• 제목/요약/키워드: Active Frequency Drift

Search Result 39, Processing Time 0.028 seconds

Characteristics Analysis of RPV and AFD for Anti-Islanding in Active Method (단독운전방지를 위한 능동 방식 중 AFD 및 RPV에 대한 특성해석)

  • Choe, Gyu-Ha;D, Bayasgalan;Lee, Young-Jin;Han, Dong-Ha;Jeong, Byong-Hwan;Kim, Hong-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.160-167
    • /
    • 2009
  • To detect islanding mode when the grid is being tripped is a major safety issue in the Utility Interactive Photo Voltaic (UIPV) system. In this paper, analytical design method is suggested for AFD & RPV method under IEEE 929-2000 recommended islanding test condition. We have discussed that there is a same point. we injected reactive component of the current by AFD & RPV methods, but the current reference generated is other waveform. Possible if amount of reactive components in this methods are same each method, there is happened same rates frequency variation. To verify the validity of the analytical comparison, this paper presents simulation and experimental results from single phase, 3[kW] inverter for the transformerless UIPV system.

Evaluation the Non-Detection Zone of Anti-Islanding Methods (단독운전검출기법의 불검출 영역에 대한 비교 고찰)

  • Lee K. O.;So J. H.;Jung Y. S.;Yu G. J.;Choi J. Y.;Jung S. G.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.494-497
    • /
    • 2004
  • 계통연계형 태양광발전 시스템의 확대보급에 따라 단독운전 검출기법의 검출 성능에 대한 검증의 필요성이 대두되고 있다. 본 논문에서는 단독운전 검출기법의 대표적인 능동적 검출기법인 무효전력 변동기법 (reactive power variation method)과 주파수 쉬프트기법(active frequency drift method)을 IEEE Std 929-2000에서 명시된 단독운전검출 시험 방법을 이용하여 단독운전검출기법의 성능 및 불검출 영역(non-detection zone)에 대하여 비교 분석하였다.

  • PDF

Modeling and Analysis of modified active frequency drift method (개선된 AFD기법의 모델링 및 분석)

  • Lee, K.O.;Yu, B.G.;Yu, G.J.;Choi, J.Y.;Choy, I.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.172-173
    • /
    • 2010
  • 본 논문은 신 재생에너지원 중 태양광을 이용한 계통연계형 PV PCS의 단독운전 검출 성능을 극대화하고, 출력전력의 품질 외곡을 최소화 할 수 있는 개선된 능동 주파수 변이기법의 최적 외란의 크기를 모델링, 시뮬레이션 및 실험을 통하여 검증하고, 이를 근거로 계통 보호 협조 및 안전을 위한 단독운전 검출 기법의 설계방법을 제시하고자 한다.

  • PDF

Evaluation the Non-Detection Zone of Anti-Islanding Methods (단독운전검출기법의 불검출 영역에 대한 비교 고찰)

  • Lee K.O;So J.H;Jung Y.S;Yu G.J;Choi J.Y;Jung S.G;Choy I.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1480-1482
    • /
    • 2004
  • 계통연계형 태양광발전 시스템의 확대보급에 따라 단독운전 검출기법의 검출 성능에 대한 검증의 필요성이 대두되고 있다. 본 논문에서는 단독운전검출기법의 대표적인 능동적 검출기법인 무효전력변동기법 (reactive power variation method)과 주파수 쉬프트기법(active frequency drift method)을 IEEE Std 929-2000에서 명시된 단독운전검출 시험방법을 이용하여 단독운전검출기법의 성능 및 불검출 영역(non-detection zone)에 대하여 비교 분석하였다.

  • PDF

Anti-islanding Detection of a AFD Method applied to Grid Connected Micro Inverter (계통연계형 소용량 태양광 인버터에 적용된 AFD 방식의 단독운전 검출기법)

  • Kwak, Raeho;Lee, June Hee;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.524-525
    • /
    • 2015
  • 본 논문은 계통연계형 소용량 태양광 인버터에 적용된 AFD(Active Frequency Drift) 기반의 단독 운전 검출 기법을 제안한다. 태양광 시스템에 일반적인 인버터 토폴로지를 사용한 경우, 무효전력 주입을 이용하여 단독운전 검출이 가능하다. 하지만 무효전력의 제어가 불가능한 인버터를 사용한 경우에는 기존의 무효전력을 이용하는 단독운전 검출기법을 사용할 수 없다. 무효전력의 제어가 불가능한 인버터 토폴로지에 새로운 스위칭 기법을 적용하면 무효전력을 주입한 효과를 얻을 수 있고, 이를 통해 기존의 AFD 방식을 응용하여 단독운전 검출이 가능한 새로운 검출기법을 제안하였다. 제안하는 검출기법은 기존의 AFD 방식보다 인버터 출력전류의 THD (Total Harmonic Distortion)를 개선할 수 있는 장점이 있다. 제안하는 기법의 성능을 시뮬레이션을 통해 확인하였다.

  • PDF

An Analysis and Design of RPV and AFD Method for Anti-Islanding of Single-Phase UIPV System under The Test Condition Recommended by IEEE 929-2000 (IEEE 929-2000 단독운전 시험조건 하에서 단상 계통연계형 PV 시스템의 Anti-Islanding을 위한 RPV 방식 및 AFD방식의 해석 및 설계)

  • Kim, Hong-Sung;Kim, Han-Goo;Choe, Gyu-Ha;Kim, Jae-Chul;Choi, Yung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.37-49
    • /
    • 2007
  • To detect islanding mode when the grid is being tripped is a major safety issue in utility interactive PV(UIPV) system. Widely used techniques among various active methods to detect islanding mode are Reactive power variation (RPV)method and Active frequency drift(AFD) method. In this paper, analytical design method is suggested for AFD and RPV method under IEEE recommended islanding test condition. And in order to show the validity of proposed method, EMTP based simulation was done for UIPV system with RPV method and AFD method. Results shows proposed method is very useful.

Retrofitting of a weaker building by coupling it to an adjacent stronger building using MR dampers

  • Abdeddaim, Mahdi;Ounis, Abdelhafid;Shrimali, Mahendra K.;Datta, Tushar K.
    • Structural Engineering and Mechanics
    • /
    • v.62 no.2
    • /
    • pp.197-208
    • /
    • 2017
  • Among various retrofitting strategies, use of semi-active control for retrofitting a building structure has gained momentum in recent years. One of the techniques for such retrofitting is to connect a weaker building to an adjacent stronger building by semi-active devices, so that performances of a weaker building are significantly improved for seismic forces. In this paper, a ten storey weaker building is connected to an adjacent stronger building using magneto-rheological (MR) dampers, for primarily improving the performance of the weaker building in terms of displacement, drift and base shear. For this, a fuzzy logic controller is specifically developed by fuzzyfying the responses of the coupled system. The performance of the control strategy is compared with the passive-on and passive-off controls. Pounding Mitigation between the two buildings is also investigated using all three control strategies. The results show that there exists a fundamental frequency ratio between the two buildings for which maximum control of the weaker building response takes place with no penalty on the stronger building. There exists also a fundamental frequency ratio where control of the weaker building response is achieved at the expense of the amplification of the stronger building. However, coupling strategy always improves the possibility of pounding mitigation.

A Study on Kimchi Preference and the Types of Kimchi Purchased at Markets to Improve Kimchi Marketing (시판 김치의 선호도 및 구매 형태)

  • You, Jung-Hee;Kwak, Eun-Jung;Shin, Min-Ja
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.17 no.4
    • /
    • pp.511-519
    • /
    • 2007
  • This study was conducted to estimate the drift of change for kimchi purchase, and to contribute to quality improvement of kimchi sold at markets. Questionnaries were distributed to 450 adults and 396 were statistically analyzed. The methods used to analyze the items were frequency analysis, Chi-square, t-tests and ANOVA. The highest preference for kinds of kimchi was Beachoo kimchi, while the preference for Nabak kimchi was low. In terms of the degree of ripening, most subjects preferred properly ripened kimchi. With regard to the purchase amount the subjects preferred 1 kg and mainly purchased it once every three months at large market and supermarkets. The main reason for purchasing kimchi at markets was 'convenience', while the reason they didn't purchase it was 'it might contain artificial seasoning'. With regard to the development and improvement of the kimchi industry, the subjects belived that taste and ripening should be standardized, and that kimchi should be treated sanitarily. They acknowledged that kimchi products should be diversified, and active marketing should be carried out in order for it to be globalized.

  • PDF

Piezoelectric friction dampers for earthquake mitigation of buildings: design, fabrication, and characterization

  • Chen, Genda;Garrett, Gabriel T.;Chen, Chaoqiang;Cheng, Franklin Y.
    • Structural Engineering and Mechanics
    • /
    • v.17 no.3_4
    • /
    • pp.539-556
    • /
    • 2004
  • In this paper, the design, fabrication and characterization of a piezoelectric friction damper are presented. It was sized with the proposed practical procedure to minimize the story drift and floor acceleration of an existing 1/4-scale, three-story frame structure under both near-fault and far-field earthquakes. The design operation friction force in kip was numerically determined to range from 2.2 to 3.3 times the value of the peak ground acceleration in g (gravitational acceleration). Experimental results indicated that the load-displacement loop of the damper is nearly rectangular in shape and independent of the excitation frequency. The coefficient of friction of the damper is approximately 0.85 when the clamping force on the damper is above 400 lbs. It was found that the friction force variation of the damper generated by piezoelectric actuators with 1000 Volts is approximately 90% of the expected value. The properties of the damper are insensitive to its ambient temperature and remain almost the same after being tested for more than 12,000 cycles.