• Title/Summary/Keyword: Actual Performance

Search Result 3,934, Processing Time 0.027 seconds

A Study on the Performance of Occupational Health Services in Kyung In Areas (산업장에서의 보건관리업무 수행실태에 관한 연구 -경인 지역 산업장을 대상으로-)

  • Cho, Dong-Ran;Kim, Myung-Soon;Ahn, Tae-Sung;Ko, Bong-Ryeon
    • Research in Community and Public Health Nursing
    • /
    • v.4 no.1
    • /
    • pp.25-37
    • /
    • 1993
  • This study was designed to identify the performance of occupational health services of 37 industries located in Kyung in area. The data was collected by a structured questionnaire developed by the Academic society of Community Nursing. This analysis had two factors, one was related to six of the industries, and the other was the actual assignment procedures of the health team members. This study was undertaken from December 4, 1992 to January 21, 1993. The results of the study were as follows: 1. The study group was primarily manufacturing industries which employed 300-1,000 employees. 2. The actual assignment state of occupation health team members with the exception of nurses was not kept to the regulations of the industrial safety health law. 3. The following was the analysis of the performance of occupational health services with two factors: 1). The larger the size of the six industries, the more the performance of health education, health assessment, and health screening. 2) The actual. practice of occupational health team members working environmental measurement, was more frequently performed by a nurse other than health team members together. 4. 1) The subscription rate of the laborers for primary health screening was 94%, and of these 10% had the need of secondary health screening. As a results of the secondary health screening the degrees were 'A' 45%, 'C' 92%, 'R' 21%. Of these degrees 'C', 'R' 4% were follow up cases. 2) 43% of laborers needed special health screening and .of these the subscription rate was 99%. The main item of the special health screening was physical factors. After the special health screening 46% required .follow up, 30% required medical treatment, only reporting 18%, change work 8%, suspension from work place 2%.

  • PDF

Development of Urban Driving Cycle for Performance Evaluation of Electric Vehicles Part II: Verification of Driving Cycle (전기자동차 성능평가를 위한 도심 주행 모드 개발 Part II: 주행 모드 검증)

  • Jeong, Nak-Tak;Yang, Seong-Mo;Kim, Kwang-Seup;Choi, Su-Bin;Wang, Maosen;You, Sehoon;Kim, Hyunsoo;Suh, Myung-Won
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.161-168
    • /
    • 2015
  • Recently, due to various environmental problems such as global warming, increases of international oil prices, exhaustion of resource, a paradigm of world automobile market is rapidly changing from conventional vehicles using internal combustion engine to eco-friendly vehicles using electric power such as EV, HEV, PHEV and FCEV. Generally, in order to measure fuel consumption and pollutant emissions of cars, chassis dynamometer tests are performed on various driving cycles before actual driving test. There are many driving cycles for performance evaluation of conventional vehicles. However, there is a lack of researches on driving cycle for EV. In this study, the urban driving cycle for performance evaluation of electric vehicles was developed. This study is composed of two parts. In the part 1, the urban driving cycle 'GUDC-EV(Gwacheon-city Urban Driving Cycle for Electric Vehicles)' was developed by using driving data, which were obtained through actual driving experiment, and statistic analysis with chronological table. In this paper part 2, in order to verify the developed driving cycle GUDC-EV, virtual EV platforms were configured and simulations were performed with actual driving data using In addition, simulation results were compared with existing driving cycles such as FTP-72, NEDC and Japan 10-15.

Optimization of Heat Transfer Area Distribution for a Hot Water Driven Absorption Chiller (중온수 흡수식 냉동기의 열전달 면적 최적화)

  • 정시영;조광운;이상수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.431-438
    • /
    • 2000
  • The major irreversibilities in absorption chillers are associated with the transfer of heat into and out from the machine and irreversible process inside the machine. By modeling only external irreversibilities(endo-reversible), a model was formulated to predict the ideal performance of a single-effect absorption chiller. Its actual performance including both external and internal irreversibilities was calculated with a in-house simulation program. The optimization of heat transfer area distribution was performed for both endo-reversible cycle and actual cycle. The equation of endo-reversible modeling was found to give about 2times higher cooling capacity than the simulation program. At optimal distribution, it was found that heat transfer area of the evaporator was about 30% of total area, that of the generator was 20%, and the rest 50% was for the absorber and condenser. The system COP for endo-reversible cycle was slightly higher than that for actual cycle. In the case of LiBr-water single-effect absorption chiller, the maximum cooling capacity was obtained near the condition that LMTD is same at all heat exchangers.

  • PDF

Compression strength performance of multi-layer glued columns by using square lumbers produced from domestic small diameter logs (국산 간벌 소경재를 이용한 다중접착접합 기둥부재의 압축강도성능)

  • Shin, Il-Joong;Kim, Yun-Hui;Jang, Sang-Sik
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.533-540
    • /
    • 2011
  • This study is to develop a mulit-layer glued columns for construction of Korean-style houses by using domestic small diameter logs. Dried small square lumber glued each other to develop a multi-layer glued columns and evaluated its performance of strength. Then, predicted the design load of multi-layer glued columns and make a comparison between actual load and design load of multi-layer glued columns. In the results, allowable load by allowable stress of multi-layer glued columns was measured one-third of actual columns load and prediction load was measured less than 10~30% of the actual load. Therefore, muilt-layer glued member has a standard allowable stress of compressive of 13 MPa (Larix leptolepis) and 19 MPa (Chamaecyparis obtusa) when used as columns. Also, using compression strength of small diameter square logs could calculate maximum loads of multi-layer glued member as column.

An Inquire into Test Bed Compositions in Assessing the Security of a Soft Redundancy Sub-Station System with Auto-Restoration (이중화 자동복구 보안기능이 구비된 배전반의 보안성 평가를 위한 테스트베드 구성에 대한 고찰)

  • Choi, Hyeong-Seok;Jin, Chang-Gi;Bae, Gi-Deok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.99-109
    • /
    • 2012
  • Sub-station, key equipment in electric power infrastructure, are being exposed to increasing risk of hacking. For this, soft redundancy sub-station system needs to be formulated with automatic restoration mechanism. For this it is important to assess the reliability of the applicable range of data that are used in actual system operation, as well as the methods and findings of the tests. At the same time performance of soft redundancy system and total security mechanism, which are aligned for the protection of the sub-station, need to be tested. For testing the above-mentioned, this paper presented a viable formation of a soft redundancy practical VPN system within a panel to protect the latter from hacking or cracking incidences, and conducts a test to check if the considered system actually serves the protection function in the actual operation setting, gathering evidence from the data from the testing of the actual performance of the system as well as of emergency scenario simulation operations. Because tested soft-redundancy & restorative sub-station system is expected to be widely applicable for various cases such as Smart-grid or electricity IT system, where VPN with enhanced level of security is required.

Design of the dual-buoy wave energy converter based on actual wave data of East Sea

  • Kim, Jeongrok;Kweon, Hyuck-Min;Jeong, Weon-Mu;Cho, Il-Hyoung;Cho, Hong-Yeon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.4
    • /
    • pp.739-749
    • /
    • 2015
  • A new conceptual dual-buoy Wave Energy Converter (WEC) for the enhancement of energy extraction efficiency is suggested. Based on actual wave data, the design process for the suggested WEC is conducted in such a way as to ensure that it is suitable in real sea. Actual wave data measured in Korea's East Sea (position: $36.404N^{\circ}$ and $129.274E^{\circ}$) from May 1, 2002 to March 29, 2005 were used as the input wave spectrum for the performance estimation of the dual-buoy WEC. The suggested WEC, a point absorber type, consists of two concentric floating circular cylinders (an inner and a hollow outer buoy). Multiple resonant frequencies in proposed WEC affect the Power Ttake-off (PTO) performance of the WEC. Based on the numerical results, several design strategies are proposed to further enhance the extraction efficiency, including intentional mismatching among the heave natural frequencies of dual buoys, the natural frequency of the internal fluid, and the peak frequency of the input wave spectrum.

A Study on Basic Data for the Architectural Plan of Small and medium-sized Local Airports - Focused on Analysis of Airline Demands and the Actual Conditions of Passenger Facilities - (중소형 지방공항의 건축계획을 위한 기초자료 연구 -항공수요 및 여객이용시설 실태 분석을 중심으로-)

  • Park, Chung-Keun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.16 no.3
    • /
    • pp.9-18
    • /
    • 2014
  • Small and medium-sized local airports have suffered from chronic operating deficits due to many factors except for large airports in Incheon, Gimpo, Jeju and Gimhae. These small and medium-sized local airports have currently been degraded to inefficient airports handling the significantly lower airline demand than their carrying capacities. In this context, this study conducted a survey on the actual conditions of the airline demand in small and medium-sized local airports for the last 10 years after the opening of the Korea Train eXpress and investigated the causes and actual conditions of an increase and a decrease in the airline demand. In addition, it analyzed the functionality, convenience and economic feasibility, competition elements in comparison with other means of transportation, and the actual competitive conditions of local airports. It investigated facility improvements through a field visit for local airports and analyzed the performance rate of passenger demands and the use rate of terminal facilities according to a change in the airline demand. This study aimed to provide basic data in the architectural planning field, needed to establish a plan for the airport revitalization of local airports with the results of an analysis on the actual conditions of small and medium-sized local airports.

Effectiveness Analysis of Helicopter Flight Simulator and Actual Flight Training: Focused on Instrument Flight Training (헬리콥터 비행 시뮬레이터와 실 비행훈련과의 효과 분석: 계기비행 훈련을 중심으로)

  • Kim, Sang-chul;Kim, Jong-min
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.28 no.1
    • /
    • pp.75-82
    • /
    • 2020
  • To compare and analyze the differences between flight simulation and actual flight among 130 army helicopter pilot training subjects, the correlation analysis was performed first through t-testing and multiple regression analysis of individual characteristics and flight simulation and actual instrument flight training, which were analyzed significantly in the age (a3) and service classification (a5) of the six verification factors. This has been shown to be significant, with no difference between the flight simulator and the actual flight. Second, in order to study the correlation between aircraft types, the flight evaluation (v1) was analyzed as a dependent variable for the performance of the flight simulator (KUH: s2, UH60: s3, AH-1S: s5, UH-1H: s6), and the results of the multiple regression analysis of the flight simulator evaluation (s1) were analyzed, in contrast, as a dependent variable, and in conclusion, the training of the flight simulator provided statistical data on the possibility of replacing the actual flight training, which is thought to contribute to the orientation, budget reduction and aviation safety of the pilot training.

Effect of Quality Management on Production Performance of Manufacturing Company (품질경영이 제조기업의 생산성과에 미치는 영향 -ISO 9001 인증 제조업체들을 중심으로-)

  • 장형걸;김광수
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.1
    • /
    • pp.229-249
    • /
    • 2004
  • Quality management has been recognized as an important means to secure business competitiveness for management environment changes and competitiveness reinforcement. An effort of an ISO 9001 certification has thought that it is the best way to practice quality management. This paper checks a quality management situation of manufacturing companies that acquired ISO 9001 certification. Then, this paper investigates whether quality management is actual1y contributing to production performance and proposes proper alternatives for an improvement of production performance.

Pump performance analysis of Axial Flow Blood Pump using CFD (CFD를 활용한 축류형 혈액펌프의 펌프 특성 해석)

  • 최승한;김동욱
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.288-290
    • /
    • 2003
  • Artificial heart is divided by pulsation flow type and continuous flow type according to blood circulation pattern. Axial flow blood pump is a kind of continuous flow type artificial heart. Axial flow blood pump would be different pump performance according to impeller's shape and rotating velocity. Pump performance be able to compare by flow rate according to differential pressure and Impeller's rotating velocity. It confirms Impeller model of better efficiency according to compare Pump performance of axial flow blood pump using CFD with actual experiment result.

  • PDF