• Title/Summary/Keyword: Active Inductor

Search Result 164, Processing Time 0.028 seconds

Analysis and Design of Quadruple-Active-Bridge Converter Employing Passive Power Decoupling Capability (수동 전력 비동조화가 가능한 QAB 컨버터의 분석과 설계에 관한 연구)

  • Yun, Chang-Woo;Lee, Jun-Young;Baek, Ju-Won;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.157-164
    • /
    • 2022
  • This study proposes an enhanced quadruple-Active-Bridge (QAB) converter that can solve power coupling problems. By adopting a multiple winding transformer, the equivalent circuit of a conventional QAB converter has power couplings between arbitrary output ports. This coupling is an unintended power relationship that complicates the regulation of output voltage of the multiple ports. The proposed converter can carry out power decoupling by changing the arrangement of the coupling inductor. Power transfer equations for the proposed converter and its operating principles are analyzed in detail. The power coupling caused by the transformer's leakage inductance is verified by using a proposed coupling factor that presents the relationship between inductance ratio and coupling power. In addition, the decoupling power control performance of the proposed converter is verified by simulation and a 3 kW prototype converter.

An Improved ZVS Active Clamp Forward Converter (개선된 영전압 스위칭 액티브 클램프 포워드 컨버터)

  • Choi Sun-Ho;Lee Hyun-Kwan;Kim Eun-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.302-311
    • /
    • 2005
  • We propose an improved active forward converter by adding a non-dissipative snubber circuit to the secondary of the conventional active clamp forward converter in this paper. The snubber circuit is composed of a tapped inductor, a snubber capacitor, and two diodes. Comparing with the conventional one, the proposed one makes it possible ZVS to operate in a smaller magnetizing current condition. The operational principles and the equivalent mode analysis of an improved active forward converter are mentioned in this paper. In conclusion, we constructed the prototype of the modified active forward converter with 300W output capacity and verified higher efficiency compared to the conventional one.

A novel resonant pulse control in resonant DC link inverter (공진형 직류 링크 인버터의 공진 펄스 제어기)

  • 유동욱;원충연
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.5
    • /
    • pp.152-158
    • /
    • 1996
  • A novel resonant pulse control technique which generates high-quality sinusoidal output voltage from a resonant dc link inverter is presented for UPS applicatons. The proposed control technique limits resonant voltae overshoot without any passive or active clamp circuit, resulting in resonant pulses iwth uniform amplitude and high efficiency. The output voltage is controlled by the third order contorller iwth an inner loop of th efilter inductor current and the feedforward controller. Analysis and design of the proposed control technique are illustrated and verified on a 5kVA experimental unit.

  • PDF

Comparision of Inductor Current Characteristic between Single-PWM and Dual-PWM in the Dual Active Bridge Converter (듀얼 액티브 브릿지에서 Single-PWM과 Dual-PWM 간의 인덕터 전류의 특성 비교)

  • Byen, Byeng Joo;Jeong, B.H.;Choe, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.109-110
    • /
    • 2017
  • 본 논문에서는 듀얼 액티브 브릿지에서 SPWM(Single Pulse Width Modulaton)과 DPWM(Dual Pulse Witdh Modulation)을 적용하였을 때, 인덕터 전류의 특성을 비교하고자 한다. 인덕터 전류의 특성을 이론적으로 분석하고, 실험을 통해서 결과를 분석하였다.

  • PDF

A Bidirectional Hybrid Switching Full-Bridge Converter with Active Clamp Circuit for V2G Applications (V2G 응용을 위한 능동클램프 회로를 가진 양방향 하이브리드 스위칭 풀브리지 컨버터)

  • Vuand, Hai-Nam;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.335-336
    • /
    • 2016
  • This paper introduces a bidirectional full-bridge converter with new active damp structure. The proposed active damp circuit can damp the oscillating voltage across the rectifier diodes with a smaller voltage stress of the damping capacitor and eliminate the circulating current. In addition, the proposed converter can achieve additional advantages such as nearly ZCS switching for leading-leg switches and no recovery current for rectifier-bridge by the suitable design of the damp capacitor to resonate with leakage inductor. Since the ZVS is achieved for both leading-leg and lagging-leg switches by the magnetizing current of the transformer, it can be achieved regardless of the load variation. A 3.3 kW prototype converter is implemented for vehicle-to-grid (V2G) application and the advantages of the proposed converter are verified by the experiments. The maximum efficiencies of 98.2% and 97.6% have been achieved for the buck mode and boost mode operation, respectively.

  • PDF

Single-Phase Active Power Filter for Higher-order Harmonic Current Compensation (고차 고조파 전류의 보상을 위한 단상 능동전력필터)

  • Sung, Ki-Suk;Woo, Myung-Ho;Song, Joong-Ho;Choy, Ick;Lim, Myo-Taeg
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.7
    • /
    • pp.500-508
    • /
    • 2000
  • Basic design for single-phase active power filter, which aims at railway application provided with PWM-controlled converters, is comprehensively studied and its performance is presented in this paper. Active power filters are used to compensate railway signaling and public telecommunication interference due to the high-order harmonic currents generated in railway traction locomotives. A type of hybrid digital filter which is composed of low pass filter and high pass filter is proposed so that the desired harmonic reference current with accurate magnitude and phase shift can be extracted from catenary line current. A design criteria to determine input inductor L and output capacitor C is also described, considering voltage, current, PWM pattern, and switching frequency of the main converters. Finally, computer simulation and DSP-based experiments resulted from laboratory test are presented.

  • PDF

Soft Switching PWM Converter Using a New Active Snubber (새로운 액티브 스너버를 이용한 소프트 스위칭 PWM 컨버터)

  • Cho, M.C.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.;Kwan, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.261-263
    • /
    • 2006
  • A new soft switched active snubber circuit is proposed to achieve zero voltage and zero current switching for all the switching devices in PWM DC-DC converters. The unique location of the snubber and inductor ensures low current/voltage stresses and commutation losses. With a saturable reactor, the conduction loss of auxiliary switch could be further minimized. A boost converter adopting this technique is presented as an example, to illuminate its operation principles and derive the design procedures. Simulation and hardware implementation have been made to validate its performance. Some other basic PWM DC-DC topologies using the proposed snubber have also been given.

  • PDF

Character of PWM DC-DC Converter for Conduction Loss Reduction and Efficiency Rise (전도손실 저감 및 효율 상승을 위한 PWM DC-DC 컨버터의 특성)

  • Kim, M.Y.;Kim, H.J.;Kim, C.Y.;Lyu, J.Y.;Kim, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.125-127
    • /
    • 2007
  • Presented increase and so on of switch stress and switching dissipation and EMI that is happened in general PWM converter and in this study to solve problem the resonance energy return to life rate and new active snubber PWM converter because do maximization. Active snubber PWM converter that try adds auxiliary switch and resonance capacitor, diode to existing converter under all switching conditions turn on/off Minimised switching dissipation that occur. Reduced harmonic components absorbing station recovery electric current that happen to snubber diode inserting diode and resistance. And decreased peak current that is happened in auxiliary switch arranging resonance capacitor and inductor properly, Certified effect that efficiency rises about 2.5[%] more than existent PWM converter in rated load through an experiment.

  • PDF

A GaAs MMIC Single-Balanced Upconverting Mixer With Built-in Active Balun for PCS Applications (PCS 용 MMIC Single-blanced upconverting 주파수 혼합기 설계 및 제작)

  • 강현일;이원상;정기웅;오재응
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.4
    • /
    • pp.1-8
    • /
    • 1998
  • An MMIC single-balanced upconverting mixer for PCS application has been successfully developed using an MMIC process employed by 1 .mu. ion implanted GaAs MESFET and passive lumped elements consisting of spiral inductor, Si3N4 MIM capacitors and NiCr resistors. The configuration of the mixer presented in this paper is two balanced cascode FET mixers with common-source self-bias circuits for single power supply operation. The dimension of the fabricated circuit including two active baluns intermodulation characteristic with two-tone excitation are also measured, showing -28.17 dBc at IF power of -30 dBm.

  • PDF

Improved Zero Voltage and Zero Current Switching Full Bridge PWM Converter with Active Clamp

  • Baek, J.W.;Cho, J.G.;Jeong, C.Y.;Yoo, D.W.;Kim, H.G.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.687-693
    • /
    • 1998
  • An improved zero voltage and zero current switching (ZVZCS) full bridge (FB) PWM converter is proposed to solve the problems of the previously presented ZVACS-FB-PWM converter with secondary active clamp such as narrow ZVS range of leading-leg switches [6]. By adding an auxiliary inductor in between the leading-leg and separated input source voltages, the ZVS of leading leg switches can be extended to the whole line and load ranges, which eliminates unwanted hard switching of clamp switch and simplifies its control. The principle of operation is explained and analyzed. The features and design considerations of the proposed converter are also illustrated and verified on a 3 kW, 100 KHz IGBT based experimental circuit.

  • PDF