• 제목/요약/키워드: Acrylic material

검색결과 340건 처리시간 0.028초

임플랜트 지지 상부구조물에서 나사조임순서와 조임방법이 풀림토크값에 미치는 영향 (THE EFFECT OF SCREW TIGHTENING SEQUENCE AND TIGHTENING METHOD ON THE DETORQUE VALUE IN IMPLANT-SUPPORTED SUPERSTRUCTURE)

  • 최정한;김창회;임영준;김명주;이석형
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.653-664
    • /
    • 2007
  • Statement of problem: The screw detorque value is a measure of the preload remaining in the screw just before detorquing. Purpose: This study evaluated the effect of different screw tightening sequences and tightening methods on detorque values for a well-fitting implant superstructure. Material and method: An implant superstructure that connected directly to four implants (Astra Tech) was fabricated on a fully edentulous mandibular acrylic resin model. Six well-fitting dental stone casts were made with a pickup impression of the superstructure from the acrylic resin model. To evaluate the effect of three screw tightening sequences (1-2-3-4, 2-4-3-1, and 2-3-1-4) and two tightening methods (2-step and 1-step) on the stability of screw joint, the detorque values for a well-fitting implant superstructure were measured twice after screw tightening using 20 Ncm. Detorque values were analyzed using multi-way analysis of variance and two-way analysis of variance at a .05 level of significance. Results: 1. The mean detorque values for three screw tightening sequences were 12.3 Ncm, 12.6 Ncm, and 12.0 Ncm, respectively. 2. The mean detorque values for two screw tightening methods were 12.0 Ncm, and 12.2 Ncm, respectively. 3. The mean of mimimum detorque values for three screw tightening sequences and for two tightening methods were 10.6 Ncm, 11.1 Ncm, 10.5 Ncm, and 9.8 Ncm, respectively. 4. No statistically significant differences among the variables of screw tightening sequence and tightening method were found (p>.05) for detorque values and for mimimum detorque values. Conclusion: Within the limitations of this study, the screw tightening sequence and tightening method did not have a significant effect on the detorque values for a well-fitting implant superstructure.

알킬 아크릴레이트계의 다중 Core-shell 복합입자의 제조 (Manufacture of Alkyl Acrylate Multi Core-shell Composite Particle)

  • 조대훈;최성일;고현미;설수덕
    • 접착 및 계면
    • /
    • 제12권1호
    • /
    • pp.16-25
    • /
    • 2011
  • Core 입자로 methyl methacrylate (MMA), n-butyl methacrylate (BMA)를 하고 shell 입자로 MMA, BMA, stylene (St), 2-hydroxylethylmethacrylate (2-HEMA), acrylic acid (AA)를 각각 사용하여 개시제 aommonium persulfate (APS), 유화제로 sodium dodecyl benzene sulfonate (SDBS)의 농도(0.01~0.03 wt%), 단량체의 종류와 조성을 변화시켜 수용성 유화중합으로 다중 core-shell 복합입자를 제조하여 전화율, 입자경 및 입도 분포, 평균 분자량, 분자구조, 유리전이온도, 입자의 형태 및 인장강도와 신율을 각각 측정하여 다음과 같은 결론을 얻었다. SDBS 농도 0.02 wt%에서 MMA core-(BMA/St/AA) shell 복합인자가 전화율이 98%로 우수하였고, 입자 직경은 SDBS 농도 0.03 wt%에서 BMA core-(MMA/St/AA) shell의 복합입자가 $0.47{\mu}m$로 높게 나왔다. 유리전이온도 측정은 단일 core-shell 복합입자의 2군데에 비하여 다중 core-shell 복합입자는 3군데가 존재하여 shell단량체 내의 단량체의 종류와 조성에 따라 유리전이온도 조절도 가능하고 동시에 접착력이 향상된 접착소재로서 부직포 섬유 결속제로 사용될 수 있었다.

폴리에스터계 동적가교물의 고무함량 및 고무종류에 따른 물성 (Polyether Ester by Rubber Content and Rubber According to the Type of Dynamic Vulcanized Properties (TPEE))

  • 윤주호;윤정환;하성문;김일;심상은
    • Elastomers and Composites
    • /
    • 제48권1호
    • /
    • pp.67-75
    • /
    • 2013
  • E-TPE(Engineering Thermoplastic Polyether Ester)는 Ester 관능기를 갖는 Elastomer 소재로서 리사이클이 가능하며 빠른 가공성을 지닌다. 또한 경량성이 뛰어나 자동차의 경우 연비향상에 도움을 주는 친환경 소재로 부각되고 있다. 고무와 엔지니어링 플라스틱의 특성을 모두 가지고 있는 E-TPE는 사용 가능한 온도영역이 넓고, 내열성 및 내유성이 우수하여 자동차 부품소재분나 전기전자분야의 신소재로 주목받고 있으나 국내에서는 원천기술이 부족하여 전량 수입에 의존하고 있는 실정이므로 연구개발이 시급하다. 본 연구에서는 하드 세그먼트로 폴리에스터계(TPEE)를 base로 하여 소프트 세그먼트로 Ethylen-prophylene-Copolymer와 CSM(Choloro sulphonated polyethylene Rubber), VAMAC(Ethylene Acrylic Rubber), NBR(Acrylonitrin Butadiene Rubber)의 탄성체를 1,3-Phenylene-bisoxazoline 가교제로 동적가교 시켜 함량과 첨가된 고무에 따른 물성을 관찰하였다. 그 결과 NBR 첨가된 동적가교물의 물성이 다른 고무에 비해 내열성 및 내유성 향상에 되었음을 확인하였다.

수종의 영구 탄성 이장재와 의치상용 레진간의 인장 결합 강도 (COMPARISON ON TENSILE BOND STRENGTH OF PERMANENT SOFT DENTURE LINERS BONDED TO THE DENTURE BASE RESIN)

  • 김래규;정문규;임순호
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.200-211
    • /
    • 1999
  • For many years permanent soft denture liners has been widely used in dental practice directly or indirectly because of its function in absorbing and distributing the impact force. However, it reveals problems such as lack of permanency and decreased bond strength in long term use. The purpose of this study is to measure the bond strength and failure between denture base resin and several permanent liners. Lucitone 199 was used as denture base resin with soft acrylic liners (Triad, Tokuso Rebase) and silicone elastomers (Tokuyama, Ufi Gel C) bonded to measure the tensile strength before and after thermocycling. The thermocycling was done in 2000 cycles at $5^{\circ}C,\;26^{\circ}C\;and\;55^{\circ}C$ and the measured tensile strength values before and after thermocycling were compared. The mode of failure was investigated in the separated specimens. The results are as follows. 1. As to tensile strength, the strongest material is Tokuso Rebase followed by Triad, Tokuyama, Ufi Gel C in before thermocycling and the order of Triad, Tokuso Rebase, Tokuyama, Ufi Gel C in after thermocycling state. There was significant difference between the values of Triad, Tokuso Rebase and Tokuyama, Ufi Gel C(p<0.05). 2. As to degree of displacement, Ufi Gel C showed most displacement with or without thermo-cycling treatment and also the difference was significant with the other materials(p<0.05). 3. As to comparisons before and after thermocycling, Tokuso Rebase and Tokuyama showed significant difference in bond strength, whereas Triad and Tokuso Rebase showed significant difference in the degree of displacement(p<0.05). 4. In debonded specimens, Triad and Ufi Gel C showed adhesion failure and Tokuyama showed cohesion failure. Both failures were observed in Tokuso Rebase with adhesion failure up to 70%. The results of this study showed that degree of bond strength between permanent soft denture liner and denture base resin were variable. There was a significant difference between soft acrylics and silicone elastomers with regard to bond strength. Further research in improving bond strength of widely used silicone elastomers and in developing the method of measuring bond strength between denture base resin and the lining materials is needed.

  • PDF

치주지지가 감소된 상태에서 섬유강화형 포스트로 수복한 치아의 실패양상 분석 (AN ANALYSIS OF FAILURE MODE OF TEETH RESTORED WITH FIBER-REINFORCED POSTS UNDER THE CONDITION OF BONY RESORPTION)

  • 이병우;이양진;조리라;박찬진
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.232-242
    • /
    • 2003
  • Statement of problem : Fiber-reinforced posts have lower modulus of elasticity than titanium post or cast post-core. With this similar elasticity to that of dentin, fiber-reinforced posts have been known to have a tendency to reduce the risk of root fracture. However, there were few studies on the teeth restored with fiber-reinforced posts under the condition of reduced periodontal support. Purpose : The purpose of this study was to evaluate the fracture strength and failure mode of endodontically treated teeth restored with fiber-reinforced posts and titanium posts under the condition of reduced periodontal support. Material and method : Extracted human maxillary incisor roots were divided into 3 groups (group 1 carbon fiber post, group 2 : glass fiber post, and group 3 : titanium alloy post). After coronectomy and endodontic treatment, teeth were restored with each post systems and resin core according to the manufacturer's recommendation. Then, teeth with simulated periodontal ligament were embedded in the acrylic resin blocks at the level of 4 mm below the cemento-enamel junction. Each specimen was exposed to $10^5$ load cycles with average 30 N force in $36.5^{\circ}C$ water using a computer-controlled chewing simulator. Loads were applied at $45^{\circ}$ angle to the long axis of the teeth. After cyclic loading, teeth were subjected a compressive load until failure at a crosshead speed of 0.5 mm/min. Fracture strength (N) and failure mode were examined. The fracture strength was analyzed with one-way ANOVA and the Scheffe adjustment at the 95% significance level. Results and conclusion : The results were as follows. 1. There was no statistically significant difference in the mean fracture strength among the groups (P<.05). 2. Carbon fiber post and glass fiber post group showed less root fracture tendency than control group. 3. All specimens with root fractures showed fracture lines above the level of acrylic resin block, except for only one specimen in group 3.

PVC 바닥상재용 광경화형 하드 코팅액의 제조 및 응용에 관한 연구 (Formulation and Application of UV-Cured Hard Coating Compounds for PVC Tile)

  • 박보람;윤현정;조홍;하진욱
    • 한국산학기술학회논문지
    • /
    • 제10권9호
    • /
    • pp.2396-2401
    • /
    • 2009
  • 본 연구는 건축자재로 널리 사용되는 PVC 바닥상재의 표면을 스크래치로부터 보호하기 위하여 기존에 사용하는 광경화형 우레탄-아크릴 수지에 내마모성을 향상시킨 광경화형 하드 코팅액 개발에 관한 것이다. PVC 바닥상재용으로 사용되는 내마모성이 없는 우레탄-아크릴 수지에 $Al_2O_3$(Al-160SG-3), $Al(OH)_3$(SH-8W) 및 $SiO_2$(KS-5000) 등 서로 다른 내마모성을 지닌 물질을 분말 형태로 수지의 양 대비 함량(wt%)을 $10{\sim}30%$로 변화하여 첨가한 후 링밀(Ring Mill)을 사용, 배합하여 수지의 내마모성을 향상시킨 하드 코팅액을 제조하였다. 제조한 하드 코팅액은 코팅층의 두께조절이 가능한 코팅(Bar-coating)을 사용하여 PVC 바닥상재에 코팅 한 후 내마모성, 연필경도, 부착력, 코팅두께 등의 코팅층 표면물성을 평가하였다. 연구결과, 수지에 $Al_2O_3$ 분말 30%를 혼합하여 제조한 하드 코팅액이 내마모성 1등급, 연필경도 H, 부착력 100%로 가장 좋은 물성을 보였으며, 전반적으로 입자크기가 작고, 분말 함량이 많을수록 또한 코팅두께가 두꺼워 질수록 경도 및 내마모성이 우수한 것으로 나타났다.

실란기가 도입된 폴리우레탄 아크릴레이트 합성 및 자외선 경화 특성 분석 (Synthesis of Silane Group Modified Polyurethane Acrylate and Analysis of Its UV-curing Property)

  • 김정수
    • 접착 및 계면
    • /
    • 제22권3호
    • /
    • pp.98-105
    • /
    • 2021
  • 본 연구에서는 실란기가 도입된 UV 경화형 우레탄 아크릴레이트를 사용하여 투명성 및 접착성/이형성을 갖춘 silver nanoparticle 전사용 접착 조성물을 제조하였다. Silver nanoparticle이 PET 위에 패터닝되어 있는 Ag/PET 필름과 전사 대상인 PC필름 사이에 제조한 접착 조성물을 도포하고 UV로 광경화한 후, PET를 제거하여 Ag/PC 필름을 제조하였다. 실란기가 도입된 UV 경화형 우레탄 아크릴레이트는 polycaprolactone diol (PCL)과 isophrone diisocyanate (IPDI), 2-hydroxyethyl methacrylate (HEMA), (3-aminopropyl)triethoxysilane (APTES)를 사용하여 합성하였다. APTES의 실란기는 특수 처리된 Ag표면과 반응하여 계면접착력이 개선될 수 있으며, 실란기가 도입된 우레탄 아크릴레이트와 희석제로 투입하는 기능성 아크릴 희석제에 의하여 PC필름과의 접착력을 향상시켰다. 우레탄 아크릴레이트 합성은 FT-IR을 이용하여 분석하였으며, APTES의 몰비와 아크릴 희석제 조성에 따라, 접착 특성과 광학 특성, 전사 특성 등을 비교하였다. 결과적으로, PUA2S1_0.5의 조건으로 제조된 접착 조성물에서 가장 우수한 전사 특성을 확인하였다.

선박 거주성 향상을 위한 선실 소음 저감 시스템 개발에 관한 실험적 연구 (An Experimental Study on the Development of a Cabin Noise Reduction System for Improving Ship Habitability)

  • 서영철;김득봉;김철승
    • 해양환경안전학회지
    • /
    • 제29권6호
    • /
    • pp.620-627
    • /
    • 2023
  • 선내 소음은 선원의 거주성과 건강을 위한 중요한 요소 중의 하나로, 선내 소음을 줄이기 위한 노력이 활발하게 진행되고 있다. 소음 저감 방법에는 수동소음제어(PNC) 방법과 능동소음제어(ANC) 방법이 있다. 자동차, 항공기와 달리 선박에서는 ANC를 이용한 소음 저감 대책이 미미한 실정이다. 본 연구는 능동소음제어(ANC)와 같이 방음판과 고주파진동원을 이용하여 기관실에 발생한 소음을 줄이고자 하였다. 이를 위해 아크릴 상자를 이용하여 실험 모형을 만들었고, 4가지 조건별로 소음 저감 효과를 측정하였다. 실험 결과는 다음과 같다. 첫째, 방음판은 55 dB ~ 85 dB까지 모든 범위에서 소음 저감 효과가 있었다. 고주파진동원은 낮은 소음에서 효과가 없었으나, 70.8 dB(A)과 85 dB(A)와 같은 높은 소음에서는 효과가 있었다. 둘째, 방음판과 고주파진동원을 동시에 사용하는 경우에는 최대 -2.2 dB(A) 만큼의 소음 저감 효과가 있었다. 본 실험의 결과는 아크릴판으로 제작한 실험모형에서 얻은 결과로 철판으로 된 실제 선박과 다를 수 있다. 추후 연구에서 실제 선박에서 사용하는 철판(재질과 두께, 구조를 고려)을 이용하여 실험하고자 한다. 이 연구가 선박에 승선하는 선원들의 거주성 향상과 건강 증진에 도움이 되기를 기대한다.

초본류 문화재의 보존처리를 위한 연구 -부여 궁남지 출토 짚신을 대상으로- (A study for conservation of plant-based cultural properties : on the subject of straw sandals excavated at Goongnamji in Buyeo)

  • 나미선;김익주;김수기
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 한국문화재보존과학회 2004년도 제20회 발표논문집
    • /
    • pp.115-130
    • /
    • 2004
  • Plant-based cultural assets using straw and grass as household goods of our people's have been used as indispensable tools for practical living for a very long time. However, only a limited number of artifacts were unearthed so far due to tile fragility of the material. For this reason, research on plant-based cultural properties had close to no progress, and the appropriateness of the PEG method, high-grade alcohol method, alcohol--ether-resin method, and Paraloid B-72 used in preserving plant-based cultural properties has not been sufficiently investigated. Therefore, this study examined the weight change rate by applying the methods of Primal MC-76 and vacuum freeze-drying used mostly as a earth-layer hardening material among PEG and acrylic resin, which are applied widely for preservation of waterlogged archaeological wood, as a means to preserve plant-based cultural properties along with the examination of the subject material, and an experiment was also performed on moisture absorption. The findings as a result were, first, the plant-based material being studied was found to be Typha (Typha orientalis Presl). Secondly, the weight change experiment applying $PEG\#400$ and $PEG\#4000$ confirmed a steady increase of weight if PEG -2Step is used for treatment. Third, in preserving all subject materials with soil, treatment with $PEG\#4000$, Primal MC-76, and vacuum freeze-drying showed that tile vacuum freeze-drying method resulted in the largest or $20\%$ reduction in weight, while Primal MC-76 resulted in $18\%$ and $PEG\#4000$ in $8\%$ of weight reduction. It was concluded that, considering the stability of soil measurement, this came to be because resin permeation was carried out along with tile drying process. Fourth, the weight changes were found to be around $10\%$ in various humidity conditions after the preservation treatment. The greatest weight change rate was seen in the case of $PEG\#4000$, particularly having chemicals gush out in a high humidity (RH $84\%$ or higher) environment. In the case of Primal MC-76 and vacuum freeze-drying methods, $6\~8\%$ weight changes were detected, and the lowest weight change was found in the case of the vacuum freeze-drying method. Fifth, as for color changes after treatment, blackening occurred most strongly with $PEG\#4000$, while Primal MC-76 and vacuum freeze-drying manifested colors closest to dry straw or grass. However, the texture of straw was not very evident in the case of Primal MC-76, due to a glossy surface, but vacuum freeze-drying was found to offer tile best result in terms of texture. Putting together the results of the above experiments, vacuum freeze-drying presented after being treated with PEG2-Step the most stabilized changes in weight, while it offered the smallest change in color as well.

  • PDF

할로겐과 카르복시산으로 치환된 피리딘 첨가제를 사용한 소프트 콘택트렌즈의 물성 평가 (Physical Properties Assessment of Soft Contact Lens with Halogen and Carboxylic Substituted Pyridine as Additive)

  • 김득현;성아영
    • 한국안광학회지
    • /
    • 제20권4호
    • /
    • pp.437-443
    • /
    • 2015
  • 목적: 본 연구는 3-chloropyridine-4-carboxylic acid와 3-fluoropyridine-4-carboxylic acid를 첨가제로 사용하여 소프트 콘택트렌즈 제조 후 물리적 및 광학성 특성을 분석하여 콘택트렌즈 재료로서 활용도를 알아보았다. 방법: 본 실험에서는 소프트 하이드로젤 콘택트렌즈의 주재료인 HEMA (2-hydroxyethyl methacrylate)와 AA(acylic acid), MMA(methacrylic acid) 그리고 개시제인 AIBN(azobisisobutyronitrile), 교차결합제인 EGDMA(ethylene glycol dimethacrylate)를 사용하여 공중합 하였다. 결과: 생성된 고분자의 물리적 특성을 측정한 결과, 굴절률 1.4320~1.4342, 함수율 34.54~37.15%, 접촉각 $57.82{\sim}79.57^{\circ}$, 인장강도 0.2872~0.3608로 각각 나타났고 광학적 특성 측정 결과 가시광선 영역에서는 투과율이 88.8~90.6%로 나타났으며, UV-B 76.8~82.4%, UV-A 84.6~86.6%로 각각 나타났다. 결론: 본 실험 결과 3-chloropyridine-4-carboxylic acid 및 3-fluoropyridine-4-carboxylic acid를 첨가제로 사용하였을 때 고습윤성 및 자외선 차단기능을 가진 콘택트렌즈 재료로 활용될 수 있을 것으로 판단된다.