• 제목/요약/키워드: Active input current control

검색결과 127건 처리시간 0.023초

LLCL 입력필터를 갖는 단상 그리드 컨버터의 가상 저항에 따른 전류제어 안정도 해석 (Stability Analysis of Current Control based on Virtual Resistor for Single-Phase Grid Converters with LLCL Input Filters)

  • 배철주;이동춘
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.404-410
    • /
    • 2016
  • To avoid the stability issues of LLCL filters, passive or active damping methods to eliminate the resonance phenomena are required. In this paper, system stability of a current control is analyzed when the active damping scheme based on the virtual resister is utilized in single-phase grid converter systems with LLCL input filters. The control performance according to the parameters of the virtual resistance is investigated. The validity of stability analysis was verified by simulation and experimental results.

A Versatile Universal Capacitor-Grounded Voltage-Mode Filter Using DVCCs

  • Chen, Hua-Pin;Shen, Sung-Shiou
    • ETRI Journal
    • /
    • 제29권4호
    • /
    • pp.470-476
    • /
    • 2007
  • In this paper, a versatile three-input five-output universal capacitor-grounded voltage-mode filter is proposed. The circuit employs two differential voltage current conveyors as active elements together with two grounded capacitors and four resistors as passive elements. The proposed configuration can be used as either a single-input five-output or three-input two-output. Unlike the previously reported works, it can simultaneously realize five different generic filtering signals: lowpass, bandpass, highpass, bandreject, and allpass. It still maintains the following advantages: (i) the employment of all grounded capacitors, (ii) no need to employ inverting-type input signals, (iii) no need to impose component choice, (iv) orthogonal control of the resonance angular frequency ${\omega}_o$ and the quality factor Q, and (v) low active and passive sensitivity performances.

  • PDF

단상 AC/DC PWM 변환기의 단위 역률 제어 (Unity Power Factor Control for A Single Phase AC/DC PWM Converter)

  • 강동우;차영길;이득기;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.373-377
    • /
    • 1996
  • Recently, active power factor control for AC/DC converter has been required to replace for a conventional diode rectifier. A voltage type AC/DC converter is widely used to obtain higher regulated DC voltage than input voltage with a unity power factor and a sinusoidal line current. This paper describes several active power factor control method for AC/DC converter. The analysis of several active power factor control is given. The simulations for hysteresis control, peak current control. constant frequency control and average current mode control are represented and compared.

  • PDF

전류형 능동 교류 전력필터 (Current - Fed Active AC Power Filter)

  • 박민호;최규하;이근하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.409-413
    • /
    • 1988
  • In this paper a control technique for active power filters is proposed which not only eliminates the harmonic current, but also controls the reactive power at the ac side of PWM inverter-induction motor drive system. Injecting the proposed PWM current enables the harmonic components of orders not greater than the pulse number per half-cycle to be removed completely. It also enables the input power factor to become unity. Theoretical investigations are performed to evaluate the performance of the proposed control technique.

  • PDF

새로운 PFC 스텝-업 컨버터의 입출력 파형해석 및 고조파분석에 관한 연구 (A Study on Input${\cdot}$Output Waveform Solutions and Harmonics Analyses for a Novel PFC Step-up Converter)

  • 곽동걸
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권12호
    • /
    • pp.622-628
    • /
    • 2005
  • This paper is given a full detail of mathematical analyses of input current and output voltage for a novel active type power factor correction (PFC) converter. These are compared with harmonics components of input current for a conventional PFC converter. The proposed PFC converter is constructed in using a new loss-less snubber circuit to achieve a soft switching of control device. Also the proposed converter for discontinuous conduction mode (DCM) eliminates the complicated circuit control requirement and reduces the size of components. The input current waveform in the proposed converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, input power factor is nearly unity and the control method is simple. Particularly, the stored energy of loss-less snubber capacitor is recovered with input side and increases input current from resonant operation. The result is that input power factor of the proposed converter is higher than that of conventional PFC converter. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.

2분할 전류유입 공진 회로를 이용한 PFC회로의 설계 (Design of the Circuit for a Power Factor Correction using the Two-Input Current Resonant)

  • 장우신;고강훈;서기영;이현우;곽동걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.233-235
    • /
    • 2001
  • On the active filter converter for power factor correction is used inverter for a air-conditioner's power supply to meet IEC standard In the active filter topology for power factor correction, extra switch only control the input current indirectly to satisfied with the IEC standard for reducing the cost and size. In this paper, by dividing the input current into two different modes, the current conduction period can be widened and harmonics can largely be canceled between the two modes. Hence, the harmonics characteristics can be significantly improved, whereby the lower order harmonics, such as the fifth and seventh orders, are much reduced. The results are confirmed by theoretical and experimental implementations.

  • PDF

응답 의존형 MR 감쇠기의 성능 평가 (Performance Evaluation of Response-Dependent MR Damper)

  • 이상현;민경원;윤경조
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.511-518
    • /
    • 2006
  • In this study, seismic response mitigation effect of an MR damper generating response-dependent frictional force is investigated. It has been reported in previous studies that passively operated MR damper with constant input current doesn't show better control performance than semi-active MR damper with varying input current calculated by control algorithms such as linear quadratic regulator and sliding mode control. However, in order to operate the MR damper semi-actively, other control systems besides the damper itself such as sensors for measuring structural responses and controller for calculating optimal input current are necessary, which deteriorate the economical efficiency. This study presents a MR damper generating frictional force of which magnitude is controlled in accordance to the displacement and velocity transferred to the damper. Numerical analyses results indicate that the performance of the response dependent MR damper is closely related with the range of the friction force and it can be designed to short better control performance than the passive MR damper.

  • PDF

리니어 모터에 근거한 능동 임피던스 구현 (Implementation of Active Impedance Based on Linear Motors)

  • 이세한;송재복;김용일
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.462-465
    • /
    • 1995
  • In this research a 2-dimensional motion producer based on two linear motors was developed. When the tester provides some motion through the level attached to the upper moving part of the motion producer, it provides the arbitrary intertia, damping and stiffness characteristics without actual change in physical structure of the motion producer. That is, the active impedance is implemented by controlling input currents supplied to the linear motors. A PID controller with feedforward loop was used to control the currents and pre-processing of input velocity and accleration singals from the encoder and the current singnal from the motor driver circuit are conducted to improve the performance.

  • PDF

An Over Current Protection Scheme for Hybrid Active Power filter

  • Lee Woo-Cheol;Chae Beom-Seok;Hyun Dong-Seok;Lee Taeck-Kie
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.571-575
    • /
    • 2001
  • A protection scheme for hybrid active power filters, which is combined shunt passive filter and small rated series active filter, is presented and analyzed in this paper. The proposed series active power filter operated as a high impedance 'k($\Omega$)' to the fundamental component when over current occurs in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame (SRF) and the third is the method by detecting the input voltage. When the over current occurs in the power distribution system, the proposed scheme protects the series active power filter without additional protection circuits. The validity of proposed protection scheme is investigated through experimental result for the prototype hybrid active power filter system.

  • PDF

능동 클램프 방식을 이용한 AC/DC ZVT 승압형 컨버터의 평균전류모드 제어에 관한 연구 (A Study on the Average Current-Mode Control AC/DC ZVT-Boost Converter with Active-Clamp Method)

  • 배진용;김용;김필수;임남혁;윤석호;장성원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1005-1008
    • /
    • 2001
  • This paper presents average current-mode control AC/DC ZVT(Zero Voltage Transition) Boost Converter. This boost converter perceives feed forward signal of input and feedback signal of output for average current-mode control proposed converter employs active-clamp method for ZVT. This converter gives the good PFC(Power Factor Correction), low line current hormonic distortions and tight output voltage regulations. This converter also has a high efficiency by active-clamp method. The principle of operation, feature, and design considerations are illustrated and verified through the experiment with a 150W, 120kHz prototype converter.

  • PDF