• 제목/요약/키워드: Accuracy test

검색결과 4,894건 처리시간 0.036초

Evaluation of the Accuracy of Grounding Impedance Measurement of Grounding Grid (접지그리드의 접지임피던스 측정의 정확도 평가)

  • Choi, Jong-Hyuk;Choi, Young-Chul;Jeong, Dong-Cheol;Kim, Dong-Seong;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제23권12호
    • /
    • pp.146-153
    • /
    • 2009
  • Recently, the common grounding systems are adapted in most large structures. Since the ground resistance is insufficient to evaluate the performance of grounding systems, it is needed to measure grounding impedance. Even though the methods of measuring grounding impedance of large grounding systems are presented in IEEE standard 81.2, but they have not been described in detail. In this paper, we present the accurate method of measuring grounding impedance based on the revised fall-of-potential method and measurement errors due to earth mutual resistance and ac mutual coupling depending on locating test electrodes at remote earth were examined for the 15[m]$\times$15[m] grounding grid. As a result, the measurement error due to earth mutual resistance is decreased when the distance to auxiliary electrodes increased. To get rid of measurement errors due to mutual coupling, the potential lead should be installed at a right angle to the current lead. When the angle between the potential and the current leads is an acute angle or an obtuse angle, the mutual couple voltage is positive or negative, respectively. Generally, the measurement errors due to mutual coupling with an obtuse angle route are lower than those with an acute angle route.

Location Estimation System based on Majority Sampling Data (머저리티 샘플링 데이터 기반 위치 추정시스템)

  • Park, Geon-Yeong;Jeon, Min-Ho;Oh, Chang-Heon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제18권10호
    • /
    • pp.2523-2529
    • /
    • 2014
  • Location estimation service can be provided outdoors using various location estimation system based on GPS. However, location estimation system is based on existing indoor resources as GPS cannot be used because of insufficient visible satellites and weak signals. The fingerprinting technique that uses WLAN signal, in particular, is good to use indoors because it uses RSSI provided by AP to estimate location. However, its accuracy may vary depending on how accurate data the offline stage used where the fingerprinting map is built. The study sampled various data at the stage that builds the fingerprinting map and suggested a location estimation system that enhances its precision by saving the data of high frequency among them to improve this problem. The suggested location estimation system based on majority sampling data estimates location by filtering RSSI data of the highest frequency at the client and server to be saved at a map, building the map and measuring a similar distance. As a result of the test, the location estimation precision stood at minimum 87.5 % and maximum 90.4% with the margin of error at minimum 0.25 to 2.72m.

Analysis of PRC regeneration algorithm performance in dynamic environment by using Multi-DGPS Signal (다중 DGPS 신호를 이용한 동적 환경에서의 PRC 재생성 알고리즘 성능분석)

  • Song Bok-Sub;Oh Kyung-Ryoon;Kim Jeong-Ho
    • The KIPS Transactions:PartA
    • /
    • 제13A권4호
    • /
    • pp.335-342
    • /
    • 2006
  • As PRC linear interpolation algorithm is applied after analysed and verified in this paper, the unknown location of a user can be identified by using PRC information of multi-DGPS reference station. The PRC information of each GPS satellite is not varying rapidly, which makes it possible to assume that PRC information of each GPS satellite varies linearly. So, the PRC regeneration algorithm with linear interpolation can be applied to improve the accuracy of finding a user's location by using the various PRC information obtained from multi-DGPS reference station. The desirable PRC is made by the linear combination with the known position of multi-DGPS reference station and PRC values of a satellite using signals from multi-DGPS reference station. The RTK-GPS result was used as the reference. To test the performance of the linearly interpolated PRC regeneration algorithm, multi-channel DGPS beacon receiver was built to get a user's position more exactly by using PRC data of maritime DGPS reference station in RTCM format. At the end of this paper, the result of the quantitative analysis of the developed navigation algorithm performance is presented.

Development and Field Application of Apparatus for Determination of Limit State Design Strength Characteristics in Weathered Ground (한계상태설계법 지반정수 산정을 위한 풍화대 강도특성 측정장치의 개발 및 현장적용에 관한 연구)

  • Kim, Ki Seog;Kim, Jong Hoon;Choi, Sung-oong
    • Tunnel and Underground Space
    • /
    • 제30권2호
    • /
    • pp.164-179
    • /
    • 2020
  • Applying the limit state design method to geotechnical structures, accuracy and reliability of its design are mainly affected by parameters for geotechnical site characteristics, such as unit weight, Poisson's ratio, deformation modulus, cohesion and frictional angle. When the structures are located in weathered ground, especially, cohesion and frictional angle of ground are closely related with decision of parameters for structures' load and ground's resistance. Therefore, the accurate determination of these parameters, which are commonly obtained from field measurement, such as borehole shear test, are essential for optimum design of geotechnical structures. The 38 case studies, in this study, have been analyzed for understanding the importance of these parameters in designing the ground structures. From these results, importance of field measurement was also ascertained. With these evaluations, an apparatus for determining the strength characteristics, which are fundamental in limit state design (LSD) method, have been newly developed. This apparatus has an improved function as following the ASTM suggestion. Through the field application of this apparatus, the strong point of minimizing the possibility of error occurrence during the measurement has been verified and authors summarized that the essential parameters for LSD can be qualitatively obtained by this apparatus for determination of strength characteristics of weathered ground.

3D Finite Element Analysis of Lateral Loaded Pile using Beam and Rigid Link (빔요소와 Rigid 링크를 이용한 수평하중에 대한 말뚝 거동 3차원 유한요소해석)

  • Park, Du-Hee;Park, Jong-Bae;Kim, Sang-Yeon;Park, Yong-Boo
    • Land and Housing Review
    • /
    • 제4권3호
    • /
    • pp.271-277
    • /
    • 2013
  • The BNWF (Beam on Nonlinear Winkler Foundation) model is one of the simplest idealizations for a pile embedded in soil as it ignores the continuity of the soil. This method is difficult to model the behavior of pile group foundation subjected to lateral loading. The limitation can be overcome with the utilization of the finite element method (FEM) or finite different method (FDM) to represent a pile element embedded in a soil medium. Both the ground and piles are modeled with soild elements. The solid elements, which do not have rotational degree of freedom, is not appropriate for modeling piles. It can be overcome by substantially increasing the number of elements, which can be prohibitive for 3D modeling. This paper used the beam element and rigid link incorporated in the OpenSees to model the pile. The accuracy of the model is validated through comparison with lateral load test and BNWF analysis. It is shown that the method can capture the measured behavior accurately. It is therefore recommended to be used in group pile analyses.

Comparison of Two Commercial Antibody Enzyme-Linked Immunosorbent Assays for Detection of Porcine Reproductive Respiratory Syndrome Virus Infection (돼지생식기호흡기증후군(PRRS) 바이러스 감염 항체 검출 ELISA 상용 키트의 정확도 비교)

  • Pak, Son-Il;Lee, Seung-Hwan;Park, Kyung-Ae
    • Journal of Veterinary Clinics
    • /
    • 제33권2호
    • /
    • pp.102-106
    • /
    • 2016
  • More than 20 years after the first report of porcine reproductive and respiratory syndrome virus (PRRSV) in Korea, the disease is still having major impact on domestic pig health and relevant industries. Although ELISA tests are commonly used by veterinarians to guide herd management, data on diagnostic performance of the test in field settings are very limited. The objective of this study was to evaluate two commercially available PRRSV ELISA (IDEXX PRRS X3 ELISA and Bionote PRRSV ELISA 4.0) to detect antibodies against PRRSV on serum samples. To this end, a total of 1,108 sera were recruited from 35 swine farms located in Gyeonggi province and tested at the Gyeonggi Province Veterinary Service Center. All tests were performed according to the manufacturer's instructions, by laboratory technicians who routinely perform PRRS testing on blood samples. Samples were collected from two sources of swine populations with different PRRS prevalence; 60 samples (5.4%) were originated from breeding farms and the remaining 1,048 samples (94.6%) were from farrow-to-finish farms. We applied Bayesian latent class model (LCM) for two-tests in the two-population when the accuracy of the gold standard is not available. The model estimated that Bionote ELISA was a bit more specific but slightly less sensitive. The estimated sensitivity and specificity of the IDEXX ELISA were 99.8% (95% CI 98.1-100%) and 86.4% (95% CI 81.4-96.5%), respectively. Sensitivity, specificity, positive predictive value and negative predictive value for Bionote kit were 98.7% (95% CI 92.8-100%), 89.8% (95% CI 86.2-93.1%), 93.8% (95% CI 91.5-96.0%), and 97.8% (95% CI 87.1-100%), respectively. Based on the Bayesian 95% credible intervals, the sensitivity and specificity of the two ELISAs were not significantly different each other when assuming that two kits were imperfect, indicating that two kits performed equally well in terms of sensitivity and specificity in our filed setting.

Clinical Features of Electrogastrogram in Dyspeptic Patients with Stomach Qi Deficiency (위기허증으로 진단된 소화불량 환자의 임상적 특징; 위전도 검사를 중심으로)

  • Jeong, Hae-in;Kim, Dong-yoon;Baek, So-young;Lee, Ha-nul;Lee, Hyun-jin;Cho, Yun-jae;Ha, Na-yeon;Kim, Jin-sung
    • The Journal of Internal Korean Medicine
    • /
    • 제41권3호
    • /
    • pp.467-477
    • /
    • 2020
  • Objectives: This study investigated the cutaneous electrogastrogram (EGG) and other clinical characteristics of dyspeptic patients who have been diagnosed with Stomach Qi Deficiency (SQD) using the Scale for Stomach Qi Deficiency (SSQD). Methods: This study reviewed the clinical records of 38 patients with dyspepsia who were evaluated with SSQD and EGG at the Department of Digestive Diseases of Kyung Hee University Korean Medicine Hospital in Seoul, Korea from November 1, 2019 to February 29, 2020. We evaluated the EGG and other clinical characteristics of the SQD patients to determine if there was an association between the SSQD scores and the EGG. Results: In terms of the EGG, the SQD patients showed no significant increase in the percentage of normal slow wave after a meal and a slightly decreased power ratio at Channel 1 and Channel 2. We also found an association between the SSQD scores and the EGG parameters at Channel 1 and Channel 3. The average Ryodoraku score of the patients was 33.00±14.90 (μA). In the Heart Rate Variability (HRV) test, the average Total Power (TP) and Low Frequency/High Frequency (LF/HF)) ratio was 1356.60±13 6.41(ms2) and 1.68±2.25, respectively. Conclusions: The results of this study suggest that clinicians can use Electrogastrography to enhance accuracy when diagnosing the SQD pattern.

Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats

  • Lee, Jung-Min;Han, Young-Hwan;Choi, Su-Jeong;Park, Ju-Seong;Jang, Jeong-Jun;Bae, Re-Ji-Na;Lee, Mi Ju;Kim, Myoung Jun;Lee, Yong-Hoon;Kim, Duyeol;Lee, Hye-Young;Park, Sun-Hee;Park, Cheol-Beom;Kang, Jin Seok;Kang, Jong-Koo
    • Toxicological Research
    • /
    • 제30권4호
    • /
    • pp.305-309
    • /
    • 2014
  • Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at $20^{\circ}C$, at $4^{\circ}C$, or at $-70^{\circ}C$ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-${\beta}$-D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at $-70^{\circ}C$ (p < 0.05, p < 0.01, p < 0.05, and p < 0.05, respectively) and 24 and 144 hr at $20^{\circ}C$ (p < 0.01, p < 0.01, respectively). The Cys-C level was significantly decreased at 144 hr compared to 0 hr at $4^{\circ}C$ (p < 0.01), at $20^{\circ}C$ (p < 0.05) and at $70^{\circ}C$ (p < 0.01). MP and MA levels were not different for 144 hr in all storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers.

Determination of Free 4-hydroxyproline with Dansylchloride by HPLC in Human Urine (소변 중 4-hydroxyproline 분석에 관한 연구)

  • Lee, Keou-Weon;Cho, Young-Bong;Lee, Kyung-Jong
    • Journal of Preventive Medicine and Public Health
    • /
    • 제35권4호
    • /
    • pp.282-286
    • /
    • 2002
  • Objectives : The level of 4-hydroxyproline (4-Hyp) in human urine was measured using high performance liquid chromatography (HPLC) with a fluorescence detector. This method is useful for medical examinations and investigating the radicals induced by physical, chemical, mental stresses. This method is superior to many published several methods in terms of its low cost and ability to analyze many samples. Methods : The urine from workers in a tire manufacturing company (22 male pre- and post-shift workers) and 18 office-workers as controls were analyzed. Data concerning age, the cumulative drinking amount and the cumulative smoking amount was collected with a questionnaire. The optimum applied amount of dansyl-Cl, the optimum reaction temperature and time, the recoveries and the optimum pH of the eluent and buffer were determined.4-Hyp from human urine was derivatized with dansyl-Cl (dimethylamino-naphthalene-1-sulfonyl chloride) after removing the a-amino acid by a treatment with phthalic dicarboxaldehyde (OPA) and cleaned with Bond Elut C18 column. The 4-Hyp derivatives were separated on a reversed phase column by gradient elution with a phosphate buffer (5 mmol, pH 8.0) and acetonitrile, and detected by fluorescence measurements at 340 nm (excitation) and 538 nm (emission). Results : The detection limit for the urinary free 4-Hyp was $0.364{\mu}mol/l$. The recovery rate of 4-Hyp was 99.7%, and the effective pH of the phosphate buffer and borate buffer were 3.0 and 8.0, respectively. From statistical analysis, age, drinking and smoking did not affect the urinary free 4-Hyp in both the controls and workers. The range of urinary 4-Hyp in the controls, pre-shift, and post-shift workers were 0.33-16.44, N.D-49.06, and $0.32-56.27{\mu}mol/l$. From the pared-sample t-test, the urinary 4-Hyp levels in post-shift workers ($11.82{\pm}6.73\;nmmol/mg\;Cre$) were 2-fold higher than in pre-shift workers ($5.36{\pm}5.53\;nmol;/mg\;Cre$) and controls ($4.91{\pm}4.89\;nmol;/mg\;Cre$). Conclusions : This method was developed with high sensitivity, accuracy, and precision. The present method was effectively applied to analyze the urinary free 4-Hyp in both controls and workers.

Basic Evaluation of Analytical Performance and Clinical Utility of Immunoradiometric TSH Assay (면역방사 계수측정법 (Immunoradiometric, Assay)에 의한 혈청 TSH 측정의 기본적 검토 및 임상적 의의)

  • Suh, Kyo-Il;Cho, Bo-Youn;Lee, Hong-Kyu;Koh, Chang-Soon;Min, Hun-Ki;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • 제21권2호
    • /
    • pp.143-150
    • /
    • 1987
  • To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit $(Abott^{(R)}\;and\;Daichi^{(R)})$. Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 voluteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intra assay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/l respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU/l. Mean recoveray rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/l and 2.85-30.8 mU/l repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function.

  • PDF