• Title/Summary/Keyword: Actual discharge

Search Result 269, Processing Time 0.03 seconds

High Voltage Nano-Pulse Generator for Industrial Waste Water Treatment (폐수 처리용 고전압 나노 펄스 발생기)

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Kwon, O-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.311-318
    • /
    • 2001
  • The application of a pulsed power system is being extended to a environmental and industrial fields. The non-dissolution waste water pollutants from industrial plants can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The nano-pulse generator with a magnetic switch has been developed. Its corona current in load can be adjusted by pulse width and repetition rate. we investigated the performance of the nano-pulse generator using the dummy load which is composed of resistor and capacitor equivalent to the actual reactor. This paper descibes the electrical characteristics of the nano-pulse generator that produces a 300 ns pulse at maximum repetition rate of 400 pps with a voltage of 40 kV across a $640{\Omega}$ load. In this paper we briefly discuss a configuration of system and test results.

  • PDF

Development of a Metering Device for a Garlic Clove Planter

  • Choi D. K.;Cho S. C.;Park S. H.;Kim J. Y.;Kim S. H.;Kim C. K.
    • Agricultural and Biosystems Engineering
    • /
    • v.5 no.2
    • /
    • pp.45-49
    • /
    • 2004
  • Objective of the study was to develop a garlic clove metering device. The metering device consisted of a drum, a bucket and a bucket cover. A garlic clove simulator was designed to simulate motions of garlic cloves in the metering device. Simulation was performed using a multibody dynamic analysis program, RecurDyn version 5.1. Physical properties of garlic cloves such as mass and center of gravity were determined using 3D CAD modeler, IDEAS version 10.0. In order to compare the results of the simulation with actual movement of a garlic, movement of garlic clove was photographed by a high speed camera. A prototype metering device was built and tested under various metering speeds and metering guide angles. At the 12 rpm metering speed, rate of single-clove-discharge was $90.0\%$ and missing rate $1.3\%$ at $5^{\circ}$.

  • PDF

Effect of soil physical properties on infiltration rate

  • Sajjadi, Sayed-Abdul-Hamid;Mirzaei, Maryam;Nasab, Afsaneh Fayyaz;Ghezelje, Amin;Tadayonfar, Gholamreza;Sarkardeh, Hamed
    • Geomechanics and Engineering
    • /
    • v.10 no.6
    • /
    • pp.727-736
    • /
    • 2016
  • Excessive rainfall can cause runoff flows over the soil surface and as a consequence some amount of water will infiltrate into the soil. From a hydrologic modeling perspective it is necessary to estimate infiltration rate in order to calculate the actual runoff discharge. There are many parameters that can affect the infiltration rate such as soil texture, moisture and compaction. However, the most common equations used in hydrological calculations for estimating the infiltration rate do not consider the soil properties directly and estimate infiltration rate without any soil properties expressions. The purpose of this research was to investigate the relations between infiltration rate and soil texture, moisture and compaction. To achieve this purpose an experimental study was performed to show the effect of soil properties and their relations on infiltration rate by using non-linear regression.

Study on Non-Value-Added Nursing Activities in a Tertiary Hospital (일 병원의 비부가가치 간호활동에 관한 연구)

  • Kim, Mi-Young;Park, Sung-Ae
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.17 no.3
    • /
    • pp.315-326
    • /
    • 2011
  • Purpose: Purposes of this study were to identify non-value-added nursing activities (NVANAs) and to estimate the amount of time spent on NVANAs among total nursing activities. Methods: Non-value-added nursing activities were identified though the use of a focus group. The nurses in the focus group were nurses working in a tertiary hospital. They discussed possible activities that could be NVANAs. Based on the focus group discussion, a pilot study was done to examine the actual occurrence of NVANAs in clinical settings. Results: The focus group discussion showed that NVANAs occurred in ten categories of nursing performances including communication with physicians, communication with other departments, medications, equipment/supplies, nursing records, tests, admission, discharge, and transfer. Direct nursing activities accounted for 35.5% of total nursing activities while indirect nursing activities accounted for 64.5%. Of indirect nursing activities, 16% were NVANAs. Most NVANAs were related to communication and equipment/supplies. Conclusions: To improve the quality and efficiency of nursing activities, it is necessary to identify NVANAs and their causes. Results of this study suggest that improvement in the work process and nursing unit structure, support for equipment/supplies, and effective communication are needed to reduce NVANAs in tertiary hospitals in Korea.

Three-Dimensional Analysis on Induction Port and In-cylinder Flow for Various Valve Lifts in an SI Engine (SI 엔진의 밸브 리프트에 따른 흡입 포트 및 실린더내 정상 3차원 유동장 해석)

  • Kim, Y.N.;Lee, K.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.5
    • /
    • pp.82-89
    • /
    • 1995
  • The three-dimensional fluid motion through the intake port and cylinder of a single DOHC SI engine was investigated with a commercial computational fluid dynamics simulation program, STAR-CD. This domain includes the intake port, intake valves and combustion chamber. Steady induction port flows for various valve lifts have been simulated for an actual engine configuration. The geometry was obtained by direct interface with a three-dimensional CAD software for complicated port and valve shape. The computational grid was generated using the commercial preprocessor ICEM CFD/CAE. Detailed procedures were presented on the generation of the geometry and the block-structured mesh. A standard k-${\varepsilon}$ turbulent model was applied to consider the complexity of the geometry and the fluid motion. The global flow patterns and the distributions of various quantities, such as pressure, velocity magnitude around the valve seat etc., were examined. The computational results, such as mass flow rate, discharge coefficient etc., for various valve lifts were compard with the experimental results and the computational results were found in good agreement with the experiment.

  • PDF

Discrete Element Method for Defining the Dynamic Behavior and Abrasion of Gravel in Mixer Trucks during Mixing and Discharging (이산 요소법을 이용한 골재 입자의 혼합 및 배출 시 골재 거동 및 강판 마모에 관한 연구)

  • Ryu, Seung-Hun;Woo, Ho-Kil
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.34-41
    • /
    • 2020
  • Ready-mixed concrete is unconsolidated concrete typically transported to construction sites by using mixer trucks. A proper rotation of concrete is necessary to prevent its solidification in mixer trucks during transport: in accordance with the manufacturing method and quality inspection prescribed in KSF4009, this movement is maintained after the manufacturing of concrete in professional production plants and the addition of water, solid materials, and admixtures. Unfortunately, mixer truck parts wear out over long periods of time. In order to improve the wear resistance of the main part of mixer trucks, we used a steel plate with good wear resistance or partially added a reinforcement plate. In this study, we first tested the properties of concrete (as required for the DEM), and then carried out mixing and discharge simulations to define the actual operating conditions of mixer trucks. For each condition, we calculated the amount and location of wear. The reliability of our results was finally verified by comparing them with the measurement values. Overall, this study provided basic data for an optimal design of mixer trucks: one that would reduce the vehicles' weight and production costs.

Development of Aging Diagnosis Device Through Real-time Battery Internal Resistance Measurement

  • Kim, Sang-Bum;Lee, Sang-Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.129-135
    • /
    • 2022
  • Currently, the rapid growth of electric vehicles and the collection and disposal of waste batteries are becoming a social problem. The purpose of this paper is to propose a fast and efficient battery screening method through a safe inspection and storage method according to the collection and storage of waste batteries of electric vehicles. In addition, as the resistance inside the waste battery increases, an instantaneous voltage drop occurs, and there is a risk of overcharging and overdischarging compared to the initial state of the battery. Accordingly, there are great difficulties in operation, so the final goal of this study is to develop a device for diagnosing aging through real-time battery internal resistance measurement. Final result As a result of simulation of the internal resistance measurement test circuit through external impedance (AC), the actual simulation value was 0.05Ω, RS = Vrms / Irms => Vrms = 8.0036mV, Irms = 162.83Ma. Substitute the suggested method. The result was calculated as Rs = 0.0495Ω. It is possible to measure up to 64 impedances inside the aging diagnostic equipment that enables real-time monitoring of the developed battery cells, and the range can be changed according to the application method.

Assessment of actual discharge data frequency analysis method applying Bayesian inference (Bayesian 추론을 적용한 실측유량 빈도해석 기법 평가)

  • Kim, Tae-Jeong;Kim, Jang-Gyeong;Kim, Ho-Jun;Song, Jae-Hyun;Kwon, Hyun-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.225-225
    • /
    • 2022
  • 수자원의 계획 및 설계에 활용되는 홍수량 산정 방법은 홍수량 빈도해석 방법과 강우-유출 모형에 의한 방법으로 구분된다. 홍수량 빈도해석에 의한 방법은 홍수량 자료를 직접 빈도해석 하여 확률홍수량을 산정하며 이론적으로 가장 정확한 방법으로 평가된다. 기존의 홍수량 해석은 자료의 제약으로 인하여 실측유량의 직접 빈도해석은 한계가 있었으나 과거부터 국가적으로 수문조사를 수행하여 10년 이상의 실측유량 자료를 확보할 수 있는 수준에 도달하였다. 본 연구는 수위-유량 관계 곡선식을 통하여 안정적으로 확보된 실측유량 자료를 활용하여 홍수량 빈도해석을 수행하였다. 홍수량 빈도해석을 위하여 Bayesian 기법을 적용하여 매개변수를 산정하고 빈도별 홍수량의 불확실성을 정량화하였다. 확률홍수량 산정 결과는 장기간의 강우량 자료를 적용하여 강우-유출모형으로 산정된 홍수량과 근접한 것을 확인하였다. 수문조사를 통하여 장기간의 실측유량 자료를 활용하여 다각적인 관점으로 수문해석을 가능할 것으로 판단된다.

  • PDF

Insulation Characteristics of Dry-air Insulated Switchgear for 72.5 kV Wind Power Generation (72.5 kV 풍력 발전용 Dry-air Switchgear의 절연 특성)

  • Chan-Hee Yang;Jin-Seok Oh;Hee-Tae Park;Young-il Kim
    • Journal of Wind Energy
    • /
    • v.15 no.2
    • /
    • pp.5-9
    • /
    • 2024
  • This paper describes the insulation breakdown characteristics of 72.5 kV dry-air insulated switchgear under development for installation in a wind power generator when a lightning impulse voltage is applied. For this study, the weak point of insulation due to the electric field concentration of the switchgear's internal shape was identified by finite element method (FEM) analysis, and the shape was actually simulated to measure and analyze the polarity of the lightning impulse voltage and the insulation breakdown characteristics according to the gas pressure at dry-air pressures of 0.1 Mpa to 0.45 Mpa. This study derives the maximum electric field with a 50 % discharge probability for each switchgear internal insulation vulnerable point based on the actual test and electrical simulation, which will be useful as reference data for supplementing and changing insulation design in the future.

A Model Experiment Study to Secure the Straight Line Distance between the Air Inlet and Exhaust Section of the Living Room (거실제연설비중 공기유입구와 배출구간 직선거리 확보를 위한 모형실험연구)

  • Saeng-Gon Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.439-450
    • /
    • 2023
  • Purpose: When conducting fire inspections in Korea, there are objects that violate the fire protection regulations that require a straight line distance of more than 5m between the air inlet and the discharge section if the floor area is less than 400m2, and this paper analyzes the reasons and conducts a model experimental study to support the need for related fire protection regulations. Method: Domestic firefighting objects were investigated and confirmed, domestic and foreign papers, policies, and laws and regulations were examined, and spaces with a straight line distance of less than 5m and more than 5m between the air inlet and discharge section were selected and analyzed through model experiments in a living room of less than 400m2 . Result: When examining the domestic fire protection regulations (NFPCNational Fire Perpormance Code), the separation distance between the air inlet and the outlet is more than 5m when the floor area is less than 400m2 , but as a result of the actual investigation, it was confirmed that there are firefighting objects that cannot keep the separation distance. In addition, when a paper review of overseas fire protection regulations for a straight line distance of more than 5m showed that there was no regulation on the straight line distance between the air inlet and the discharge section, the model experiment showed that the discharge speed was better when the straight line distance between the air inlet and the discharge section was more than 5m than when it was less than 5m. Conclusions: In this study, when examining overseas fire laws and regulations by comparing the performance of the fire protection ratio for the straight line distance between the air inlet and the exhaust section, there is no mandatory regulation for the straight line distance, but the domestic fire protection regulations (NFPCNational Fire Perpormance Code) require more than 5m. It is hoped that this will be reflected in the design stage in the future, and a foundation will be laid to reduce the responsibility and burden of fire superintendents.