초음파의 매질 투과성을 이용한 시추공 케이싱 배면의 암상 및 절리구조 조사 연구 (Use of Ultrasonic beam transmissivity for investigating the structural features in plastic pipe cased borehole)

  • 김중열;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.751-758
    • /
    • 2002
  • Boreholes that are drilled in soft or unconsolidated materials such as gravels and coals are prone to collapse. To maintain the hole, some kinds of casing pipes are needed. If thereby a plastic pipe e.g. PVC is used for the casing, Televiewer tool is still capable of detecting structural features such as fractures in the borehole wall behind the pipe, whereas other borehole-imaging logging devices such as BIPS (Borehole Image Processing System) and FMS(Formation Micro Scanner) won't provide any information about that. Televiewer's primary component is a piezoelectric transducer centered in the hole. It acts as both a transmitter and receiver, and sends an ultrasonic beam. That is reflected, in the same manner as the seismic wave propagation, from the both sides(inner and outer surfaces) of the casing pipe, transmits through the pipe and then reflected from the borehole wall. With an appropriate choice of time-windowing, it is possible to capture the returning signals from both the borehole wall and the outer side of casing pipe as well. A suite of laboratory tests were performed on various physical models composed of plastic pipes with different diameters. Although the amplitudes of returning signals were reduced to about half the usual value due to the transmission loss, the dynamic range of Televiewer tool was sufficient to observe the structural features behind the casing pipe. Besides, several representative case studies at various research areas in our country are presented. The results demonstrate the usefulness of the transmissivity of Televiewer acoustic km, which will assist in further structural interpretation.

  • PDF

Feasibility Study on the Utilization of EMAT Technology for In-line Inspection of Gas Pipeline

  • Cho, Sung-Ho;Yoo, Hui-Ryong;Rho, Yong-Woo;Kim, Hak-Joon;Kim, Dae-Kwang;Song, Sung-Jin;Park, Gwan-Soo
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.36-41
    • /
    • 2011
  • If gas is leaking out of gas pipelines, it could cause a huge explosion. Accordingly, it is important to ensure the integrity of gas pipelines. Traditionally, over the years, gas-operating companies have used the ILI system, which is based on axial magnetic flux leakage (MFL), to inspect the gas pipelines. Relatively, there is a low probability of detection (POD) for the axial defects with the axial MFL-based ILI. To prevent the buried pipeline from corrosion, it requires a protective coating. In addition to the potential damage to the coating by environmental factors and external forces, there could be defects on the damaged coating area. Thus, it is essential that nondestructive evaluation methods for detecting axial defects (axial cracks, axial groove) and damaged coating be developed. In this study, an electromagnetic acoustic transducer (EMAT) sensor was designed and fabricated for detecting axial defects and coating disbondment. In order to validate the performances of the developed EMAT sensor, experiments were performed with specimens from axial cracks, axial grooves, and coating disbondment. The experimental results showed that the developed EMAT sensor could detect not only the axial cracks (minimum 5% depth of wall thickness) and axial grooves (minimum 10% depth of wall thickness), but also the coating disbondment.

Photoacoustic imaging of occlusal incipient caries in the visible and near-infrared range

  • da Silva, Evair Josino;de Miranda, Erica Muniz;de Oliveira Mota, Claudia Cristina Brainer;Das, Avishek;Gomes, Anderson Stevens Leonidas
    • Imaging Science in Dentistry
    • /
    • 제51권2호
    • /
    • pp.107-115
    • /
    • 2021
  • Purpose: This study aimed to demonstrate the presence of dental caries through a photoacoustic imaging system with visible and near-infrared wavelengths, highlighting the differences between the 2 spectral regions. The depth at which carious tissue could be detected was also verified. Materials and Methods: Fifteen permanent molars were selected and classified as being sound or having incipient or advanced caries by visual inspection, radiography, and optical coherence tomography analysis prior to photoacoustic scanning. A photoacoustic imaging system operating with a nanosecond pulsed laser as the light excitation source at either 532 nm or 1064 nm and an acoustic transducer at 5 MHz was developed, characterized, and used. En-face and lateral(depth) photoacoustic signals were detected. Results: The results confirmed the potential of the photoacoustic method to detect caries. At both wavelengths, photoacoustic imaging effectively detected incipient and advanced caries. The reconstructed photoacoustic images confirmed that a higher intensity of the photoacoustic signal could be observed in regions with lesions, while sound surfaces showed much less photoacoustic signal. Photoacoustic signals at depths up to 4 mm at both 532 nm and 1064 nm were measured. Conclusion: The results presented here are promising and corroborate that photoacoustic imaging can be applied as a diagnostic tool in caries research. New studies should focus on developing a clinical model of photoacoustic imaging applications in dentistry, including soft tissues. The use of inexpensive light-emitting diodes together with a miniaturized detector will make photoacoustic imaging systems more flexible, user-friendly, and technologically viable.

파라메트릭 어레이를 이용한 공기 중 디지털 통신 연구 (A Study on Digital Communication in Air Using Parametric Array)

  • 제엽;이재일;이종현;문원규
    • 한국음향학회지
    • /
    • 제28권8호
    • /
    • pp.768-773
    • /
    • 2009
  • 본 논문에서는 파라메트릭 어레이를 이용한 공기 중 디지털 통신의 특성을 측정해 보았다. 2차 오더의 비선형 현상인 파라메트릭 어레이를 구현하기 위하여, 고출력, 고효율의 음파 발생이 가능한 요철 트랜스듀서가 사용되었다. 1차 음파 (primary wave)의 주파수는 트랜스듀서 공진 주파수에 맞추어 83 kHz, 122 kHz 로 결정하였고, 이를 통해 발생되는 39 kHz의 차음 (difference frequency wave)을 통신 신호로 이용하였다. 통신 변조방법으로 On-Off Keying 방식을 이용하였다. 실험은 파라메트릭 어레이를 이용한 디지털 통신의 특성을 측정하기 위하여 파형 분석을 하였고, 거리, 각도에 따른 SNR을 측정해 보았다. 실험 결과 파라메트릭 어레이를 이용한 디지털 통신은 3m이내의 근거리 영역에서 적합함을 알 수 있었고, 빔폭 (-3 dB)은 $14^{\circ}$로 측정되어 고지향성 통신이 가능함을 확인하였다. 위의 실험 결과를 통해 파라메트릭 어레이를 이용한 공기 중 음향 통신에 대한 가능성을 확인하였고, 고지향성 통신 특성은 다중경로 문제나 보안 문제에 강점이 있을 것으로 판단된다.

N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과 (The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom)

  • 김연민;심재구;김상현
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.221-225
    • /
    • 2017
  • 초음파영상 진단장치의 성능을 평가할 때, 초음파장비에서 제공하는 음속변화 파라메타를 변화시킴에 따른 공간분해능의 변화를 알아보고자 하였다. 익산 소재 A기관에서 사용중인 초음파 진단장치에서 3.0 ~ 5.0 MHz 볼록형 탐촉자를 이용하여 초음파팬텀영상를 얻었다. N-365 다목적 초음파팬텀으로 종거리 측정정확도, 종 횡 해상도를 측정하였다. 같은 방법으로 초음파장치의 음속을1580 m/sec부터 1400 m/sec 까지 6단계로 변화시켜 측정 값의 차이가 있는지 image J 프로그램을 이용하여 반치폭을 측정하였다. 측정 결과, 횡측해상도는 속도변화에 따라 1.91 mm ~ 5.3 mm까지 측정되었으며, 음속 1420 m/sec 일 때 반치폭 1.91 mm로 가장 작게 측정되었다. 종측해상도는 1.03 mm ~ 1.14 mm까지 측정되었으며, 음속 1400 m/sec 일 때 반치폭 1.03 mm 로 가장 작게 측정되었다. 초음파장치의 음속이 느려질수록 종측정 길이가 짧아지는 상관관계를 보였다.

정재초음파를 이용한 유동중 미세 입자 위치 제어 (Position Control of Micro Particles in a Fluid Flow Using Ultrasonic Standing Wave)

  • 조승현;서대철;안봉영;김기복;김용일
    • 비파괴검사학회지
    • /
    • 제28권2호
    • /
    • pp.131-136
    • /
    • 2008
  • 정재초음파를 이용하면 유체에 잠겨 있거나 유체를 따라서 흐르는 미세 입자의 조작이 가능하다. 정재초음파 장이 입자에 힘을 작용하여 입자를 음압마디 또는 반음압마디로 이동시킨다. 본 연구에서는 정재초음파의 주파수를 조정함으로써 유동 중 미세 입자의 위치를 제어하는 방법을 제안하고자 한다. 이를 위해 먼저 수침형 초음파 트랜스듀서를 이용하여 폭 수 밀리미터의 미세 채널을 가지는 정재초음파 발생시스템을 구성하였다. 제안한 발생시스템을 이용하여 주파수 2 MHz부터 2.5 MHz까지 영역에서 정재초음파 장을 발생시키고, 물을 따라 흐르는 수 마이크로미터 내외의 탄화규소 입자가 음압 마디로 잘 이동함을 확인하였다. 이때, 미세 채널의 폭과 주파수가 입자의 거동에 미치는 영향을 관찰하였으며, 주파수가 미세입자의 이동 위치를 결정하는 중요한 파라미터임을 확인하였다. 결과적으로, 초음파의 주파수를 조정함으로써 입자의 이동 위치를 제어할 수 있음을 실험을 통해 확인하였으며 최대 범위는 약 261 마이크로미터이다. 본 연구로부터 유체내의 입자 조작에 있어서 정재초음파의 다양한 응용 가능성을 확인할 수 있었다.

강내온열 치료를 위한 원통형 초음파 치료기 개발 (Development of a cylindrical ultrasound applicator for Intracavitary Hyperthermia)

  • Lee, Rena J.;Hyunsuk Suh
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.79-84
    • /
    • 2002
  • 항문암 및 자궁경부암 치료시 사용되는 고선량률 강내 근접치료기와 병행하여 사용할 원통형 초음파 온열치료가 개발되었다. 온열치료를 위한 에너지원으로 원통형 트랜스듀서가(PZT-8 물질, 길이=1.5 cm 두께=1.5 mm 외경= 2.5cm) 사용되었다. PZT-8 물질의 특성을 측정하기위해 세 개의 단일 엘리멘트 어플리케이터가 제작되었다. PZT 물질을 작동하기 위한 주파수를 결정하기 위하여 벡터 임피던스가 측정되었다. 선택된 물질이 온열치료에 사용될 수 있는지 가능성을 타진하기위해 방사능력을 측정하는 방법으로 각 엘리맨트의 초음파발생 효율을 입력한 전기량과 발생한 초음파량의 비로 계산하였다. 마지막으로 질암의 온열치료에 사용할 수 있는 다채널 초음파 치료기가 디자인 되었다. 임피던스 실험결과 각 엘리맨트 1, 2, 그리고 3에 대해 1.78, 1.77, 그리고 1.77 MHz의 주파수에서 최대 임피더스 값을 얻었다. 방사능력 측정 실험결과 본 연구에서 사용된 에너지 소스는 40와트 이상의 초음파량이 방출되었다. 또한 각 엘리맨트 1, 2, 그리고 3의 평균 효율은 61.4, 65.2, 그리고 54.0% 이다. 본 연구에서 디자인되어진 원통형 초음파 치료기는 질 또는 항문 치료 시 고선량 강내근접치료와 더불어 사용할 수 있음이 증명되었다. 따라서 본 연구에서 개발된 온열 치료기구가 고 선량 강내 근접치료와 함께 사용하여 병변조직의 방사능 민감도를 증가시켜 암 치료효율을 높일수 있다.

  • PDF

신질환(腎疾患) 132례(例)의 초음파진단(超音波診斷) (Ultrasonographic Findings in 132 Cases of Renal Disease)

  • 한혜진;김강석
    • 보험의학회지
    • /
    • 제3권1호
    • /
    • pp.187-208
    • /
    • 1986
  • The conclusions which was acquired one renal cell carcinoma and renal disease 132 cases that was tested renal echogram among 4,499 cases for recent 16 months at medical department, Dae Han Kyoyuk Insurance company from August, 1984 to November, 1985 are as follows: 1. On bur ultrasonography, the echo of tumor was demonstrated with echogenicity as compared with renal parenchyme. 2. The case was stage I by Robson's modification method for pathologic histology. 3. There is no fever, typical triad of renal cell carcinoma and the result of serum biochemical test was within normal limit. 4. The frequency with disease was renal cell carcinoma(0.76%), ureteral stone(1.5%), multicystic kidney(2.27%), hydroureter(2.27%), Bilateral poly cystic kidney(4.55%), hydronephrosis(4.55%), renal agenesis(6.06%) renal calculi(18.18%), simple cyst(60.61%). 5. The frequency with age was 55/1200 case(4.58%) in $41{\sim}50$ years, 13/296 cases(4.39%) in $51{\sim}60$ years, 43/2144 cases(2.01%) in $31{\sim}40$ years, 14/791 cases(1.77%) in $21{\sim}30$ years, 7/53 cases(1.32%) more than 61 years and 0/15(0%) under 20 years. 6. The affected site of renal agenesis 8 cases was right side all. 7. In total renal disease 132 cases, the affected site of 126 cases except bilateral polycystic kidney 6 cases was right kidney 72 cases, left kidney the proportion of right to left 1.6:1 8. In total renal disease 132 cases except bilateral polycystic kidneys 6 cases, the patients affected with both side kidneys were 14 cases. 9. The affection rate with sex in total renal disease 132 cases was 98/2860 cases in male, 34/1819 cases in female and the former was about 2 times than the latter. 10. Classifying the stone with part, nephrolithiasis 24 cases were appeared high frequency, on the contray, ureteral stone 2 cases. 11. 2 cases of ureteral stone developed complication, hydronephrosis and hydroureter. 12. The linear array type transducer was not helpful for the diagnosis of lower ureteral calculi but for the lower ureteral calculi, we could see the stone with high echo in accompanying with acoustic shadowing. 13. In 24 cases of renal calculi, both side nephrolithiasis was 3 cases(12.5%). 14. In renal calculi, solitary stone could be seen extremely much and the number of stone was so much variable from 2 to 10. 15. In 26 cases with renal calculi and ureteral stone, the common clinical manifestation was a intermittent and slight pain. 16. In 80 cases of renal cyst, as one's get older, the affection rate of cyst extremely rised. 17. In bilateral polycystic kidney, large cyst had septum on the whole. 18. The patients with complication were 14 cases(10.6%) of total patients.

  • PDF

어군탐지기에 의한 어군량 추정에 관한 기초적 연구 ( 1 ) - 어군량추정이론의 검증실험 - (Studies on Estimation of Fish Abundance Using an Echo Sounder ( 1 ) - Experimental Verification of the Theory for Estimating Fish Density-)

  • 이대재
    • 수산해양기술연구
    • /
    • 제27권1호
    • /
    • pp.1-12
    • /
    • 1991
  • 적분방식에 의한 어군량추정법을 실험적으로 검증하기 위하여, 실험수조에서 50 kHz와 200 kHz의 주파수를 대상으로 모의어군의 분포밀도와 초음파산란강도의 관계를 검토하고, 또 계량어군탐지기의 정도를 개선하기 위한 문제들에 대하여 고찰을 행한 결과를 요약하면 다음과 같다. 1. 어체의 모의표적으로 이용한 steel ball (직영 35mm)의 실측 echo 파형은 이론 echo 파형과 잘 일치하였다. 2. 5 종류의 주파수에 대하여 고등어 (체장 36cm)의 반사주파수특성을 조사한 결과, 측정주파수가 변화함에 따라 어체에 의한 echo 신호의 진폭과 파형이 크게 변동하고 있음을 알 수 있었다. 3. 송수파기의 음속 내에서 5개/m 상(3)와 30개/m 상(3)의 표적 군이 서로 상하로 존재할 때, 상부 표적군의 존재에 의해 하부 표적군의 echo level이 -0.43 dB 감쇠하는, 소위 그늘효과(shadowing effect)가 발생하였다. 4. 동지나해에서 정박 중에 탐지한 고밀도 어군의 echo신호와 그 어군직하의 해저에서 산란된 echo 신호를 상호 연관시켜 분석한 결과, 어군층내에서 발생한 어군감쇠와 다중산란효과가 해저 echo 신호의 변동에 큰 영향을 미치고 있음을 알 수 있었다. 5. 정치망의 원통에 인망한 정어리의 단위체적당에 대한 분포밀도가 36마리/m 상(3)였을 때, 해저기녹이 소실되는 어군감쇠현상과, 어군 echo 신호가 해저까지 신장되는 다중산란현상이 동시에 발생하였다. 6. 50kHz와 200kHz의 주파수에서 표적군의 평균체적산란강도(:dB)와 표적의 분포밀도($\rho$:개/m 상(3))의 간에 다음의 회귀직선식을 얻었다. 50kHz : =-46.2+13.7 Log($\rho$). 200kHz : =-43.9+13.4 Log($\rho$). 7. 표적의 분포밀도가 5, 10, 15, 20, 25, 30 개/m 상(3)였을 때, 적분방식에 의한 추정치는 50kHz에서 2.0, 8.1, 9.9, 14.1, 19.2, 26.7 개/m 상(3)이었고, 200kHz에서는 2.0, 8.0, 9.1, 15.0, 20.1, 24.1 개/m 상(3)이었으며, 단위체적당에 분포하는 표적의 수가 많을수록, 그 추정치의 정도가 높아지는 경향을 나타내었다. 또한, 양주파수에서 분포밀도의 추정치는 실제보다 약 30%정도 과소추정되었다.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF