• 제목/요약/키워드: Accuracy Rate

검색결과 3,386건 처리시간 0.031초

상악동 중격;임플란트 수술 계획시 파노라마와 치과용 전산화 단충촬영 분석 (Maxillary sinus septum;panoramic radiographic and dental computed tomographic analyses in the planning of implant surgery)

  • 소현자;정동근;권진희;유소현;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제36권1호
    • /
    • pp.147-154
    • /
    • 2006
  • Surgical intervention in the posterior maxillary region requires detailed knowledge of maxillary sinus anatomy and the possible anatomical variations. This study evaluated the incidence, location of maxillary sinus septa by using radiographic (panoramic radiography and computed tomography) findings and comparison of panoramic radography with CT in antral anatomical variation. This study was based on data from 70 sinuses in partial dentate maxilla. The sample consisted of 61 patients(25 women and 36 men, with ages ranging between 19 and 77 years and a mean age of $49.4{\pm}11.3$ years) who were being treatment-planned to receive implant-supported restorations. First, the panoramic images were examined for the presence of antral septa by radiologist and examiner who don't know about CT findings. And incidence of antral septa was evaluated using an axial plane of CT image. The incidence of septa was compared between panoramic radiography and CT. The accuracy of the incidence was compared between radiologists and dentists. A total of 20 septa were found in 70 sinuses on CT image and the prevalence of one or more septa per sinus was found to be 28.6%. The assumed incidence of septa on panoramic radiography was $27.6%{\pm}2.2%$ in radiologist and $31.9%{\pm}5.8%$ in dentists. Erroneous diagnosis rate was 11.42% in radiologist and 15.96% in dentists. 40% of antral septa were located in the anterior(premolar) region, 30% of septa were located in the middle(first molar) and posterior(second molar) region separately. Prior to implant placement, it seems appropriate to consider panoramic radiography as a standard radiographic examination and periapical radiographs may be used to complete the findings in regions not sharply depicted in the panoramic radiograph. And cross-sectional imaging should be used in sites with severe bone loss and close proximity of the maxillary sinus.

키넥트 깊이 측정 센서의 가시 범위 내 감지된 사물의 거리 측정 시스템과 그 응용분야 (Distance measurement System from detected objects within Kinect depth sensor's field of view and its applications)

  • 니욘사바 에릭;장종욱
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 춘계학술대회
    • /
    • pp.279-282
    • /
    • 2017
  • 마이크로소프트에서 게임용 자연스러운 사용자 인터페이스를 위해 개발된 깊이 카메라인 키넥트 깊이 측정 센서는 컴퓨터 비전 분야에 있어 매우 유용한 도구이다. 키넥트의 깊이 측정 센서와 그 높은 프레임률로 인해, 본 논문에서는 키넥트 카메라를 사용해 거리 측정 시스템을 개발하였으며, 이를 이동 시 인간과 같이 사물을 감지하는데 주변 환경을 인지하기 위해 시각 시스템이 필요한 무인 차량에 시험하였다. 즉, 키넥트 깊이 측정 센서를 이용해 가시 범위 내 사물을 감지하고 사물에서 시각 센서의 거리 측정 시스템을 개선한다. 감지된 사물을 정밀하게 확인하여 실제 사물인지, 또는 픽셀 노즈(nose)인지 판단해 실제 사물이 아닌 픽셀을 무시함으로써 처리 시간을 줄인다. 이미지 처리를 위한 오픈 CV 라이브러리와 함께 깊이 분할 기법을 활용하여, 키넥트 카메라의 가시 범위 내 사물을 확인할 수 있으며, 해당 사물과 센서 사이의 거리를 측정할 수 있다. 시험 결과에 따르면 본 시스템은 저가 범위 센서인 키넥트 카메라가 장착된 자율주행차에 사용하여 감지된 사물로부터 측정 거리에 이르면 어플리케이션 방식에 따라 프로세스를 처리할 수 있는 것으로 나타났다.

  • PDF

공간 데이터의 분포를 고려한 공간 엔트로피 기반의 의사결정 트리 기법 (A Spatial Entropy based Decision Tree Method Considering Distribution of Spatial Data)

  • 장윤경;유병섭;이동욱;조숙경;배해영
    • 정보처리학회논문지B
    • /
    • 제13B권7호
    • /
    • pp.643-652
    • /
    • 2006
  • 의사결정 트리는 데이터 마이닝의 분류와 예측 작업에 주로 사용되는 기법 중의 하나이다. 실생활에서 공간의사결정을 위한 분류를 수행할 때에는 인접 데이터의 위치와 분산도를 고려하는 것이 매우 중요하다. 기존의 공간 의사결정 트리는 데이터의 공간적 특성을 표현하기 위해 각 객체간의 유클리디안 거리비율을 엔트로피로 반영하여 트리 구축 시 이용하였다. 그러나 이것은 공간 객체간의 거리 비율만을 설명할 뿐 공간 차원에서의 데이터 분산 정도와 각 분류된 클래스간의 연관관계 등은 파악할 수 없다는 한계점이 있었다 본 논문에서는 분산도와 차별도 기반의 공간 엔트로피를 이용하여 공간 데이터의 분포도를 반영하는 공간 의사결정 트리를 제안한다 분산도는 분류된 클래스 내의 공간 객체 분포도를 나타내고 차별도는 다른 클래스 내 공간 객체와의 분포도 및 관계성을 나타낸다. 이러한 분산도와 차별도의 비율을 엔트로피 계산 시 이용함으로써 비공간적 속성으로 분류된 각 클래스가 공간적으로는 얼마나 뚜렷하게 분류되는지 알 수 있게 한다. 제안 기법은 정확성과 계산 비용에 있어서 기존 기법보다 각각 약 18%, 11%의 성능 향상을 보였다.

체외에서 ESI-MS/MS 탐지에 연결된 HPLC에 의한 Entacapon의 수량화: 생물학적 동등성 연구에 적용 (Quantification of Entacapone in Human Plasma by HPLC Coupled to ESI-MS/MS Detection: Application to Bioequavalence Study)

  • Balasekhara Reddy., Ch.;Baburao., Ch.;Chandrasekhar., K.B.;Kanchanamala., K.;RihanaParveen., S.K.;Ravikumar., Konda
    • 대한화학회지
    • /
    • 제54권5호
    • /
    • pp.523-532
    • /
    • 2010
  • 제안된 방법은 국제표준(IS)인 Entacapone-d10(EAD10)을 사용하여 체외에서 Entacapon(EA)의 정량화를 위한 간단하고, 감도가 좋고, 명확한 액체 크로마토그래피-직렬 질량 분석법(LC-ESI-MS/MS)이다. 크로마토그래피 분리는 Zorbax SB-C18에서 수행되었고, $2.1{\times}50\;mm$, $5\;{\mu}m$ 컬럼과 10 mM Ammonium formate (pH 3.0)로 구성된 이동상에서 수행되었다: 0.7 mL/min 유속의 아세토나이트릴(60:40 v/v)은 액체-액체 추출을 따른다. EA와 EAD10은 다중 반응 탐색법(MRM)에서 수소부가물을 가지고 상대적으로 포지티브 모드인 m/z $306.1{\rightarrow}233.1$$316.3{\rightarrow}233.0$에서 수소부과물을 가지고 측정되었다. 그 방법은 상관계수($r^2$) 0.993 이상을 갖는 1.00 - 2000.00 ng/mL의 선형 농도 범위 이상으로 입증되었다. 하루 중과 하루 이내에 3.60에서 7.30과 4.20에서 5.50% 이내의 정밀성과 97.30에서 104.20과 98.30에서 105.80% 이내의 정확도는 EA를 위해 입증되었다. 이러한 방법은 건강한 인도인 자원자들의 생물학적 동등성 연구에서 성공적으로 적용되었다.

신교통수단 수혜자의 시장분할을 고려한 수단선택 모형 개발 (A Mode Choice Model with Market Segmentation of Beneficiary Group of New Transit Facility)

  • 김덕녕;최아름;황재민;김동규
    • 대한토목학회논문집
    • /
    • 제33권2호
    • /
    • pp.667-677
    • /
    • 2013
  • 신교통수단의 도입은 통행 대안 간의 수단분담률에 영향을 미친다. 그러나 수단분담률을 추정하는 데에 일반적으로 사용되는 다항로짓 모형은 통행자 선택의 다양성을 반영하기 어렵기 때문에 수단선택 특성을 정확하게 파악하는 데에 한계가 있다. 이러한 문제는 교통수단의 도입 효과를 과다 또는 과소추정하는 결과를 야기하며, 이는 심각한 사회적 손실을 초래할 수 있다. 본 연구는 선호의 동질성 문제를 극복할 수 있는 방법론을 모색하는 것을 목적으로 한다. 전체모집단을 직접수혜자와 간접수혜자로 구분하는 시장분할 구조를 적용하여 선호의 이질성을 반영할 수 있도록 한다. 제주도의 조사 자료를 활용하여 수단 선택 모형이 추정되며, 통계적 검정이 수행된다. 분석 결과, 신교통수단의 통행특성이 고급화됨에 따라 도심부에 거주하는 직접수혜자의 수단 전환율이 증가하는 것으로 확인되었다. 본 연구는 수단전환 패턴의 다양성을 반영함으로써 신교통수단 도입시 수요예측의 정확성을 제고하는 데에 기여할 것으로 사료된다.

GDI 고압펌프의 유동특성에 관한 연구 (A Study of the Fluidic Characteristics of High-Pressure Fuel Pumps for GDI Engines)

  • 이상진;노유정;류하오;이재천;신용남;박용덕;강명권
    • 대한기계학회논문집B
    • /
    • 제39권5호
    • /
    • pp.455-461
    • /
    • 2015
  • 고압연료펌프는 GDI 엔진의 핵심 구성요소로써, 엔진출력 및 연료 효율을 향상시키기 위해서는 고압연료펌프의 유동특성을 연구하는 것이 필요하다. 본 연구에서는 유압해석툴인 AMEsim을 이용하여 고압연료펌프의 통합 모델을 생성하여 유동해석을 수행하였다. 하지만, AMEsim은 시스템 해석을 위한 1차원 모델이므로 복잡한 유동현상이 발생하는 부근에서의 해석 결과는 정확하지 않은 단점이 있으므로 본 연구에서는 전산해석프로그램인 Fluent를 이용하여 난류유동이 발생하는 체크밸브의 흡입부와 토출부에서 유량과 알짜힘을 계산하였다. 다양한 압력조건과 밸브 간극변화에 따른 CFD 해석 결과는 AMEsim모델에 대한 룩업테이블로 사용되어 AMEsim의 결과를 보완함으로써 고압연료펌프에 대한 성능 분석결과의 정확성을 향상시키는 결과를 얻을 수 있었다.

일개 한방병원에 파킨슨병으로 내원한 환자의 사상의학적 특성에 관한 고찰 (The Analysis on Characteristics according to Sasang Constitution of Patients with Parkinson's Disease in a Korean Medicine Hospital)

  • 김소형;이슬;이용재;배나영;이정윤
    • 사상체질의학회지
    • /
    • 제30권3호
    • /
    • pp.62-73
    • /
    • 2018
  • Objectives The aim of this study was to make an analysis of clinical characteristics and status of Sasang constitutional medicine of patients with Parkinson's Disease who visited a Korean medicine hospital. Methods We studied 129 patients with Parkinson's Disease who visited a Korean medicine hospital from September 1, 2012 to June 30, 2018. We retrospectively collected medical history and characteristics of subjects using data of EMR (electronic medical record). Results The proportion of female was higher than male. The average age was 60s. The patients visited a hospital more than one year after the occurrence of symptoms. And they were mostly under western medicine treatment. Among the 129 patients, 56 persons(43.4%) were Taeeumin, 45 persons(34.9%) Soyangin and 28 persons Soeumin(21.7%). In the distribution of prescription according Sasang Constitutional Medicine symptomatology, there was no significant difference in the proportion of exterior cold disease(48.9%) and interior heat disease(51.1%) in Soyangin. Meanwhile the proportion of heat disease's prescription was higher than cold disease in Taeeumin(73.2%) and Soeumin(84.1%). The majority of disease were Dry-febrile symptom(73.2%) of heat disease in Taeeumin, Yang depletion-syndrome(64.3%) of heat disease in Soeumin, and Gyolhyung-symptom(33.3%) of exterior cold disease and Wasting thirst-syndrome(22.2%) of interior heat disease in Soyangin, Conclusions By Developing of guideline for treatment of Parkinson's Disease through analyzing on clinical characteristics and distribution of Sasang Constitutional Medicine symptomatology could contribute to the improvement of the cure rate and accuracy of constitution pattern.

전기식 온구기에 대한 안전성 및 성능 평가 가이드라인 개발 연구 (Study on Developing Assessment Guideline for Safety and Performance of Electric Moxibustion Apparatus)

  • 이승호;강중원;남동우;김은정;이혜정;김갑성;이재동
    • Journal of Acupuncture Research
    • /
    • 제27권1호
    • /
    • pp.75-86
    • /
    • 2010
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric moxibustion apparatus (class II medical device). Methods : We drafted the guideline for safety and performance assessment of electric moxibustion apparatus by referring the existing standards, guidelines and measurement data from commercially available products. Temperature characteristics such as maximum temperature and ramp time, and physical characteristics such as weight, noise and diameter were measured. User friendliness was also evaluated for commercial devices. Results : This guideline only can be applied to the electric moxibustion apparatus where moxa is being heated by electricity for medical proposes. Maximum temperature of higher than $50^{\circ}C$ can be achieved mostly. Ramp rate of temperature seems to be reliable. Control of temperature is needed to be improved. Moxa and its derivative products seem to be regulated for reliable temperature performance for clinical application. Requirements for design and development of electric moxibustion apparatus are suggested : temperature indicator, temperature control and its accuracy, safety measure, surge protection, user friendliness and instruction for use (IFU). Design recommendation of the reduction of noise level and energy loss are suggested for better products. Conclusions : We proposed a guideline for safety and performance assessment of electric moxibustion apparatus to improve the quality of relating products and aid their commercialization by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

두경부 감염 환자에서 혈청 내 C-Reactive Protein의 변화 (THE CHANGES OF SERUM C-REACTIVE PROTEIN IN THE HEAD AND NECK INFECTION)

  • 이주현;김진수;이상한;김철환
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권1호
    • /
    • pp.5-13
    • /
    • 2003
  • 본 연구의 목적은 두경부 감염 환자에서 적혈구침강속도(ESR), 백혈구와 비교해 혈장 내 C-Reactive Protein(CRP)이 가지는 진단과 경과관찰에서의 기여도를 아는 데 있다. 본 연구를 위해 31명의 감염환자를 실험군으로, 32명의 악교정 수술 환자를 대조군으로 설정하여 다음과 같은 결과를 얻었다. 1. 실험군에서의 C-Reactive Protein(CRP)은 대조군의 CRP에 비해 더 높은 수치를 나타내며 감염이 지속되었던 증례를 제외하고는 지속적으로 감소하는 경향을 나타내었다(P<0.001). 2. ESR은 실험군과 대조군에서 모두 일정한 경향이 없었다. 3. 각 변수간의 상관관계는 CRP와 백혈구가 상관계수 0.664로 가장 높은 양의 상관관계를 나타내었다(r=0.664, P<0.01). 4. 설정된 ROC curve에서 분류기준값(cut-off value)의 변화에 따라 CRP 곡선의 증가가 빠르게 나타나고 측정된 곡선의 아래 면적(AUC: Area Under the Curve)이 0.744로 높은 값을 나타내어 예측의 정확도가 높다고 판단된다. 5. 실험군에서 회복일(recovery day)에 각 변수의 민감도는 CRP가 83%, ESR이 17%, 백혈구가 71%로 나타났다. 이상의 연구로 미루어 볼 때, 두경부 영역에서 CRP는 감염을 진단하고 경과관찰을 하는데 있어 ESR이나 Leukocyte에 비해 더 민감하게 환자를 감시(monitoring)할 수 있는 유용한 검사라고 사료된다.

고화질 영상 시스템 응용을 위한 12비트 130MS/s 108mW $1.8mm^2$ 0.18um CMOS A/D 변환기 (A 12b 130MS/s 108mW $1.8mm^2$ 0.18um CMOS ADC for High-Quality Video Systems)

  • 한재열;김영주;이승훈
    • 대한전자공학회논문지SD
    • /
    • 제45권3호
    • /
    • pp.77-85
    • /
    • 2008
  • 본 논문에서는 TFT-LCD 디스플레이 및 디지털 TV 시스템 응용과 같이 고속으로 동작하며 고해상도, 저전력 및 소면적을 동시에 요구하는 고화질 영상시스템 응용을 위한 12비트 130MS/s 108mW $1.8mm^2$ 0.18um CMOS ADC를 제안한다. 제안하는 ADC는 3단 파이프라인 구조를 사용하여 고해상도와 높은 신호처리 속도에서 전력 소모 및 면적을 최적화하였다. 입력단 SHA 회로에는 Nyquist 입력에서도 12비트 이상의 정확도로 신호를 샘플링하기 위해 게이트-부트스트래핑 회로를 적용함과 동시에 트랜스컨덕턴스 비율을 적절히 조정한 2단 증폭기를 사용하여 12비트에 필요한 높은 DC 전압 이득과 충분한 위상 여유를 갖도록 하였으며, MDAC의 커패시터 열에는 높은 소자 매칭을 얻기 위하여 각각의 커패시터 주위를 공정에서 제공하는 모든 금속선으로 둘러싸는 3차원 완전 대칭 구조를 갖는 레이아웃 기법을 적용하였다. 한편, 제안하는 ADC에는 전원 전압 및 온도에 덜 민감한 저전력 기준 전류 및 전압 발생기를 온-칩으로 집적하여 잡음을 최소화하면서 시스템 응용에 따라 선택적으로 다른 크기의 기준 전압 값을 외부에서 인가할 수 있도록 하였다. 제안하는 시제품 ADC는 0.18um n-well 1P6M CMOS 공정으로 제작되었으며, 측정된 DNL 및 INL은 12비트 해상도에서 각각 최대 0.69LSB, 2.12LSB의 수준을 보이며, 동적 성능으로는 120MS/s와 130MS/s의 동작 속도에서 각각 최대 53dB, 51dB의 SNDR과 68dB, 66dB의 SFDR을 보여준다. 시제품 ADC의 칩 면적은 $1.8mm^2$이며 전력 소모는 1.8V 전원 전압과 130MS/s에서 108mW이다.