• 제목/요약/키워드: Active Thermal Control

검색결과 127건 처리시간 0.027초

나노임프린트 장비용 대면적 열판 열설계를 위한 수치 연구 (A NUMERICAL STUDY ON THERMAL DESIGN OF A LARGE-AREA HOT PLATE FOR THERMAL NANOIMPRINT LITHOGRAPHY)

  • 박규진;이재종;곽호상
    • 한국전산유체공학회지
    • /
    • 제21권2호
    • /
    • pp.90-98
    • /
    • 2016
  • A numerical study is conducted on thermal performance of a large-area hot plate specially designed as a heating and cooling tool for thermal nanoimprint lithography process. The hot plate has a dimension of $240mm{\times}240mm{\times}20mm$, in which a series of cartridge heaters and cooling holes are installed. The material is stainless steel selected for enduring the high molding pressure. A numerical model based on the ANSYS Fluent is employed to predict the thermal behavior of the hot plate both in heating and cooling phases. The PID thermal control of the device is modeled by adding user defined functions. The results of numerical computation demonstrate that the use of cartridge heaters provides sufficient heat-up performance and the active liquid cooling in the cooling holes provides the required cool-down performance. However, a crucial technical issue is raised that the proposed design poses a large temperature non-uniformity in the steady heating phase and in the transient cooling phase. As a remedy, a new hot plate in which heat pipes are installed in the cooling holes is considered. The numerical results show that the installation of heat pipes could enhance the temperature uniformity both in the heating and cooling phases.

가공공정 최적화 및 무인화를 위한 요소기술 분석 연구 (Key Technology Analysis for Machining Process Optimization and Automation)

  • 김동훈;송준엽
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.179-184
    • /
    • 2013
  • In this article, we introduce the study case of technology that can automatically compensate the errors of these factors of a machine during processing on the machine tool's CNC(Computerized Numerical Controller) in real time. The biggest factors that lower the machining accuracy are thermal deformation and chatter vibration. This study is related to the detection and compensation of thermal deformation and chatter vibration that can compensate for faster and produce processed goods with more precision by autonomous compensation. In addition, this study is related to the active control of vibration during machining, monitoring of cutting force and auto recognition of machining axes origin. Thus, we attempt to introduce the related contents of the development we have made in this article.

비축대칭 대류열손실 경계조건하에서 원관내 복사에 관여하는 매질의 층류 열적 발달의 수치해석 (Analysis on the thermal development of radiatively participating pipe flow with nonaxisymmetric convective heat loss)

  • 김택영;백승욱
    • 대한기계학회논문집
    • /
    • 제19권11호
    • /
    • pp.2995-3002
    • /
    • 1995
  • The cooling problem of the hot internal pipe flow has been investigated. Simultaneous conduction, convection, and radiation were considered with azimuthally varying convective heat loss at the pipe wall. A complex, nonlinear integro-differential radiative transfer equation was solved by the discrete ordinates method (or called S$_{N}$ method). The energy equation was solved by control volume based finite difference technique. A parametric study was performed by varying the conduction-to-radiation parameter, optical thickness, and scattering albedo. The results have shown that initially the radiatively active medium could be more efficiently cooled down compared with the cases otherwise. But even for the case with dominant radiation, as the medium temperature was lowered, the contribution of conduction became to exceed that of radiation.n.

열전소자를 이용한 정밀 항온 유지 장치에 관한 실험 및 시뮬레이션 연구 (A study on a precision temperature control unit using thermoelectirc module)

  • 박경서;송영중;임홍재;장시열;이기성;정재일;신동훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1937-1941
    • /
    • 2007
  • During a process of a nanoimprint for manufacturing LCD, a small temperature variation on the LCD glass can cause thermal stress and generate unexpected displacement. To avoid this trouble, a precision temperature control unit using thermoelectric modules is appropriate for nanoimprint processes. The unit consists of an air control system, a cooling water control system, and a power control system. The air control system includes a thermoelectric module, thermocouples measuring temperatures of air and a duct-stale fin, and two air fans. The heat generated by the thermoelectric module is absorbed by the cooling water control system. The power control system catches the temperature of the thermoelectric module, and a PID controller with SCR controls the input power of the thermoelectric module. Temperature control performance is evaluated by experiment and simulation. The temperature control unit is able to control the exit temperature about ${\pm}2^{\circ}C$ from the incoming fluid temperature, and the error range is ${\pm}0.1^{\circ}C$. However, the control time is approximately 30minute, which needs further study of active control

  • PDF

디지털중계기의 부하경감 및 이득조정기능 분석을 통한 열진공시험결과 성능분석 (Study on Thermal Vacuum Test Result of DCAMP by the Analysis of Derating & Gain Control)

  • 진병일;고현석
    • 한국항공우주학회지
    • /
    • 제43권1호
    • /
    • pp.72-78
    • /
    • 2015
  • 오늘날 위성은 통신, 기상, 해양탐사, 광학, 레이다등 민수분야에서 군사분야까지 폭넓게 적용되어 그 유용성이 점점 더 증가되고 있다. 또한, 부품기술의 발달로 위성 전장품의 기능도 더욱 능동적인 형태로 진화되고 있다. 위성선진국에서는 통신위성의 중계기 효율을 증가시키고, 간섭신호를 제거하여 가입자 서비스 품질을 유지하기 위해서 디지털중계기를 탑재하고 있다. 디지털중계기는 다양한 기능구현을 위해 신호처리용 부품들을 다수 사용한다. 따라서, 기존의 수동형 중계기에 비해 많은 전력을 소모하여 더 높은 발열 상태를 유지한다. 본 논문에서는 우주인증모델(EQM)급으로 자체 제작된 디지털중계기 열진공 시험결과의 성능을 분석한다. 열진공시험과정중 디지털중계기의 기능검증을 위해 디지털 이득조정 시험결과를 제시한다. 또한, 열진공 시험결과를 근거로 주요부품의 부하경감(Derating)을 분석하여 디지털중계기 설계의 적절성을 논의한다.

Mathematical modeling of actively controlled piezo smart structures: a review

  • Gupta, Vivek;Sharma, Manu;Thakur, Nagesh
    • Smart Structures and Systems
    • /
    • 제8권3호
    • /
    • pp.275-302
    • /
    • 2011
  • This is a review paper on mathematical modeling of actively controlled piezo smart structures. Paper has four sections to discuss the techniques to: (i) write the equations of motion (ii) implement sensor-actuator design (iii) model real life environmental effects and, (iv) control structural vibrations. In section (i), methods of writing equations of motion using equilibrium relations, Hamilton's principle, finite element technique and modal testing are discussed. In section (ii), self-sensing actuators, extension-bending actuators, shear actuators and modal sensors/actuators are discussed. In section (iii), modeling of thermal, hygro and other non-linear effects is discussed. Finally in section (iv), various vibration control techniques and useful software are mentioned. This review has two objectives: (i) practicing engineers can pick the most suitable philosophy for their end application and, (ii) researchers can come to know how the field has evolved, how it can be extended to real life structures and what the potential gaps in the literature are.

최적 파라미터를 이용한 단순 모델 기반 바닥 난방 시스템 모델링 (Simple Modeling of Floor Heating Systems based on Optimal Parameter Settings)

  • 박승훈;장용성;김의종
    • 설비공학논문집
    • /
    • 제29권9호
    • /
    • pp.472-481
    • /
    • 2017
  • Radiant floor heating systems have been used as common heating supply systems in most residential buildings in Korea. Since the system uses a floor as thermal storage, proper control strategy should be adopted to avoid over-or under-heating problems. So far, studies related to control of the floor heating system have been conducted based on computer simulations. The active layer in TRNSYS is known for its usability as a floor heating system model and is integrated with the TRNSYS building model (Type 56). However, floor heating system simulations with the active layer are operated only if pre-defined minimum mass flow rate is ensured. This study proposes a simple RC (Resistance-Capacitance) model for radiant floor heating systems. Model parameters such as Rs and Cs are defined by optimization. The active layer, in this study, is used as the target system to search for optimal values. A TRNOPT optimization tool was used to conduct optimization under given simulation conditions. The RC model with optimal parameters are tested in other mass flow rates that were not used during optimization. Results reveal the RC model describes the active layer with successfully optimized model parameters. The RC model has fewer model limitations, and is expected to be used for various target systems, e.g. experimental data of a real radiant heating system.

고전압맥동전류에 의한 일차 및 이차통각과민대의 RIII 반사의 변화 (Change of RIII Reflex of Primary and Secondary Hyperalgesia Site by High Voltage Pulsed Current)

  • 김수현;최석주;이정우;정진규;김태열;김계엽
    • 대한임상전기생리학회지
    • /
    • 제4권1호
    • /
    • pp.1-12
    • /
    • 2006
  • This study conducted RIII reflex measurement to examine degree of pain depending on polarity of high voltage pulsed current of primary and secondary hyperalgesia site in hyperalgesia rat by local thermal injury. Hind paw which was injury site was taken as primary hyperalgeisa site, sole which was injury adjacent site was taken as secondary hyperalgesia site, and mechanical pain threshold, thermal pain threshold and root mean square of RIII reflex were measured. This study was conducted with control group I of hyperalgesia rat at hind paw by thermal injury and experimental groups divided into cathodal high voltage treatment group II, anodal high voltage treatment group III and alternate high voltage treatment group IV, applied active electrode of high voltage pulsed current to hind paw directly, placed reference electrode on the sole of injury adjacent site and applied pulse frequency. It measured RIII reflex and obtained the following results: Root mean square of RIII reflex at primary hyperalgeisa site was significantly reduced in group II after 2 days of hyperalgesia. Group II showed significant decrease after 5 and 6 days of hyperalgesia. Root mean square of RIII reflex at secondary hyperalgesia site showed significant reduction in group II after 6 days of hyperalgesia. Consequently it was found that application of high voltage pulsed current of hyperalgesia site reduced RIII reflex at primary hyperalgeisa site and secondary hyperalgesia site by electrical stimuli. Effects by polarity of high voltage pulsed current showed the greatest reduction of pain threshold when cathodal active electrode was used.

  • PDF

마이크로 연소기에서 발생하는 열 소염과 화학 소염 현상 (II)- SiOx(x≤2) 플레이트의 물리, 화학적 성질이 소염에 미치는 영향 - (Thermal and Chemical Quenching Phenomena in a Microscale Combustor (II)- Effects of Physical and Chemical Properties of SiOx(x≤2) Plates on flame Quenching -)

  • 김규태;이대훈;권세진
    • 대한기계학회논문집B
    • /
    • 제30권5호
    • /
    • pp.405-412
    • /
    • 2006
  • In order to realize a stably propagating flame in a narrow channel, flame instabilities resulting from flame-wall interaction should be avoided. In particular flame quenching is a significant issue in micro combustion devices; quenching is caused either by excessive heat loss or by active radical adsorptions at the wall. In this paper, the relative significance of thermal and chemical effects on flame quenching is examined by means of quenching distance measurement. Emphasis is placed on the effects of surface defect density on flame quenching. To investigate chemical quenching phenomenon, thermally grown silicon oxide plates with well-defined defect distribution were prepared. ion implantation technique was used to control defect density, i.e. the number of oxygen vacancies. It has been found that when the surface temperature is under $300^{\circ}C$, the quenching distance is decreased on account of reduced heat loss; as the surface temperature is increased over $300^{\circ}C$, however, quenching distance is increased despite reduced heat loss effect. Such abberant behavior is caused by heterogeneous surface reactions between active radicals and surface defects. The higher defect density, the larger quenching distance. This result means that chemical quenching is governed by radical adsorption that can be parameterized by oxygen vacancy density on the surface.

슬관절 전치환술 환자의 저체온 관리를 위한 ASPAN의 근거기반 임상실무 가이드라인 적용 효과 (Effects of ASPAN's Evidence-based Clinical Practice Guidelines for Promotion of Hypothermia of Patients with Total Knee Replacement Arthroplasty)

  • 유제복;박현주;채지연;이은주;신유정;고저스틴상욱;김남초
    • 대한간호학회지
    • /
    • 제43권3호
    • /
    • pp.352-360
    • /
    • 2013
  • Purpose: In this study an examination was done of the effects of the American Society of PeriAnesthesia Nurses (ASPAN) Evidence-Based Clinical Practice Guidelines on body temperature, shivering, thermal discomfort, and time to achieve normothermia in patients undergoing total knee replacement arthroplasty (TKRA) under spinal anesthesia. Methods: This study was an experimental study with a randomized controlled trial design. Participants (n=60) were patients who underwent TKRA between December 2011 and March 2012. Experimental group (n=30) received active and passive warming measures as described in the ASPAN's guidelines. Control group (n=30) received traditional care. Body temperature, shivering, thermal discomfort, time to achieve normothermia were measured in both groups at 30 minute intervals. Results: Experimental group had slightly higher body temperature compared to control group (p=.002). Thermal discomfort was higher in the experimental group before surgery but higher in the control group after surgery (p=.034). It decreased after surgery (p=.041) in both groups. Time to achieve normothermia was shorter in the experimental group (p=.010). Conclusion: ASPAN's guidelines provide guidance on measuring patient body temperature at regular intervals and on individualized and differentiated hypothermia management which can be very useful in nursing care, particularly in protecting patient safety and improving quality of nursing.