• Title/Summary/Keyword: Active system

Search Result 7,705, Processing Time 0.034 seconds

A Study on the Back Pressure Characteristics and Engine Performance of Muffler with Exhaust Variable Valve (배기 가변 밸브를 적용한 소음기의 배압특성 및 엔진 성능에 관한 연구)

  • Park Kyoung-Suk;Park Se-Jong;Suh Ho-Chul;Son Sung-Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.7 s.184
    • /
    • pp.108-113
    • /
    • 2006
  • Recently, Automobile manufactures have developing automotive exhaust system under consideration for improvement in engine performance. It thus develop many exhaust components. For example active muffler, semi-active muffler, electronic muffler etc. In this components consider enhanced back pressure and reduction noise. Especially, In recent years it develop the study of semi-active muffler. Semi-active muffler is simple structure and excel performance. Recently many forms semi-active muffler was developed and adopted to the actual use in consideration of cost and technical side for noise and vibration. This study had main objects about the recently developed the semi-active muffler. It was to show its combustion performance as well as its enhanced back pressure characteristics in design. Therefore if the precise analysis of the combustion pressure according to the back pressure transmission was carried out, it was understood that this study would be utilized in the design of the exhaust system such as the semi-active muffler.

A New Control Scheme of the Line-Interactive UPS Using the Series Active Compensator (직렬 능동 보상기를 이용한 Line-Interactive UPS의 새로운 제어 기법)

  • Jang, Hoon;Lee, Woo-Cheol;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.8
    • /
    • pp.405-412
    • /
    • 2003
  • This paper presents a three-phase Line-Interactive uninterruptible power supply (UPS) system with series-parallel active power-line conditioning capabilities, using synchronous reference frame (SRF) based controller, which allows an effective power factor correction, source harmonic voltage compensation, load harmonic current suppression, and output voltage regulation. The three-phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low THD (total harmonic distortion). The control algorithm using SRF method and the active power flow through the Line-interactive UPS systems are described and studied. The simulation and experimental results are depicted in this paper to show the effect of the proposed algorithm.

Experiment of an ABS-type control strategy for semi-active friction isolation systems

  • Lu, Lyan-Ywan;Lin, Ging-Long;Lin, Chen-Yu
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.501-524
    • /
    • 2011
  • Recent studies have discovered that a conventional passive isolation system may suffer from an excessive isolator displacement when subjected to a near-fault earthquake that usually has a long-period velocity pulse waveform. Semi-active isolation using variable friction dampers (VFD), which requires a suitable control law, may provide a solution to this problem. To control the VFD in a semi-active isolation system more efficiently, this paper investigates experimentally the possible use of a control law whose control logic is similar to that of the anti-lock braking systems (ABS) widely used in the automobile industry. This ABS-type controller has the advantages of being simple and easily implemented, because it only requires the measurement of the isolation-layer velocity and does not require system modeling for gain design. Most importantly, it does not interfere with the isolation period, which usually decides the isolation efficiency. In order to verify its feasibility and effectiveness, the ABS-type controller was implemented on a variable-friction isolation system whose slip force is regulated by an embedded piezoelectric actuator, and a seismic simulation test was conducted for this isolation system. The experimental results demonstrate that, as compared to a passive isolation system with various levels of added damping, the semi-active isolation system using the ABS-type controller has the better overall performance when both the far-field and the near-fault earthquakes with different PGA levels are considered.

A Study on the Application of Semi-active Suspension System to a 3-D Full Vehicle Model (전차 모델에 대한 반능동 현가장치의 적용에 대한 연구)

  • 방범석;백윤수;박영필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.938-944
    • /
    • 1994
  • Active damping has been shown to offer increased suspension performance in terms of vehicle isolation, suspension packaging, and road-tire contract force. Many semi-active damping strategies have been introduced to approximate the response of active damping with the modulation of passive damping parameters. This study investigates the characteristics of semi-active suspension control through the simulation of passive, skyhook active, and semi-active damping models. A quarter car model is studied with the conrolled damping replacing both passive and active damping. A new semi-active scheme is suggested to eliminate the abrupt changes in semi-active damping force. It is shown that the new strategy performs almost identically to the so called "force controlled" semi-active law without steep changes in damping force or body acceleration.eleration.

  • PDF

A Parallel Operation System of the Z-Source Active Power Filter with Fuel Cells System (연료전지 Z-소스 능동전력필터의 병렬운전 시스템)

  • Oum, J.H.;Jung, Y.G.;Lim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.372-375
    • /
    • 2006
  • This paper proposes a parallel operation system of the Z-source active power filter using one fuel cells(FC) system. The proposed system is composed of two Z-source inverters operating in parallel only one PEM(Polymer Electrolyte Membrane)FC system. Also, as the control algorithm of the active power filter, a single phase P-Q theory and PI control are adopted. The effectiveness of the proposed the system is verified by the PSIM simulation in the steady state and the transient state.

  • PDF

A Study on a Stereoscopic Display System Using a Rotary Disk Type Beam Shutter (회전 디스크형 빔 셔터를 이용한 입체영상 디스플레이 시스템에 관한 연구)

  • Lee, Kwang-Hyung;Jang, Tae-Jeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.196-198
    • /
    • 2006
  • In this paper, a stereoscopic display system using a rotary disk tyre beam shutter and two beam projectors is proposed. It is a kind of active stereoscopic display and can be easily converted from passive stereoscopic system using polarizing filters. If it is possible to synchronize the revolution speed of the beam shutter with the integer multiple of the scanning frequency of the beam projectors, we can obtain a comparable performance with our system to an active stereoscopic system using one expensive high performance beam projector. Further, if we rotate the beam shutter at sufficiently high revolution speed, our active stereoscopic system works regardless of synchronization and thus the system is much easier to implement.

  • PDF

A Study on a Stereoscopic Display System Using a Rotary Disk Type Beam Shutter (회전 디스크형 빔 셔터를 이용한 입체영상 디스플레이 시스템에 관한 연구)

  • Lee, Kwang-Hyung;Jang, Tae-Jeong
    • 한국HCI학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.739-743
    • /
    • 2007
  • In this paper, a stereoscopic display system using a rotary disk type beam shutter and two beam projectors is proposed. It is a kind of active stereoscopic display and can be easily converted from passive stereoscopic system using polarizing filters. If it is possible to synchronize the revolution speed of the beam shutter with the integer multiple of the scanning frequency of the beam projectors, we can obtain a comparable performance with our system to an active stereoscopic system using one expensive high performance beam projector. Further, if we rotate the beam shutter at sufficiently high revolution speed, our active stereoscopic system works regardless of synchronization and thus the system is much easier to implement.

  • PDF

A Study on Deploying Time of Active Hood Lift System of Passenger Vehicles with Principal Design Parameters (중요 설계변수에 따른 승용차 능동후드리프트 시스템의 전개시간 연구)

  • Lee, Tae-Hoon;Yoon, Gun-Ha;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.1
    • /
    • pp.63-68
    • /
    • 2016
  • This research investigates the deployment time of an active hood lift system(AHLS) activated a gunpowder actuator for the passenger vehicle. The deployment time of the system is investigated by changing the principal design parameters of the system. In order to achieve this goal, after introducing the geometric structure and operating principle of the AHLS, the dynamic equations of the system are formulated for deploying motion. Subsequently, using the dynamic equations, the deployment time of the system is determined by changing several geometric design parameters such as location of actuator. It is then identified which design parameters are main factors to affect the deployment time of AHLS.

A Novel Photovoltaic Power Generation System including the Function of Shunt Active Filter

  • Park, Minwon;Seong, Nak-Gueon;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.2
    • /
    • pp.103-110
    • /
    • 2003
  • With significant development of power electronics technology, the proliferation of nonlinear loads such as static power converters has deteriorated power quality in power transmission and distribution systems. Notably, voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many countries. Many photovoltaic power generation systems installed in building systems have harmonics that are the worst object for distribution systems as a utility interactive system, and it tends to spread out continuously. Proposed and implemented in this paper is a multi-function inverter control strategy that allows a shunt active filter function to the power inverter of the photovoltaic power generation system established on a building system. The effectiveness of the proposed system is demonstrated through the simulation of a hypothetical power system using PSCAD/EMTDC.

RESPONSE CONTROL OF 3D IRREGULAR BUILDINGS UNDER SEISMIC EXCITATIONS USING TLCD (TLCD를 이용한 지진하중을 받는 3차원 비정형 건축구조물의 응답제어)

  • 김홍진;김형섭;안상경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.66-71
    • /
    • 2003
  • The semi-active TLCD system is investigated for control of responses of 3D irregular buildings under seismic excitations. The TLCD system is a special type of TMD system providing a performance similar to a TMD system but offers a number of practical advantages over the traditional TMD system. The equations of motion for the combined building and TLCD system are derived for multistory building structures with rigid floors and plan and elevation irregularities. Simulation results for control of two multistory moment-resisting space structures with vertical and plan irregularities show clearly that the semi-active TLCD control system reduces the responses of 3D irregular buildings subjected to earthquake ground motions efficiently.

  • PDF