Browse > Article
http://dx.doi.org/10.5487/TR.2014.30.4.305

Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats  

Lee, Jung-Min (Pathology Department, Biotoxtech Co., Ltd.)
Han, Young-Hwan (Pathology Department, Biotoxtech Co., Ltd.)
Choi, Su-Jeong (Pathology Department, Biotoxtech Co., Ltd.)
Park, Ju-Seong (Pathology Department, Biotoxtech Co., Ltd.)
Jang, Jeong-Jun (Pathology Department, Biotoxtech Co., Ltd.)
Bae, Re-Ji-Na (Pathology Department, Biotoxtech Co., Ltd.)
Lee, Mi Ju (Pathology Department, Biotoxtech Co., Ltd.)
Kim, Myoung Jun (Pathology Department, Biotoxtech Co., Ltd.)
Lee, Yong-Hoon (Pathology Department, Biotoxtech Co., Ltd.)
Kim, Duyeol (Pathology Department, Biotoxtech Co., Ltd.)
Lee, Hye-Young (Pathology Department, Biotoxtech Co., Ltd.)
Park, Sun-Hee (Pathology Department, Biotoxtech Co., Ltd.)
Park, Cheol-Beom (Pathology Department, Biotoxtech Co., Ltd.)
Kang, Jin Seok (Department of Biomedical Laboratory Science, Namseoul University)
Kang, Jong-Koo (Laboratory Animal Medicine, College of Veterinary Medicine, Chungbuk National University)
Publication Information
Toxicological Research / v.30, no.4, 2014 , pp. 305-309 More about this Journal
Abstract
Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at $20^{\circ}C$, at $4^{\circ}C$, or at $-70^{\circ}C$ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-${\beta}$-D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at $-70^{\circ}C$ (p < 0.05, p < 0.01, p < 0.05, and p < 0.05, respectively) and 24 and 144 hr at $20^{\circ}C$ (p < 0.01, p < 0.01, respectively). The Cys-C level was significantly decreased at 144 hr compared to 0 hr at $4^{\circ}C$ (p < 0.01), at $20^{\circ}C$ (p < 0.05) and at $70^{\circ}C$ (p < 0.01). MP and MA levels were not different for 144 hr in all storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers.
Keywords
Nephrotoxicity; Biomarkers; Storage temperature; Storage period; Stability;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Dieterle, F., Perentes, E., Cordier, A., Roth, D.R., Verdes, P., Grenet, O., Pantano, S., Moulin, P., Wahl, D., Mahl, A., End, P., Staedtler, F., Legay, F., Carl, K., Laurie, D., Chibout, S.D., Vonderscher, J. and Maurer, G. (2010) Urinary clusterin, cystatin C, beta2-microglobulin and total protein as markers to detect drug-induced kidney injury. Nat. Biotechnol., 28, 463-469.   DOI   ScienceOn
2 Kim, S.Y. and Moon, A. (2012) Drug-induced nephrotoxicity and its biomarkers. Biomol. Ther. (Seoul), 20, 268-272.   과학기술학회마을   DOI   ScienceOn
3 Schentag, J.J., Sutfin, T.A., Plaut, M.E. and Jusko, W.J. (1978) Early detection of aminoglycoside nephrotoxicity with urinary beta-2-microglobulin. J. Med., 9, 201-210.
4 Davey, P.G. and Gosling, P. (1982) beta 2-Microglobulin instability in pathological urine. Clin. Chem., 28, 1330-1333.
5 Herget-Rosenthal, S., Feldkamp, T., Volbracht, L. and Kribben, A. (2004) Measurement of urinary cystatin C by particleenhanced nephelometric immunoassay: precision, interferences, stability and reference range. Ann. Clin. Biochem., 41, 111-118.   DOI   ScienceOn
6 Morita, A., Numata, Y., Kosugi, Y., Noto, A., Takeuchi, N. and Uchida, K. (1998) Stabilities of N-acetyl-beta-D-glucosaminidase (NAG) isoenzymes in urine: advantage of NAG isoenzyme B measurement in clinical applications. Clin. Chim. Acta, 278, 35-43.   DOI   ScienceOn
7 Price, R.G. (1982) Urinary enzymes, nephrotoxicity and renal disease. Toxicology, 23, 99-134.   DOI   ScienceOn
8 Usuda, K., Kono, K., Dote, T., Nishiura, K., Miyata, K., Nishiura, H., Shimahara, M. and Sugimoto, K. (1998) Urinary biomarkers monitoring for experimental fluoride nephrotoxicity. Arch. Toxicol., 72, 104-109.
9 Parikh, C.R., Butrymowicz, I., Yu, A., Chinchilli, V.M., Park, M., Hsu, C.Y., Reeves, W.B., Devarajan, P., Kimmel, P.L., Siew, E.D. and Liu, K.D. (2014) Urine stability studies for novel biomarkers of acute kidney injury. Am. J. Kidney Dis., 63, 567-572.   DOI   ScienceOn
10 Mall, C., Rocke, D.M., Durbin-Johnson, B. and Weiss, R.H. (2013) Stability of miRNA in human urine supports its biomarker potential. Biomarkers Med., 7, 623-631.   DOI   ScienceOn
11 Miki, K. and Sudo, A. (1998) Effect of urine pH, storage time, and temperature on stability of catecholamines, cortisol, and creatinine. Clin. Chem., 44, 1759-1762.
12 Jung, K., Pergande, M., Schreiber, G. and Schroder, K. (1983) Stability of enzymes in urine at 37 degrees C. Clin. Chim. Acta, 131, 185-191.   DOI   ScienceOn
13 Belcher, J.M., Edelstein, C.L. and Parikh, C.R. (2011) Clinical applications of biomarkers for acute kidney injury. Am. J. Kidney Dis., 57, 930-940.   DOI   ScienceOn
14 Hoffmann, D., Fuchs, T.C., Henzler, T., Matheis, K.A., Herget, T., Dekant, W., Hewitt, P. and Mally, A. (2010) Evaluation of a urinary kidney biomarker panel in rat models of acute and subchronic nephrotoxicity. Toxicology, 277, 49-58.   DOI   ScienceOn
15 Park, M.Y., Choi, S.J., Kim, J.K., Hwang, S.D. and Lee, Y.W. (2013) Urinary cystatin C levels as a diagnostic and prognostic biomarker in patients with acute kidney injury. Nephrology (Carlton), 18, 256-262.   DOI   ScienceOn
16 Vaidya, V.S., Waikar, S.S., Ferguson, M.A., Collings, F.B., Sunderland, K., Gioules, C., Bradwin, G., Matsouaka, R., Betensky, R.A., Curhan, G.C. and Bonventre, J.V. (2008) Urinary biomarkers for sensitive and specific detection of acute kidney injury in humans. Clin. Transl. Sci., 1, 200-208.   DOI   ScienceOn
17 Waikar, S.S. and Bonventre, J.V. (2008) Biomarkers for the diagnosis of acute kidney injury. Nephron Clin. Pract., 109, c192-197.   DOI   ScienceOn
18 Ozer, J.S., Dieterle, F., Troth, S., Perentes, E., Cordier, A., Verdes, P., Staedtler, F., Mahl, A., Grenet, O., Roth, D.R., Wahl, D., Legay, F., Holder, D., Erdos, Z., Vlasakova, K., Jin, H., Yu, Y., Muniappa, N., Forest, T., Clouse, H.K., Reynolds, S., Bailey, W.J., Thudium, D.T., Topper, M.J., Skopek, T.R., Sina, J.F., Glaab, W.E., Vonderscher, J., Maurer, G., Chibout, S.D., Sistare, F.D. and Gerhold, D.L. (2010) A panel of urinary biomarkers to monitor reversibility of renal injury and a serum marker with improved potential to assess renal function. Nat. Biotechnol., 28, 486-494.   DOI   ScienceOn
19 Dieterle, F., Sistare, F., Goodsaid, F., Papaluca, M., Ozer, J.S., Webb, C.P., Baer, W., Senagore, A., Schipper, M.J., Vonderscher, J., Sultana, S., Gerhold, D.L., Phillips, J.A., Maurer, G., Carl, K., Laurie, D., Harpur, E., Sonee, M., Ennulat, D., Holder, D., Andrews-Cleavenger, D., Gu, Y.Z., Thompson, K.L., Goering, P.L., Vidal, J.M., Abadie, E., Maciulaitis, R., Jacobson-Kram, D., Defelice, A.F., Hausner, E.A., Blank, M., Thompson, A., Harlow, P., Throckmorton, D., Xiao, S., Xu, N., Taylor, W., Vamvakas, S., Flamion, B., Lima, B.S., Kasper, P., Pasanen, M., Prasad, K., Troth, S., Bounous, D., Robinson-Gravatt, D., Betton, G., Davis, M.A., Akunda, J., McDuffie, J.E., Suter, L., Obert, L., Guffroy, M., Pinches, M., Jayadev, S., Blomme, E.A., Beushausen, S.A., Barlow, V.G., Collins, N., Waring, J., Honor, D., Snook, S., Lee, J., Rossi, P., Walker, E. and Mattes, W. (2010) Renal biomarker qualification submission: a dialog between the FDA-EMEA and Predictive Safety Testing Consortium. Nat. Biotechnol., 28, 455-462.   DOI   ScienceOn
20 Yu, Y., Jin, H., Holder, D., Ozer, J.S., Villarreal, S., Shughrue, P., Shi, S., Figueroa, D.J., Clouse, H., Su, M., Muniappa, N., Troth, S.P., Bailey, W., Seng, J., Aslamkhan, A.G., Thudium, D., Sistare, F.D. and Gerhold, D.L. (2010) Urinary biomarkers trefoil factor 3 and albumin enable early detection of kidney tubular injury. Nat. Biotechnol., 28, 470-477.   DOI   ScienceOn