• 제목/요약/키워드: Advanced Treatment Process

검색결과 1,033건 처리시간 0.033초

주조용 TiAl 합금의 조직 미세화를 위한 반복열처리 공정 조건에 관한 연구 (The Effects of Cyclic Heat Treatment Process for Fine Microstructure of TiAl Cast Alloy)

  • 공만식;양현석
    • 열처리공학회지
    • /
    • 제32권5호
    • /
    • pp.195-200
    • /
    • 2019
  • For expanding the applications and workability of TiAl alloy, elongation is very important property. Fine microstructure is needed for elongation and physical properties of TiAl alloys. In this study, The effects of cyclic heat treatment process for fine microstructure of Ti-46Al-Nb-W-Cr-Si-C alloy, which was made by VAR (vacuum arc remelting) and VIM(vacuum induction melting) centrifugal casting process, was investigated. Cycle heat treatment process was very effective for recrystallization of this TiAl system, which has microstructure size of $50{\sim}100{\mu}m$ through pre-heat treatment, cyclic heat treatment in ${\alpha}+{\gamma}$ phase region and solution heat treatment respectively. Refined grain size was finally confirmed by photos of optical microscope and scanning electron microscope.

하수처리장의 고도처리 upgrading 설계와 공정 최적화를 위한 다변량 통계분석 (Design of a Wastewater Treatment Plant Upgrading to Advanced Nutrient Removal Treatment Using Modeling Methodology and Multivariate Statistical Analysis for Process Optimization)

  • 김민정;김민한;김용수;유창규
    • Korean Chemical Engineering Research
    • /
    • 제48권5호
    • /
    • pp.589-597
    • /
    • 2010
  • 하수처리 시스템에서의 생물학적 영양염류 기준이 강화됨에 따라, 표준활성슬러지공법으로 운전 중인 하수처리장의 고도처리 공법으로의 개보수 필요성이 증가하고 있다. 그러나 실제 하수처리 시스템에서의 다양한 유입조건 및 운전조건의 복잡한 반응 구성으로 인해 실험을 통하여 개보수된 고도처리공법의 최적조건을 찾는 것은 쉽지 않은 일이며, 이는 많은 시간과 비용을 소모하여 비효율적이다. 따라서 본 연구에서는 활성슬러지공정모델(ASMs)을 기반으로 한 하수처리장의 모델링 및 시뮬레이션 기법을 통하여 하수처리장의 고도처리공법으로의 upgrading 설계를 수행하며, 이를 통계적이며 체계적으로 접근하기 위해 반응표면분석법(Response surface method)을 통한 고도처리공법의 설계 최적화를 수행하였다. 또한 실규모 하수처리장에서의 운전 최적화를 위해서는 하수처리의 동력학적 매개변수에 대한 정확한 분석이 수행되어야 한다. 본 연구에서는 다변량 통계분석 기법인 부분최소승자법(PLS)을 통하여 하수처리 시스템의 동력학적 매개변수 간의 상관관계를 파악하며, 고도처리공법 하수처리장의 운전 결과에 가장 큰 영향을 미치는 매개변수를 도출하였다. 본 연구를 통해 하수처리장의 고도처리공법 upgrading 설계 및 운전 최적화를 위한 방법론을 제시하였으며, 이를 통하여 설계시간 및 경비 절감 등 고도처리공법으로의 고효율적인 개보수가 가능할 것으로 예상된다.

주석 함유 폐자원의 공정부산물 전처리 기술 (Development of Pre-treatment for Tin Recovery from Waste Resources)

  • 진연호;장대환;정항철;이기웅
    • 한국분말재료학회지
    • /
    • 제21권2호
    • /
    • pp.142-146
    • /
    • 2014
  • Fundamental experiences have been studied for development of pre-treatment process of Sn by-products such as solders. Dry and wet separation/recovery processes were considered by the differences of physical properties. The by-products, which are analyzed by solder metal and oxides. The metal and oxide were simply separated by dry ball-milling process for 12 hours, after that recovery metal powder might be reusable as lead or lead-free solders. In terms of wet separation process, samples were dissolved in $HNO_3+H_2O_2$ and the precipitation were analyzed by $SnO_2$. Overall efficiency of recovery might be increasing via developing simple pre-treatment process.

활성슬러지공정과 고도처리공정에 따른 하수처리수의 처리효율과 유기물 특성 (Treatment Efficiency and Organic Matter Characterization of Wastewater through Activated Sludge Process and Advanced Wastewater Treatment Process)

  • 홍지혜;손진식
    • 상하수도학회지
    • /
    • 제18권6호
    • /
    • pp.807-813
    • /
    • 2004
  • Wastewater was treated by two different treatment processes; activated sludge process and advanced wastewater treatment process (KNR process) using lab-scale experiment. Two treated wastewater showed good treatment efficiency of organic matter removal, up to 90% removal. Nitrogen and phosphorus were not effectively removed though activated sludge process, while KNR process showed good removal efficiency of nitrogen and phosphorus; 56% nitrogen removal and 95% phosphorus removal. KNR process showed better removal efficiency of organic matter, nitrogen, and phosphorus compared to activated sludge process. Organic matter characterization was tracked though measurement of UV scan, SUVA, and XAD fractionation. Treated wastewater showed higher SUVA value than wastewater influent, indicting less aromatic characteristic of organic matter. XAD fractionation showed hydrophilic fraction decreased though wastewater treatment, suggesting microbes preferentially digest hydrophilic and aliphatic molecules rather than hydrophobic and aromatic molecules of organic matter.

최적 고도정수처리공정 선정을 위한 경제성 평가 (Cost Evaluation for the Decision of Advanced Treatment Processes)

  • 이경혁;신흥섭;안효원;채선하;임재림
    • 상하수도학회지
    • /
    • 제22권5호
    • /
    • pp.511-516
    • /
    • 2008
  • Since 1989, Advanced drinking water treatment processes began to build in Korea, especially the water treatment plants around the Nak-dong river stream due to sequential pollutant accidents. Moreover, Advanced drinking water treatment processes, ozone and GAC, are again to be built in water treatment plants around Han-river stream to control taste and odor, micro pollutants. However, there are still a lot of discussion to decide the processes to apply for advanced treatment. Thus there are still need to understand clearly on the cost evaluation of each advanced treatment processes. The cost evaluation was accomplished based on the data of six water treatment plants which are currently being either operating or constructing. Exceptionally, PAC(Powdered Activated Carbon) process was evaluated with cost estimation from construction company. The capital cost per unit volume of ozone process was significantly decreased as the treatment capacity increased. The capital cost was in the order of GAC, ozone and GAC. The operation cost decreased in the order of PAC, GAC and ozone. The total cost considering present value shows that ozone process covers 84% of ozone and GAC process for $30,000m^3/d$ capacity while it covers less than 35% for over 140 thousands $m^3/d$ capacity. Comparing GAC only, and ozone/GAC process, ozone/GAC process is more cost effective for high capacity water treatment plant.

소화탈리액 대상 오존 전처리와 Ultra Violet-Advanced Oxidation Process 연계 처리를 통한 유기물질 지표 개선 (Improvement of Organic Substances Indicators by Linked Ultra Violet-Advanced Oxidation Process After Ozonation for Anaerobic Digested Wastewater)

  • 이재엽;제스민아터;김일호
    • 상하수도학회지
    • /
    • 제37권5호
    • /
    • pp.253-259
    • /
    • 2023
  • Bioreactors are devices used by sewage treatment plants to process sewage and which produce active sludge, and sediments separated by solid-liquid are treated in anaerobic digestion tanks. In anaerobic digestion tanks, the volume of active sludge deposits is reduced and biogas is produced. After dehydrating the digestive sludge generated after anaerobic digestion, anaerobic digested wastewater, which features a high concentration of organic matters, is generated. In this study, the decomposition of organic carbon and nitrogen was studied by advanced oxidation process. Ozone-microbubble flotation process was used for oxidation pretreatment. During ozonation, the TOC decreased by 11.6%. After ozone treatment, the TOC decreased and the removal rate reached 80.4% as a result of the Ultra Violet-Advanced Oxidation Process (UV-AOP). The results with regard to organic substances before and after treatment differed depending on the organic carbon index, such as CODMn, CODCr, and TOC. Those indexes did not change significantly in ozone treatment, but decreased significantly after the UV-AOP process as the linkage treatment, and were removed by up to 39.1%, 15.2%, and 80.4%, respectively. It was confirmed that biodegradability was improved according to the ratio of CODMn to TOC. As for the nitrogen component, the ammonia nitrogen component showed a level of 3.2×102 mg/L or more, and the content was maintained at 80% even after treatment. Since most of the contaminants are removed from the treated water and its transparency is high, this water can be utilized as a resource that contains high concentrations of nitrogen.

하수처리시설에서 인 고도처리를 위한 자동제어시스템 개발에 관한 연구 (Development of the Automatic Control System for the Advanced Phosphorus Treatment in Sewage Treatment Plant)

  • 김선국;이호식;전태성
    • 한국물환경학회지
    • /
    • 제28권2호
    • /
    • pp.300-304
    • /
    • 2012
  • It has a limitation to satisfy the phosphorus effluent criteria of 0.2 mg/L which will be reinforced from 2012 with the Biological Nutrient Removal (BNR) process. The chemical coagulation process has been operated in parallel with the biological treatment process for advanced treatment of phosphorous in the developed countries including Europe. However, the coagulation process has some disadvantages such as the desired goal may not be achieved without injecting the optimum dosage of the coagulant. This study developed the automatic control system to inject the optimum dosage of phosphorous coagulant into the coagulation process. The adopted coagulant was 10% Poly Aluminum Chloride (PAC) in this study. The automatic control system developed in this study was adopted for the treatment of the phosphorus from the effluent in SBR process. The automatic control system was composed of the data receiving part, the optimum coagulant dosage control part and the data transmit part. The result of the phosphorous advanced treatment of the SBR effluent using the automatic control system showed the removing efficiency over 95% consistently with the phosphorous concentration under 0.02 ~ 0.15 mg/L. The reproducibility analysis for checking the safety of automatic control system showed more than 95% correlation.

Progresses in membrane and advanced oxidation processes for water treatment

  • Khulbe, K.C.;Feng, C.Y.;Matsuura, T.;Ismail, A.F.
    • Membrane and Water Treatment
    • /
    • 제3권3호
    • /
    • pp.181-200
    • /
    • 2012
  • At present water crisis is not an issue of scarcity, but of access. There is a growing recognition of the need for increased access to clean water (drinkable, agricultural, industrial use). An encouraging number of innovative technologies, systems, components, processes are emerging for water-treatment, including new filtration and disinfectant technologies, and removal of organics from water. In the past decade many methods have been developed. The most important membrane-based water technologies include reverse osmosis (RO), ultrafiltration (UF), microfiltration (MF), and nanofiltration. Beside membrane based water-treatment processes, other techniques such as advanced oxidation process (AOP) have also been developed. Some unconventional water treatment technology such as magnetic treatment is also being developed.

난분해성 산업폐수 처리를 위한 고도산화기술 (Advanced oxidation technologies for the treatment of nonbiodegradable industrial wastewater)

  • 김민식;이기명;이창하
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.445-462
    • /
    • 2020
  • Industrial wastewater often contains a number of recalcitrant organic contaminants. These contaminants are hardly degradable by biological wastewater treatment processes, which requires a more powerful treatment method based on chemical oxidation. Advanced oxidation technology (AOT) has been extensively studied for the treatment of nonbiodegradable organics in water and wastewater. Among different AOTs developed up to date, ozonation and the Fenton process are the representative technologies that widely used in the field. Based on the traditional ozonation and the Fenton process, several modified processes have been also developed to accelerate the production of reactive radicals. This article reviews the chemistry of ozonation and the Fenton process as well as the cases of application of these two AOTs to industrial wastewater treatment. In addition, research needs to improve the cost efficiency of ozonation and the Fenton process were discussed.

산업폐수 중의 질소 성분의 제거를 위한 고도처리 공정의 응용 (Application of Advanced Treatment Process for Nitrogen Compounds Removal of Industrial Waste-water)

  • 방성훈;임은태;정귀택;박재희;박석환;김성준;박돈희
    • KSBB Journal
    • /
    • 제23권6호
    • /
    • pp.541-545
    • /
    • 2008
  • This paper was studied to research regarding the removal of contained nitrogen in industrial wastewater which uses the A2O4 advanced water treatment process. The field researches of two companies' wastewater occurred in each wastewater treatment site to apply the A2O4 process system, it was observed them for 20 days. As a result of the A2O4 system advanced wastewater process which applied an altitude control process obtained $10{\sim}76\;mg/L$, and 20 mg/L total nitrogen compound concentration in the two wastewater plants. In conclusion, it applied the A2O4 system in the two companies' wastewater system.