• Title/Summary/Keyword: Acidity, Measurement

Search Result 87, Processing Time 0.023 seconds

THE NONDESTRUCTIVE MEASUREMENT OF THE SOLUBLE SOLID AND ACID CONTENTS OF INTACT PEACH USING VIS/NIR TRANSMITTANCE SPECTRA

  • Hwang, I.G.;Noh, S.H.;Lee, H.Y.;Yang, S.B.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.210-218
    • /
    • 2000
  • Since the SSC(soluble solid contents) and titratable acidity of fruit are highly concerned to the taste, the need for measuring them by non-destructive technology such as NIR(Visual and Near-infrared) spectroscopy is increasing. Specially, in order to grade the quality of each fruit with a sorter at sorting and packing facilities, technologies for online measurement satisfying the tolerance in terms of accuracy and speed should be developed. Many researches have been done to develop devices to measure the internal qualities of fruit such as SSC, titratable acidity, firmness, etc. with the VIS(Visual)/NIR(Near Infrared) reflectance spectra. The distributions of the SSC, titratable acidity, firmness, etc. are different with respect to the position and depth of fruit, and generally the VIS/NIR light can interact with fruit in a few millimeters of pathlength, and it is very difficult to measure the qualities of inner flesh of fruit. Therefore, to measure the average concentrations of each quality factor such as SSC and titratable acidity with the reflectance-type NIR devices, the spectra of fruit at several positions should be measured. Recently, the interest about the transmittance-type VIS/NIR devices is increasing. NIR light can penetrate through the fruit about 1/10-1/1,000,000 %. Therefore, very intensive light source and very sensitive sensor should be adopted to measure the transmitted light spectra of intact fruit. The ultimate purpose of this study was to develop a device to measure the transmitted light spectra of intact fruit such as apple, pear, peach, etc. With the transmittance-type VIS/NIR device, the feasibility of measurement of the SSC and titratable acidity in intact fruit cultivated in Korea was tested. The results are summarized as follows; A simple measurement device which can measure the transmitted light spectra of intact fruit was constructed with sample holder, two 500W-tungsten halogen lamps, a real-time spectrometer having a very sensitive CCD array sensor and optical fiber probe. With the device, it was possible to measure the transmitted light spectra of intact fruit such as apple, pear and peach. Main factors affecting the intensity of transmitted light spectra were the size of sample, the radiation intensity of light source and the integration time of the detector. Sample holder should be designed so that direct light leakage to the probe could be protected. Preprocessing method to the raw spectrum data significantly influenced the performance of the nondestructive measurement of SSC and titratable acidity of intact fruit. Representative results of PLS models in predicting the SSC of peach were SEP of 0.558 Brix% and R2 of 0.819, and those in predicting titratable acidity were SEP of 0.056% and R2 of 0.655.

  • PDF

The application of a nondestructive method to measure the acidity of Korean papers (한지의 산성도 측정을 위한 비파괴적 방법의 적용)

  • Lee, Hye-Yun;Chung, Yong-Jae;Lee, Kyu-Sik;Han, Sung-Hee
    • 보존과학연구
    • /
    • s.20
    • /
    • pp.21-47
    • /
    • 1999
  • According to damage of papers by the chemical cause, papers become to acidify. Among the 3 kinds of method measuring the acidity of paper, one was nondestructive method measuring the surface of the paper by flat type electrode and the others were destructive methods measuring directly by cold water extract method and hot water extract method. In case of the cellulolytic cultural properties, the latter methods were not applied because those methods must bedissociated papers. To measure the paper acidity nondestructively, we investigated the correlation of the nondestructive method and the destructive methods. The conclusions are as follows. 1) In the relationship of the cold water extract method and the hot water extract method, It was indicated that the pH measured by the hot water extract method was high quality printing paper 0.08, rough printing paper 0.13, and Korean paper 0.29 higher than that by the cold water extract method.2) In the relationship of the cold water extract method and the surface measurement method, It showed that the pH value measured by the cold water extract method was high quality printing paper 1.86, rough printing paper 0.80,and Korean paper 0.58 higher than value that by the surface measurement.3) In the relationship of the hot water extract method and the surface measurement method, It showed that the pH value measured by the hot ABSTRACT water extract method was high quality printing paper 1.78, rough printing paper 0.66, and Korean paper 0.29 higher than that by the surface measurement. From the above-mentioned results, the pH value measured by the surface measurement was need to high about 1.78∼1.86 in high quality printing paper, 0.66-0.80 in rough printing paper, and 0.29∼0.58 in Korean paper and the surface measurement with flat type electrode was very available to measure the acidity of Korean papers actually.

  • PDF

Effects of Rain Water Sampler on the Results of Analysis (雨水採取機가 雨水成分에 미치는 影響)

  • 李敏熙;韓義正;辛燦基;韓振錫
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.3 no.2
    • /
    • pp.53-61
    • /
    • 1987
  • Automatic and manual rain smaplers wre installed at the roof of National Institute of Environmental Research (NIER), and the rain sampling and measurement were conducted during the period April to August 31, 1987. The rain sampling and measurement were carried out in the following manners: The 1st : Acidity and conductivity were measured entirely by automatic rain sampler (continuous measurement) The 2nd : Acidity and conductivity wrer measured in the laboratory with the sample that was taken out of automatic rain sampler. The 3rd : Acidity and conductivity were measured in the laboratory with the sample that was taken out of manual rain sampler. Afterwards, those different measurement values were compared each other and the following conclusions were obtained: 1) The pH of the continous measurement by the automatic sampler was lower than that of the laboratory measurement, and it was reversed in case of the conductivity. 2) The significance was recognized at 5% risk ratio for the population mean of difference of the measurement values of the pH and conductivity from both samples. 3) The significance was not recognized at 5% risk ratio by the analysis of variance by one way layout for the pH and conductivity. 4) The significance was recognized at 5% risk ratio by the analysis of variance by two way layouts for the pH conductivity. 5) The significance was recognized at 5% rrisk ratio for the differences of the pH values obtained by oboth samplers, and no significance was recognized for conductivity. 6) In comparison of the measurement values from the two samplers were shown a good correlation for pH; correlation coefficient (r) = 0.63, and regression equation Y = 0.53X + 2.78. For conductivity, the correlation was also excellent; correlation coefficient (r) = 0.53 and regression equation Y = 0.63X + 5.65.

  • PDF

On-site conservation of a gilt bronze crown (발굴현장 수습 유물 보존처리)

  • Yu, Jae-Eun
    • 보존과학연구
    • /
    • s.20
    • /
    • pp.49-64
    • /
    • 1999
  • According to damage of papers by the chemical cause, papers become to acidify. Among the 3 kinds of method measuring the acidity of paper, one was nondestructive method measuring the surface of the paper by flat type electrode and the others were destructive methods measuring directly by cold water extract method and hot water extract method. In case of the cellulolytic cultural properties, the latter methods were not applied because those methods must bedissociated papers. To measure the paper acidity nondestructively, we investigated the correlation of the nondestructive method and the destructive methods. The conclusions are as follows. 1) In the relationship of the cold water extract method and the hot water extract method, It was indicated that the pH measured by the hot water extract method was high quality printing paper 0.08, rough printing paper 0.13, and Korean paper 0.29 higher than that by the cold water extract method.2) In the relationship of the cold water extract method and the surface measurement method, It showed that the pH value measured by the cold water extract method was high quality printing paper 1.86, rough printing paper 0.80,and Korean paper 0.58 higher than value that by the surface measurement.3) In the relationship of the hot water extract method and the surface measurement method, It showed that the pH value measured by the hot ABSTRACT water extract method was high quality printing paper 1.78, rough printing paper 0.66, and Korean paper 0.29 higher than that by the surface measurement. From the above-mentioned results, the pH value measured by the surface measurement was need to high about 1.78∼1.86 in high quality printing paper, 0.66-0.80 in rough printing paper, and 0.29∼0.58 in Korean paper and the surface measurement with flat type electrode was very available to measure the acidity of Korean papers actually.

  • PDF

AN EXPERIMENTAL STUDY ON THE MEASUREMENT OF THE INITIAL ACIDITY OF DENTAL CEMENTS (수종 치과용 시멘트 경화시 초기 산도측정에 관한 실험적 연구)

  • Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.189-196
    • /
    • 1991
  • The purpose of this study was to observe the inital acidity of zinc phosphate cements(Confit and Super Cem), poly carboxylate cement(Unident and Poly F), zinc oxide engenol cement(Stailine Super EBA) and g1ass ionomer cement(Fuji ionomer) Each cement was manuplated in accordance with each manufacturer's direction. All cements were mixed at the room temperature of $23^{\circ}{\pm}$, $5^{\circ}C$, and the electrode of pH meter(Ionanalyzer) was inserted in the mixed cement, and the acidity of cement were measured for 20 minutes from begining of cement mixing at $23^{\circ}C$ and $37^{\circ}C$ Results were as follows 1. The acidity of all cements ranges from pH 3, 5 to 4, 5 at 2 minutes after the start of mixing 2. The value of pH at $23^{\circ}C$ was higher than the value of pH at $37^{\circ}C$ in all cements. 3. As the time elapsed, the pH in all cements rose. The 20 minutes after the start of mixing the range of acidity was from pH 5 to pH 6 except Poly F. 4. In polycarboxylate cement, the different value of acidity at $23^{\circ}C$ and $37^{\circ}C$ was greatest. 5. The curve pattern of acidity in Unident was similar to that in Poly F cement The pH value of Unident was higher then that of Poly F, and value of pH in the curve pattern of acidity in Confit were similar to those in Super cement.

  • PDF

Evaluation of the Reliability of Salivary Testing Instrument (타액검사기의 신뢰도 평가)

  • Han, Keumah;Lee, Joonhaeng
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.3
    • /
    • pp.363-369
    • /
    • 2018
  • A salivary testing instrument has an advantage that the method is simple and can be performed in a short time. However, it is necessary to verify the factors that affect the reliability of the result, because the device is easy to use and even saliva collection is simple. The aim of this study was to compare the difference of the test results according to the measurement time in order to analyze the time factor of the external variable among the factors that may affect the measurement results of the salivary testing instrument. The relationship between the measured values of the salivary testing instrument to identify the internal variables was analyzed. Saliva was collected from 20 randomly selected patients regardless of age, sex, or diseases. The mean age was 46.6 years, 10 males and 10 females. The saliva collected was directly measured with the salivary testing instrument as group I. The saliva samples were placed in air in a paper cup for 10 minutes, and then measured as group III. Then group I was remeasured after 30 minutes and assigned as group II. Group III was remeasured after 30 minutes and called as group IV. As a result, all of the cariogenic bacteria, acidity, buffer capacity, blood, leukocyte, protein and ammonia, except buffer capacity, showed statistically significant changes in group II and IV. This means that the reliability of the test results is poor if the measurement time is not observed. Cariogenic bacteria were correlated with leukocyte and protein, buffer capacity was related to acidity, protein, and protein was related to buffer capacity and leukocyte. In conclusion, the result according to the measurement time as the external variable was different, which means that time must be strictly monitored when testing saliva. It is also necessary to take into account the relevance of the correlations between the internal variables and the clinical data.

Measurement of Aerosol Acidity ($H^+$) in Ambient Air (대기중의 산성도(H+) 측정)

  • 이학성
    • Journal of Environmental Science International
    • /
    • v.4 no.1
    • /
    • pp.53-62
    • /
    • 1995
  • To collect and evaluate an aerosol acidity ($H^+$) in ambient air, the cyclone/annular denuder/filter pack sampling system (ADS) was used. Aerosol acidity was collected in Chicago using the ADS for 81 12-hr samples divided in spring/summer/fall 1990 and winter 1991. This study illustrated that the ADS was suitable for measuring aerosol acidity. The $10^{-5}N$ $HCIO_4$ extraction solution for pH determination provided more reliable scale than $10^{-4}N$ HClO4. NH3 should be removed prior to particle collection to accurately measure $H^+$ concentration on the filter. There was seasonal variation in aerosol acidity concertrations. Aerosols were more acidic in the summer. High correlations between $SO_4^{2+} and$NH_4^+$, and between TEX>$SO_4^{2+}$H^+$ were observed during the entire sampling period.

  • PDF

A Study on High-acidity Rubus coreanus Concentrated Vinegar Production Using Freeze Concentration Method (동결농축법을 이용한 고산도 복분자 농축식초 제조에 관한 연구)

  • Sung, Ji-Youn;Lee, Ikheui
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.11
    • /
    • pp.419-426
    • /
    • 2021
  • Until recently, various studies for the production of high-acidity vinegar have been conducted, but there have been few studies on the concentration process of vinegar. In this study, the possibility of introducing freeze-concentration method was investigated for the production of high-quality, high-acidity vinegar. Acidity, pH, specific gravity, and glucose concentration were measured for frozen concentrated vinegar fractions obtained by freezing and thawing three types of Rubus coreanus vinegar with different acidy (7.53, 5.43, and 3.72). Acidity, specific gravity, and glucose concentration were all highest when 15% of the original vinegar was thawed. pH was the lowest when 15% of the original vinegar was melted. As a result of the measurement of cumulative acidity, when 20% of the original vinegar was melted, it was the highest at 9.32, which was 3.89 higher than that of the original vinegar. In this study, it was confirmed that vinegar can be effectively concentrated using the freeze concentration method and at the same time, the thawing ratio can be controlled to effectively obtain vinegar with the desired acidity. However, it is considered that studies such as organic acid and amino acid analysis are needed to determine whether the freeze-concentration method is introduced into the high-acidity concentrated vinegar manufacturing process.

Study on Prediction of Internal Quality of Cherry Tomato using Vis/NIR Spectroscopy (가시광 및 근적외선 분광기법을 이용한 방울토마토의 내부품질 예측에 관한 연구)

  • Kim, Dae-Yong;Cho, Byoung-Kwan;Mo, Chang-Yeun;Kim, Young-Sik
    • Journal of Biosystems Engineering
    • /
    • v.35 no.6
    • /
    • pp.450-457
    • /
    • 2010
  • Although cherry tomato is one of major vegetables consumed in fresh vegetable market, the quality grading method is mostly dependant on size measurement using drum shape sorting machines. Using Visible/Near-infrared spectroscopy, apparatus to be able to acquire transmittance spectrum data was made and used to estimate firmness, sugar content, and acidity of cherry tomatoes grown at hydroponic and soil culture. Partial least square (PLS) models were performed to predict firmness, sugar content, and acidity for the acquired transmittance spectra. To enhance accuracy of the PLS models, several preprocessing methods were carried out, such as normalization, multiplicative scatter correction (MSC), standard normal variate (SNV), and derivatives, etc. The coefficient of determination ($R^2_p$) and standard error of prediction (SEP) for the prediction of firmness, sugar, and acidity of cherry tomatoes from green to red ripening stages were 0.859 and 1.899 kgf, with a preprocessing of normalization, 0.790 and $0.434^{\circ}Brix$ with a preprocessing of the 1st derivative of Savitzky Golay, and 0.518 and 0.229% with a preprocessing normalization, respectively.

A Modeling Study on Aerosol Property Changes due to Sea-Salts (해염성분에 의한 에어로솔 물성변화 모사연구)

  • 김용표
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.113-120
    • /
    • 2000
  • Effects of sea-salts on the properties of aerosol collected in a coastal region were studied by applying a gas-particle equilibrium model SCAPE to the measurement data from Korea Cheju Island in summer 1994. It was found that the observed higher ammonium concentrations in fine particles (PM2.5) than in TSP were caused by forced evaporation of ammonium in coarse fraction of aerosol by sea-salts and the degree of evaporation was quantified through an application of SCAPE. By subtracting the sea-salt fraction from the measured concentra-tions the changes of aerosol property were also studied. The concentrations of nitrate at both TSP and PM2.5 decreased when alkaline sea-salt fraction was removed from the measured data. Estimates of aerosol acidity increased for most samples with sea salt loadings, However in some cases with high mass fractions of sea-salt components the aerosol acidity of PM2.5 decreased slightly. This is though to be related with the formation of solid salt with the removal of sea-salts.

  • PDF