• 제목/요약/키워드: Active Factor

검색결과 2,087건 처리시간 0.029초

액티브 시니어의 체험 마케팅을 통한 브랜드 가치지각이 태도 형성 및 행동 의도에 미치는 영향 - 몰입 정도에 따른 비교를 중심으로 - (The impact on the value perception of brand by experiential marketing to the attitude formation and behavioral intentions on active seniors - Comparing of the level of commitment -)

  • 이상인;유지헌
    • 한국의상디자인학회지
    • /
    • 제23권4호
    • /
    • pp.1-17
    • /
    • 2021
  • This study was examined whether the experiential marketing factors proposed by Bernd Schmitt were applicable to the consumer behavior of active seniors. The study was analyzed the influence of SEMs have on value perception of brand and attitude formation as well as the behavioral intentions of active senior consumers and whether this effect differed between the level of commitment. For empirical analysis, frequency analysis, EFA, reliability, CFA, SEM, and multiple-group comparison analysis were performed. The results showed that sense and feel factor did not have a significant influence on the value perception of brand, while think factor had a positive effect on the value perception of brand. Act factor did not affect the value perception of brand; on the other hand, relate factor had a significant effect on the value perception of brand. The result of structural equation modeling also revealed that the value perception of brand had a positive influence on attitude formation and behavioral intentions. The result of multiple-group comparison analysis confirmed that the influence of act factor on value perception of brand differed according to the level of commitment, but the positive influence of act factor on value perception of brand was limited to the high-level of commitment group. As a result of the influence relate factor had on the value perception of brand, differences existed between the two groups, and the low-level of commitment group had a greater influence than the high-level of commitment group. So it will be effective for active senior consumers to form fashion communities and let them participate in to enhance positive consumer behavior toward fashion brands.

무손실 저항개념을 이용한 저전력 전원설비용 능동 역률보정기의 설계 (Design of Active Power Factor Corrector for Low Power Supply by Loss Free Resistor Concept)

  • 임영철;정영국;최찬학;나석환;이건식;장영학
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제7권1호
    • /
    • pp.30-36
    • /
    • 1993
  • 본 연구는 정류기의 입력전류에 포함되어 있는 고조파성분을 제거하고 입력역률을 개선하기 위해 무손실 저항(Loss Free Resistor) 개념에 기본을 둔, PC, 가전기기 및 형광등용 전자안정기등과 같은 저전력 전원설비에 적합한 불연속 도통모드(DCM) 플라이백 방식의 능동역률 보정기의 등가회로모델 및 설계법을 제시하였다. 이 개념에 의하여 능동역률 보정기의 등가입력저항, 출력전력원 특성을 정확하게 나타낼 수 있었으며 또 설계방정식을 유도하여 능동역률 보정기를 설계 시험한 결과, 적은 부품으로 정류기의 입력교류 전류에 포함되어 있는 고주파를 제거하였고 따라서 0.98의 고입력역률의 정류를 할 수 있었다.

  • PDF

능동 클램프 회로를 적용한 단상 ZCS 공진형 역률개선 컨버터 (An Integrated Single-Stage Zero Current Switched Quasi-Resonant Power Factor Correction Converter with Active Clamp Circuit)

  • 이준영;문건우;고관본;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.626-630
    • /
    • 1999
  • A new integrated single-stage zero current switched(ZCS) quasi-resonant converter (QRC) for the power factor correction(PFC) converter is introduced in this paper. The power factor correction can be achieved by the discontinuous conduction mode(DCM) operation of an input current. The proposed converter has the characteristics of the good power factor, low line current harmonics, and tight output regulation. Furthermore, the ringing effect due to the output capacitance of the main switch can be eliminated by use of active clamp circuit.

  • PDF

전류 제어 루프에 보상을 행하지 않는 능동 역률 제어 AC/DC 컴버터의 제어기 설계 (Design of active power factor control AC/DC converter having current control loop with no compensator)

  • 이인호;김성환;유지윤;박귀태
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.216-223
    • /
    • 1996
  • The active power factor control AC/DC converter needs a current loop compensator to obtain better dynamic characteristics and power factor performance, but the optimal design of a current loop compensator is difficult because the AC/DC converter is a nonlinear system having periodically varying poles and zeros. The predictive current control scheme generates a control input using the dynamic equations of the AC/DC converter so that the dynamic of the AC/DC converter is included in the controller and the necessary bandwidth and the gain characteristics of the current control loop are satisfied. And as a result, a compensator becomes unnecessary and the current loop shows the improved current loop characteristics. In this paper, a power factor controller without current loop compensator by adopting a predictive current control scheme is designed and the designed power factor controller is modelled by using a small signal perturbation modelling technique, and simulated to investigate its small signal characteristics. A 200 W power factor control AC/DC converter is built to verify the effectiveness of the proposed power factor controller.

  • PDF

정신과 근무 간호원의 정신질환 및 정신질환자에 대한 태도 연구 (A Study of the Attitudes of Psychiatric Registred Nurses towards Mental illness and Mental Patients)

  • 김향미
    • 대한간호학회지
    • /
    • 제12권1호
    • /
    • pp.13-24
    • /
    • 1982
  • The main purpose of this study was to investigate attitudes toward mental illness and the mentally ill of psychiatric nurses in Korea and to identify the relationships between the nurses' attitudes and demographic variables. Subjects in this study were 122 psychiatricnurses and 111non-psychiatric nurses in active service at 12 hospitals in Seoul. The insrtument used for measuring attitudes was a questionaire developed by Cohen and Struening (1962) referred to as the“Opinions about Mental illness(OMI) Scale”made up to 51 Likert-type items. The findings of this study indicated hatnurses showed negative attitudetoward mental illness and the mentally ill: Very high on social restrictiveness (factor D), low on Mental Health Ideology (factor C), and Interpersonal Etiology (factor E). Since the high score on Factor A, B and the low score on Factor B, C, E reflect a negative altitudes toward mental illness, this study population related extremely negative attitudes compared to any other surveys. And of the demographic variables that related to their attitudes the education degree and the kind of the hospital in active service showed very significant differences. On the basis of the investigation the findings indicated the followings; 1) Althohg attitudes toward mental illness and the mentally ill of psychiatric nurses were not significant differences from non-psychatric nurses, there was a trend that attitudes of psychaitric nurses did show more negative responses rather than those of non-psychiatric nurses. 2) Demographic variables that relate to their attitudes on the OMI scale were the education degree of the respondent and the kind of their hospital in active service. 3) About attitudes toward mental illness and the mentally ill baccalaureate nursesshowed more positive attitudes in Factor A (Authoritarianism), Factor C (Mental Health Ideology) and Factor D (Social Restrictiveness) than diploma program murses. 4) Nurses in active Service in the private hospital revealed more positive attitudes(A,B,C,D) except Factor (E) than those in the national or public hospital. 5) The ages, duration of work, wanted or unwantedG roup of psychiatric ward and satisfactory level of psychiatric nursing service were non-significant.

  • PDF

전력품질 개선을 위한 단상 전압제어형 능동전력필터 시스템에 관한 연구 (A Study on the Single Phase Voltage-Controlled Active Power Filter for Power Quality Improvement)

  • 손진근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권5호
    • /
    • pp.238-245
    • /
    • 2003
  • In this paper, a single Phase voltage source voltage-controlled active power filter(APF) for power quality improvement was proposed. The proposed APF has the performance of harmonic suppression and unity power factor correction. The performance of harmonic suppression can be obtained by controlling the waveshape of the APF output voltage to be sine wave. And, unity power factor is controlled by the reactive power control loop of the APF output. Simulation and experimental results using diode rectifier showed that the voltage-controlled APF, unlike the current-controlled APF, can reduce the voltage harmonics as well as current harmonics. Also the results showed that the input dover factor and power quality were greatly improved.

전원 불평형과 역률을 보상하는 직렬형 능동전력필터 (Series Active Power Filters for Source Voltage Unbalance Compensation and Power Factor Correction)

  • 장정익;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.498-500
    • /
    • 2005
  • This paper presents a unified control scheme for series-type active power filters combined with shunt passive filters for the source voltage unbalance compensation and the power factor correction simultaneously. The power factor correction is achieved by controlling the amplitude of reactive power current in a series filter as zero in a synchronously rotating reference frame. The proposed algorithm successfully compensates the source voltage unbalance and the power factor. The validity of the proposed scheme has been verified by simulation for a 3-kVA hybrid active power filter system.

  • PDF

높은 Q-지수를 갖는 대칭 구조의 CMOS 2 단자 능동 인덕터 (CMOS Symmetric High-Q 2-Port Active Inductor)

  • 구자건;정승호;정용채
    • 한국전자파학회논문지
    • /
    • 제27권10호
    • /
    • pp.877-882
    • /
    • 2016
  • 본 논문에서는 LC 공진회로를 이용한 2 단자 능동 인덕터를 제안한다. 제안된 회로는 기존 자이레이터 구조의 1 단자 능동 인덕터들을 캐스코드 형태로 결합하였으며, 두 자이레이터 사이에 LC 공진회로를 추가시켰다. LC 공진회로는 능동 인덕터를 구성하는 트랜지스터의 기생 성분들을 상쇄시킴으로써 넓은 대역에서 높은 Q-지수를 제공한다. 제안된 회로는 삼성전자 65 nm 공정을 이용하여 시뮬레이션과 제작을 수행하였으며, 1~6 GHz 대역에서 2 nH의 일정한 인덕턴스와 40 이상의 높은 Q-지수를 가진다.

고역률을 갖는 단일 전력변환 AC-DC 컨버터 (Single Power-conversion AC-DC Converter with High Power Factor)

  • 조용원;박천윤;권봉환
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.23-30
    • /
    • 2014
  • This paper proposes a single power-conversion ac-dc converter with a dc-link capacitor-less and high power factor. The proposed converter is derived by integrating a full-bridge diode rectifier and a series-resonant active-clamp dc-dc converter. To obtain a high power factor without a power factor correction circuit, this paper proposes a suitable control algorithm for the proposed converter. The proposed converter provides single power-conversion by using the proposed control algorithm for both power factor correction and output control. Also, the active-clamp circuit clamps the surge voltage of switches and recycles the energy stored in the leakage inductance of the transformer. Moreover, it provides zero-voltage turn-on switching of the switches. Also, a series-resonant circuit of the output-voltage doubler removes the reverse-recovery problem of the output diodes. The proposed converter provides maximum power factor of 0.995 and maximum efficiency of 95.1% at the full-load. The operation principle of the converter is analyzed and verified. Experimental results for a 400W ac-dc converter at a constant switching frequency of 50kHz are obtained to show the performance of the proposed converter.

폐광지역에서의 싱크홀 발생 규명을 위한 Active-Passive-Active 유한요소 기법 연구 (Analysis of Sinkhole Formation over Abandoned Mine using Active-Passive-Active Finite Elements)

  • ;신희순;최성웅
    • 터널과지하공간
    • /
    • 제14권6호
    • /
    • pp.411-422
    • /
    • 2004
  • 폐광지역에서 흔히 발생하는 싱크홀 형태의 지반침하는 인근 지역 주민의 안전은 물론, 지상구조물에 심각한 위해 요소로 작용할 수 있다. 본 연구에서는, 이러한 싱크홀의 발생양상을 수치해석적으로 규명하기 위해, 아주 특별한 형태의 유한요소해석을 실시하였다. 특히, 갱도 천반의 붕락에 의해 야기되는 공간이나, 파쇄된 암반이 쌓여서 이루는 폐석더미 등 기존의 수치해석기법으로서는 쉽사리 표현할 수 없었던 현실적인 문제들을 수치적으로 모사하기 위해 active-passive-active 유한요소를 사용하였다. Active 요소 즉 고체 요소는 싱크홀이 형성되는 영역 내에서 인장파괴 기준식을 만족하게 되면 passive 요소 즉 공간 요소로 전환될 수 있다. 싱크홀이 완전히 형성되게 되면 이들 passive요소들은 다시 active요소로 바뀌면서 폐석더미를 수치적으로 모사할 수 있게 된다. 채굴적의 폭, 심도, 천반의 상태 및 붕락 암반의 부피팽창율 등이 싱크홀에 미치는 영향을 검토하기 위해 여러 가지 조건에 의한 유한요소모델이 해석되었다. 본 연구는, 이와 같이 싱크홀이 발생하는 과정이나 천반이 붕락하는 현상 등을 해석하기 위해 수치해석상에서 active-passive-active유한요소들이 효과적으로 사용될 수 있음을 보여준다.