• Title/Summary/Keyword: Active Tilt

Search Result 76, Processing Time 0.025 seconds

Effects of Passive Scapular Postural Correction and Active Scapular Posterior Tilt Strategies on Peri-scapular Muscle Activation (수동적 어깨뼈 자세 교정 전략과 능동적 어깨뼈 뒤쪽 기울임 전략이 어깨뼈 주변근육 활성도에 미치는 영향)

  • Kang, Min-Hyeok
    • PNF and Movement
    • /
    • v.20 no.2
    • /
    • pp.215-222
    • /
    • 2022
  • Purpose: The purpose of this study was to compare the effects of passive scapular upward rotation and posterior tilt and active scapular posterior tilt on the muscle activity of the upper trapezius (UT), lower trapezius (LT), and serratus anterior (SA). Methods: Fifteen healthy subjects performed general arm elevation, arm elevation with passive scapular upward rotation and posterior tilt, and arm elevation with active scapular posterior tilt. For active scapular posterior tilt, the subjects were trained in this movement using visual biofeedback and a motion sensor. During each arm elevation condition, electromyography was used to measure the muscle activity of the UT, LT, and SA. The measured data were analyzed using a one-way repeated ANOVA. Results: LT muscle activity was significantly increased during arm elevation with active scapular posterior tilt compared to both general arm elevation and arm elevation with passive scapular upward rotation and posterior tilt (p < 0.05). SA muscle activity was greater during arm elevation with passive scapular upward rotation and posterior tilt than during general arm elevation (p < 0.05). There was no significant change in UT muscle activity among the tested arm elevation conditions (p > 0.05). Conclusion: Performing arm elevation with active scapular posterior tilt and performing arm elevation with passive scapular upward rotation and posterior tilt may be useful strategies for increasing muscle activation of the LT and SA, respectively.

ACTIVE DIRECT TILT CONTROL FOR STABILITY ENHANCEMENT OF A NARROW COMMUTER VEHICLE

  • Piyabongkarn, D.;Keviczky, T.;Rajamant, R.
    • International Journal of Automotive Technology
    • /
    • v.5 no.2
    • /
    • pp.77-88
    • /
    • 2004
  • Narrow commuter vehicles can address many congestion, parking and pollution issues associated with urban transportation. In making narrow vehicles safe, comfortable and acceptable to the public, active tilt control systems are likely to playa crucial role. This paper focuses on the development of an active direct tilt control system for a narrow vehicle that utilizes an actuator in the vehicle suspension. A simple PD controller can stabilize the tilt dynamics of the vehicle to any desired tilt angle. However, the challenges in the tilt control system design arise in determining the desired lean angle in real-time and in minimizing tilt actuator torque requirements. Minimizing torque requirements requires the tilting and turning of the vehicle to be synchronized as closely as possible. This paper explores two different control design approaches to meet these challenges. A Receding Horizon Controller (RHC) is first developed so as to systematically incorporate preview on road curvature and synchronize tilting with driver initiated turning. Second, a nonlinear control system that utilizes feedback linearization is developed and found to be effective in reducing torque. A close analysis of the complex feedback linearization controller provides insight into which terms are important for reducing actuator effort. This is used to reduce controller complexity and obtain a simple nonlinear controller that provides good performance.

The Assessment on Electromyography of Trunk Muscle according to Passive and Active Trunk Tilt Exercise of 3-D Dynamic Postural Balance Training System (3 차원 동적 자세균형 훈련기기의 능동/수동 체간 기울임에 따른 근 활성도 비교)

  • Shin, Sun Hye;Yu, Mi;Jeong, Gu Young;Yu, Chang Ho;Kim, Kyung;Jeong, Ho Choon;Kwon, Tae Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.3
    • /
    • pp.331-339
    • /
    • 2013
  • The Interest in disease prevention and rehabilitation is increasing depending on increase of patients with spinal. This is being developed using the spine stabilization device is being studied. So far studies have only evaluated the effect on trunk stabilization exercises but analysis of human movement patterns for active movement and passive movement did not. We assessed the muscle activity of trunk and leg muscle during passive and active tilt mode on eight tilt directions at tilt angle of $30^{\circ}$ using 3-D dynamic postural balance training system. We performed experimental study on the muscular activities of trunk muscle about rectus abdominis, external obliques, latissimus dorsi, erector spinae, and leg muscle about rectus femoris, Biceps femoris, Tibialis Anterior, gastrocnemius. As a result, muscle activation was different depending on the direction of movement and pattern. The results indicate that various patterns of spinal stabilization exercise system could be applied to an effective training of chronic low back pain patients.

Effects of Trunk Stabilization Exercise Using Active Vibration on Spinal Alignment in Normal Adult Females: A Randomized Controlled Trial

  • Park, Sunghwan;Kim, Yongseong;Park, Chibok
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.4
    • /
    • pp.2184-2190
    • /
    • 2020
  • Background: Although studies have been conducted on muscle thickness and balance in trunk stabilization exercise and exercise using vibration props, studies on trunk stabilization exercise using active vibration for spinal alignment are still insufficient to draw a conclusion. Objectives: To investigate the effect of trunk stabilization exercise using active vibration on the spinal alignment in adult females. Design: A randomized controlled trial. Methods: Twenty-six adult females were randomly assigned to the experimental group (active vibration) and 13 control groups (active non-vibrating) and exercised three times a week for 8 weeks. Each group was measured for spinal alignment before exercise and 8 weeks after exercise. Spinal alignment, trunk imbalance, pelvic tilt, and pelvic torsion were measured using a spinal alignment analyzer. Results: Trunk imbalance was a significantly different depending on the time in the experimental group and the control group (P<.05). Pelvic tilt was a significant difference between the groups (P<.05). Also, pelvic tilt was a significantly different depending on the time in the experimental group (P<.05), but the control group showed no significant difference (P>.05). Pelvic torsion was no significant difference in both groups (P>.05). Conclusion: This study demonstrates that trunk stabilization exercise using active vibration has a positive effect on the alignment of the spine.

Effect of Pelvic Compression Belt on Abdominal Muscle Activity, Pelvic Rotation and Pelvic Tilt During Active Straight Leg Raise

  • Jo, Eun-young;An, Duk-hyun
    • Physical Therapy Korea
    • /
    • v.26 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Background: Uncontrolled lumbopelvic movement leads to asymmetric symptoms and causes pain in the lumbar and pelvic regions. So many patients have uncontrolled lumbopelvic movement. Passive support devices are used for unstable lumbopelvic patient. So, we need to understand that influence of passive support on lumbopelvic stability. It is important to examine that using the pelvic belt on abdominal muscle activity, pelvic rotation and pelvic tilt. Objects: This study observed abdominal muscle activity, pelvic rotation and tilt angles were compared during active straight leg raise (ASLR) with and without pelvic compression belt. Methods: Sixteen healthy women were participated in this study. ASRL with and without pelvic compression belt was performed for 5 sec, until their leg touched the target bar that was set 20 cm above the base. Surface electromyography was recorded from rectus abdominis (RA), internal oblique abdominis (IO), and external oblique abdominis (EO) bilaterally. And pelvic rotation and tilt angles were measured by motion capture system. Results: There were significantly less activities of left EO (p=.042), right EO (p=.031), left IO (p=.039), right IO (p=.019), left RA (p=.044), and right RA (p=.042) and a greater right pelvic rotation angle (p=.008) and anterior pelvic tilt angle (p<.001) during ASLR with pelvic compression belt. Conclusion: These results showed that abdominal activity was reduced while the right pelvic rotation angle and anterior pelvic tilt angle were increased during ASLR with a pelvic compression belt. In other words, although pelvic compression belt could support abdominal muscle activity, it would be difficult to control pelvic movement. So pelvic belt would not be useful for controlled ASLR.

Pan/Tilt Camera System using Real-Time ELSAC and Stop/Go Procedure (실시간 ELSAC을 이용한 Stop/Go 방식의 Pan/Tilt 카메라 시스템)

  • Lee, Suk-Ho
    • Journal of Broadcast Engineering
    • /
    • v.17 no.6
    • /
    • pp.1106-1109
    • /
    • 2012
  • The stability of object tracking in non-stationary camera environment, such as intelligent surveillance system using a pan/tilt camera, is less stable compared with stationary camera environment. This is due to the fact that it is difficult to model a background image in non-stationary environment. In this letter, we propose a non-stationay pan/tilt camera surveillance system which uses a stop/go procedure together with a real-time active contour. The proposed system can track the object stable even in an environment where only a few difference frames can be obtained.

Improved ultrasonic beacon system for indoor localization

  • Shin, Su-Young;Choi, Jong-Suk;Kim, Byoung-Hoon;Park, Mi-Gnong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1775-1780
    • /
    • 2005
  • One of the most important factors so that mobile objects can achieve their purpose is the information about their positions. In this paper, we propose an improved beacon system, to which ultrasonic sensors are attached, for the indoor localization of mobile objects. We have researched so that it can cover the wider space and estimate more accurate positions than the existent beacon systems. The existent beacon systems have the constraint that one beacon cannot cover wide area since ultrasonic sensors have limits in the angle of signal (beam-angle) on which their signal strength depends. Hence, we used the active beacon which consists of a pan-tilt mechanism and a beacon module. The active beacon system can always aim at mobile objects in order to transmit the strongest signal of the ultrasonic sensors into the objects using the pan-tilt mechanism. In addition, this system is inexpensive because it can decrease the number of beacons by about a half of the beacons of the existent system. Finally, the results show what is the difference between the active beacon system and existent beacon systems, and how accurate it is.

  • PDF

Development of the Active Steering Tilt Controller for Stability of the Narrow Commuter Vehicles (폭이 좁은 차량의 안정성 향상을 위한 능동형 스티어링 기울임 제어기의 개발)

  • 소상균
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.2
    • /
    • pp.107-117
    • /
    • 1998
  • As the traffic congestion and parking problems in urban areas are increased the tall and narrow commuter vehicles have interested as a means to increase the utilization of existing freewa- ys and parking facilities. However, in hard cornering those vehicles could reduce stability against overturning compared to conventional vehicles. This tendency can be mitigated by tilting the body toward the inside of the turn. In this paper those tilting vehicles are considered in which at speed at least, the tilt angle is controlled by steering the front wheels. In other word, if the driver turns the steering wheel the tilt controller automatically steers the road wheel to tilt the body inside of the turn. Also, the dynamic tilting vehicle model with tire slip angles is constructed by adding the roll degree of freedom. Finally, through computer simulation the behaviors of the tilting vehicles are investigated.

  • PDF

Development of 3-Axis Actuator for Active Tilt Compensation (틸트 구동형 엑추에이터의 개발)

  • 이강녕;박세준;이동주;박노철;조원익;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.226-233
    • /
    • 2003
  • There are many researches going on to develop the information storage devices using Blue-ray disc and DVD as a demand for high-density information storage devices is highly increasing. This high-density information storage device requires a short-wave laser and objective lens of high numerical aperture set in fer its operation. And, that brings out rapid decrease of tilt tolerance. Therefore, it is necessary that an actuator should control tilt motions to get a stable signal. In this paper, a new mathematical form of 3-D.O.F coupled model is formulated and magnetic circuit in constraints is most effectively designed with the use of the moving coil type actuator in higher sensitivity. Further, this paper presents a tilt coil whose rotational center point is put on that of the lens through the variation of tilt coil and proposes a 3-axis actuator with high sensitivity improved in its dynamic property through its structure analysis.

  • PDF

A Study on the New Active Tilt Control Systems for Improving Passenger′s Feeling of Ground Vehicles in Urban Area (도시형 지상 차량의 승차감 향상을 위한 새로운 능동형 기울임 제어 시스템에 관한 연구)

  • 소상균;변기식
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.2
    • /
    • pp.103-110
    • /
    • 2001
  • To reduce the traffic congestion and parking problems in urban areas tall and narrow vehicles have interested as a means to increase the utilization of existing freeways and parking facilities. The stability problem for those narrow vehicles which might be caused can be reduced by tilting the body toward the inside of the turn. The Direct Tilt Control(DTC) system and the Steering Tilt Control(STC) system have been proposed for those narrow vehicles. In this paper, as one of the performance improvement for that kind of vehicle a new control system to use the merits of both the DTC system and the STC system is proposed. Because two different control systems fight each other, the switching control scheme is applied as a means to prevent fighting. Also, the method in order to achieve the smoothly changed control system when the system is switched from the DTC to the STC or from the STC to the DTC, the appropriate type of control gain is designed.

  • PDF