• 제목/요약/키워드: Active Daylighting System

검색결과 6건 처리시간 0.024초

쾌적 빛 환경을 위한 효율적 조명 시스템 (Efficient Lighting System for Amenity Light Environment)

  • 최종효;오명원;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.136-141
    • /
    • 2009
  • Considerable part of energy consumption is occurred by through buildings. Especially, Lighting energy consumption is most part of one in building. There is very various ways and systems for saving lighting energy. In method, It can be divided Passive Daylighting System and Active Daylighting System. Louver, Screen and use of window's character is representative ways of passive system. Reflection mirror, optical pipe and optical fiber is representative method of active system. Introducing day light on which place can't be introduced day light by typical method is important advantage of active system. Except introducing day lighting methods, efficient lighting management system can save lighting energy. It called lighting automation system. Representatively, Occupancy-related automation and Brightness-related automation system is that. According to occupancy and introducing daylighting level properly operate lamp's intensity of illumination that can save lots of energy. Though Introducing daylighting method, effective lighting system we can get proper intensity of illuminance level and energy saving.

  • PDF

추적식 자연채광시스템 현황 및 기술 개발에 관한 연구 (A study on the utilization status and technical development of solar tracking daylighting systems)

  • 김원식;정해준;천원기;한현주;임상훈
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.62-73
    • /
    • 2016
  • 자연채광 시스템은 자연광의 건물 실내 유입을 통한 실내조명에 상당히 효율적으로 적용될 수 있다. 특히, 건물에서 사용되는 에너지 중 28%는 조명에너지에 사용되는 점을 감안하면, 인공조명에의 의존도를 낮출 수 있는 자연채광시스템의 역할은 상당히 중요하다고 할 수 있다. 본 연구에서는 최근 국내에 보급된 다양한 추적식 자연채광시스템(Active Daylighting System)의 특성 및 이용 현황에 대한 조사와 분석을 수행하였다.

조명 소프트웨어를 이용한 추적식 디쉬형 집광기의 배광분포 분석 및 자연채광 성능 예측 (Analysis on Candela Distribution Curve of a Tracking Dish Concentrator and Daylighting Prediction using Lighting Programs)

  • 오승진;한현주;신상웅;천원기
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.457-462
    • /
    • 2012
  • Daylighting software is an important component to predict the performance of daylighting system in advance of a field demonstration study with installing them in buildings. PHOTOPIA is a powerful software to generate a candela distribution curve(CDC) of an active daylighting system like a tracking dish concentrator. With PHOTOPIA, a set of candela distribution curves was generated under clear sky conditions and different solar altitude angles. The candela distribution curves were then imported to RADIANCE for rendering and analysis on the daylighting performance of a tracking dish concentrator when it installed in a actual class room without windows. As a result, the daylight collection efficiency of the dish concentrator was 68.4% when we assumed that there was no tracking error. It was found that candela(cd) and total lumens(lm) increased with solar altitude rising, whereas the distribution angle was fixed. The illuminance uniformity on the work plane in the class room was relatively low, 0.12, while the illuminance uniformity on the area of $2.7m^2$ to which the light was illuminated was considerably high, 0.60. The maximum illuminance was 1,340lux with a solar altitude angle of 80 degrees.

  • PDF

High-Performance Buildings 구현을 위한 신기술 연구 동향 및 에너지 절감 효과 평가 (Review of New Technologies' Energy Conservation Rate in High-Performance Buildings)

  • 김철호;양자강;이승언;유기형;김강수
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.57-65
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze the energy performance by applying new technologies for passive and active control. Method: We selected new technologies for passive and active control which are based on formal study by analyzing technology applied to the High-Performance Buildings in various countries. Also, we analyzed energy saving potential for each technologies by breakdown the result of the energy saving rates in detail. Result: For the wall and roof insulating methods, preceding studies showed that up to 21% energy could be saved by improving roof insulation and applying proper outside insulation compared to non-insulation. For the windows and glazing system, preceding studies showed that Low-E glazing system could save up to 11% energy compared to single glazing system. Studies about solar and daylighting controls revealed that effective daylighting dimming control could save 13% of energy compared to uncontrolled situation. Studies on DOAS (Dedicated Outdoor Air System) showed that about 23% energy could be saved compared to standard VAV system. Studies on the active chilled beam showed that about 25% energy could be saved compared to standard VAV system and studies of applying UFAD (Under Floor Air Distribution) could consume 31% less energy than applying overhead system.

치유환경을 위한 광선반 부착방법에 따른 노인요양시설 침실 내 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 - (A study on Daylighting inducement within bedroom of Elderly care facility by light shelf attaching method for Therapeutic environment - By Dynamic Daylight Simulation Using Weather Data -)

  • 조주영;이기호;윤영일;이효원
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.71-79
    • /
    • 2011
  • There are high recognitions on the importance of comforts in Elderly living environment, but the circumstance is that studies on seniors facility space itself are approached only in planning level, and studies on lighting environment which is significantly associated with the comfort in the indoor environment of seniors where they actually spend the majority of their time are not that active. This study was intended to deduce cozy bedroom environment to which existing elderly care facility can be improved by using light shelf the lighting system with the advantage of being able to serve both as building sun visor and lighting window simultaneously in order to analyze the interior environment of bedroom space of elderly care facility the indoor space where the aged spend the majority of their life and examine the directions for the improvement of existing building lighting system through remodeling and renovation. In this study, lighting performance analysis was done in a way that the windows of the bedroom unit in existing facility were set in southbound direction based on two standard types and were put under initial simulation with the use of Autodesk Revit 2011, and after the simulation results were converted to Green Building Studio gbXML file to be used in ECOTECT, Daylight Autonomy a dynamic simulation and static natural lighting simulation the existing method of calculating daylight factors were deduced through Ecotect Analysis 2011. In conclusion, exiting standard model was found in such a condition that the daylight factors for both type A and type B were above 5% the proper standard value, and required improvement. In case light shelf the natural lighting system was attached, the daylight factor was improved to proper standard value for type A, and also was improved above existing facility for type B.

거울형 태양광 채광시스템의 실제 건축물 적용에 따른 실내주광조도 평가 (Indoor Illuminance Evaluation on a Mirror Sunlighting System Applied to the Apartments under Real Sky Condition)

  • 정주희;김정태
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.137-145
    • /
    • 2010
  • Active sunlighting systems have been applied to deliver sunlight into the indoor space where natural light is insufficient, mainly because of the congested high-rise buildings in urban areas. Among various active sunlighting systems, a mirror sunlighting system which is simple structure and economically reasonable has been widely used in different types of spaces such as underground, north facing place and atrium. This study was to evaluate the mirror sunlighting systems, which were consisted of the first mirror of $3.5m{\times}2.5m$, the eight sets of the second mirrors of $1.0m{\times}1.25m$ and a sun tracker. Ten sets of the systems were installed for 40 apartment living rooms, the configuration of $3.5m(W){\times}4.0m(D){\times}2.5m(H)$ where sunlighting were not possible due to high retaining walls located in the front of the living rooms. The 45 HOBO data logger sensors for the indoor illuminance were equipped and 2 Li-cor photometers for outdoor illuminance. Both indoor and outdoor horizontal illuminances were monitored every second from 9am to 3pm on 17 January 2010 under clear sky condition. The results showed that the indoor illuminance of installed mirror sunlighting system was significant relationship with outdoor illuminance and increased the indoor illuminance level by 4.2 times on the whole floor space, by 8 times on the sun patch space of 6m2 and even by 2 times on the no sun patch space. In addition, the luminous conditions of the living room under real sky conditions met the KS recommendation for difficult task (600-1000-1500 lux) such as sewing and reading on whole floor space and sun patch space. It was proved that the benefits of mirror sunlighting systems included an effective technology for penetrating daylight into indoors where sunlighting was not possible and improving occupants' satisfaction and health, and contributing to energy saving in apartments during daytime.