• Title/Summary/Keyword: Action limit

Search Result 198, Processing Time 0.03 seconds

A study on changes in HRM by introduction Balanced Scorecard(BSC) in the public sector (공공부문에서의 BSC 도입에 따른 인사관리의 변화)

  • Lim, Hyo-Chang
    • Korean Business Review
    • /
    • v.18 no.2
    • /
    • pp.83-110
    • /
    • 2005
  • To comprehend the present state of performance evaluation and management systems and their problems, we examined performance evaluation and management systems that have been used in the public sector and figured out their limits and problems in practical use and then, we searched, from academic basis, for ways to solve those problems and complement the limits. Especially, we focused on developing practical solutions that can be applied to a budget and human resource effectively. We expect this research will provide to public sector a comprehensive foundation for understanding the core concept of myriad theories of performance management in public sector including "Balanced Scorecard" and for finding out the limits and problems of each theories, then it can prepare the alternatives in advance. But the research is restricted within the general guideline for performance management. It doesn't provide practical and detailed action programs that are needed for actual execution. So, further studies on particular action programs are needed to compliment this limit and for coming to stay of performance management system in the public sector quickly, the enactment of performance management is needed as well.

  • PDF

Inhalation Sedation with Nitrous Oxide in Dental Treatment (Nitrous Oxide를 이용한 흡입진정)

  • Yoon, Byung-Bae
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.2 no.1 s.2
    • /
    • pp.1-6
    • /
    • 2002
  • The usage of nitrous oxide is increased for the anxious patient to dental treatment. There are two methods to induce the sedation during dental treatment. One is sedation with drugs the other no need of drugs. We discussed here about sedation with drugs. The methods of drug administration are oral, intramuscular, intravenous, inhalation. The method of oral administration of drugs are convenient to patient and doctor but poor controllability. Intramuscular method is a parenteral technique that maintains several advantages over the enteral technique. However its pales in comparison to other parenteral technique. Intravenous method represents most effective method of ensuring predictable and adequate sedation in all patients. But it has inability to reverse the action of drugs after they have been injected except some drugs (e.g., narcotics and benzodiazepine). A variety of gaseous agents may be administered by inhalation to produce sedation. In dental practice, the inhalation administration of gas means use of nitrous oxide. There are many advantages of nitrous oxide administration. First, very short latent period and rapid onset of drug action which lead to possible titration of drug concentration. With nitrous oxide, clinical effects may become noticeable as quickly as 15 to 30 seconds after inhalation. Recovery from inhalation sedation is also quite rapid. In out patient dental practice rapid recovery is very important because it permit to discharge the patient without escort and the patient return to their ordinary life without limit. To success the conscious sedation with nitrous oxide, the administrator should be keep the mind that always titration of nitrous oxide concentration during induction and treatment. Careful observation need during treatment to prevent oversedation because the adequate nitrous oxide concentration to patients changed by environmental stress. Always begins with 100% oxygen and ends with 100% oxygen to prevent diffusion hypoxia which rare in clinical practice.

  • PDF

Experimental Study on Structural Behavior of Interfaces of Double Composite Girder Using the 80 MPa Concrete (80 MPa급 콘크리트를 활용한 이중합성 거더의 수평접합면 구조거동에 관한 실험적 연구)

  • Yang, In-Wook;Lim, Eol;Ha, Tae-Yul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.400-413
    • /
    • 2016
  • The horizontal shear capacity when the flange of a steel girder is replaced with 80 MPa concrete is important for its structural safety. In this study, 6 specimens with different interface conditions were designed and fabricated based on the Limit State Design Code on Korean Highway Bridges and static tests were performed to measure the horizontal shear capacity. Not only the resistance factors of the stud shear connector, concrete and reinforcement, but also the surface conditions of the casing concrete and spacing of the horizontal shear reinforcements were used as the experimental variables. The experiments showed that the interfaces between the steel girder and the concrete flange have stronger joint performance than those between the concrete flange and deck slab. To ensure the composite action in the plastic zone, the conservative horizontal shear reinforcement is more important than the roughness in the concrete face.

U-Healthcare user's privacy protection protocol with Implantable medical Device of State Information (상태정보에 따른 체내삽입형 장치를 부착한 유-헬스케어 환자의 프라이버시 보호 프로토콜)

  • Jeong, Yoon-Su;Lee, Sang-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.297-306
    • /
    • 2012
  • IT technology of U-healthcare system is being grafted onto medical services and the use of U-healthcare system are extending steadily. However, in case of patients using Implantable Medical Device (IMD) in U-healthcare system, patients' privacy protection and safe access to system recently has emerged as a major issue. This paper proposes a patients' privacy protection protocol to prevent any illegal accesses from third parties as state value and action value are synchronized after patients' information virtualization. The proposed protocol can limit the access range of patients' information according to authentication information of hospitals, doctors, nurses, and pharmacies registered in the U-healthcare server. Additionally, this protocol can increase management efficiency for patients' privacy by synchronizing state values and action values only for approved information and, by instituting this process, third parties cannot easily access patients' information.

Strengthening of steel-concrete composite beams with composite slab

  • Subhani, Mahbube;Kabir, Muhammad Ikramul;Al-Amer, Riyadh
    • Steel and Composite Structures
    • /
    • v.34 no.1
    • /
    • pp.91-105
    • /
    • 2020
  • Steel-concrete composite beam with profiled steel sheet has gained its popularity in the last two decades. Due to the ageing of these structures, retrofitting in terms of flexural strength is necessary to ensure that the aged structures can carry the increased traffic load throughout their design life. The steel ribs, which presented in the profiled steel deck, limit the use of shear connectors. This leads to a poor degree of composite action between the concrete slab and steel beam compared to the solid slab situation. As a result, the shear connectors that connects the slab and beam will be subjected to higher shear stress which may also require strengthening to increase the load carrying capacity of an existing composite structure. While most of the available studies focus on the strengthening of longitudinal shear and flexural strength separately, the present work investigates the effect of both flexural and longitudinal shear strengthening of steel-concrete composite beam with composite slab in terms of failure modes, ultimate load carrying capacity, ductility, end-slip, strain profile and interface differential strain. The flexural strengthening was conducted using carbon fibre reinforced polymer (CFRP) or steel plate on the soffit of the steel I-beam, while longitudinal shear capacity was enhanced using post-installed high strength bolts. Moreover, a combination of both the longitudinal shear and flexural strengthening techniques was also implemented (hybrid strengthening). It is concluded that hybrid strengthening improved the ultimate load carrying capacity and reduce slip and interface differential strain that lead to improved composite action. However, hybrid strengthening resulted in brittle failure mode that decreased ductility of the beam.

Antifungal Actions of Crude Drug Water Extracts on Candida albicans(I) (Candida albicans에 대한 생약의 항진균성에 관한 연구(I))

  • Yoo, Seung-Cho;Suh, Jung-Sik
    • Korean Journal of Pharmacognosy
    • /
    • v.5 no.3
    • /
    • pp.147-154
    • /
    • 1974
  • Some crude drugs in ancient literatures have been used as traditional therapeutic agent of leucorrhea mainly caused by Trichomonas vaginalis and Candida albicans. Sixty six kinds of crude drugs in ancient literatures and ten constituents were selected as sample drugs. Trichomycin standard was tested to compare with the above drugs. To determine the anti-fungal effect of these drugs on Candida albicans Yu 1200, a test organism, screening test was conducted. Antifungal activities of crude drug water extracts were observed by means of two test methods : firstly through the agar slant method and secondly the counting chamber method which was used for acknowledged drug agents upon the result of the agar slant method. And in order to improve the fungicidal effect, the organisms were stained with 0.02% methylene blue solution. The results of the above test indicated that Fritillariae Rhizoma has antifungal action in the concentration of 310mcg/ml, Coptidis Rhizoma in 620mcg/ml, Meliae Cortex, Scutellariae Radix both in 5,000mcg/ml. Baicalin, catechol among the pure isolated constituents inhibited in the range of 50mcg/ml. This score was based on 50% inhibition in comparison with amounts of control organisms. Rhei Rhizoma, Mori Radicis Cortex, Linderae Radix, and Amomi globosi Fructus showed the antifungal effect moderately in 5,000mcg/ml, and baicalein and pectolinarin in 50mcg/ml in the limit of between 35% and 50% antifungal activity. Staining with 0.02% methylene blue showed that any of the crude drug extracts was unable to stain the cells, but trichomycin in 0.86unit/ml able to stain 12% of the cells. This result means that crude drugs probably do not have fungicidal but fungistatic action.

  • PDF

The Study of the Cycle Time Improvement by Work-In-Process Statistical Process Control Method for IC Foundry Manufacturing

  • Lin, Yu-Cheng;Tsai, Chih-Hung;Li, Rong-Kwei;Chen, Ching-Piao;Chen, Hsien-Ching
    • International Journal of Quality Innovation
    • /
    • v.9 no.3
    • /
    • pp.71-91
    • /
    • 2008
  • The definition of cycle time is the time from the wafer start to the wafer output. It usually takes one or two months to get the product since customer decides to produce it. The cycle time is a critical factor for customer satisfaction because it represents the response time to the market. Long cycle time reflects the ineffective investment for the capital. The cycle time is very important for foundry because long cycle time will cause customer unsatisfied and the order loss. Consequently, all of the foundries put lots of human source in the cycle time improvement. Usually, we make decisions based on the experience in the cycle time management. We have no mechanism or theory for cycle time management. We do work-in-process (WIP) management based on turn rate and standard WIP (STD WIP) set by experiences. But the experience didn't mean the optimal solution, when the situation changed, the cycle time or the standard WIP will also be changed. The experience will not always be applicable. If we only have the experience and no mechanism, management will not be work out. After interview several foundry fab managers, all of the fab can't reflect the situation. That is, all of them will have an impact period after product mix or utilization varied. In this study, we want to develop a formula for standard WIP and use statistical process control (SPC) concept to set WIP upper/lower limit level. When WIP exceed the limit level, it will trigger action plans to compensate WIP Profile. If WIP Profile balances, we don't need too much WIP. So WIP level could be reduced and cycle time also could be reduced.

Development of Membrane Strip Assay System for Lipoprotein Cholesterol Based on Liquid-Phase Enzyme Reactions (액상 효소반응을 이용한 Membrane Strip 형 Cholesterol 측정시스템의 개발)

  • 신인수;목락선;장미라;백세환
    • KSBB Journal
    • /
    • v.13 no.5
    • /
    • pp.577-584
    • /
    • 1998
  • A sensitive membrane strip assay for plasma lipoprotein cholesterol that can be performed without handling reagents has been investigated. We previously developed an assay system with immobilized enzymes (cholesterol esterase and cholesterol oxidase) on the surfaces of nitrocellulose membrane(1). In such a case, the amount of enzymes present on the membrane was limited by its surface area and, thus, the detection capability was relatively poor (> 50 mg/dL cholesterol). To overcome this problem, we devised a new system with non-immobilized enzymes by placing them within interstitial spaces of a celullose membrane pad in a dry state. Upon contact with sample medium, the enzymes were immediately dissolved and participated in the reactions with cholesterol in a liquid phase. We constructed a user-friendly system consisting of four membrane pads fro sample application, cholesterol decomposition, color development as signal, and medium absorption to invoke a continuous flow (sequential location from the bottom). A sample containing lipoproteins was added into the application pad by capillary action and transferred to the next pad for decomposition. The decomposition pad (namely, enzyme pad) contained a detergent (sodium cholate) for the destruction of lipoprotein particles, the two enzymes for cholesterol decomposition, and a chromogen (3,3'-diaminobenzidine). As a consequence of the enzyme reactions, hydrogen peroxide was produced, and then reacted in the presence of the chromogen with horseradish peroxidase immobilized on the signal generation pad. Finally, a colorimetric signal directly proportional to the cholesterol concentration was produced. The detection limit determined from this system under optimal conditions was at least 2 times lower than of the enzyme-immobilized system.

  • PDF

A Study on Expression for Indoor Design base of Interactive using Digital Art (디지털 아트를 활용한 인터랙티브 기반의 실내공간디자인 표현 연구)

  • Kim, Jae-Heon;Kim, Chee-Yong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2473-2478
    • /
    • 2009
  • The latest, Digital art is attempt new field's Art, that is utilize variously digital media image, sound, simulation, 3D holography. A large number of Digital Art is contact with the audience in pavilion(limit place and limit period). However, It will be possible, Digital Art can use place digital form media even there are indoor, outdoor, anywhere. Prior to study, I was to analyze the feature of Digital Art in order to using Digital Art, Interactivity make communication between humans and the art as well as cause audience participation, and take a role of bridge between human and space. A study was base on the relationship between human and space, space and Digital Art, Digital Art and human taken the focus interaction between human and space, and Interactivity of Digital Art. This paper analyze reciprocal action for utilize Digital Art in indoor space design, and this paper study expression about indoor design base of interactive.

The Integrity Verification of Tube-end Sleeve by ECT (와전류탐상검사에 의한 튜브엔드 슬리브 건전성 검증)

  • Kim, Su Jin;Kwon, Kyung Joo;Suk, Dong Hwa;Park, Ki Tae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.20-24
    • /
    • 2015
  • Steam generator(S/G) tubes in pressurized water reactor (PWR's) are subject to several types of degradation. This degradation includes denting, pitting, intergranular attack(IGA), intergranular stress corrosion cracking(IGSCC), fatigue, fretting and wear. Degradation can be derived from either the primary side(inside) or the secondary side(outside) of the tube. Recent issue for tube degradation in domestic steam generator is the tube end cracking on seal weld region. The seal weld region at the tube end and tube itself is regarded as a pressure boundary between the primary side and the secondary side. One of the Westinghouse Model-F S/G has experienced tube end cracking and its number of plugging approximately becomes to the operating limit up to 5% due to tube end cracking which was reported as SAI/MAI(single/multiple axial indication) or SCI/MCI(Single/multiple circumferential indication) from the results of eddy current testing. Eddy current mock-up test was carried out to determine the origin of cracking whether it is from weld zone area or parent tube. This result was helpful to analyze crack location on ECT data. Correct action on this problem was the installation of tube-end sleeve. Last year, after removing 340 installed plugs from tubes, selected 269 tubes took tube-end sleeve installation. Tube-end sleeve brought pressure boundary from parent tube to installed sleeve tube. Tube-end sleeve has the benefit of reducing outage period and increasing more revenue than replacing S/G. This paper is provided to assist interest parties in effectively understanding this issue.