• 제목/요약/키워드: Acoustic and vibration isolation

검색결과 20건 처리시간 0.021초

디젤엔진의 근접 음향 차폐장치 설계 및 성능평가 (Design of Close-Fitting Acoustic Enclosure of Diesel Engine)

  • 류정수;정우진;전재진
    • 한국군사과학기술학회지
    • /
    • 제2권1호
    • /
    • pp.82-89
    • /
    • 1999
  • In this article, the performances of acoustic enclosure with double resilient mount system which was designed by ADD to reduce the radiated noise by main noise source of ships, was tested and evaluated. From test results, it was verified that the acoustic performances of acoustic enclosure satisfied the requirements; vibration isolation level at 1st stage mount system of 15 ㏈ and airborne noise reduction level of 20 ㏈ in broad band.

  • PDF

소나 음향센서의 진동유기 소음 차단 특성에 대한 실험적 연구 (An experimental analysis of vibration-induced noise isolation characteristics of a sonar acoustic sensor)

  • 김경섭;제엽;김호준;조요한;이정민;김동현;장우석
    • 한국음향학회지
    • /
    • 제38권2호
    • /
    • pp.193-199
    • /
    • 2019
  • 본 논문에서는 선체부착형 음향센서의 플랫폼 진동유기 소음 차단 특성을 확인하기 위한 수중 진동 실험을 수행하고 결과를 분석하였다. 음향수조 환경에서 음향센서가 설치된 선체모사구조물과 가진기를 이용하여 플랫폼 진동유기 소음 조건을 구현하였고, 선체모사구조물 및 음향센서에 설치된 표준 가속도계와 음향센서의 출력신호 측정을 통해 음향센서의 진동차단율, 삽입손실 및 진동민감도와 같은 성능지수를 산출하였다. 산출된 성능지수 결과를 토대로 음향센서의 주파수별 소음 차단 특성을 분석하고 실험 기법의 유효성을 검토하였다.

대형 잔향실의 방진 구조 설계 및 검증시험 (Design and Verification of a Large Reverberation Chamber's Isolation System)

  • 김홍배;이득웅
    • 한국소음진동공학회논문집
    • /
    • 제14권11호
    • /
    • pp.1066-1074
    • /
    • 2004
  • A vibration isolation system for a large reverberation chamber (1,228 $m^3$ and 1,000 ton) has been installed and verified. The reverberation chamber generates loud noise and induces high level of vibration while performing spacecraft acoustic reliability tests. The isolation system prevents vibration transfer from the chamber to the enclosure buildings. This paper describes design process and commissioning experiments of the system. Design criteria have been derived from rigid body model of the chamber. The stiffness of neoprene pads has been selected by employing finite element analysis of the reverberant chamber and isolation system. A total of 21 neoprene pads have been installed between the chamber and supporting Pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. While 136.9 dB noise is generated in the chamber, absolute transmissibility of the isolation system has been measured. The measured natural frequency of the chamber is 10.2Hz, which is 80% of the predicted value. Overall transmissibility at working frequency range (25∼10.000 Hz) is less than -12.4 dB.

Numerical investigation on multi-degree-freedom nonlinear chaotic vibration isolation

  • Jiang, Guoping;Tao, Weijun
    • Structural Engineering and Mechanics
    • /
    • 제51권4호
    • /
    • pp.643-650
    • /
    • 2014
  • A chaotic vibration isolation system is designed according to the chaotic vibration theory in this paper. The strong nonlinearity is generated by the system. Line spectra in the radiated noise maybe easily detected caused by marine vessels. It is Important to reduce the line spectra by improving the acoustic stealth of marine vessels. A multi-degree-freedom (MDF) nonlinear vibration isolation system (NVIS) system is setup by the experiment and finite element method. The model is established with finite element method. The results show that the behavior of the device gradually varies from period bifurcation into chaotic state and the line spectrum is changed from single spectral structure into broadband spectral structure. It is concluded that chaotic vibration isolation is preferable contrasted on line spectra isolation.

대형 잔향실의 방진 설계 및 검증 (Vibration Isolation System of a Large Reverberation Chamber)

  • 김영기;김홍배;이동우;우성현;문상무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.1026-1031
    • /
    • 2003
  • A vibration isolation system fur a large reverberation chamber (1,228㎥, 1,000ton) has been installed. The reverberation chamber generates loud noise and induces high level of vibration to perform spacecraft acoustic environmental tests. The isolation system prevents vibration transfer from the chamber to enclosure buildings. This paper describes logical design process and commissioning experiments of the system. Design criteria have been induced from rigid body model of the chamber. Finite element model has been employed to select the characteristics of rubber pads. A total of 21 rubber pads have been installed between the chamber and supporting pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. Absolute transmissibility has been measured while generating 145㏈ in the chamber. The natural frequency of the chamber is 10.5㎐, which is 80% of estimated value. Overall transmissibility at working frequency range (25㎐-10,000㎐) is less than -6㏈.

  • PDF

소음 차단링을 이용한 구조물의 음향진동 차단 특성 연구 (Acoustic and Vibration Isolation Characteristics Using SNORE Ring in the Structure)

  • 이종길;구정모;조치영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.336-337
    • /
    • 2010
  • In the underwater veicle self-noise from the propeller reduces the sensor sensitivity. To increase the sensor sensitivity SNORE ring(Self-noise reduction ring) has been used. In this paper to calculate the effectiveness of the SNORE ring and de-coupeler numerical simulation is conducted. Based on the simulation results CRP(Carbon reinforced plastic)and SNORE ring reduced noise and vibration.

  • PDF

마운트의 음향강성 측정을 위한 시험장치 개발 (A Development of the Test Apparatus for Measuring the Acoustic Stiffness of Resilient Mounts)

  • 배수룡;정우진;함일배;김두기;이헌곤
    • 소음진동
    • /
    • 제9권1호
    • /
    • pp.141-148
    • /
    • 1999
  • Resilient mounting is effective measures to reduce the structure-borne noise and radiated noise for many applications. The acoustic stiffness (frequency-dependent stiffness) of resilient mounts is an important parameter required in order to model vibration isolation with high accuracy. It is general to use measurement method for obtaining acoustic stiffness of complex resilient mounts under static preload. In this paper, the principles of measuring acoustic stiffness were described and the developed test apparatus was introduced. Also, the feasibility of the test apparatus is illustrated by measurement results of a resilient mount.

  • PDF

공동주택 성능등급 표시제도 상의 음성능 표시기준 고찰 (A Study on the Acoustic Performance Indication Standards of Apartment Housing Performance Grade Indication System)

  • 양관섭;김경우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1252-1255
    • /
    • 2006
  • The government has enforced Housing Performance Grade Indication System (Article 21, Paragraph 2 of Housing Act) starting January 2006 for the purpose of giving users in hope of toying an apartment opportunities to select housing based on personal preferences by providing information on housing performance at the time of tenant recruitment announcement as well as securing desirable environment (comfort) by encouraging construction companies to build housing of the indicated performance level. The acoustic performance indication items include three items such as floor impact isolation performance(light weight impact sound, heavy weight impact sound), bathroom noise and insulation performance of boundary walls between households. This paper explains the background, the basis of creation and evaluation method focused on the acoustic environment performance helping for the developer of technique and a staff in charge of construction business who cope with this system.

  • PDF

차음재의 음향투과손실 측정에 Two-Microphone Impedance Tube Method의 적용과 한계 (The Limit and Application of Two-microphone Impedance Tube Method to the Sound Transmission Loss Measurement of Sound Isolation Materials)

  • 이승;안민홍;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.883-888
    • /
    • 2002
  • This study describes the limit and application of the two-microphone impedance tube method to the sound transmission loss measurement of several sound isolation materials with different physical properties. For the sound isolation materials having small flexural rigidity, it is shown that the two-microphone impedance tube method is validated to practically measure the sound transmission loss. For the sound isolation materials having large flexural rigidity, on the other hand, it is found that the two-microphone impedance tube method is no longer valid to measure the sound transmission loss because the regions of resonance and mass law are moved into the higher frequencies. In addition, in order to accurately measure the sound transmission loss of sound isolation materials, their size should be decided based on the consideration of the effect of acoustic excitation on their vibration response.

  • PDF