DOI QR코드

DOI QR Code

작업 강도가 방진 마스크의 밀착도와 감성품질에 미치는 영향

Effect of Work Intensity on Fit Factor and Affecive Quality of Dustproof Mask

  • 이진실 (한국생산기술연구원 국가산업융합지원센터) ;
  • 조선희 (한국생산기술연구원 국가산업융합지원센터) ;
  • 윤정민 (한국생산기술연구원 국가산업융합지원센터) ;
  • 김민선 (한국생산기술연구원 국가산업융합지원센터) ;
  • 박재규 (고려대학교 산업경영공학과) ;
  • 최재호 (대진대학교 산업공학과)
  • Lee, Jinsil (Korea National Industrial Convergence Center, Korea Institute of Industrial Technology) ;
  • Cho, Sunhee (Korea National Industrial Convergence Center, Korea Institute of Industrial Technology) ;
  • Yun, Jungmin (Korea National Industrial Convergence Center, Korea Institute of Industrial Technology) ;
  • Kim, Min-Sun (Korea National Industrial Convergence Center, Korea Institute of Industrial Technology) ;
  • Park, Jaekyu (Dept. of Industrial Management Engineering, Korea University) ;
  • Choe, Jaeho (Dept. of Industrial Engineering, Daejin University)
  • 투고 : 2018.05.16
  • 심사 : 2018.06.07
  • 발행 : 2018.06.30

초록

Purpose: The purpose of this study is to investigate the effect of work intensity on fit factor and affective quality of the dustproof Background: Among the victims who suffer pneumoconiosis due to the inhalation of toxic substances or the lack of oxygen during the work, the proportion of the victims is larger than the other causes. Wearing a respirator may prevent pneumoconiosis, but it can be hazardous to workers because of the leakage through filters, cartridges, exhaust valves, broken parts, and face-to-face contact. Despite leakage through the contact area between the mask and the face has various causes such as the wearer's activity, sweat accumulation, facial shape, etc., There is a lack of relevant research and regulation compared to developed countries that have already institutionalized the law 30 years ago and give the right to sell through a test Method: The work intensity was adjusted by walking or running at 6km/h and 11km/h on the treadmill, and tasks were defined with reference to the test procedure and the exercise sequence applied in the face leakage test of the dustproof mask. And fit factor was measured objectively using 'Respirator Fit Tester 8038' which measures fit factor calculated by dividing the number of dust present outside the mask by inside the mask. In addition, affective quality was classified by the ease of use, ease of breathing, and ease of wearing, and was measured using the 5-point likert scale questionnaire. Results: There was a significant difference in fit factor, ease of breathing, and wearing convenience according to work intensity and no significant difference in ease of use(${\alpha}=0.01$). And when the work intensity was high, fit factor, ease of breathing, and wearing convenience were all lower than when the work intensity was low. Conclusion: In Korea, it is necessary to consider consideration of the work intensity when testing the leakage rate of the face part for safety certification of the respiratory protective equipment, When developing a mask, it should be possible to maintain high adhesion even under intense, active situation and high temperature conditions by selecting materials, improving the wearing style, and expanding the adjustable range.

키워드

참고문헌

  1. Arthur T. Johnson, Cathryn R. Dooly, David M. Caretti, Michal Green, William H. Scott, Karen M. Coyne, Manjit S. Sahota & Benhur Benjamin. 1997. "Individual Work Performance During a 10-Hour Period of Respirator Wear." American Industrial Hygiene Association Journal 58(5):345-353 https://doi.org/10.1080/15428119791012702
  2. Bergman, M. S., Zhuang, Z., Hanson, D., Heimbuch, B. K., McDonald, M. J., Palmiero, A. J., ... Wander, J. D.. 2014. "Development of an Advanced Respirator Fit-Test Headform." Journal of Occupational and Environmental Hygiene 11(2):117-125. http://doi.org/10.1080/15459624.2013.816434.
  3. Canadian Standards Association. 1993. "Z94.4-93: Selection, use and care of respirators."
  4. Caretti DM and Gardner PD. 1999. "Respirator fit factor performance while sweating." American Industrial Hygiene Association Journal 60(1):84-8. https://doi.org/10.1080/00028899908984425
  5. David Claudio, Maria A. Velazquez, Wilfredo Bravo-Llerena, Gül E. Okudan & Andris Freivalds. 2015. "Perceived Usefulness and Ease of Use of Wearable Sensor-Based Systems in Emergency Departments." IIE Transactions on Occupational Ergonomics and Human Factors 3(3-4):177-187. https://doi.org/10.1080/21577323.2015.1040559
  6. Don-Hee Han, Sang Sik Woo and Hoi-Myung Jung. 2004. "Evaluation of Particulate Respirators by Total Inward Leakage(TIL) and Validity of the Certification Regulation for TIL." Journal of Korean Society of Occupational Environmental Hygiene 14(3):213-220.
  7. Don-Hee Han. 1999. "Fit Testing for Respirators and Development of Anthropometric Test Panels." Journal of Korean Society of Occupational Environmental Hygiene 9(1):1-13.
  8. Jessica Hauge, Marc Roe, Lisa M. Brosseau and Craig Colton. 2012. "Real-time fit of a respirator during simulated health care tasks." Journal of Occupational and Environmental Hygiene 9(10):563-71. https://doi.org/10.1080/15459624.2012.711699
  9. Jeong-Hee Lee, Sang-Seok Nam, Hun-Young Park, Jeong-Won Kim, Woo-Sub Sun. 2014. "A comparison of the energy and blood lactate concentration during exercise on magnetic treadmill and general treadmill." The Korea Journal of Sports Science 23(2):969-982.
  10. Jung-Hyun Kim PhD, Tianzhou Wu MS, Jeffrey B. Powell MS, Raymond J. Roberge MD, MPH. 2016. "Physiologic and fit factor profiles of N95 and P100 filtering facepiece respirators for use in hot, humid environments." American Journal of Infection Control 44(2):194-8. https://doi.org/10.1016/j.ajic.2015.08.027
  11. Kolesar ES Jr, Cosgrove DJ, de la Barre CM and Theis CF. 1982. "Comparison of respirator protection factors measured by two quantitative fit test methods." Aviation, Space and Environmental Medicine 53(11):1116-22.
  12. Korea Occupational Safety & Health Agency. 2018. 2017 Survey of occupational accidents and diseases.
  13. Min Cheol Kim, Hyun Tae Kim and Kyoo Won Lee. 1998. "Development and Performance Evaluation of Air-Supplied Mask." Clean Technology 4(1):60-67.
  14. Ministry of Employment and Labor. 2017. Notification of the Safety Certification about Protective Equipment
  15. National Institute for Occupational Safety and Health. 1987. "Guide to industrial respiratory protection." DHHS/NIOSH Pub. No. 87-116.
  16. Roberge RJ, Kim JH and Coca A.. 2012. "Protective facemask impact on human thermoregulation: an overview."The Annals of Occupational Hygiene 56(1):102-112. https://doi.org/10.1093/annhyg/mer069
  17. Young-ki Hong. 2013. "Functional Finishing of Nonwoven Filter for Dust-proof/Medical Masks by Corona Discharging Treatment." Textile Coloration and Finishing 25(3):232-239. https://doi.org/10.5764/TCF.2013.25.3.232