• 제목/요약/키워드: Advanced Sewage Treatment

검색결과 124건 처리시간 0.028초

마을하수도 운영실태 및 개선방안 (A study on the management status of public small-scale sewage treatment facilities and the improvement)

  • 신대윤;배철호
    • 환경위생공학
    • /
    • 제23권4호
    • /
    • pp.55-64
    • /
    • 2008
  • In this study, the management and improvement of public small-scale sewage treatment facilities was investigated. In order to improve the effective management of the operation of small-scale sewage treatment facilities, treatment methods and the problems associated with sewage treatment were carefully addressed based on the data and literature. The investigation results showed that sewer pipes in rural areas should be repaired to prevent sewage from leaking and small-scale operations should be required to have effective management for pollutant loads less than 50%. Also, new methods should be developed for low concentrations of sewage. A law associated with FRP treatment facilities should be established and local governments need to supervise these operations to avoid insufficient and faulty construction. It is recommended that new facilities are built with advanced treatment techniques when the old facility can not comply with nitrogen and phosphorous discharge limits. Moreover, the study shows that nutrient and coliform treatment efficiency improves when abandoned facilities are renovated with the installation of nitrification/denitrification and disinfection processes or another advanced process.

고도하수처리공법을 적용한 마을 하수도의 수질개선 평가 (Water Quality Improvement Evaluation of Community Sewerage by using Advanced Sewage Treatment)

  • 최한규;고종섭;박수진
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.57-64
    • /
    • 2012
  • In order to examine the tailorability of advanced sewage treatment of a separated sewer pipe, we observed the quality of leaked water in a reactor. A2C affiliation and MBR affiliation decreased by over 78% in cases of BOD, COD, and SS. SBR affiliation decreased by 79.1% in a case of T-N. Overall, the efficiency of T-N on the above affiliations was low. SS had the high efficiency in MBR affiliation. In the end, examination of water quality improvement showed that the quality was improved from 20% to 90%; hence, it is expected that this treatment can protect the water resources of the Hongcheon River and makes it easier to use the water of the river.

  • PDF

분류식 하수관거에서의 고도하수처리공법 적용성 해석 (Application analysis of advanced sewage treatment on the separated sewer pipe)

  • 박수진;고종섭;백경원;최한규
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.772-777
    • /
    • 2012
  • In order to examine the tailorability of advanced sewage treatment of a separated sewer pipe, we observed the quality of leaked water in a reactor. A2C affiliation and MBR affiliation decreased by over 78% in cases of BOD, COD, and SS. SBR affiliation decreased by 79.1% in a case of T-N. Overall, the efficiency of T-N on the above affiliations was low. SS had the high efficiency in MBR affiliation. In the end, examination of water quality improvement showed that the quality was improved from 20% to 90%; hence, it is expected that this treatment can protect the water resources of the Hongcheon River and makes it easier to use the water of the river.

  • PDF

충청남도 마을하수처리시설의 최적 설치방안 (Alternatives for Optimum Installation of Rural Sewage Treatment Facilities in Chungchongnam-do Province)

  • 이상진;정종관;임봉수;허재영
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.462-472
    • /
    • 2005
  • This study was carried out to suggest the plans for installation of rural sewage treatment facilities through the analysis of these facilities installed in Chungchongnam-do Province. About 5% of all installation was carried out by the department of wastewater and related environment problems and the other case was carried out by the department of construction or residence. In wastewater caused by 250 and 300 persons, facilities capacity do not exceed about $50m^3/d$, caused by 2,500 and 3,000 persons, $500m^3/d$. Advanced sewage treatment process were first needed in the discharge area where affected the water environment greatly. However, in carrying out the water quality pollutant of the total amount management system in the other areas, they should be driven only over the scale of pollutant quota object facilities standard. Rural sewage must be included in the special accounts according to the regulations of local government, and sewage treatment cost should be collected to manage. Installation type uses integrating joint treatment method in case the distance among villages is short or one treatment facility independently.

폐플라스틱용기 미디어를 활용한 오수고도처리 (Advanced Treatment of Sewage Using Waste Plastic Vessel Media)

  • 김재용;엄명헌;안대현;심명진
    • 공업화학
    • /
    • 제17권1호
    • /
    • pp.58-61
    • /
    • 2006
  • 본 연구는 폐플라스틱용기 미디어 산화공법을 이용하여 유체 및 산소전달 효율 향상을 위한 개조 방법과 미생물 부착특성을 향상시키는 방법을 통하여 오수고도처리 함을 목적으로 하고 있다. 또한 실험실 규모의 실험에서 최적의 담체 층진율과 충진 방법을 도출함으로써, 실 규모 설비를 위한 최적 설계 인자와 운전인자를 확보하고, 오수의 고도처리를 위한 다양한 운전조건을 제공하여 폐플라스틱 용기를 미생물 담체로 사용할 경우 생물학적 반응에 의해서 분해 될 때 소비되는 산소량과 오수중에 현탁되어 있는 유, 무기성 부유물과 질소 제거가 이루어지는 메카니즘을 규명하고 오수 처리 효율 향상을 위한 운전인자 도출을 목표로 한다.

하수처리장 연계처리를 위한 가축분뇨 최적 처리공정 선정에 관한 연구 (Determination of Optimal Livestock Wastewater Treatment Process for Linked Treatment in Sewage Treatment Plant)

  • 김충곤;신현곤
    • 유기물자원화
    • /
    • 제20권3호
    • /
    • pp.52-59
    • /
    • 2012
  • 처리공정별 연계처리수질을 검토한 결과 생물학적처리만 거친 생물반응조 처리수의 경우 연계부하율이 $COD_{Mn}$의 경우 1.67%(설계수질 기준), 2.59%(운영수질 기준), T-P의 경우 3.69%(설계수질 기준), 7.67%(운영수질 기준)로 다소 높게 나타났으나 하수처리장 운영에 미치는 영향은 거의 없을 것으로 판단된다. 또한, 고도처리공정인 산화부상분리 처리수 및 생물여과 처리수의 경우 연계부하율은 1% 내외로 고도처리설비 설치 시 과대 설비설치의 우려가 있다. 따라서 S하수처리장의 경제성 및 안정적인 운영을 고려할 경우 생물학적처리인 생물반응조를 거친 처리수를 연계하는 것이 바람직할 것으로 판단된다.

The Characteristics with HRT Variation on InSub Pilot Plant for Advanced Sewage Treatment

  • Kang, Jin-Young;Huh, Mock
    • Environmental Engineering Research
    • /
    • 제14권3호
    • /
    • pp.174-179
    • /
    • 2009
  • The InSub system(applied for a patent) was developed, as it combined the indirectly aerated submerged biofiltration(InSub) reactor and Anaerobic/ Anoxic reactor. This system which can eliminate organism and nutrient materials at the same time, which is safe and economical to be maintained and managed is more simple process than the complicated existing biological advanced sewage treatment system. The most suitable HRT of this study showed 9 hours. As looking into the effluent concentration and removal efficiency of each item at 9 hours of HRT, each effluent concentration for $SS,\;BOD5,\;COD_{Mn},\;and\;COD_{Cr}$ was 1.46 mg/L, 7,09 mg/L, 9.84 mg/L and 16.42 mg/L. And their removal efficiency was 96.98%. 90.59%, 77.18% and 83.92%, respectively. Each effluent concentration of T-N and T-P was 10.42 mg/L and 1.04 mg/L. Their removal efficiency was 73.38% and 61.62%, respectively. This pilot plant experiment(the state was without the internal recycling.) followed a variety of HRT. The results confirmed that it was to be advanced sewage treatment system with high efficiency when it combined with the internal recycling.

공공하수처리시설의 총인기준 강화에 따른 비용효과분석 (Analysis of the cost effectiveness according to T-P standard enforcement of public sewage treatment facilities)

  • 정원구;임재명
    • 산업기술연구
    • /
    • 제31권A호
    • /
    • pp.135-145
    • /
    • 2011
  • This study was conducted to analyze the cost effectiveness in line with total phosphorus standard enforcement of public sewage treatment facilities. The additional cost for the total phosphorus removal process was calculated to analyze the cost effectiveness of the advanced water purification process. The analysis results showed that the T-P removal by coagulation sedimentation was more efficient than the advanced water purification facilities in terms of facilities investment cost, and if the coagulation filteration was used for T-P removal, the activated carbon process among the advanced water purification techniques was more efficient in terms of facilities investment cost. In this study, the effects of the T-P removal process that will be additionally introduced according to the tightening of the effluent T-P standard were analyzed within a limit. The actual benefits of improved T-P concentration in the water source will provide diverse values, including the leisure water, environment improvement water, eco-system in the water source and industrial water, in addition to the advanced water purification.

  • PDF

미량오염물질 관리를 위한 산화 및 흡착 기반 하수 방류수 강화처리 기술의 연구 동향 및 시사점 (Enhanced sewage effluent treatment with oxidation and adsorption technologies for micropollutant control: current status and implications)

  • 최상기;이웅배;김영모;홍석원;손희종;이윤호
    • 상하수도학회지
    • /
    • 제36권2호
    • /
    • pp.59-79
    • /
    • 2022
  • Conventional wastewater treatment plants (WWTPs) do not fully remove micropollutants. Enhanced treatment of sewage effluents is being considered or implemented in some countries to minimize the discharge of problematic micropollutants from WWTPs. Representative enhanced sewage treatment technologies for micropollutant removal were reviewed, including their current status of research and development. Advanced oxidation processes (AOPs) such as ozonation and UV/H2O2 and adsorption processes using powdered (PAC) and granular activated carbon (GAC) were mainly discussed with focusing on process principles for the micropollutant removal, effect of process operation and water matrix factors, and technical and economic feasibility. Pilot- and full-scale studies have shown that ozonation, PAC, and GAC can achieve significant elimination of various micropollutants at economically feasible costs(0.16-0.29 €/m3). Considering the current status of domestic WWTPs, ozonation and PAC were found to be the most feasible options for the enhanced sewage effluent treatment. Although ozonation and PAC are all mature technologies, a range of technical aspects should be considered for their successful application, such as energy consumption, CO2 emission, byproduct or waste generation, and ease of system construction/operation/maintenance. More feasibility studies considering domestic wastewater characteristics and WWTP conditions are required to apply ozonation or PAC/GAC adsorption process to enhance sewage effluent treatment in Korea.

하수처리수를 활용한 중수도의 도입방안 연구 (A study on the device introduction of wastewater reclamation system a treated sewage)

  • 박노삼;박상현
    • 한국산업융합학회 논문집
    • /
    • 제2권2호
    • /
    • pp.23-33
    • /
    • 1999
  • After studying several methods of the application a device of a treated sewage in anticipation of the future shortage of the duty of water, we could have some conclusion as the following : Advanced treatment systems arc essential prerequisites in reusing a treated sewage. And in a short term, the application of reusing a treated sewage should go first to new building areas near the sewage but for the long run, it should cover the whole area of Taegu, it is desirable that the pipe line networks which include dual water systems as well as water supply should be spread throughout the whole city. The city authorities have to make every effort to step up publicity activities on this plan to all the citizens and building owners to steadily carry out this project and encourage private constructors to participate with the help of SOC. And for the long run, it is desirable that the application of reusing a treated sewage should be obligatory.

  • PDF