• Title/Summary/Keyword: Activity monitoring system

Search Result 380, Processing Time 0.025 seconds

A Wireless ECG monitoring System for Application in Life Emergency Event Detection and Analysis (긴급환자 상황인식 및 분석을 위한 무선 ECG모니터링 시스템)

  • Bhardwaj Sachin;Lee Dae-Seok;Chung Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.421-425
    • /
    • 2006
  • An ubiquitous healthcare system for the home care of elderly persons was designed and implemented using wireless sensor network technology. The wireless technology for home-care purpose gives new possibilities for monitoring of vital parameter with wearable biomedical sensors, and will give the patient the freedom to be mobile and still be under continuously monitoring and thereby to better quality of patient care. Emphasis is placed on recent advances in wireless ECG system for cardiac event monitoring with particular attention to arrhythmia detection in patient. This paper presents a diagnostic system for cardiac arrhythmias from ECG data, using wireless sensor technology. The system also provides an application for recording activities, events and potentially important medical symptoms. The hardware allows data to be transmitted wirelessly from on-body sensor to the base station and then to PC/PDA. Data is also transmitted to a back-end server for analysis using wireless internet connection. Experiments were conducted using the system for activity monitoring, exercise monitoring and medical screening tests and present preliminary data and results.

  • PDF

Vital Signal Monitoring Simulation System by Various Visual Stimulus (다양한 시각자극에 따른 생체신호 모니터링 시뮬레이션 시스템)

  • Chung, Kyung-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • With the development of next IT convergence technology and the construction of infrastructure for personalized services, the importance of services based on user's sensibility status and vital signal is being spotlighted. It is the most crucial factor for the strategy of sensibility engineering to investigate student's vital signal according to the sensibility. In this paper, we proposed the vital signal monitoring simulation system by the various visual stimulus. The proposed method obtained the student's vital signal by the various visual stimulus. And the power spectrum analysis using the fast fourier transform is evaluated the activity level between the sympathetic and the parasympathetic. The analyzed result is monitoring the sensibility by displaying the heath signal light. To evaluate the sensibility between the high school's students and the university's students, we conducted SD profile and paired T-tests so as to verify usefulness. This evaluation found that the difference of sensibility activity by positive and negative stimulus was statistically meaningful. Ultimately, this paper suggests empirical application to verify the adequacy and the validity.

A Cell-Based Assay System for Monitoring NF-$\kappa$B Activity in Human Epidermal Keratinocytes: A Screening Tool of the Antioxidants and Anti-inflammatories for Dermatological Purpose

  • Moon, Ki-Young;Hahn, Bum-Soo;Lee, Jinseon;Kim, Yeong-Shik
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.27 no.1
    • /
    • pp.17-27
    • /
    • 2001
  • A cell-based assay system for monitoring NF-$textsc{k}$B activity was developed to determine the influence of activated NF-$textsc{k}$B in human HaCaT cells. The pNF-$textsc{k}$B-SEAP-NPT plasmid that permits expression of the secreted alkaline phosphatase (SEAP) reported gene in response to the NF-$textsc{k}$B activity and contains neomycin phosphotransferase (NPT) gene for the geneticin resistance in host cells was constructed and transfected into human keratinocyte cell line HaCaT. Human HaCaT transfectant cells secreted the SEAP enzyme into the culture medium in a time-dependent manner until 72h. NF-$textsc{k}$B activities were measured in the SEAP reporter gene assay using a fluorescent detection method. The treatment of HaCaT cell transfectants with known antioxidants [e.g., N-acetyl-L-cysteine and vitamin C] showed inhibition of NF-$textsc{k}$B activity in a time-and concentration-dependent manner. The phorbol 12-myristate 13-acetate (PMA) known as a stimulator of NF-$textsc{k}$B expression demonstrated that it increased NF-$textsc{k}$B activity in a time- and concentration-dependent manner. This assay system could be used to determine the quantitative measurement of NF-$textsc{k}$B activity in the human skin and allow the screening of anti-inflammatory agents from various synthetic chemicals and natural products for dermatological purpose. Abbrevitions used: NF-$textsc{k}$B, nuclear factor kappa B; I-$textsc{k}$B, Inhibitory kappa B; SEAP, secreted alkaline phosphatase; NPT, neomycin phosphotransferease; PCR, polymerase chain reaction: dNTP, deoxynucleoside triphosphates; DMEM, dulbecco’s modified eagle medium; FBS, fetal bovine serum; PBs, phosphate-buffered saline; MUP, 4-methylumbellifery phosphate; NAC, N-acetyl-L-cysteine; DMSO, dimethyl sulfoxide; PMA, phorbol 12-myristate 13-acetate.

  • PDF

HRV Evaluation under Stress Condition by Using Patch Type Bipolar Heart Activity Monitoring System (패치형 바이폴라 심장활동 모니터링 시스템을 이용한 스트레스 상태의 HRV 평가)

  • Yang, Heui-Kyung;Lee, Jeong-Whan;Lee, Young-Jae;Kim, Kyeong-Seop;Lee, Kang-Hwi;Choi, Hee-Jung
    • Science of Emotion and Sensibility
    • /
    • v.12 no.2
    • /
    • pp.161-168
    • /
    • 2009
  • In this study, we have developed the patch type HAMS (Heart Activity Monitoring System) which is non-restricted, non-awarable and non-invasive. The module using wireless telecommunication to receive the ECG (electrocardiogram) signal at the computer has mobility which it easily monitors the heart activity of subjects in no time for long term at any time and places. We developed the small patch type electrode which can be attached on the chest. Also the reliability and moving artifact of ECG signal measured by this electrode have been verified. Using HAMS, we measured the HRV (Heart Rate Variability) parameters, the questionnaire evaluation for anxiety and stress and the amount of stress hormone (cotisol) to evaluate the stress effect in HRV on the same subject. As a result of comparing the values under non stressed and stressed condition, there was significant difference on many parameters. And the parameter highly related with stress on Pearson's Correlation Coefficient has been examined. These show that using HAMS is able to evaluate the function of autonomic nervous system. Therefore, we can predict heart problem in daily life by using HAMS. Also we expect that this module can be applied for more application as health monitoring system.

  • PDF

Minimum detectable activity of plastic scintillator for in-situ beta measurement system in ground water

  • Choi, Woo Nyun;Lee, UkJae;Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1169-1175
    • /
    • 2019
  • The minimum detectable activity (MDA) value was derived according to the flow rate of the sample and degree of amplification of the device by sending the sample directly from the collection site to the detection part through a pump. This method can lead to reduction in time and cost compared to the existing measurement method that uses a pre-treatment process. In this study, experiments were conducted on $^3H$ and $^{90}Sr$, which are the major pure beta-emitting radionuclides, by setting the sample flow rate and the amplification gain as factors. The MDA values were derived according to the flow rates, considering that the flow rate can affect the MDA values. There were no change in the MDA under different flow rates of 0, 600, 800, and 1000 mL/min. Therefore, it was confirmed that the flow rate may not be considered when collecting samples for monitoring in actual field. As the degree of amplification of the amplifier increased, the time required to reach the target MDA decreased. When the amplification was quadrupled, the detection efficiency increased by approximately 23.4 times, and the time to reach the MDA decreased to approximately 1/550 times. This method offers the advantage of real-time on-site monitoring.

User Activity Estimation by Non-intrusively Measurement (무구속적인 측정에 의한 사용자 활동 상태 추정 기법)

  • Baek, Jong-Hun;Yun, Byoung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.5
    • /
    • pp.101-110
    • /
    • 2009
  • The unconscious and non-intrusive measurements of activity signals or physiological signals represent important enabling technologies for realizing a ubiquitous healthcare environment as well as a related UI. Particularly, non-intrusive measurements should be used in activity monitoring system for long-term monitoring. This paper is based on activity estimation by measuring the activity signals of a user using a handhold device with an accelerometer. The user activity estimation system (UAES) presented in this paper makes non-intrusive measurements of activity signals to minimize inconveniencing a user and to create a more practical implementation in real life. Thus, a variety of positions in which the handhold device can be carried by a user for daily use is considered, such as in the front/hip/shirt pockets, a backpack, on the waist, and in the hand.

Design of Bowing-Activity Monitoring and Automatic Detection System Using 3-Axis Accelerometer (3축-가속도 센서를 이용한 배례(拜禮)동작 모니터링 및 자동검출 시스템 설계)

  • Lee, Young-Jae;Lee, Pil-Jae;Cha, Ji-Young;Sunoo, Sub;Hwang, Jin-Sang;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1150-1158
    • /
    • 2010
  • In this paper, a new reliable portable activity monitoring device implemented with the buddhist-style bowing activity and walking step detection algorithm, is presented. In order to monitor the bowing and walking activities, miniaturized 3-axis accelerometer sensor with the sensitivity of 800 mV/g was used. After initial signal conditioning, vector magnitude of accelerometer signals was calculated. Syntactic peak detection method was used in order to feature points. All signal processing algorithms were implemented in ultra-low power microcontroller MSP430 with double precision floating point arithmetic. For evaluation, 19 young man($24.22\pm5.22$ yrs) and woman($22.28\pm2.72$ yrs) were involved. The accuracy of the proposed algorithms were 98.91 %($\pm0.011$) for walking step detection and 98.25 %($\pm0.023$) for buddhist-style bowing activity. Comparing to the commercialized pedometer accuracy, 87.1 %($\pm0.058$), the proposed walking step detection algorithms show more reliable accuracy.

Dense RGB-D Map-Based Human Tracking and Activity Recognition using Skin Joints Features and Self-Organizing Map

  • Farooq, Adnan;Jalal, Ahmad;Kamal, Shaharyar
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.5
    • /
    • pp.1856-1869
    • /
    • 2015
  • This paper addresses the issues of 3D human activity detection, tracking and recognition from RGB-D video sequences using a feature structured framework. During human tracking and activity recognition, initially, dense depth images are captured using depth camera. In order to track human silhouettes, we considered spatial/temporal continuity, constraints of human motion information and compute centroids of each activity based on chain coding mechanism and centroids point extraction. In body skin joints features, we estimate human body skin color to identify human body parts (i.e., head, hands, and feet) likely to extract joint points information. These joints points are further processed as feature extraction process including distance position features and centroid distance features. Lastly, self-organized maps are used to recognize different activities. Experimental results demonstrate that the proposed method is reliable and efficient in recognizing human poses at different realistic scenes. The proposed system should be applicable to different consumer application systems such as healthcare system, video surveillance system and indoor monitoring systems which track and recognize different activities of multiple users.

Design and Development of Agriculture Drone battery usage Monitoring System using Wireless sensor network

  • Lee, Sang-Hyun;Yang, Seung-Hak;You, Yong-Min
    • International journal of advanced smart convergence
    • /
    • v.6 no.3
    • /
    • pp.38-44
    • /
    • 2017
  • Currently, wired gables have been installed or portable storage devices have been installed for data acquisition of flying drone. In this paper, we propose a technology to transmit data wirelessly by sensing information such as battery discharge value, acceleration, and temperature by attaching RF sensor to a drone. The purpose of this paper is to design and develop the monitoring technology of agriculture drone battery usage in real time using RF sensor. In this paper, we propose a monitoring system that can check real time data of battery changed value, temperature, and acceleration during pesticide control activity of agricultural drone.

Practical Application of AMSAA Model in the Product Development Process (제품개발 과정에서 AMSAA 모델의 실용적 활용방법)

  • Jung, Won;Kim, Jun-Hong
    • IE interfaces
    • /
    • v.19 no.1
    • /
    • pp.19-25
    • /
    • 2006
  • In the development process, the objective of a reliability growth program is to track the increase in system reliability, and determine as early as possible whether or not the system reliability is growing at a sufficient rate to meet the required goal and allocate available resources accordingly. Implementation of this kind of program will provide very useful information on concept selection, product/process reliability, and cost effectiveness without too much time, money and engineering effort being spent on the development of failure suspect parts. The purpose of this research is to present a practical method for efficiently monitoring a reliability growth test process using AMSAA(Army Materiel Systems Analysis Activity) reliability growth model. The presented growth management is a viable method for identifying failure modes, incorporating design changes and monitoring reliability progress on an on-going basis during the early stages of a product development program.