• 제목/요약/키워드: Acoustic transducer

검색결과 391건 처리시간 0.031초

Low Attenuation Waveguide for Structural Health Monitoring with Leaky Surface Waves

  • Bezdek, M.;Joseph, K.;Tittmann, B.R.
    • 비파괴검사학회지
    • /
    • 제32권3호
    • /
    • pp.241-262
    • /
    • 2012
  • Some applications require structural health monitoring in inaccessible components. This paper presents a technique useful for Structural Health Monitoring of double wall structures, such as double wall steam pipes and double wall pressure vessels separated from an ultrasonic transducer by three layers. Detection has been demonstrated at distances in excess of one meter for a fixed transducer. The case presented here is for one of the layers, the middle layer, being a fluid. For certain transducer configurations the wave propagating in the fluid is a wave with low velocity and attenuation. The paper presents a model based on wave theory and finite element simulation; the experimental set-up and observations, and comparison between theory and experiment. The results provide a description of the technique, understanding of the phenomenon and its possible applications in Structural Health Monitoring.

수중 음향 압전 트랜스듀서의 등가 회로 모델링 (Equivalent Circuit Modeling of Underwater Acoustic Piezoelectric Transducer)

  • 조치영;서희선;이정민
    • 한국음향학회지
    • /
    • 제15권4호
    • /
    • pp.77-82
    • /
    • 1996
  • 본 연구에서는 샌드위치형 압전 트랜스듀서의 등가 회로 모델을 규명하는 방법을 제시하였다. 공기중에서 실험적으로 측정한 트랜스듀서의 전기적 어드미턴스와 이론적으로 계산된 어드미턴스의 오차가 최소가 되도록 하는 비선형 최적화 문제를 풀어 등가 회로에 관련된 미지 상수를 규명하였다. 예제 트랜스듀서에 대해 제안된 방법을 적용하여 등가회로를 모델링하고, 수중에서의 송신 음압 감도(TVR) 및 수신 읍압 감도(RVS)을 예측하고 실험치와 비교하여 규명된 등가 회로 모델의 타당성을 검증하였다.

  • PDF

고분자(高分子) PVDF 진동자(振動子)를 이용(利用)한 점집동초음파탐촉자(点集東超音波探觸子)의 특성 (Characteristics of Point-Focus Type Ultrasonic Transducer using PVDF Element)

  • 한응교;황석태;이범성;박준서;소창행부
    • 비파괴검사학회지
    • /
    • 제12권2호
    • /
    • pp.7-13
    • /
    • 1992
  • In this study, we examine the characteristics of beam and the effect of these characteristics on the flaw detection by using different type of two transducers, which are PZT and PVDF film transducer. Consequently, the detection of infinitesimal flaw is more possible than PZT, since it has beam width at focus of $60%{\sim}65%$ in contrast with PZT's. Moreover we can know PVDF transducer has superiority in detecting ability for sub-surface flaw detection in view of its acoustic impedance is near to water's and its focusing range is narrower than PZT's as $65{\sim}85%$ because it has spherical surface.

  • PDF

Hopper WDM을 이용한 FBG(Fiber Bragg Grating) 하이드로폰(Hydrophone)의 다중점신호검출 및 지향성 연구 (A Study on The Multi-point Signal and It's Directivity detection of FBG Hydrophone Using Hopper WDM be in The Making)

  • 김경복
    • 전자공학회논문지
    • /
    • 제52권11호
    • /
    • pp.156-163
    • /
    • 2015
  • 국내에서 개발된 단일모드 균일한 단주기형 광섬유 격자소자(FBG: Fiber Bragg Grating)를 이용하여, 수중에서 음파를 검출할 수 있는 FBG 일체형 Transducer를 설계 및 제작하였다. 이를 통하여 신호검출 시스템구성 시, 최근 제작된 Hopper WDM(특허번호 제10-1502954)을 이용하여 수중에서 다중점신호검출과 지향성 연구를 한 결과, 기존의 광섬유 센서가 지니고 있는 우수한 장점들을 모두 지니고 있을 뿐만 아니라, Sensor Arm 구성이 간단하여 실용화에 큰 장점을 지니고 있다. 제작된 FBG 일체형 트랜스듀서는 30 Hz~2.5KHz 범위에서 주파수 검출이 가능하고, 최적의 공진조건 주파수는 1.2KHz로 나타났다. 또한, 이를 이용한 수중에서 넓은 영역에 대한 다중점 신호 검출을 구현하기 위하여, WDM(Wavelength Division Multiplexing) 방법과 Passive band-pass filter system을 이용하여 FBG Hydrophone Arrays System을 구축하고, 2개의 FBG 일체형 Transducers에서 주파수 200Hz~1.3 KHz대까지 다중점 수중 음파 신호 검출을 성공 하였다. 아울러, 음원의 방향과 각도에 따라 검출된 신호의 세기가 변화되므로 음원의 물체에 대한 방향성 검출이 가능함으로서, 향후 FBG Hydrophone의 실용화 연구에 새로운 기틀을 마련하였다.

초음파 영상 진단기용 선형 어레이 변환기의 채널별 음향파워 측정 (Measurement of Acoustic Power Radiating from Each Channel of Linear Array Transducer for Diagnostic Ultrasonic Imaging System)

  • 윤용현;조문재;김용태;이명호
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 추계학술발표대회논문집 제23권 2호
    • /
    • pp.351-352
    • /
    • 2004
  • 본 논문에서는 초음파 영상 진단기용 선형어레이 변환기를 장착할 수 있는 수조 와 128 채널의 스위칭 회로를 제작하여 변환기의 각 채널별 음향파워를 측정하였다. 실험은 128 채널 중 하나의 채널이 불량인 어레이 프로브를 대상으로 수행되었다. 측정 결과, 불량 채널의 음향 파워가 다른 채널에 비해 현저히 작게 나타남을 확인하였다.

  • PDF

다수의 청취자를 위한 가상음향 시스템의 크로스토크 제거 (Crosstalk cancellation of virtual acoustic imaging systems for multiple listeners)

  • 김영태
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 추계학술발표대회논문집 제23권 2호
    • /
    • pp.333-334
    • /
    • 2004
  • The central aspect of the research into virtual acoustic imaging for multiple listeners involves a detailed study of the relative orientation of both sources and listeners. It is vital in any multiple listener system to first establish the conditioning of the potential geometrical arrangements of transducers and listeners. In this paper, this made clear the important link between the conditioning of the electro-acoustic transfer function matrix between transducers and ears and the design of inverse filters for crosstalk cancellation. This work has been undertaken by using simple free field models of the electro-acoustic transfer functions. Therefore, optimal transducer arrangements have been identified and these have been proved by time domain solutions.

  • PDF

Non-contact Transportation of Flat Panel Substrate by Combined Ultrasonic Acoustic Viscous and Aerostatic Forces

  • Isobe, Hiromi;Fushimi, Masaaki;Ootsuka, Masami;Kyusojin, Akira
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권2호
    • /
    • pp.44-48
    • /
    • 2007
  • In recent years, the size of plane substrates and semiconductor wafers has increased. As conventional contact transportation systems composed of, for example, carrier rollers, belt conveyers, and robot hands carry these longer and wider substrates, the increased weight results in increased potential for fracture. A noncontact transportation system is required to solve this problem. We propose a new noncontact transportation system combining acoustic viscous and aerostatic forces to provide damage-free transport. In this system, substrates are supported by aerostatic force and transported by acoustic viscous streaming induced by traveling wave deformation of a disk-type stator. A ring-type piezoelectric transducer bonded on the stator excites vibration. A stator with a high Q piezoelectric transducer can generate traveling vibrations with amplitude of $3.2{\mu}m$. Prior to constructing a carrying road for substrates, we clarified the basic properties of this technique and stator vibration characteristics experimentally. We constructed the experimental equipment using a rotational disk with a 95-mm diameter. Electric power was 70 W at an input voltage of 200 Vpp. A rotational torque of $8.5\times10^{-5}Nm$ was obtained when clearance between the stator and disk was $120{\mu}m$. Finally, we constructed a noncontact transport apparatus for polycrystalline silicon wafers $(150(W)\times150(L)\times0.3(t))$, producing a carrying speed of 59.2 mm/s at a clearance of 0.3 mm between the stator and wafer. The carrying force when four stators acted on the wafer was $2\times10^{-3}N$. Thus, the new noncontact transportation system was demonstrated to be effective.

표면파 유도 음향방사력을 이용한 미세액적의 크기 선별 (Size-based separation of microscale droplets by surface acoustic wave-induced acoustic radiation force)

  • 무스타크 알리;차범석;무하마드 소반 칸;전현우;이송하;김우혁;고정우;박진수
    • 한국가시화정보학회지
    • /
    • 제20권3호
    • /
    • pp.19-26
    • /
    • 2022
  • In droplet microfluidics, precise droplet manipulation is required in numerous applications. This study presents ultrasonic surface acoustic wave (USAW)-based microfluidic device for label-free droplet separation based on size. The proposed device is composed of a slanted-finger interdigital transducer on a piezoelectric substrate and a polydimethylsiloxane microchannel placed on the substrate. The microchannel is aligned in the cross-type configuration where the USAWs propagate in a perpendicular direction to the flow in the microchannel. When droplets are exposed to an acoustic field, they experience the USAW-induced acoustic radiation force (ARF), whose magnitude varies depending on the droplet size. We modeled the USAW-induced ARF based on ray acoustics and conducted a series of experiments to separate different-sized droplets. We found that the experimental results were in good agreement with the theoretical estimation. We believe that the proposed method will serve as a promising tool for size-based droplet separation in a label-free manner.

도플러효과에 의한 주파수 변화에 대응하는 수중 초음파변환자의 제안 (An Underwater Acoustic Transducer Responding to Frequency Shift by Doppler Effect)

  • 김정환;김무준;하강열
    • 센서학회지
    • /
    • 제8권1호
    • /
    • pp.16-23
    • /
    • 1999
  • 수중에서 초음파변환자가 이동하면서 정지하고 있는 물체를 탐지하는 경우, 도플러(Doppler)효과에 의해 생기는 반사파의 주파수 편이 때문에 수신감도가 저하하게 된다. 이를 막기 위한 방법으로 본 연구에서는 기존의 주파수 가변형 초음파변환자의 기계임피던스 가변용 압전층에 새로이 설계 제작한 유속감지형 가변콘덴서를 부착함으로써, 변환자의 이동속도에 따라 공진주파수가 자동적으로 추종하는 수중 초음파변환자를 제안하고, 그 특성을 조사하였다. 그 결과, $1{\sim}10^m/_s$의 속도범위에서 이론 계산치와 실험치는 비교적 좋은 일치를 나타내어, 도플러 효과에 의한 수신감도의 저하를 막을 수 있음이 확인되었다.

  • PDF

유한요소법과 하이브리드형 무한요소법을 이용한 초음파 집속변환자의 음장 해석 (Acoustic Field Analysis of Ultrasonic Focusing Transducer by Using Finite Element. Method and Hybrid Type Infinite Element Method)

  • 박순종;윤종락;하강열;김천덕
    • 한국음향학회지
    • /
    • 제14권5호
    • /
    • pp.36-43
    • /
    • 1995
  • 본 논문에서는 유한요소법과 하이브리드형 무한요소법을 사용하여 전기계$\cdot$기계계$\cdot$음향계로 결합된 초음파 집속변환자의 집속특성과 시간 응답을 구하였다. 초음파 집속변환자의 촛점거리, 분해능 특성들을 구하였고, 댐퍼가 부가된 경우 방사면상의 변위분포가 안정되어 분해능이 개선된다는 것을 집속특성과 시간 응답으로부터 해석하였다. 해석의 결과는 초음파 집속변환자의 설계나 성능해석에 응용될 수 있을 것이다.

  • PDF