• 제목/요약/키워드: Active-Bypass

검색결과 31건 처리시간 0.029초

By-pass Dust를 첨가한 혼합 시멘트의 수화 및 기계적 특성 (Hydration and mechanical properties of Blended Cement added Bypass dust)

  • 성진욱;나종윤;김창은;이승헌;이봉한;김수룡;류한웅
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.33-39
    • /
    • 1999
  • This study was conducted to confirm the effect of bypass dust on the hydration and mechanical properties of the cement pastes and mortar obtained from ordinary Portland cement (OPC), OPC-slag and OPC-fly ash system. The rate of heat evolution is accelerated with the content of By-pass Dust(BD). total heat evolution increased because alkali-chlorides activated the hydration of blended cement. Compressive strength and bound water content show maximum value at 5wt% By-pass Dust(BD) on each curing time in ordinary Portland cement and slag blended cement. Ca(OH)2 content of Ordinary Portland Cement increased as the content of BD and curing time. In blended cement, the formation of Ca(OH)2 is active at early hydration stage. By pozzolanic reaction, the content of Ca(OH)2 is decreased as curing time goes by. According to the BD content stable chlorides complex of Friedel's salt (C3A·CaCl2·10H2O) is created. Due to the hydration activation effect of chlorides and alkali we observed Type II C-S-H, which developed into densest microstructure.

  • PDF

Application of a C-Type Filter Based LCFL Output Filter to Shunt Active Power Filters

  • Liu, Cong;Dai, Ke;Duan, Kewei;Kang, Yong
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.1058-1069
    • /
    • 2013
  • This paper proposes and designs a new output filter called an LCFL filter for application to three phase three wire shunt active power filters (SAPF). This LCFL filter is derived from a traditional LCL filter by replacing its capacitor with a C-type filter, and then constructing an L-C-type Filter-L (LCFL) topology. The LCFL filter can provide better switching ripple attenuation capability than traditional passive damped LCL filters. The LC branch series resonant frequency of the LCFL filter is set at the switching frequency, which can bypass most of the switching harmonic current generated by a SAPF converter. As a result, the power losses in the damping resistor of the LCFL filter can be reduced when compared to traditional passive damped LCL filters. The principle and parameter design of the LCFL filter are presented in this paper, as well as a comparison to traditional passive damped LCL filters. Simulation and experimental results are presented to validate the theoretical analyses and effectiveness of the LCFL filter.

Determinants of the Volumetric Markers of Left Atrial Contraction Function in Coronary Artery Disease: A Cross-sectional Study

  • Taimoor Etemad;Ali Hosseinsabet;Negar Omidi;Reza Mohseni-Badalabadi
    • Journal of Cardiovascular Imaging
    • /
    • 제30권1호
    • /
    • pp.37-46
    • /
    • 2022
  • BACKGROUND: A body of research advocates the prognostic role and usefulness of the volumetric markers of left atrial (LA) phasic functions in the diagnosis of LA dysfunction. We aimed to determine the independent determinants of the volumetric markers of LA contraction function in candidates for coronary artery bypass graft (CABG) surgery. METHODS: This cross-sectional study enrolled 516 candidates for CABG. The biplane maximal, minimal, and pre-P volumes of the LA were measured with two-dimensional echocardiography, and LA active emptying fraction was calculated. The standardized correlation coefficient for the correlation between each factor and LA active emptying fraction was calculated by using univariate and backward multivariable regression analyses. RESULTS: The multivariable regression analysis demonstrated that the heart rate (β = 0.15; p = 0.001), S (β = 0.09; p = 0.036), E/e' ratio (β = -0.11; p = 0.014), left ventricle (LV) ejection fraction (β = 0.15; p = 0.001), and LA enlargement (β = -0.19; p < 0.001) were the independent determinants of LA active emptying fraction. CONCLUSIONS: The independent determinants of LA contraction function were the heart rate, S, LV ejection fraction, LA enlargement, and E/e' ratio in candidates for CABG surgery.

하이브리드 웹 기반의 스마트 발권 시스템 (A Smart Ticketing System Based-on Hybrid Web)

  • 박병언;박진섭;정일홍
    • 디지털콘텐츠학회 논문지
    • /
    • 제12권4호
    • /
    • pp.567-574
    • /
    • 2011
  • 본 논문에서는 공연장이나 야구장 등 다양한 분야에서 티켓을 발권하는데 있어서 필요한 보안성과 호환성 그리고 상업성까지 기존 문제를 해결한 미래형 웹 시스템을 설계하고 구현하였다. 보안 문제로 이슈가 되고 있는 우회 해킹 기법인 스크린 해킹을 방어하고 더 강력한 보안을 위해 모바일을 이용한 OTP(One Time Password)시스템을 제시하고 호환 문제를 해결하기 위해 ActiveX를 사용하지 않는 Non-ActiveX System과 다양한 환경이나 기기에서 이용이 가능하게 기존 반응형 하이브리드 웹을 개선한 스마트 발권 시스템을 제시한다. 또한 모바일 기기의 특징을 이용한 지능형 화면 전환 시스템과 자동 할인 시스템, 최단거리 공연장 안내 시스템으로 상업적인 부분까지 고려하여 완성도 높은 시스템을 제시하였다.

네트워크 침입자탐지기법 분석과 대응 (Analysis & defence of detection technology in network Attacker)

  • 윤동식
    • 융합보안논문지
    • /
    • 제13권2호
    • /
    • pp.155-163
    • /
    • 2013
  • Connection hijacking은 TCP 스트림을 자신의 머신을 거치게 리다이렉션 할 수 있는 TCP 프로토콜의 취약성을 이용한 적극적 공격 (Active Attack)이다. 리다이렉션을 통해 침입자는 SKEY와 같은 일회용 패스워드나 Kerberos와 같은 티켓 기반 인증 시스템에 의해 제공되는 보호 메커니즘을 우회할 수 있다. TCP 접속은 누군가 접속로 상에 TCP 패킷 스니퍼나 패킷 생성기를 가지고 있다면 대단히 취약하다. 스니퍼의 공격으로부터 방어하기 위하여 일회용 패스워드나 토큰 기반 인증과 같은 사용자 식별 스킴이 사용되어지고 있다. 이들은 안전하지 않은 네트워크상에서 스니핑으로부터 패스워드를 보호하지만 이러한 방법들은 데이터 스트림을 암호화하거나 사인하지 않는 한 적극적인 공격으로부터 여전히 취약하다. 많은 사람들이 적극적 공격은 대단히 어렵고 그만큼 위협도 적을 것이라고 생각하고 있지만 여기서는 이러한 환상을 깰 수 있도록 유닉스 호스트에 성공적으로 침입한 대단히 적극적 공격을 제시한다. 최근 이론적으로 알려진 이 취약점을 공격할 수 있는 도구가 인터넷 상에 공개되어 이에 대한 대책이 요구되고 있다. 본 논문에서는 무선네트워크 상에서 침입자탐지 분석기법에 대하여 제안한다.

Single-phase Uninterruptible Power Supply employing Superconducting Magnet Energy Storage Unit

  • Kang, Feel-Soon
    • Journal of information and communication convergence engineering
    • /
    • 제5권4호
    • /
    • pp.362-368
    • /
    • 2007
  • A single-phase uninterruptible power supply system equipped with a superconducting magnet energy storage unit is proposed to achieve a simple circuit configuration and higher system reliability. It reduces a number of switching devices by applying a common-arm scheme. Removing some switches or substituting passive elements for active switches can increase the sophistication and reduces degree of freedom in control strategy. However, high-performance DSP controller can execute the complicated control task with no additional cost. Operational principles to normal, stored-energy, and bypass mode are discussed in detail. The validity of the proposed system is verified by experimental results.

CBS-Dust의 화학성분 및 미세구조 특성 분석 (Analysis of Chemical Components and Microstructure Characteristics of CBS Dust)

  • 한준희;이영준;현승용;이동주;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.180-181
    • /
    • 2019
  • In this study, in order to find new uses for CBS dust, the chemical components of CBS dust were analyzed and effectively proposed a method. Chemical analysis shows that CBS dust contains a large amount of alkali in addition to chloride therefore, if CBS dust is used for secondary concrete products that use high amounts of mixed materials without rebars, it will be found that it can be used effectively for enhancing strength by active alkali.

  • PDF

경유차 매연저감장치에 의해 비활성화된 DOC촉매의 재제조 효과에 관한 연구 (A Study on the Effectiveness of Remanufacturing Technology for the Diesel Oxidation Catalyst(DOC) Deactivated by Diesel Exhaust Gas)

  • 박해경
    • 청정기술
    • /
    • 제16권4호
    • /
    • pp.265-271
    • /
    • 2010
  • 경유차 매연저감장치에서 비활성화된 디젤산화촉매(DOC)를 대상으로 여러 가지 조건에서 재제조한 후, 재제조된 DOC의 일산화탄소(CO)와 탄화수소화합물(THC)의 저감효율과 촉매물성 특성을 분석하여 비활성화된 DOC 촉매에 대한 재제조 효과를 관찰하였다. 재제조된 DOC촉매에 대한 오염물질 저감성능 평가는 디젤엔진 다이나모 장치를 이용, 배기가스를 일부 우회시켜 온도와 공간속도조절이 가능한 촉매반응장치로 수행하였으며, 촉매물성 분석은 광학현미경, EDX, ICP, TGA 그리고 porosimeter를 이용하였다. 연구수행 결과 비활성화된 DOC 촉매를 본 연구에서 적용된 고온배소세정, 산성/염기성용액에 의한 초음파세정, 세정 후 촉매활성성분 재함침에 의한 재제조를 수행할 경우, 재제조된 DOC 촉매의 성능이 신품 성능의 90% 이상으로 회복되는 것을 확인하였으며, 광학현미경, EDX, TGA와 ICP등의 분석을 통해 본 연구조건에서의 재제조 과정으로, 촉매의 활성 저하 원인이 되었던 각종 불순 성분 대부분이 비활성화된 DOC 촉매로부터 제거되는 것을 확인하였다.

죽상동맥경화성 하지동맥폐쇄증에서 관상동맥조영술의 필요성 및 동반되는 관상동맥 질환의 양상 (The Necessity for Coronary Angiography in Atherosclerotic Arterial Obstruction in the Lower Extremities and the Clinical Features of Accompanied Coronary Arterial Diseases)

  • 이재욱;염욱;박영우;신화균;원용순
    • Journal of Chest Surgery
    • /
    • 제39권8호
    • /
    • pp.619-625
    • /
    • 2006
  • 배경: 죽상동맥경화성 하지동맥폐쇄증은 대부분의 경우에 전신 동맥 경화증이 동반되며 사망의 원인으로는 주로 반 이상이 관상동맥질환에 의하여 발생한다. 또한 만성 동맥폐쇄증 수술 후 수술 사망 원인은 심장 합병증에 의한 사망이 가장 빈번한 것으로 알려져 있다. 특히 죽상동맥경화성 하지동맥폐쇄증 환자에게 과거에 심질환이 없거나 허혈성 심질환의 주증상이 없던 경우에 수술 후 높은 사망률을 보이는데 이런 이유로 이 환자군에 대한 관상동맥질환의 동반 여부에 대한 수술 전 검사의 필요성이 제기되는 바이다. 대상 및 방법: 2001년 2월부터 2004년 10월까지 죽상동맥경화성 하지동맥폐쇄증으로 입원한 환자 중 과거력상 심질환이 있었거나 허혈성 심질환이 주증상이었던 환자를 제외한 52명의 환자를 대상으로 관상동맥조영술과 하지동맥조영술을 동시에 시행하여 죽상동맥경화성 하지동맥폐쇄증에서 관상동맥질환의 동반 빈도를 파악하였다. 또한 죽상동맥경화성 하지동맥폐쇄증의 중증도를 나타내는 AVO score와 동반된 관상동맥질환과의 상관관계를 비교하였다. 결과: 죽상동맥경화성 하지동맥폐쇄증에서 관상동맥질환을 동반한 경우는 63%(33명)였고, 고령, 당뇨, 고혈압, 흡연력, 고콜레스테롤혈증 등의 동맥 경화증의 위험인자 중 고령과 고혈압이 관상동맥 질환을 동반하는 죽상동맥경화성 하지동맥폐쇄증의 중증도와 통계학적인 의미를 보였다. AVO score가 높을수록 관상동맥 질환의 동반이 흔하였고 관상동맥질환의 중증도 역시 증가되는 소견을 보였다. 관상동맥질환이 동반된 죽상동맥경화성 하지동맥폐쇄증 환자에서 관상동맥 우회술 및 관상동맥 중재적 시술을 병합하여 하지동맥 우회술을 시행한 경우, 하지동맥 우회술의 단독시행에 비해 사망률이 현저히 감소하였다. 결론: 과거력상 심질환이 없거나 허혈성 심질환의 주증상이 없는 죽상동맥경화성 하지동맥폐쇄증 환자에서 특히, 고령, 고혈압, AVO score가 높은 환자군에서는 수술 전 관상동맥조영술을 시행하여 동반되는 관상동맥 질환을 파악한 뒤 이에 대한 적극적인 치료를 시행하여야 한다.

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.