• 제목/요약/키워드: Acoustic transmission

검색결과 551건 처리시간 0.026초

로터리 압축기 내부의 소음해석 (Acoustic Analysis of the Cavity in Rotary Compressor)

  • 정의봉;김봉준;김재호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권2호
    • /
    • pp.97-103
    • /
    • 2000
  • Gas pulsation discharged from the cylinder causes noise in the rotary compressor. Mufflers are usually used to reduce the noise generated by the gas pulsation. The muffler has been designed to maximize the acoustic transmission loss of the muffler. The gas which went through muffler is discharged to the cavity in compressor. Thus, the acoustic characteristics of cavity should be taken into account in muffler design. In this paper, the program for the acoustic substructure synthesis method is developed. This program can be interfaced with SYSNOISE which is commercial acoustic package. Several types of mufflers designed to have the better acoustic performance are suggested in this work and compared with the existing commerical muffler in the compressor. The acoustic performance of mufflers taking into consideration of the cavity in the compressor is also carried out by the developed program.

  • PDF

동해 내부파의 물리적 특성과 단주기 오목형 내부파가 음파전달에 미치는 영향 (Physical Characteristics of Internal Waves and the Effect of Short Depression Internal Wave on Acoustic Transmission in the East Sea)

  • 한봉완;임세한;박경주;김성일
    • 한국군사과학기술학회지
    • /
    • 제12권1호
    • /
    • pp.37-43
    • /
    • 2009
  • Fluctuations in the ocean are closely related with the underwater acoustic propagation. Internal waves are generated by fluctuation of isopycnal layer in the upper part of the stratified ocean, which are propagated from offshore to coastal area. Physical characteristics of the internal waves existed in the East Sea were derived from the five field experimental data and the ocean monitoring buoy nearshore the mid-east coast of Korea. The dominant periods are appeared in the near-inertial period about $17{\sim}20hours$ and the short period about a few minutes. The wavelengths of them are $10{\sim}50km$ and $300{\sim}1000m$, and the phase speeds are $20{\sim}100cm/s$ and $30{\sim}70cm/s$, respectively The maximum amplitudes are about $20{\sim}25m$. Under the environment of short depression internal wave propagation, the variations of transmission loss field were investigated using an range-dependent acoustic transmission loss model(RAM). The result shows that the large irregular variations of transmission loss caused by progressing the internal wave from offshore toward coast.

파워흐름유한요소법을 이용한 진동음향 연성해석 연구 (Research on Vibro-acoustic Coupled Analysis using Power Flow Finite Element Method)

  • 김성희;권현웅;홍석윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.767-770
    • /
    • 2006
  • To predict vibrational energy density of simple structural-acoustic coupled systems in medium-to-high frequency ranges, Power Flow Finite Element Method(PFFEM) is used, and PFFEM sofiware, PFADS has been developed for the vibration predictions and analysis of coupled system structures in medium-to-high frequency ranges. However, it needs to consider vibro-acoustic coupled analysis to get more accurate results. Prior to implement vibro-acoustic coupled analysis functions in PFADS, research on vibro-acoustic coupled analysis using PFFEH is performed for simple models. These predictions include the indirect transmission path associated, and also the direct transmission path, and the formulation is extended to structural system model by using appropriate modifications to structural-acoustic and acoustic-acoustic joint matrices. Concerning the waves in plate and acoustic, it is possible to calculate the structural-acoustic full matrix of a model using PFFEM, and the formulations developed are implemented for two rooms surrounded by plates.

  • PDF

사각형 단순 확장소음기의 성능향상을 위한 입$\cdot$출구 위치의 최적설계 (Optimum Design for Inlet and Outlet Locations of Rectangular Expansion Chamber for Improving Acoustic Performance)

  • 김봉준;정의봉;황상문
    • 소음진동
    • /
    • 제9권4호
    • /
    • pp.738-746
    • /
    • 1999
  • The performance of muffler can be improved for a frequency range of interest by moving inlet and outlet locations. And optimal location of inlet and outlet can be determined to improve the acoustic performance. The optimum design using FEM, however, may take a very long time and be very hard to take inlet and outlet locations as design variables. In this paper, the acoustic performance of reactive type single expansion chamber muffler is predicted using higher order mode theory. The sensitivity analysis of transmission loss with respect to the location of inlet and outlet is suggested. And the acoustic power transmission coefficient for a frequency of interest is used as cost function. Optimum location of inlet and outlet is determined to minimize cost function by using SUMT algorithm.

  • PDF

펄스 튜브를 이용한 수중 음향 성능 측정 시스템 개발 (Development of Underwater Acoustic Performance Measurement System Using Pulse Tubes)

  • 서윤호;김상렬;이성민;변양헌;서영수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.603-608
    • /
    • 2014
  • Underwater acoustic materials are installed in order to reduce reflection, transmission and radiation of an underwater structure. The acoustic performance of the materials should be evaluated in accurately-controlled environment in terms of temperature and static pressure. In this paper, three pulse tubes, which is equipped with temperature and pressure controllers, are designed and developed to evaluate echo reduction and transmission loss for evaluating the performance below 10 kHz and 30kHz, respectively. The new procedures of the evaluation are suggested to improve the accuracy and the validation for the developed pulse tubes is carried out by comparing theoretical values to experimental ones.

  • PDF

Evaluation of Image Transmission for Underwater Acoustic Communication

  • Lee Seung-Woo;Choi Byung-Woong;Shin Chang-Hong;Kim Jeong-Soo;Lee Kyun-Kyung
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 ICEIC The International Conference on Electronics Informations and Communications
    • /
    • pp.110-113
    • /
    • 2004
  • Underwater acoustic(UWA) communication is one of the most difficult field because of several factors such as multipath propagation, high temporal and spatial variability of channel conditions. Therefore, it is important to model and analyze the characteristics of underwater acoustic channel such as multipath propagation, transmission loss, reverberation, and ambient noise. In this paper, UWA communication channel is modeled with a ray tracing method and applied to image transmission. Quadrature phase shift keying(QPSK) and multichannel decision feedback equalizer(DFE) are utilized as phase-coherent modulation method and equalization technique, respectively. The objective is to improve the performance of vertical sensor array than that of single sensor in the viewpoint of bit error rate(BER), constellation output, and received image quality.

  • PDF

유동속도가 단순확장관 음향투과손실에 미치는 영향 해석 (Effects of Fluid Velocity on Acoustic Transmission Loss of Simple Expansion Chamber)

  • 권진;정의봉;홍진숙
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.994-1002
    • /
    • 2012
  • Acoustic power transmission loss(TL) is an important performance of the muffler system. TL will be affected by the velocity of the fluid in duct since acoustic pressure varies according to the fluid velocity. In this paper, two kinds of fluid model, potential flow and turbulent flow, for the fluid flowing in simple expansion chamber are considered. The effects of their two fluid models in acoustic TL are investigated for the straight and L-shaped simple expansion chamber. In higher frequency range, the characteristics of TL of the two fluid models show different results. The variation of TL according to the fluid velocity is shown more distinctly when turbulence model is used. Turbulent flow model should be used to obtain better estimation of acoustic TL in higher frequency range.

유한요소법에 의한 흡음재 음향특성 연구 및 검증 (Finite Element analysis of Acoustic Behavior of Absorbent Materials with experimental Verification)

  • 정환익;김관주;박진규;김상헌
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.874-878
    • /
    • 2003
  • Acoustic materials are used for the purpose of absorbing noise and reducing transmission of sound into the receiving room. The purpose of this research is to predict the performance of absorbent materials with respect to absorbing behavior and transmission loss as possible as accurately. The performance of the absorbent materials are carried out systematically as follows: The Biot parameter are measured, first. Then using above parameters as input, LMS's SYSNOISE and VIOLINS programs are used to predict absorption coefficient and transmission loss values, which magnitudes are compared with experimental results. As an sample acoustic material, SK SKY VIVA and PET are selected.

  • PDF

Transmission Loss Estimation of Three Dimensional Silencers with Perforated Internal Structures Using Multi-domain BEM

  • Ju Hyeon-Don;Lee Shi-Bok
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1568-1575
    • /
    • 2005
  • The calculation of the transmission loss of the silencers with complicated internal structures by the conventional BEM combined with the transfer matrix method is incorrect at best or impossible for 3-dimensional silencers due to its inherent plane wave assumption. On this consideration, we propose an efficient practical means to formulate algebraic overall condensed acoustic equations for the whole acoustic structure, where particle velocities on the domain interface boundaries are unknowns, and the solutions are used later to compute the overall transfer matrix elements, based on the multi-domain BEM data. The transmission loss estimation by the proposed method is tested by comparison with the experimental one on an air suction silencer with perforated internal structures installed in air compressors. The method shows its viability by presenting the reasonably consistent anticipation of the experimental result.

ITE 타입의 소음 차폐기용 소형 음향 필터의 설계 (Design of Small Acoustic Filter for ITE Type Noise Protector)

  • 이윤정;김필운;장용민;이상흔;조진호;김명남
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.479-487
    • /
    • 2004
  • The prevention of noise induced hearing loss is very important, because there is no treatment for it. There are some kinds of devices for hearing protection, and those are effective in preventing a noise induced hearing loss. However, people often resist the use of hearing protection devices because it is difficult to have a conversation. Therefore, a hearing protection device is must effective not only in hearing protection but also in preserving communication ability. In this paper, we proposed a small acoustic filter for ITE type noise protector to solving the problem about the difficulties of conversation. That is applied a principle of acoustic filters that have been used for a muffler of automobiles, guns, and etc. To find out the sound transmission characteristic at the eardrum, we regarded an acoustic filter and external ear canal as a coupled system. So, we simulated the coupled system with OrCad, and experimented with a designed acoustic filter and a 2 cc coupler which has the same transmission characteristic as the external ear canal has. We confirmed that it is possible to adjustment acoustic transmission characteristics through simulation of electrical model for acoustic filter and external ear and experiments using designed small acoustic filters.