• 제목/요약/키워드: Adjustable dental impression tray

검색결과 10건 처리시간 0.02초

치과용 스캐닝 시스템의 개발과 가변형 상악용 트레이의 재현성 (Development of Dental Scanning System and Reproduction of Adjustable Upper Dental Impression Tray)

  • 차영엽;엄상호
    • 제어로봇시스템학회논문지
    • /
    • 제16권3호
    • /
    • pp.300-304
    • /
    • 2010
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable upper dental impression tray. The metal stock, individual, and new adjustable stock trays were used for 30 stone casts(10 casts each) duplicated a resin master model of maxilla. The dental stone was poured in a vinyl polysiloxane impressions and allowed to set for on hour. The master model and the duplicated casts were digitized using an dental scanning system. The distance between the reference points were measured and analyzed on the graphic image of 3D graphic software of CATIA. The statistical significance of the differences between the groups was determined by a two-way ANOVA. There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch. The adjustable upper stock tray showed clinically acceptable accuracies of the study cast produced by them.

스캐닝 시스템과 하악용 가변형 트레이의 재현성 (Scanning System and Reproduction of Adjustable Lower Dental Impression Tray)

  • 차영엽;엄상호
    • 제어로봇시스템학회논문지
    • /
    • 제17권3호
    • /
    • pp.254-257
    • /
    • 2011
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable lower dental impression trays. Multiple impressions of a resin master model were made with custom, stock and new adjustable trays and vinyl polysiloxane impression material. The lower master model and resulting cast were compared using an dental scanning system. Each 3D image was superimposed onto the lower master model image and analyzed with custom software. Multiple measurements of the lower master model and casts were analyzed to determine the accuracy of tray types.

가변형 치과 인상용 트레이의 적합도에 관한 예비연구 (A Preliminary Study on the Fitness of Adjustable Dental Impression Trays)

  • 김민정;오상천;동진근
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.83-93
    • /
    • 2005
  • This study was designed to investigate the fitness of adjustable dental impression trays. The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. A hundred dental students(male:50, female:50) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. The results obtained were as follows : 1. Uniform impression material thickness was achieved by controlling the width of the tray using stops and beveled guides. 2. In the upper tray, the impression material thickness was measured to be rather great showing thickness of the labial vestibule 8.3 mm and the midpalatal part 8.6 mm. 3. In the lower tray, length of the impression material of the labial vestibule of first, second premolar contact point was 7.8 mm, and thickness of the lingual part of premolars(1.8 mm) and molars(1.9 mm) showed small values. 4. In the lower tray, the impression material thickness of the buccal shelf area(0.2 mm) and the retromolar pad area(0.6 mm) was measured to be too small.

유지형태에 따른 가변형 치과 인상용 트레이의 유지력에 관한 연구 (RETENTIVE FORCE OF ADJUSTABLE DENTAL IMPRESSION TRAYS WITH DIFFERENT RETENTION FORMS)

  • 송기범;김성록;박광수;김유리;동진근
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.15-29
    • /
    • 2005
  • Statement of problem. The adjustable dental impression trays were made for being adjusted their width automatically along the width of dental arch. Purpose. The purpose of this study was to investigate the best retentive form of adjustable dental impression tray, and so to make it a more satisfactory product. Material and methods. The eight pairs of adjustable trays were made of ABS(acrylonitrile butadiene styrene) with different distribution of holes and with or without the rim on the border area of them. The experiment was done with the horse-shoe shaped metal plate to pull out the set impression body from the tray, and the tray jig which was made for holding the tray on a lower part of Universal Testing Machine(UTM, Zwick Z020, Zwick Co., Germany). After the impression in the tray was allowed to set four minutes, a tensile force was applied at right angles to the tray which had been previously seated on the jig. The force was applied to measure a maximum retentive force by use of a UTM at a constant strain rate of 100mm per minute. A 2-factor analysis of variance (p<.05) was used to determine whether differences existed among distribution of retentive holes and between rim existing and not. Results. 1 The retentive force of the upper and lower resin tray with 2mm holes on the tray border was highest(25.83/24.98kg). (p<.05) 2. As the tray had more retentive holes, it was less retentive. 3. There was no significant difference in the retentive force of the varied hole intervals in the case of distributing all the area. (p>.05) 4. The rimless trays were more retentive generally, than the rimmed trays except 2 case: upper tray group-all area / 2 mm, intervals and lower tray group-margin only / 2 mm, intervals.(p<.05) 5. Most of the adjustable trays were showed higher retentive force than perforated metal tray except the lower group that perforated on the all area at intervals of 2 mm.

합성수지 재료에 따른 가변형 치과 인상용 트레이의 유지력에 관한 연구 (Retentive Force of Adjustable Dental Impression Trays with Different Synthetic Resin Materials)

  • 이인섭;이진한;김유리;동진근
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.11-21
    • /
    • 2006
  • The adjustable dental impression trays were made for being adjusted their width automatically along the width of patient's dental arch. The purpose of this study was to investigate the retentive force of adjustable dental impression trays made of different synthetic resin materials. Three pairs of adjustable trays were made of ABS(acrylonitrile butadiene styrene) synthetic resin, polyurethane synthetic resin and polycarbonate synthetic resin with a hole and without a rim on the border area of them. The experiment was done with the horse-shoe shaped metal plate to pull out the set impression body from the tray jig which was made for holding the tray on the lower part of Universal Testing Machine(UTM, Zwick Z020, Zwick Co., Germany). After the alginate impression in the tray was allowed to set four minutes, a tensile force was applied at right angles to the tray which had been previously seated on the jig. The force was applied to measure a maximum force by use of UTM at a constant strain rate 100mm per minute. The results obtained in this study were as follows : 1. The upper trays were showed higher retentive force than lower trays in three tray materials. 2. There was no significant difference in the retentive force of the tray materials(p>0.05).

가변형 치과 인상용 트레이로 제작된 모형의 재현성 (Accuracy of Stone Cast Produced by Adjustable Dental Impression Tray)

  • 박광수;동진근;심헌보;오상천
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.317-328
    • /
    • 2006
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and Methods: Metal stock tray and adjustable stock trays were used for 40 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a allginate impressions and allowed to set for one hour. The casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software (CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results: There were no significant differences between the accuracies of the adjustable stock tray and the master model except anterior arch width of the upper arch and the diagonal arch length and arch length(one side) of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study casts produced by them.

한국인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구 (THE FITNESS OF ADJUSTABLE DENTAL IMPRESSION TRAYS ON THE KOREANS)

  • 김태영;동진근;조혜원
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.477-487
    • /
    • 2006
  • Purpose : this study was to evaluate the fitness of adjustable dental impression trays on the Koreans : the trays used in the previous study by Kim et al. as part of the dental adjustable tray development project were improved and modified. Material and method: The patterns of tray were made through CAD-CAM process, and a simple silicone-base molds were made from them. The trial products were reproduced by pouring polyurethane into these molds. 30 male students(Wonkwang University, Dental College) and 30 female students (Wonkwang Health Science College, Department of Dental Hygiene) were selected and Reversible hydrocolloid impression materials were used for this study. The fitness of the trays was evaluated by measuring the width and length of impression materials of each measurement sites. Results and conclusion : 1. In adapting the trays inside the mouth, a uniform width of impression material(3 $\sim$ 6mm) was obtained in most sites due to the tooth stops and the inclined planes accommodating the width of the tray 2. The thickness of impression material in the central part of the palate was a mean 9.8mm, which turned out to be somewhat thick. 3. In the mandible. the thickness of the impression material in the lingual side inferior to the contact point of the 1st and 2nd molars was 2.7mm, and the thickness of the material in the lingual side of the rearmost margin was 2.5 mm. The thickness of the impression material of these areas was relatively thin.

가변형 치과 인상용 트레이로 제작된 모형의 재현성에 관한 연구 (ACCURACY OF STONE CAST PRODUCED BY ADJUSTABLE DENTAL IMPRESSION TRAY)

  • 엄상호;오상천
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.453-465
    • /
    • 2005
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and methods: The metal stock, individual, and adjustable stock trays were used for 60 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a vinyl polysiloxane impressions and allowed to set for one hour. The master model and the duplicated casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software(CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results : There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch and the diagonal arch length and arch length on one side of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study cast produced by them.

중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구 (A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese)

  • 강한중;이진한;최종인;이인섭;동진근
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.175-184
    • /
    • 2008
  • 연구목적: 본 연구는 가변형 트레이 개발의 일환으로 그 시제품을 제작하고 비가역성 수성 콜로이드 인상재를 사용하여 중국인과 일본인에서 인상채득 시 트레이의 구강 내 적합성를 알아보고자 하였다. 연구재료 및 방법: 가변형 트레이는 한국 성인 악궁의 크기 분석결과를 기본으로 하여 설계하였으며, 먼저 CAD-CAM 작업을 통하여 견본 모형을 제작한 후, 이를 똑같이 복제한 실리콘 간이금형을 만들었다. 그리고 이 금형에 polyurethane을 주입하여 다수의 시제품을 완성하였다. 시제품을 이용하여 중국인으로는 상해 제2의과대학교 구강의학원 학생 60명 (남자 30명, 여자 30명)을 대상으로 하였고, 일본인으로는 일본 구마모토 고등학교 졸업생 60명 (남자 30명, 여자 30명)을 대상으로 인상채득을 실시하고, 측정부위별로 인상체의 두께와 길이를 측정한 후 통계처리를 하여 그 적합성을 평가하였다. 결과: 1. 중국인과 일본인 모두 스탑과 경사면에 의해 트레이의 폭이 적절히 조절되어 대체적으로 3-6mm의 균일한 인상체의 두께를 얻을 수 있었다. 2. 중국인의 상악 트레이에서는 전치 순측 변연부에서 두께가 6.2mm, 견치 순측 변연부에서 두께가 5.9mm, 구개부 중앙은 10.5 mm, 구개부 후방은 9.7mm 높이로 비교적 인상체의 두께가 크게 측정되었다. 3. 중국인의 하악 트레이에서는 제1, 2소구치 접촉점 설측 변연부에서 인상체의 길이가 8.9mm, 전치 설측 변연부에서 7.2mm로 길게 나타났으며, 견치 순측 6.8mm, 소구치 순측 7.0mm로 인상체의 두께가 크게 측정되었다. 4. 일본인의 상악 트레이에서는 전치 순측 변연부에서 두께가 7.4mm, 견치 순측 변연부에서 7.7mm, 구개부 중앙은 9.1mm 높이로 인상체의 두께가 비교적 크게 측정되었다. 5. 일본인의 하악 트레이에서는 견치 순측 7.4mm, 제1, 2소구치 접촉점 순측 변연부 8.4mm로 인상체의 두께가 크게 측정되었다. 결론: 본 가변형 치과 인상용 트레이는 한국인 모형 계측치를 바탕으로 설계되어 한국인에서 적합성이 우수하며, 본 실험의 결과 중국인과 일본인에서도 적합성이 좋아 본 트레이를 범용하여 쉽고 정확한 인상채득을 할 수 있을 것이다.

백인과 흑인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구 (Fitness of Adjustable Dental Impression Trays on the Caucasian and African American)

  • 박용석;김유리;오상천;이인섭;동진근
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.185-192
    • /
    • 2008
  • 연구목적: 본 연구는 가변형 트레이 개발의 일환으로 그 시제품을 제작하고 비가역성 하이드로콜로이드 인상재를 사용하여 백인과 흑인에 서 인상채득시 트레이의 구강내 적합성를 알아보고자 하였다. 연구재료 및 방법: 가변형 트레이는 한국 성인 악궁의 크기 분석결과를 기본으로 하여 설계하였으며, CAD-CAM 작업을 통하여 견본 모형을 제작한 후 이를 이용하여 실리콘 간이 금형을 만든후 시제품을 제작하였다. 제작된 시제품을 이용하여 국내에 거주하는 백인 60명 (남자 30명, 여자 30명)과 흑인 60명 (남자 30명, 여자 30명)의 인상을 채득한 후 측정부위별로 인상체의 두께와 길이를 측정하여 그 적합도를 평가하였다. 결과: 1. 스탑과 경사면에 의해 트레이의 폭이 적절히 조절되어 균일한 인상체의 두께를 얻을 수 있었다. 2. 백인의 상악 트레이에서는 구개부 중앙이 13.0mm, 구개부 후방이 7.4mm로 비교적 인상체의 두께가 크게 측정되었다. 3. 백인의 하악 트레이에서는 전치 설측 기저부에서 인상체의 길이가 6.7mm로 길게 나타났으며 협측 제1,2 소구치 접촉점에서 폭이 6.7mm로 측정되었다. 설측 후방에서 폭이 2.9mm, 길이는 2.8mm로 조금 작게 측정되었다. 4. 흑인의 상악 트레이에서는 전치 순측 기저부에서 폭이 11.0mm, 구개부 중앙은 12.0mm, 구개부 후방은 11.0mm로 크게 측정되었으며 최후방 변연에서는 제2 대구치에서 후방 변연까지의 거리가 0.8mm로 작게 측정되었다. 5. 흑인의 하악 트레이에서는 전치 순측 기저부에서 폭이 9.2mm, 견치 순면에서 폭이 8.2mm로 비교적 크게 측정되었으며 최후방 변연에서는 제2 대구치에서 후방 변연까지의 거리가 0.3mm로 작게 측정되었다. 결 론: 이상과 같은 연구에 의해 측정된 값을 참고로 트레이의 변연 길이나 폭을 수정하고, 악궁의 해부학적 형태를 반영한다면, 이 가변형 트레이를 사용하여 백인과 흑인에서도 임상에서 보다 쉽고 정확한 인상채득을 할 수 있을 것이다.