• Title/Summary/Keyword: Acoustic Measurement

Search Result 901, Processing Time 0.024 seconds

Control Measures for Air Pollutant Emissions from In-Use Light-Duty Diesel Vehicles Regarding their Emission Control Technologies (배출허용기준 대응기술을 고려한 국내 소형 경유 운행차의 대기오염물질 관리 방안)

  • Lee, Taewoo;Park, Hana;Park, Junhong;Jeon, Sangzin;Kim, Jeongsoo;Choi, Kwangho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.327-338
    • /
    • 2014
  • The objective of this study is to enhance the effectiveness of Korean Inspection and Maintenance (I/M) program. Three main tasks are: to measure pollutant emissions of in-use light-duty diesel vehicles (LDVs); to evaluate the validity of existing smoke control scheme for low-smoke-emitting vehicles, which have diesel particulate filters, DPF, to meet stringent Euro-5 emission limits; and to assess the necessity and the benefit of $NO_x$ inspection, which is not involved in current I/M program. We measured second-by-second smoke, particulate and gaseous emissions of 27 LDVs using opacity smoke meter, photo-acoustic soot sensor, and portable emissions measurement system, respectively, under the Korean I/M test driving cycle, KD-147. We find that the DPF plays a key role in controlling soot, which can be considered as black carbon contained in particulate matter. Thus, from an I/M perspective, we believe smoke inspection strategies for Euro-5 diesel vehicles should be more focused on the capability of detecting DPF malfunctions or failures, in order to keep DPF properly functional. Fleet averaged distance-specific $NO_x$ emissions are consistently higher than corresponding emission limits, and the values are similar among pre-Euro-3, Euro-3, and Euro-4 vehicle fleets. These findings indicate that the $NO_x$ inspection should be incorporated into current I/M program in order to manage urban $NO_x$ emissions. This research allows the Korean I/M program keep pace with developments in vehicle technologies, as well as the increased emphasis on $NO_x$ with respect to air quality and human health.

The Noise Level Assessment of Dental Equipment (치과 의료장비의 소음 수준 평가)

  • Lee, Jeong-Suk;Han, Ye-Seul;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.603-611
    • /
    • 2015
  • This research is aimed at cutting off hearing loss and other harmful factors due to noise and providing basic material for noise reduction plan. As the research method, this research assessed noise by measuring acoustic pressure level and frequency in various situation of non-treatment and treatment. As the measurement result, average noise degree of high speed handpiece of non-treatment, ultrasonic waves scaler, and low speed handpiece showed 58~66 dB(A). Average noise degree of scaling of treatment, tooth elimination, and denture adjust showed 73~81 dB(A). The result is inferior to recognized standards of noise induced hearing loss. But the result of assessing this with (noise rating) NR curve was NR-73~78, which exceeded general workplace noise standard. This level can cause hearing loss when exposed to a long time. Therefore, treatment office noise during dental treatment can cause psychological and physical damage in dental clinic employees, and it is urgently required to establish systematic and active noise reduction plan.

Study for Correlation between Objective and Subjective Voice Parameters in Patients with Dysphonia (발성장애 환자에서 주관적 음성검사와 객관적 음성검사의 연관성 연구)

  • Park, Jung Woo;Kim, Boram;Oh, Jae Hwan;Kang, Tae Kyu;Kim, Dong Young;Woo, Joo Hyun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.30 no.2
    • /
    • pp.118-123
    • /
    • 2019
  • Background and Objectives Voice evaluation is classified into subjective tests such as auditory perception and self-measurement, and objective tests such as acoustic and aerodynamic analysis. When evaluating dysphonia, subjective and objective test results do not always match. The purpose of this study was to analyze the relationship between subjective and objective evaluation in patients with dysphonia and to identify meaningful parameters by disease. Materials and Method The total of 322 patients who visited voice clinic from May 2017 to May 2018 were included in this study. Laryngeal lesions were identified using stroboscopy. Pearson correlation test was performed to analyse correlation between subjective tests including GRBAS scale and voice handicap index, and objective tests including jitter, shimmer, noise to harmonic ratio (NHR), cepstral peak prominence (CPP), maximal phonation time (MPT), mean flow rate, and subglottic pressure. Results In vocal nodule and sulcus vocalis, among GRBAS system, grade and breathiness showed good correlation with CPP, and roughness showed good correlation with jitter or shimmer. In unilateral vocal cord paralysis (UVCP), grade and breathiness showed a very good correlation with CPP, and also good correlation with jitter, shimmer, NHR, and MPT. Also asthenia showed good correlation with CPP and MPT. Vocal polyp has a limited association with other diseases. Conclusion In patients with dysphonia, grade and breathiness showed good correlation with CPP, jitter, and shimmer, and reflect the state of voice change well especially in UVCP, CPP, and MPT.

Automatic Discharge Measurement Using the Velocity Index Method (유속지수법을 이용한 자동유량측정)

  • Kim, Chi-Young;Kim, Won;Lee, Chan-Joo;Kim, Dong-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.242-246
    • /
    • 2006
  • 최근 들어 전 세계적으로 유량측정 분야의 큰 변화의 방향은 자동화이다. 전자, 전기 기술과 정보통신 기술의 발달을 유량측정 분야에 적용하여 자동적으로 유량측정을 수행하고 실시간으로 모든 유량자료를 수집하는 시스템을 구성하려는 연구가 활발하게 진행중이다. 최근에 초음파 유량계와 더불어 자동 유량측정 기법으로 각광을 받고 있는 기법이 유속지수법(index velocity method)이다. 유속지수법의 원리는 매우 간단하다. 수위 기록을 통하여 수위-면적 관계로부터 흐름 단면적을 구하고, 임의의 영역에서 측정된 유속이 단면 평균 유속으로 환산될 수 있다면, 흐름 단면적과 평균 유속에 의해 연속적으로 유량을 구할 수 있다. 유속지수법에서 가장 중요한 것이 전체 평균 유속을 대표할 수 있는 유속지수를 정확하고 효율적으로 측정하는 것이다. 유속지수법에 의한 연속 유량측정 목적으로 최근에 ADVM(Acoustic Doppler Velocity Meter)이 개발되어 이용되고 있다. ADVM은 수중에 초음파를 발사해서 산란체에서 반사되어 돌아오는 초음파의 주파수 편이, 즉 도플러 효과를 이용하여 유속을 측정하는 유속계이다. 본 연구에서는 ADVM을 괴산댐 하류에 위치한 시험하천에 설치하여, 유속지수법에 의한 유량측정기법을 적용하고 그 특성을 분석하였다. 유속지수법으로 측정된 유량을 괴산댐 방류량과 비교한 결과 평균 4.0%의 상대오차를 지니고 있어 비교적 정확한 연속 유량측정이 가능한 것으로 나타났다. 이와 같은 유속지수법을 하천 유량측정에 활용하면 보다 정확한 유량을 연속적으로 자동화하여 측정할 수 있을 것으로 기대된다.연계모형의 한계로 인하여 두 모형의 통합모형이 필요하다. 즉, 강우 혹은 월류유량으로 발생한 지표유량 중 일부분이 과부하가 발생하지 않는 유입구 지점을 통과할 때 배수시스템으로 유입되는 것을 고려할 수 있고, 유입된 유량은 배수시스템 내의 흐름에 반영되도록 배수시스템과 침수해석모형을 통합한 모형 개발이 필요하다. 그러기 위해서는 지표면과 배수시스템에 대한 수리학적 관계를 정립하여야 한다. 본 연구에서는 배수시스템 해석 모형과 도시침수해석 모형을 통합하고, 두 모형간의 유량의 전송과정을 수리학적 관계를 고려한 dual-drainage 도시침수해석모형을 개발하였다. 이를 위해 도시지역 배수시스템 해석 모형으로 널리 이용되고 있는 SWMM모형을 이용하여 지표면으로의 월류량을 산정하고 유입된 지표유량에 대해서 배수시스템에서의 흐름해석을 수행하였다. 그리고, 침수해석을 위해서는 2차원 침수해석을 위한 DEM기반 침수해석모형을 개발하였고, 건물의 영향을 고려할 수 있도록 구성하였다. 본 연구결과 지표류 유출 해석의 물리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기

  • PDF

Internal Defection Evaluation of Spot Weld Part and Carbon Composite using the Non-contact Air-coupled Ultrasonic Transducer Method (비접촉 초음파 탐상기법을 이용한 스폿용접부 및 탄소복합체의 내부 결함평가)

  • Kwak, Nam-Su;Lee, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6432-6439
    • /
    • 2014
  • The NAUT (Non-contact Air coupled Ultrasonic Testing) technique is one of the ultrasonic testing methods that enables non-contact ultrasonic testing by compensating for the energy loss caused by the difference in acoustic impedance of air with an ultrasonic pulser receiver, PRE-AMP and high-sensitivity transducer. As the NAUT is performed in a state of steady ultrasonic transmission and reception, testing can be performed on materials of high or low temperatures or specimens with a rough surface or narrow part, which could not have been tested using the conventional contact-type testing technique. For this study, the internal defects of spot weld, which are often applied to auto parts, and CFRP parts, were tested to determine if it is practical to make the NAUT technique commercial. As the spot welded part had a high ultrasonic transmissivity, the result was shown as red. On the other hand, the part with an internal defect had a layer of air and low transmissivity, which was shown as blue. In addition, depending on the PRF (Pulse Repetition Frequency), an important factor that determines the measurement speed, the color sharpness showed differences. With the images obtained from CFRP specimens or an imaging device, it was possible to identify the shape, size and position of the internal defect within a short period of time. In this paper, it was confirmed in the above-described experiment that both internal defect detection and image processing of the defect could be possible using the NAUT technique. Moreover, it was possible to apply NAUT to the detection of internal defects in the spot welded parts or in CFRP parts, and commercialize its practical application to various fields.

Numerical Study on Cavitation Flow and Noise in the Flow Around a Clark-Y Hydrofoil (Clark-Y 수중익형 주변 공동 현상에 의한 유동장과 소음 예측에 대한 수치적 연구)

  • Ku, Garam;Cheong, Cheolung;Kim, Sanghyeon;Ha, Cong-Tu;Park, Warn-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.2
    • /
    • pp.87-94
    • /
    • 2017
  • Because the cavitation flow driven by an underwater propeller corrodes the materials around it and generates a high level of noise, it has become an important topic in engineering research. In this study, computational fluid dynamics techniques are applied to simulate cavitation flow, and the noise in the flow is predicted by applying the acoustic analogy to the predicted flow. The predicted results are compared with measurement results and other predictions in terms of surface pressure distribution and the temporal variation in liquid volume fraction. The predicted results are found to be in good agreement with the measured results. The source of the noise attributed to the time rate of change in the liquid volume fraction around the hydrofoil is modeled as a monopole source, and the source of the noise due to unsteady pressure perturbations on the hydrofoil surface is modeled as a dipole source. Then the predicted noise results are analyzed in terms of directivity and SPL spectrum. The noise caused by unsteady pressure perturbations was dominant in the entire frequency range considered in the study.

Mismatch Negativity Using Frequency Difference in Healthy Young Adults: Latency and Amplitude (건강하고 젊은 성인에서 주파수 차이를 이용한 불일치음전위: 잠복기와 전위)

  • Jung, Seokwon;Kim, Young-Soo;Yang, Tae-Won;Kim, Do-Hyung;Kim, Min Su;Bae, Sang Hyeon;Kim, Ga-In;Kwon, Oh-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.194-201
    • /
    • 2020
  • Latency and amplitude are the measurement parameters of mismatch negativity (MMN). The values of the parameters vary sensitively with the stimulus paradigm. A paradigm using the frequency difference of sounds for the MMN study is well known. This study obtained the reference values of the parameters in healthy young adults by performing the MMN study using the frequency paradigm. The authors recruited ten healthy adults. Their average age was 25.5 years; three were female, and seven were male. On the auditory paradigm for the MMN study, the frequency of sound was 1000 Hz for the standard stimulus, and 1032 Hz for the deviant stimulus. The mean values of latency and amplitude of MMN were 202 ms and 1.88 ㎶ at Fz, 207 ms, and 1.46 ㎶ at Cz, 212 ms, and 1.10 ㎶ at C3, and 214 ms and 1.45 ㎶ at C4. There was no correlation between the latency and amplitude of MMN. This study presented the reference values of the latency and amplitude of the MMN using a standard paradigm that is easy to apply. This information may make the MMN useful for clinical applications and basic research.

Daily change and acoustical characteristics of underwater noise on a submerged sea tunnel in Jinhae Bay, Korea (진해만 침매터널 상부의 수중소음의 일변화 및 음향적 특성)

  • SHIN, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.3
    • /
    • pp.461-473
    • /
    • 2015
  • Jinhae Bay located in the southern of Korean Peninsular is an important spawning area in Korea. By some preliminary studies it was measured several times that adult Pacific codes (Gadus microcephalus) were passed (swimming layer: 15 to 18 m) over a submerged sea tunnel (sea bottom: about 30 m) rather than another immigration route when the Pacific codes were tagged surgically with an acoustic transmitters and released inside of the Bay. There is a possibility that the Pacific codes and the other fishes use the route on the sea tunnel as an immigration route are affected by a human-generated underwater noise around the sea tunnel due to the sea tunnel traffic. On this study the 25-hour measurements of the underwater noise level by water layer were conducted with a hydrophone attached on a portable CTD and an underwater noise level meter during four seasons, and the acoustical characteristics of the underwater noise was analyzed. The mean traffic volume for one hour at the sea tunnel on the spring was shown the largest value of 1,408 [standard deviation (SD): 855] vehicles among four seasons measurement. The next one was ordered on the autumn [1,145 (SD: 764)], winter [947 (SD: 598)] and summer [931 (SD: 558)] vehicles. Small size vehicle was formed 84.3% of the traffic volume, and ultra-small size, medium size, large size and extra-large size of the vehicle were taken possession of 8.7%, 3.2%, 2.0% and 1.8%, respectively. On the daily change of the noise level in vertical during four seasons the noise level of 5 m-layer was shown the highest value of 121.2 (SD: 3.6) dB (re $1{\mu}Pa$), the next one was 10 m-layer [120.7 (SD: 3.5)], 2 m- and 15 m-layer [120.3 (SD: 3.5 to 3.7)] and 1 m-layer [119.2 (SD: 3.6)] dB (re $1{\mu}Pa$). In relation with the seasonal change of the noise level the average noise level measured during autumn was shown the highest value of 123.9 (SD: 2.6) dB (re $1{\mu}Pa$), the next was during summer [121.4 (SD: 3.2)], spring [118.0 (SD: 3.4)] and winter [116.5 (SD: 5.1)] dB (re $1{\mu}Pa$). In results of eigenray computation when the real bathymetry data (complicate shape of sea bed) was applied the average number of eigenray was 2.68 times (eigenrays: 11.03 rays) higher than those of model bathymetry (flat and slightly sloped sea bottom). When the real bathymetric data toward inside (water depth becomes shallow according to a distance between the source of noise and hydrophone) of the Bay was applied on the eigenrays calculation the number of the eigenray was 1.31 times (eigenrays: 12.49 rays) larger than the real bathymetric data toward outside (water depth becomes deep with respect to the distance). But when the model bathymetric data toward inside of the Bay was applied the number of the eigenray was 1.05 times (eigenrays: 4.21 rays) larger than the model bathymetric data toward outside.

Estimation of the Characteristics of Delayed Failure and Long-term Strength of Granite by Brazilian Disc Test (압열인장시험을 이용한 화강암의 지연파괴특성 및 장기안정성 평가)

  • Jung, Yong-Bok;Cheon, Dae-Sung;Park, Eui-Seob;Park, Chan;Lee, Yun-Su;Park, Chul-Whan;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.24 no.1
    • /
    • pp.67-80
    • /
    • 2014
  • Long-term stability and delayed failure of granite were evaluated through the laboratory test based on Wilkins method and Brazilian disc test (BDT) which yields tensile strength, mode I fracture toughness and subcritical crack growth parameters. Then, the long-term strength of granite was estimated by using analytical models and long-term stability of compressed air-energy storage (CAES) pilot cavern pressurized up to 5 ~ 6 MPa was evaluated using numerical code, FRACOD with the determined subcritical crack growth parameters. The results of test and analyses showed that the subcritical crack growth index, n was determined as 29.39 and the inner pressure of 5 ~ 6 MPa had an insignificant effect on the long-term stability of pilot cavern. It was also found that the measurement and analysis of acoustic emission events can describe the accumulation of damage due to subcritical crack growth quantitatively. That is, AE monitoring can provide the current status of rock under loading if we make an identical installation condition in the field with that of the laboratory test.

Measurement of transmitted vibration to stapes and tympanic membrane by DFMT's vibration in implantable middle ear hearing devices (중이 이식형 보청기에서 DFMT의 진동에 의한 등골 및 고막 방향으로 전달되는 진동력 측정)

  • Lee, Myoung-Won;Seong, Ki-Woong;Lim, Hyung-Gyu;Kim, Min-Woo;Jung, Eui-Sung;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Lee, Sang-Heun;Lee, Kyu-Yup;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.286-293
    • /
    • 2009
  • The implantable middle ear hearing devices(IMEHDs) have been developed to overcome the conventional hearing aid's problem(ringing effect caused by the acoustic feedback, cosmetic problem, etc.). In the IMEHDs, the vibrating transducer is a key component because its vibration enables to hear for hearing impaired people. The vibrating transducer is implanted on ossicular chain by surgical operation. The coupling status between implanted transducer and ossicular chain has an effect on delivering vibrating force from transducer to stapes. Noninvasive method is required to investigate the output characteristics of IMEHDs after implementation. Recently, emitted sound pressure measuring method of tympanic membrane is proposed to investigate the output characteristics of IMEHDs. However, the relationship between displacement of stapes and sound pressure by tympanic membrane was not cleared. In this paper, displacement of stapes and sound pressure by tympanic membrane were measured using the differential floating mass transducer(DFMT) that implanted on the ossicular chain of the human temporal bone and physical ear model. Through the experiments results, the relationship between displacement of stapes and sound pressure by tympanic membrane was investigated.