• Title/Summary/Keyword: Activity monitoring

Search Result 939, Processing Time 0.032 seconds

Zigbee based 1-ch ECG device with activity monitoring function (지그비를 기반으로 한 운동감시 기능을 가진 1채널 ECG장치 개발)

  • Hong, Joo-Hyun;Kim, Nam-Jin;Cha, Eun-Jong;Lee, Tae-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.41-43
    • /
    • 2005
  • PDA-based monitoring is used to acquire continuously the patient's vital signs, including electrocardiography, activity, heart rate and $SpO_2$. In this paper, A biomedical signal acquisition device was designed using 3-axial MEMS accelerometer and 1-ch ECG amplifier, to have the function of monitoring activity and electrocardiography. The proposed system is composed of transmitter and receiver. Through the Zigbee communication, subject's biosignals can be transmitted in real-time to receiver, and transmitted data confirmed using PDA. The packet size used in this device was set not to exceed a maximum payload size of 116 byte. One packet consists of two segments. The transmission speed was 21 packet per second, 420 ECG samples per second, and 42 acceleration samples per second. The proposed method can be used to develop Activities of Daily Living(ADL} monitoring devices for the elderly or movement impaired people and enables patients to be monitored without any constraints. Also, this method will reduce medical costs in the aged society.

  • PDF

Development of CMOS Image Monitoring System for Measurement of Biosensor Activity using Genetic Algorithm (유전자 알고리즘을 이용한 바이오센서 활동량 측정 CMOS 이미지 센서 모니터링 시스템 개발)

  • Park, Se-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.5
    • /
    • pp.930-936
    • /
    • 2008
  • CMOS image monitoring system for optimal measuring the activity of biosensor is developed using genetic algorithm. Most of living organism in water as water flea, fish, etc are frequently used as biological sensor for monitoring the water quality. It is very difficult to measure the activity of biosensor by image sensor because the value of measurement is varied with gathering method of biosensor images. The suggested monitoring system can optimally measures the activity of biosensor by genetic algorithm. The system is implemented with FPGA into the small hardware which is excellent in terms of the price and performance.

Study of the Effects of Supplier Monitoring on Shop floor Productivity (공급사 모니터링이 현장생산성에 미치는 영향에 관한 연구)

  • Cho, BooYun;Kang, Gi-Choon;Hyun, MinCheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7025-7039
    • /
    • 2014
  • Focal companies (hereafter called buyers) adopt outsourcing practices from a supply chain management strategy to be competitive. Buyers face the bridge transfer after outsourcing contracts, and the monitoring practices would be the only control mechanism left to prevent losing control over the suppliers. This study suggests the set of monitoring practices (i.e., capability, activity and outcome monitoring) as the independent variables to enhance the buyer-supplier collaboration and supplier's performance. In addition the buyer's efforts of monitoring are assumed to influence the buyer's shop floor productivity mediated by the supplier's performance and buyer-supplier collaboration. The results showed that the monitoring practices are meaningful antecedents to the supplier's performance and buyer-supplier collaboration, which fully mediates between the monitoring practices and buyer's shop floor productivity. The mediating role of the buyer-supplier collaboration between activity monitoring and shop floor productive has been rejected, because the negative effect of activity monitoring on buyer-supplier collaboration conflicts with the positive impact of buyer-supplier collaboration on shop floor productive. The theoretical contribution and managerial implications with limitations have been discussed.

Design of a Portable Activity Monitoring System (휴대용 활동 상태 모니터링 시스템의 설계)

  • Lee, Seung-Hyung;Park, Ho-Dong;Yoon, Hyung-Ro;Lee, Kyung-Joung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.1
    • /
    • pp.32-38
    • /
    • 2002
  • This paper describes a development of a portable physical activity monitoring system using two accelerometers to quantify physical activity. The system hardware consists of two piezoresistive accelerometers, amplifiers with gain of 30, lowpass filters with cut-off frequency of 15Hz, offset control circuits, one-chip microcontroller and flash memory card. In order to evaluate the performance of the system we acquired 3 channel data at 32 sample/sec from body-fixed accelerometers in chest and right upper leg. And then the acquired data were processed by MatLab on personal computer. We tried to distinguish not only fundamental actions which are steady-state activities such as standing, sitting, and lying but also dynamic activities with walking, up a stairway, down a stairway, and running. Five subjects participated the evaluation process which compare the video data with the measured data. As a result, the activity classification rate of 90.6% on average was obtained. Overall results showed that the steady-state activities could be classified from the low component of 3-axis acceleration signal and dynamic activities could be distinguished from frequency analysis using wavelet transform and FFT. Finally, we could find that this system can be applied to acquire and analyze the static and dynamic physical activity data.

Business Activity Monitoring Using Process-based Event Analysis (프로세스 기반 이벤트 분석을 이용한 비즈니스 활동 모니터링)

  • Son, Sung-Ho;Jung, Jae-Yoon;Kang, Suk-Ho;Cho, Nam-Wook
    • The Journal of Society for e-Business Studies
    • /
    • v.12 no.2
    • /
    • pp.219-231
    • /
    • 2007
  • Based on a complex event processing technique, an event analysis method for Business Activity Monitoring(BAM) is developed to provide an early warning for on-going events so that process managers effectively detect and monitor potential risks prior to the completion of the events. In this study, process-based event monitoring procedures to extract events with significant risks are presented; Complex event patterns are defined from historical event log data and risks of events are evaluated based on the patterns. A process-based event monitoring architecture for BAM is also presented. The proposed method has been applied to a service process of a home shopping company.

  • PDF

Implementation of Real-time Measurement Hardware for Activity of Water Flea and Remote Monitoring System using CCD Camera (CCD 카메라를 사용한 물벼룩의 실시간 활동량 측정 하드웨어와 원격 모니터링 시스템 구현)

  • Park, Se-Huyn;Park, Se-Hoon;Kim, Eung-Soo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.5
    • /
    • pp.30-37
    • /
    • 2007
  • Hardware for monitoring the water quality is developed using water fleas. Water flea is a frequently used biological sensor for monitoring the water quality. Water fleas quickly respond to the incoming toxic water by changing their activity when they are exposed. By measuring the activity of water fleas, the incoming toxic water is instantly detected in real time. So far the measurement of activity of water fleas has been done with a system equipped with a light source of LED and a light detector of photo transistor. Water flea itself is, however, sensitive to light resulting in incorrect response and the system has two inconvenient separate parts of the light source and the detector. This paper suggests a system using a CCD camera instead of a light source and a detector. The suggested system processes the image data from the CCD camera in real time without any delay. The developed system becomes a part of the remote water monitoring embedded system.

Information Activity Monitoring for Enhancing the Utilization of the Enterprise Information System (기업 정보 시스템의 활용도 향상을 위한 정보활동 모니터링)

  • Han, Kwan-Hee;Song, Hee-Seok
    • The KIPS Transactions:PartD
    • /
    • v.13D no.5 s.108
    • /
    • pp.749-754
    • /
    • 2006
  • Recently, many enterprises are introducing information systems for their competitive advantages. For enhancing the utilization level of enterprise information system, it is quite important to monitor the usage states of the information systems continuously. However, most enterprise information systems lack this functionality. Proposed in this paper is the framework of IAM (Information Activity Monitoring), which is defined as real-time reporting and alerting of significant information-related activities. This IAM framework provides 4 different views about the information system (data, IT system, business process, and participant) and is implemented as a part of integrated design/manufacturing information system developed by aerospace parts manufacturer. By using the IAM function, IT personnel can monitor significant information-related activities systematically and feedback to their users timely, and ultimately enhance the utilization level of information system.

Optimal Monitoring Intervals and MDA Requirements for Routine Individual Monitoring of Occupational Intakes Based on the ICRP OIR

  • Ha, Wi-Ho;Kwon, Tae-Eun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Background: The International Commission on Radiological Protection (ICRP) has recently published report series on the occupational intakes of radionuclides (OIR) for internal dosimetry of radiation workers. In this study, the optimized monitoring program including the monitoring interval and the minimum detectable activity (MDA) of major radionuclides was suggested to perform the routine individual monitoring of internal exposure based on the ICRP OIR. Materials and Methods: The derived recording levels and the critical monitoring quantities were reviewed from international standards or guidelines by the International Atomic Energy Agency (IAEA), the International Organization for Standardization (ISO), and the European Radiation Dosimetry Group (EURADOS). The OIR data viewer provided by ICRP was used to evaluate the monitoring intervals and the MDA, which are derived from the reference bioassay functions and the dose coefficients. Results and Discussion: The optimal monitoring intervals were determined taking account of two requirement conditions on the potential intake underestimation and the MDA values. The MDA requirement values of the selected radionuclides were calculated based on the committed effective dose from 0.1 mSv to 5 mSv. The optimized routine individual monitoring program was suggested including the optimal monitoring intervals and the MDA requirements. The optimal MDA values were evaluated based on the committed effective dose of 0.1 mSv. However, the MDA can be adjusted considering the practical operation of the routine individual monitoring program in the nuclear facilities. Conclusion: The monitoring intervals and the MDA as crucial factors for the routine monitoring were described to suggest the optimized routine individual monitoring program of the occupational intakes. Further study on the alpha/beta-emitting radionuclides as well as short lived gamma-emitting nuclides will be necessary in the future.

Development of the Activity Posture Classifier for Ubiquitous Health Care (유비쿼터스 헬스케어를 위한 활동상태 분류기 개발)

  • Kim, Se-Jin;Chung, Wan-Young;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.703-706
    • /
    • 2007
  • The real-time monitoring about the activity of the human provides useful information about the activity quantity and an ability. This study developed a system for human physical activity assessment in ambulatory monitoring using portable sensing device combining a tri-axial accelerometer and wireless sensor node. This real-time system is able to identify several postures, posture transitions and movements with classification algorithm. In addition, this system also features fall detection capability. The results of the assessment for evaluating the performance of the system show high identification accuracy.

  • PDF

Tritium( $^3$H) Activity Measurement by the Liquid Scintillation Counting Method

  • Hwang, Sun-Tae;Oh, Pil-Jae;Lee, Min-Kie;Kim, Wi-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.E
    • /
    • pp.299-302
    • /
    • 1994
  • At a nuclear power plant, environmental radioactivity monitoring is routine work for the radiation safety management For the environmental monitoring of tritium($^3$H) activity in water sampled liquid scintillation counting( LSC) method is applied to measure low- energy beta activity from tritium in the samples. The $^3$H activity is measured using the BECKMAN 5801 system at the KRISS( Korea Research Institute of Standards and Science) for evaluating the lower limits of detection( LLD) of $^3$H measurement and the measuring capability of low-level $^3$H activity at four nuclear Power Plant sites. The LSC systems used for low-level $^3$H activity measurements at the nuclear Power Plants are confirmed to satisfy throughout an intercomparison study under the experimental arrangements by the KRISS.

  • PDF