• Title/Summary/Keyword: Acoustic Measurement

Search Result 896, Processing Time 0.03 seconds

In-situ Stress Measurement Using AE and DRA (AE와 DRA를 이용한 초기응력의 측정에 관한 연구)

  • Park, Pae-Han;Jeon, Seok-Won;Kim, Yang-Kyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.3 no.1
    • /
    • pp.51-62
    • /
    • 2001
  • In-situ stress measurement using AE (Acoustic Emission) and DRA (Deformation Rate Analysis) is usually carried out under uniaxial loading in the laboratory and it consumes delay time from drilling to testing. Therefore, it should be considered how the lateral stress and delay time influence on the test results for the in-situ stress determination. As the delay time increased, the accuracy of estimating the pre-stress decreased. The pre-stress of the specimen loaded only axially was determined within an error of less than 9% (using AE) and 4% (using DRA). And the specimen on which axial pre-stress and the confining pressure were loaded had an error of less than 17% (using AE) and 14% (using DRA). The results of AE and DRA for field specimens were very similar with each other but smaller than those of hydraulic fracturing method.

  • PDF

Influence of Resin-Infiltrated Time on Wood Natural Materials Using Conventional/Air-Coupled Ultrasound Waves

  • Park, Je-Woong;Kim, Do-Jung;Kweon, Young-Sub;Im, Kwang-Hee;Hsu, David K.;Kim, Sun-Kyu;Yang, In-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.235-241
    • /
    • 2009
  • Composite wood materials are very sensitive to water and inspection without any coupling medium of a liquid is really needed to wood materials due to the permeation of coupling medium such as water. However, air-coupled ultrasound has obvious advantages over water-coupled experimentation compared with conventional C-scanner. In this work, it is desirable to perform contact-less nondestructive evaluation to assess wood material homogeneity. A wood material was nondestructively characterized with non-contact and contact modes to measure ultrasonic velocity using automated data acquisition software. We have utilized a proposed peak-delay measurement method. Also through transmission mode was performed because of the main limitation for air-coupled transducers, which is the acoustic impedance mismatch between most materials and air. The variation of ultrasonic velocity was found to be somewhat difference due to air-coupled limitations over conventional scan images. However, conventional C-scan images are well agreed with increasing the resin-infiltrated time as expected. Finally, we have developed a measurement system of an ultrasonic velocity based on data acquisition software for obtaining ultrasonic quantitative data for correlation with C-scan images.

Discharge Measurement by Ultrasonic Discharge Measurement System (초음파 유량측정 시스템에 의한 유량측정)

  • Kim, Chi Young;Yoon, Gwang Suk;Kim, Dong Gu;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1198-1202
    • /
    • 2004
  • 초음파를 이용한 측정은 하천의 반대편에 흐름방향에 경사지게 초음파를 발사하여 다시 반사되어 오는 시간차를 기록함으로써 주어진 길이에서 유속을 연속적으로 측정하는 것이다. 하류로 내려가는 음파는 음향 측선(acoustic path)과 평행한 유속 성분 때문에 상류로 올라가는 음파보다 빠른 속도를 가진다. 탄천 및 괴산댐에 초음파 유량 측정시스템을 시험 설치하고 운영 결과를 검토하였다. 시험적용결과 연속적인 유량자료 획득이 가능하였으며, 기존 유속면적법 대비 $4.21\%$의 상대오차를 지니고 있어 기존 방법과 비교적 일치하는 측정결과를 나타냈다. 또한 지표유속(Index Velocity)를 활용한 단일회선 유량산정법을 검토한 결과, 다회선에 의해 운영한 결과와 평균 $2.9\%$의 상대오차를 지니고 있었다. 이 방법은 조석구간 및 배수영향을 받는 구간에서 작은 비용으로 연속유량자료를 획득할 수 있는 방법으로 판단된다. 시험적용 결과 개선해야 할 사항으로는 안정적인 자료 획득을 위한 초음파 변환기의 개선, 자료의 필터링 기술의 정밀화, 그리고 유량산정 방법에서 정확도 향상 기술 개발 등이 도출되었다. 초음파 유량 측정시스템은 자료의 연속성을 확보할 수 있는 점에서 매우 중요한 의미를 지니고 있다. 지금까지의 연속 유량 산출법은 연속적인 수위를 측정하고 각 수위에 따른 유량 측정 후 수위-유량관계를 통하여 연속적인 유량을 산출하였다. 그러나 초음파 유량 측정 시스템은 직접 유속과 수위를 측정하여 연속유량이 산출되기 때문에 연속유량 산출에 비교적 간편하다고 할 수 있다. 또한 정확도 면에서 기존 유량 측정법인 유속-면적법의 불확실도 $5\%\~10\%$에 비교하여 $5\%$ 내외의 정확도 수준을 지니고 있어 정확도 향상을 기대할 수 있다. 경제적인 측면에서도 매년 측정사업에 소요되는 비용과 비교하였을 때 장기적으로는 경제적인 방법이 될 수 있다.

  • PDF

A Thronging Response of the Shoal of Rudder Fish , Seriola Dumerili ( Risso ) to Audible Underwater Sound (수중 가청음에 대한 잿방어 어군의 유집 반응)

  • 이창헌
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.4
    • /
    • pp.285-289
    • /
    • 1997
  • A Held experiment was carried out to confirm the effect of underwater sound on the luring of fish school of rudder fish in a set net at the coast of Cheju Island. The effects of the acoustic emission on the luring of fish school were observed at a cage around a set net fishing ground using a manufactured underwater speaker. Underwater sounds that were emitted for the luring of fish school were the pure sounds of which frequency were 300Hz and 400Hz, engine noise and swimming sound. The results of the observation are as follows : 1. The input and output wave forms of a manufactured underwater speaker in water tank were similar to those in measurement frequencies. The result of the observation indicated that it could be used for the purpose of the sound emission in measurement frequencies. 2. The effect of the emitted pure sound of 300Hz, 400Hz was remarkable for the luring of fish school in 2 minutes after the sound emission. The reaction of fish school was more sensitive to the pure sound of 400Hz than 300Hz. 3. The effect of the emitted engine noise was more remarkable than that of the pure sound for 3 minute continuously. On the feeding sound, fish formed a shoal and swimmed, but didn't gather around the underwater speaker. 4. The feeding and swimming sound spectra on rudder Hsh showed similar sound pressure distribution each other, they appeared low sound pressure in frequencies of 200-600Hz.

  • PDF

Enhancement Technique of Discharge Measurement Accuracy Using Kalesto Based on Index Velocity Method in Mountain Stream, Jeju Island (지표유속법 기반 제주 산지형 하천 Kalesto 유량 정확도 향상 기법)

  • Kim, Dong-Su;Yang, Sung-Kee;Kim, Soo-Jeong;Lee, Jun-Ho
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.371-381
    • /
    • 2015
  • In the mountain streams in Jeju Island, strong turbulence and roughness usually made it nearly impossible to utilize most of intrusive instrumentation for streamflow discharge measurements. Instead, a non-intrusive fixed electro-magnetic wave surface velocimetry (fixed EWSV: Kalesto) became alternatively popular in many representative streams to measure stream discharge seamlessly. Currently, Kalesto has shown noteworthy performance with little loss in flood discharge measurements and also has successfully provided discharge for every minute. However, Kalesto has been operated to regard its measured one-point velocity as the representative mean velocity for the given cross-section. Therefore, it could be highly possible to potentially encompass discharge measurements errors. In this study, we analyzed the difference between such Kalesto discharge measurements and other alternative concurrent discharge measurements such as Acoustic Doppler Current Profiler (ADCP) and mobile EWSV which were able to measure velocity in multi-points in the cross-section. Consequently, Kalesto discharge deviated from ADCP discharge in amount of 48% for relatively low flow, and more than 20% difference for high flow compared with mobile EWSV discharge measurements. These results indicated that the one-point velocity measured by Kalesto should be used as a cross-sectional mean velocity, rather it should be accounted for as an index-velocity in conjunction with directly measured cross-sectional mean velocity by using more reliable instrumentations. After inducing Kalesto Discharge Correction Coefficient (KDCC) that actually means relationship between index velocity and cross-sectional mean velocity, the corrected discharge from Kalesto was significantly improved. Therefore, we found that index velocity method should be applied to obtain better accuracy of discharge measurement in case of Kalesto operation.

Analysis on the Correlation Coefficient for the Diversity Technique Combined with Beamforming Using Measurement Data in Underwater Channel Environments (수중 채널 환경에서 측정 데이터를 이용한 빔형성기가 결합된 다이버시티의 상관 계수 분석)

  • Kim, Min-Sang;Cho, Dae-Young;Park, Jong-Won;Lim, Yong-Kon;Ko, Hak-Lim
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.12
    • /
    • pp.1023-1030
    • /
    • 2012
  • The diversity techniques can benefit underwater acoustic communications when the distance between sensors is sufficiently apart, and this leads to the increases in the physical size of the communication system: thus it is very hard to practically use such systems in real-environments. Therefore, in this paper, we have collected data from real underwater cannel environments in order to analyze the usability of diversity combined with beamforming techniques. And we have estimated the fading characteristics from the measurement data, and analyzed the correlation coefficients using the estimated fading characteristics. After analyzing the estimated fading characteristics from the measurements data, we found out that by applying diversity techniques on the output signals from beamformers that perform beamforming from different multipath directions, we can reduce the distance between sensors and at the same time benefit from the diversity gain.

A Study on The Range Estimation of Underwater Acoustic Source using FDOA and TDOA of Multipath Signals (다중경로 신호의 도달 주파수와 시간 차를 이용한 수중음원 거리 추정 연구)

  • Son, Yoon-Jun;Son, Gi-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.311-318
    • /
    • 2021
  • Underwater, signals are transmitted by sound waves. Sound waves are transmitted through a multipath, either directly or through reflection, due to the variety of underwater environmental characteristics. In such diverse and complex underwater environments, tests must be conducted to determine the extent of the hazard from the survivability and pitfalls of submarines by measuring the underwater radiated noise. Usually, the sound source level measurement of underwater radiated noise should be made within the closest point (CPA: Closest Point of Approach) ± a few meters between the measurement sensor and the submarine. In this study, FDOA and TDOA methods were proposed to estimate the underwater source range. A simulation based on the underwater channel model confirmed the performance of the proposed method.

Development of Smart Active Layer Sensor (II): Manufacturing and Application (스마트 능동 레이어 센서 개발 (II): 저작 및 적용 연구)

  • Lee, Young-Sup;Lee, Sang-Il;Kwon, Jae-Hwa;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.5
    • /
    • pp.476-486
    • /
    • 2004
  • This paper is the second part of the study on the development of a smart active layer (SAL) sensor, which consists of two parts. As mentioned in the first paper, structural health monitoring (SHM) is a new technology that is being increasingly applied at the industrial field as a potential approach to improve cost and convenience of structural inspection. Recently, the development of smart sensor is very active for real application. This study has focused on preparation and application study of SAL sensor which is described with regard to the theory and concept of the SAL sensor in the first paper. In order to detect elastic wave, smart piezoelectric sensor, SAL, is fabricated by using a piezoelectric element, shielding layer and protection layer. This protection layer plays an important role in a patched network of distributed piezoelectric sensor and shielding treatment. Four types of SAL sensor are designed/prepared/tested, and these details will be discussed in the paper In this study, SAL sensor ran be feasibly applied to perform structural health monitoring and to detect damage sources which result in elastic waves.

Development of an EMAT System for Detecting flaws in Pipeline (배관결함 검출을 위한 EMAT 시스템 개발)

  • Ahn, Bong-Young;Kim, Young-Joo;Kim, Young-Gil;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.15-21
    • /
    • 2004
  • It is possible to detect flaws in pipelines without interruption using all EMAT transducer because it is a non-contact transducer which can transmit ultrasonic waves into specimens without couplant. And it ran easily generate guided waves desired in each specific problem by altering the design of coil and magnet. In the present work, EMAT systems have been fabricated to generate surface waves, and selectively the plate wave of $A_1\;or\;S_1$ mode. The surface wave of 1.5MHz showed a good signal-to-noise ratio without distortion in its propagation along a pipeline, while the $S_1$ mode of 800kHz and the $A_1$ mode of 940kHz were distorted according to their dispersive properties. The wider the excitation pulse becomes, the better the mode selectivity of the plate waves becomes. A pipe of 256mm inner diameter and 5.5m thickness with 5 flaws was used for comparing the flaw detectability among the modes under consideration.

Characteization of Space Charge Distribution and Conduction Current in Dielectric material With Temperature (온도에 따른 유전체내에서의 공간전하 분포와 전도전류 특성)

  • Kim, Jin-Kyun;HwangBo, Seung;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1078-1080
    • /
    • 1995
  • The pulsed electro-acoustic method was used as a nondestructive measurement technique of spare charge distribution in dielectric materials. In our work presented here, we measured simultaneously the space charge distribution and conduction current in the low-density polyethylene samples with elevated temperatures up to $80^{\circ}C$ and electric field up to 20kV/mm. In the temperature less than $50^{\circ}C$, homocharges are mainly accumulated close to the electrodes under DC bias and after grounding. At the temperature exeeds $50^{\circ}C$, heterocharges are accumulated near the opposite electrode under DC bias. However after grounding the upper electrode, this charges immediately disappeared. The conduction current in LDPE at $20^{\circ}C$ and $30^{\circ}C$ was reduced slowly with increasing interval of applied voltage. But as temperature increased, the conduction current tended to increase slowly with the time and the degree of increase is enlarged.

  • PDF