• Title/Summary/Keyword: Adjustable

Search Result 846, Processing Time 0.025 seconds

The Design and Construction of the Nuclear Microprobe (핵 마이크로프로브 설계 및 제작)

  • Woo, Hyung-Ju;Kim, Jun-Gon;Choi, Han-Woo;Hong, Wan;Kim, Young-Seok;Lee, Jin-Ho;Kim, Ki-Dong;Yang, Tae-Gun
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.380-386
    • /
    • 2001
  • A nuclear microprobe system with adjustable precision object slits and a magnetic quadrupole doublet was designed by the beam optics simulation using a first order matrix formalism, and installed in a $30^{\circ}$ beam line connected with KIGAM 1.7 MV Tandem VDG Accelerator. Demagnification factors for x and y axis are calculated to be 25 and 4.9, respectively, and a minimum beam spot side is expected to be about 5 $\mu\textrm{m}$ for 3 MeV proton beams with a current of about 1 nA. A multi-purpose octagonal target chamber has been built to facilitate MeV ion-beam analytical techniques of PIXE, RBS, ERDA, and ion beam micro-machining. It contains X-ray and particle detectors, a zoom microscope, a Faraday cup, a 4-axis sample manipulator and a high vacuum pumping system. The system performance of the nuclear microprobe is now being tested, and automatic manipulator control and data acquisition system will be installed for routine applications of micro ion-beam analytical techniques.

  • PDF

Stereotactic Radiosurgery for Recurrent Glioblastoma Multiforme using Yeungnam Localization Device - Technical note and Clinical trial - (뇌정위적 방사선 절제술에 필요한 위치선정용기구 제작과 치험 2예)

  • Shin, Sei-One;Kim, Sung-Kyu;Kim, Myung-Se;Kim, Oh-Lyong;Cho, Soo-Ho
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.101-105
    • /
    • 1992
  • Authors performed a stereotactic radiosurgery with multiple noncoplanar convergent photon beams of linear accelerator (NELAC-1018 18 MeV, NEC) using a specially designed Yeungnam localization device for two patients with recurrent glioblastoma multiforme. One patient had 2 cm sized and the other 4 cm sized mass on the CT images. After single session of treatment with 15 and 20 Gy, headache was improved in a few days after radiosurgery with no remarkable untoward reactions. Our experience with these two patients were encouraging and we found that our localization device, which is easily adjustable and inexpensive, could be a valuable tool for stereotactic radiosurgery particularly in the treatment of recurrent brain tumor.

  • PDF

Comparison of Optimum Drilling Conditions of Aircraft CFRP Composites using CVD Diamond and PCD Drills (CVD 다이아몬드 및 PCD이 드릴을 이용한 항공용 CFRP 복합재료의 홀 가공성 비교)

  • Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Park, Joung-Man
    • Composites Research
    • /
    • v.24 no.4
    • /
    • pp.23-28
    • /
    • 2011
  • Recently CFRP laminate joints process by bolts and nets are developed rapidly in aircraft industries. However, there are serious drawback during jointing process. Many hole processes are needed for the manufacturing and structural applications using composite materials. Generally, very durable polycrystalline crystalline diamond (PCD) drill has been used for the CFRP hole process. However, due to the expensive price and slow process speed, chemical vapor deposition (CVD) diamond drill has been used increasingly which are relatively-low durability but easily-adjustable process speed via drill shape change and price is much lower. In this study, the comparison of hole process between PCD and CVD diamond coated drills was done. First of all, CFRP hole processbility was evaluated using the equations of hole processing conditions (feed amount per blade, feed speed). The comparison on thermal damage occurring from the CFRP specimen was also studied during drilling process. Empirical equation was made from the temperature photo profile being taken during hole process by infrared thermal camera. In addition, hole processability was compared by checking hole inside condition upon chip exhausting state for two drills. Generally, although the PCD can exhibit better hole processability, hole processing speed of CVD diamond drill exhibited faster than PCD case.

Effect of Work Intensity on Fit Factor and Affecive Quality of Dustproof Mask (작업 강도가 방진 마스크의 밀착도와 감성품질에 미치는 영향)

  • Lee, Jinsil;Cho, Sunhee;Yun, Jungmin;Kim, Min-Sun;Park, Jaekyu;Choe, Jaeho
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.2
    • /
    • pp.301-310
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the effect of work intensity on fit factor and affective quality of the dustproof Background: Among the victims who suffer pneumoconiosis due to the inhalation of toxic substances or the lack of oxygen during the work, the proportion of the victims is larger than the other causes. Wearing a respirator may prevent pneumoconiosis, but it can be hazardous to workers because of the leakage through filters, cartridges, exhaust valves, broken parts, and face-to-face contact. Despite leakage through the contact area between the mask and the face has various causes such as the wearer's activity, sweat accumulation, facial shape, etc., There is a lack of relevant research and regulation compared to developed countries that have already institutionalized the law 30 years ago and give the right to sell through a test Method: The work intensity was adjusted by walking or running at 6km/h and 11km/h on the treadmill, and tasks were defined with reference to the test procedure and the exercise sequence applied in the face leakage test of the dustproof mask. And fit factor was measured objectively using 'Respirator Fit Tester 8038' which measures fit factor calculated by dividing the number of dust present outside the mask by inside the mask. In addition, affective quality was classified by the ease of use, ease of breathing, and ease of wearing, and was measured using the 5-point likert scale questionnaire. Results: There was a significant difference in fit factor, ease of breathing, and wearing convenience according to work intensity and no significant difference in ease of use(${\alpha}=0.01$). And when the work intensity was high, fit factor, ease of breathing, and wearing convenience were all lower than when the work intensity was low. Conclusion: In Korea, it is necessary to consider consideration of the work intensity when testing the leakage rate of the face part for safety certification of the respiratory protective equipment, When developing a mask, it should be possible to maintain high adhesion even under intense, active situation and high temperature conditions by selecting materials, improving the wearing style, and expanding the adjustable range.

Improvement of the Uniformity of Temperature Distribution inside Semiconductor Test Equipment Chamber (반도체 검사 장비의 챔버 내부 온도 분포의 균일성 개선)

  • Lee, Kwang-Ju;Jeong, Kyung-Seok;Park, Sung-Mun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3626-3632
    • /
    • 2010
  • Some design changes were made to enhance the uniformity of temperature distribution inside the chamber of semiconductor test equipment. The design changes include the installation of adjustable airflow controller inside the chamber, the alignment of the centers of heater and match plate, the change in the size and the shape of holes in match plate base, and the addition of new holes of 2 mm diameter in order to allow airflow directly to the temperature sensors. In order to verify their effects, the temperature distributions inside the chambers were measured using 32 RTD sensors before and after the design changes. The temperature distributions were in the ranges of 87.1 to $91.5^{\circ}C$ ($90{\pm}2.9^{\circ}C$) and 89.5 to $90.8^{\circ}C$ ($90{\pm}0.8^{\circ}C$) before and after the design changes, respectively. The above temperature distribution after design changes was maintained for longer than 15 minutes, which satisfied the target temperature range of $90{\pm}1^{\circ}C$ for longer than 10 minutes.

The Effect of Pelvic Traction and Muscle Energy Technique on Static Standing Balance in Hemiplegia Patients (골반견인과 근 에너지기법이 편마비 환자의 정적선자세에 미치는 영향)

  • Bae, Jun-Ho;Han, Jin-Tae;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.4
    • /
    • pp.537-557
    • /
    • 2005
  • The purpose of this study was to investigate the effect of pelvic traction and muscle energy technique(MET) for hemiplegic patients on static standing balance. The scale for static standing balance is measured by using mean balance(%), frequence(Hz), sway area($mm^2$), sway path(mm), max sway velocity(mm/s), ant/post sway angle($^{\circ}$), lateral sway angle($^{\circ}$), sway number, change of pelvic height is measured in relation to the height of ASIS and PSIS. The subjects of this study were thirty hemiplegic patients: 15men and 15 women, with an average ages of 50.80 years. The thirty subjects were divided into 3 group of 10 at random ; ten subjects had pelvic traction after bobath therapy (the pelvic traction group), ten subjects had muscle energy technique after bobath therapy (the MET group), and ten subjects had only bobath therapy (the control group). Static standing balance was measured using BPM (balance performance monitor; data print software version 5.3), pelvic height was measured using height measuring with an adjustable horizontal arm. In order to assure the statistical significant of the result, an one-way ANOVA, the paired t-test, and a person's correlation were applied at the.05 level of significance. The results of this study were as follows: 1) The change in pelvic height were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 2) The change in affected and non-affected on weight bearing were not statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p>.05). 3) The change in frequency were statistically significant between the MET group, the control group and the pelvic traction group on pre-treatment and post-treatment(p<.05). 4) The change in sway area were statistically significant between the MET group, the control group and the pelvic traction group on pre-treatment and post-treatment(p<.05). 5) The change in sway pa1h were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 6) The change in max sway velocity were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 7) The change in ant/post sway angle were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 8) The change in lateral sway angle were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 9) The change in sway number were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). In conclusion, there was a difference between the experimental group and the control group. In the future, we have to study continuously about pelvic traction and muscle energy technique in hemiplegic patients.

  • PDF

Correlation of Practice and Cognition for Women's Skin Care Behavior (여성의 피부건강행위에 대한 인식도와 실천도의 상관관계분석)

  • Choi Eun-Young;Oh Hyun-Ju;Baek Seung-Hwa
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.4 no.2
    • /
    • pp.273-284
    • /
    • 2000
  • The objective of this study consists on clarifying what factors are influenced upon skin care behavior using fender's Health Promotion Model, widely used to anticipate practices of health care behavior for women with keen interest in skin care and then manifesting their correlations from July 1 to August 22, 1998, on 159 women interested in skin care. A subvariable included practice of skin care behavior and independent variables include general characteristics, health fitness, the level of agreement with the advantages of the perceived skin care behavior, the level of cognition of the necessity for skin care behavior The data collected processed with ANOVA and multiple regression analysis to clarify what factors among other independent variables have the most powerful effects upon skin care. The resultant findings were revealed, as follows : 1. In health care behavior among skin care behavior,'full ingestion of water' represented the highest value by 3.45 points, 2. The testees of this study had for the most part a higher level of cognition for the necessity for skin care behavior than for practice of skin care behavior. The more points they have for cognition of the necessity for skin care behavior, the more points they present for practice of skin care behavior. 3. From the perspective of the relationship between sociometic factors on the testees and their skin care behavior, the higher level married women were on (p<0.05) and the more points they have for economic status, the higher points were reflected . 4. The correlations between the testees' recognition or perception factors and points for practice of skin health state showed the higher points than the group who thought that they did not know their own skin health state (p<0.05). The higher the points of skin care fitness (p<0.0001), the higher the points of self-awareness (p<0.0001) 5. The factors that had the most powerful influence upon cognition and practice of women's skin care behavior were found, with statistical significance, to be adjustable factors such as age, smoking, drinking habit, economic status, etc. and points of cognition of the necessity for skin care behavior.

  • PDF

Micro-Hydropower System with a Semi-Kaplan Turbine for Sewage Treatment Plant Application: Kiheung Respia Case Study (하수처리장 적용을 위한 Semi-카플란 수차가 장착된 마이크로수력발전 시스템: 기흥레스피아 사례)

  • Chae, Kyu-Jung;Kim, Dong-Soo;Cheon, Kyung-Ho;Kim, Won-Kyoung;Kim, Jung-Yeon;Lee, Chul-Hyung;Park, Wan-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.363-370
    • /
    • 2013
  • Small scale hydropower is one of most attractive and cost-effective energy technologies for installation within sewage treatment plants. This study was conducted to evaluate the potential of a semi-kaplan micro-hydropower (MHP) system for application to sewage treatment plants with high flow fluctuations and a low head. The semi-kaplan MHP is equipped with an adjustable runner blade, and is without a guide vane, so as to reduce the incidence of mechanical problems. A MHP rating 13.4 kWp with a semi-kaplan turbine has been considered for Kiheung Respia sewage treatment plant, and this installation is estimated to generate 86.8 MWh of electricity annually, which is enough to supply electricity to over 25 households, and equivalent to an annual reduction of 49 ton $CO_2$. The semi-kaplan turbine showed a 90.2% energy conversion efficiency at the design flow rate of 0.35 $m^3/s$ and net head of 4.7 m, and was adaptable to a wide range of flow fluctuations. Through the MHP operation, approximately 2.1% of total electricity demand of Kiheung Respia sewage treatment plant will be achievable. Based on financial analysis, an exploiting MHP is considered economically acceptable with an internal rate of return of 6.1%, net present value of 15,539,000 Korean Won, benefit-cost ratio of 1.08, and payback year of 15.5, respectively, if initial investment cost is 200,000,000 Korean Won.

Design and performance evaluation of fish-luring system using the air-cooled LED lamp for jigging and angling boat (채낚기 어선용 공랭식 LED 집어시스템의 설계 및 성능평가)

  • Bae, Bong-Seong;Park, Byoung-Jae;Jeong, Eui-Cheol;Yang, Yong-Su;Park, Hae-Hoon;Chun, Young-Yull;Chang, Dae-Soo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.45 no.2
    • /
    • pp.85-95
    • /
    • 2009
  • The fishing lamp is a fishing gear that gathers fish at night. But the cost of oil, which is used to light fishing lamp, has been risen significantly up to 30-40% of total fishing costs. Therefore it is very urgent to develop an energy economical fishing lamp in order to solve the business difficulties of fisheries. Under this background, this research aims at developing a fishing lamp for squid jigging and hairtail angling fishery using the LED, which has excellent energy efficiency and durability. The LED fishing lamp developed can be controlled to fix a fit direction of fish shoal deep because a fishing lamp can be adjustable up and down directions. One unit of fishing lamp has about an 80Watt capacity and the frame of fishing lamp is made of aluminium to emit generated heat of LED to outside. The LED lamp developed was highly durable, only 5.7% of emitting efficiency decreased for 18 months. The illuminance of a unit LED lamp was 2,070lux at 1m and 21lux at 10 m distance, and the intensity of LED lamp system emitted 2,580lux and 400lux at the respective distances. After development of this fishing lamp, 100 units are installed on operating fishing vessels. Experimental results show that energy consumption of squid jigging and hairtail angling was reduced by 40% and 87%, respectively. In conclusion, our methods showed elevated fishing power, compared with traditional fishing method: 37.7% for squid jigging and 24.5% for hairtail angling.

CPW-fed Compact Slot Antenna Matched by T-shaped Stub (T형 스터브로 정합된 CPW급전 소형 슬롯 안테나)

  • Lee, Jong-Ig;Yeo, Jun-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3140-3145
    • /
    • 2012
  • In this paper, a design method for a compact slot antenna fed by a coplanar waveguide (CPW) is studied. A T-shaped tuning stub is inserted inside a narrow rectangular slot and the slot is impedance matched to the CPW feedline by adjusting the width, length, and position of the stub. The resonance frequency is adjustable by the slot length and the antenna size can be reduced by bending the slot. The resonance frequency and impedance matching property of the compact slot antenna are similar to those of the half-wavelength slot antenna, which enables one to design compact antenna of this type with ease. A compact slot antenna for 2.45-GHz ISM band is designed, fabricated on an FR4 substrate (dielectric constant of 4.4 and thickness of 0.8 mm), and experimentally tested. The measured results agree well with the simulations, which confirms the validity of this study. The fabricated compact slot antenna shows an impedance bandwidth of 200 MHz(2.32-2.52 GHz) for a VSWR < 2, which is suitable for 2.45-GHz ISM band (2.4-2.48 GHz). The measured radiation patterns show ${\infty}$-shaped directional pattern in the E-plane and nearly omni-directional pattern in the H-plane with a peak gain of 2.0 dBi, which are similar to those of a monopole antenna. The proposed antenna is expected to be suitable for the applications as antennas for WLAN, RFID, and mobile handset.