanced smart convergence
    • /
    • v.11 no.3
    • /
    • pp.56-63
    • /
    • 2022
  • Cyber-physical systems (CPSs) can solve real problems by utilizing closely connected resources in the cyber world. Most problems arise because the physical world is uncertain and unpredictable. To address this uncertainty, information pouring from numerous devices must be collected in real-time, and each interconnected device must share the information. At this time, CPS must meet timing-related techniques and strict timing constraints that can deliver accurate information within predefined deadlines in order to interact closely beyond simply connecting the cyber and physical worlds. Timing errors in safety-critical systems, such as automobiles, aviation, and medical systems, can lead to catastrophic disasters. In this paper, we classify timing problems into two types: real-time delay and synchronization problems. The results of this study can be used in the entire process of CPS system design, implementation, operation, verification, and maintenance. As a result, it can contribute to securing the safety and reliability of CPS.

Nanoparticle Inducing Device for Effective Drug Delivery System (효과적인 약물전달 시스템을 위한 나노입자 유도 장치)

  • Lee, Chongmyeong;Han, Hyeonho;Jang, Byonghan;Oh, Eunseol;Key, Jaehong
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.102-110
    • /
    • 2017
  • Cancer is one of the most challenging human diseases. Current clinical methods have limitations for early-stage cancer diagnosis and effective therapy. Moreover, current surgical methods to remove tumors are not precise enough and chemotherapy destroys normal tissues as well as malignant tumors, resulting in severe side effects such as hair loss, vomiting, diarrhea, and blood disorders. Recently, nanotechnology using nano-sized particles suggests advanced solutions to overcome the limitations. Various nanoparticles have been reported for more accurate diagnosis and minimized side effects. However, current nanoparticles still show limited targeting accuracy for cancer generally below 5% injection dosage. Therefore, herein we report a new nanoparticle inducing device(NID) to guide the nanoparticles externally by using both variable magnetic fields and blood flows. NID can be a promising approach to improve targeting accuracy for drug delivery using iron oxide nanoparticles.

Polish of interface areas between zirconia, silicate-ceramic, and composite with diamond-containing systems

  • Pott, Philipp-Cornelius;Hoffmann, Johannes Philipp;Stiesch, Meike;Eisenburger, Michael
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.315-320
    • /
    • 2018
  • PURPOSE. Fractures, occlusal adjustments, or marginal corrections after removing excess composite cements result in rough surfaces of all-ceramic FPDs. These have to be polished to prevent damage of the surrounding tissues. The aim of this study was to evaluate the roughness of zirconia, silicate-ceramic, and composite after polish with different systems for intraoral use. MATERIALS AND METHODS. Each set of 50 plates was made of zirconia, silicate-ceramic, and composite. All plates were ground automatically and were divided into 15 groups according to the treatment. Groups Zgrit, Sgrit, and Cgrit received no further treatment. Groups Zlab and Slab received glaze-baking, and group Clab was polished with a polishing device. In the experimental groups Zv, Sv, Cv, Zk, Sk, Ck, Zb, Sb, and Cb, the specimens were polished with ceramic-polishing systems "v", "k", and "b" for intraoral use. Roughness was measured using profilometry. Statistical analysis was performed with ANOVA and $Scheff{\acute{e}}$-procedure with the level of significance set at P=.05. RESULTS. All systems reduced the roughness of zirconia, but the differences from the controls Zgrit and Zlab were not statistically significant (P>.907). Roughness of silicate ceramic was reduced only in group Sv, but it did not differ significantly from both controls (P>.580). Groups Cv, Ck, and Cb had a significantly rougher surface than that of group Clab (P<.003). CONCLUSION. Ceramic materials can be polished with the tested systems. Polishing of interface areas between ceramic and composite material should be performed with polishing systems for zirconia first, followed by systems for veneering materials and for composite materials.

A Comparative Study on the Regulations on Implantable Bioabsorbable Combination Products -Focusing on the U.S., Europe and Korea- (이식형 흡수성 융복합 의료제품 규제 비교 연구 -미국, 유럽, 한국을 중심으로-)

  • Hyeon Jeong Lee;Mi Hye Kim;Ju Eun Seol;Su Dong Kim;Joo Hee Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.414-427
    • /
    • 2023
  • Implantable bioabsorbable combination products undergo inherent degradation and systemic absorption within the physiological environment, thereby streamlining the therapeutic regimen and obviating the imperative for invasive extraction procedures. This inherent property not only enhances patient convenience and therapeutic efficacy but also underpins a paradigm of support characterized by heightened safety parameters. Within the regulatory landscapes of Korea, the United States, and Europe, implantable bioabsorbable combination products are meticulously classified into distinct categories, either as pharmaceutical implants or as implantable medical devices, depending on their primary mode of action. This scholarly investigation systematically examines the regulatory frameworks governing implantable bioabsorbable combination products in South Korea, the United States, and Europe. Notable discrepancies across national jurisdictions emerge concerning regulatory specifics, including terminology, product classification, and product name associated with these products. The conspicuous absence of standardized approval regulations presents a formidable barrier to the commercialization of these advanced medical devices. This academic discourse passionately emphasizes the critical need for formulating and implementing a sophisticated regulatory framework capable of streamlining the product approval process, thereby paving the way for a seamless path to commercializing implantable bioabsorbable combination products.

A study on Supply Extension Device of AED (AED의 보급 확대 방안에 관한 연구)

  • Koh, Jae-Moon;Kim, Young-Ho;Han, Sang-Hak
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.2
    • /
    • pp.147-168
    • /
    • 2005
  • It examined the doubt point which AED motive relates until now, the AED should have bought a life how, present address of our country site pre-hospital care, comparison it tried to observe the advanced nation instance back. Gist of this research the AED important cold region once compared to informed to how many cardiac arrest patient, against him the what kind of preparation wanted informing the necessary cold region. It soaks simultaneously but the AED motive is widely supplied distant in future and it is generality and it is feeble but it wanted doing one morning. The habit difference of an American who does of course meat diet mainly and a Korean is many and it compares in the United States and the cardiac arrest patient comparison occurs holds a point few. To become Western anger but and be caused by with thin dietary life, stanching bleeding cung, with the fact that the heart attack is increasing rapidly with the hyperextension. It is a talk which anyone it knows all. The major league most Choi huy Sub in condition will catch the ball which floats and the multi co-player and to collide when falling down, the medical device which is committed with emergency aid is AED motive. From the United States subway station and the shopping which are a public place on the baseball field outside the jar which it will drive, the museum and the school, easily there is it will be able to discover the AED from the court of justice back. The Pittsburg university the students per the individual $30 the core phyey were receiving the smallness lifestyle alcoholic beverage and a AED motive actual training with mercy of degree. From the United States distant in future the AED motive is sold even from the retail store and. From our country like this plan government offices temporary disposal education from from 119 fire fighters emergency structure company in fire fighting government employee and nursing must magnify a former enterprise rainy spell in summer multi temporary disposal education with the head which it will burn with the head. This plan in early rising will be able to become fixed in Korea it forecasts with the fact that. The research which it sees it leads and like the United States to some day become fixed even from our country to believe and suspicion it is not and in the people in approach ease one AED supply plan fire fighting government employees stand in the first and feed with the fact that must be positive at this enterprise they become.

  • PDF

Development of High Entropy Alloy Film using Magnetron Sputtering

  • Kim, Young Seok;Lim, Ki Seong;Kim, Ki Buem
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.129-129
    • /
    • 2018
  • Hard coating application is effective way of cutting tool for hard-to-machine materials such as Inconel, Ti and composite materials focused on high-tech industries which are widely employed in aerospace, automobile and the medical device industry also Information Technology. In cutting tool for hard-to-machine materials, high hardness is one of necessary condition along with high temperature stability and wear resistance. In recent years, high-entropy alloys (HEAs) which consist of five or more principal elements having an equi-atomic percentage were reported by Yeh. The main features of novel HEAs reveal thermodynamically stable, high strength, corrosion resistance and wear resistance by four characteristic features called high entropy, sluggish diffusion, several-lattice distortion and cocktail effect. It can be possible to significantly extend the field of application such as cutting tool for difficult-to-machine materials in extreme conditions. Base on this understanding, surface coatings using HEAs more recently have been developed with considerable interest due to their useful properties such as high hardness and phase transformation stability of high temperature. In present study, the nanocomposite coating layers with high hardness on WC substrate are investigated using high entropy alloy target made a powder metallurgy. Among the many surface coating methods, reactive magnetron sputtering is considered to be a proper process because of homogeneity of microstructure, improvement of productivity and simplicity of independent control for several critical deposition parameters. The N2 is applied to reactive gas to make nitride system with transition metals which is much harder than only alloy systems. The acceleration voltage from 100W to 300W is controlled by direct current power with various deposition times. The coating layers are systemically investigated by structural identification (XRD), evaluation of microstructure (FE-SEM, TEM) and mechanical properties (Nano-indenter).

  • PDF