• Title/Summary/Keyword: Accuracy Rate

Search Result 3,386, Processing Time 0.026 seconds

Optimal Threshold from ROC and CAP Curves (ROC와 CAP 곡선에서의 최적 분류점)

  • Hong, Chong-Sun;Choi, Jin-Soo
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.5
    • /
    • pp.911-921
    • /
    • 2009
  • Receiver Operating Characteristic(ROC) and Cumulative Accuracy Profile(CAP) curves are two methods used to assess the discriminatory power of different credit-rating approaches. The points of optimal classification accuracy on an ROC curve and of maximal profit on a CAP curve can be found by using iso-performance tangent lines, which are based on the standard notion of accuracy. In this paper, we offer an alternative accuracy measure called the true rate. Using this rate, one can obtain alternative optimal threshold points on both ROC and CAP curves. For most real populations of borrowers, the number of the defaults is much less than that of the non-defaults, and in such cases the true rate may be more efficient than the accuracy rate in terms of cost functions. Moreover, it is shown that both alternative scores of optimal classification accuracy and maximal profit are the identical, and this single score coincides with the score corresponding to Kolmogorov-Smirnov statistic used to test the homogeneous distribution functions of the defaults and non-defaults.

Calculation of Sample Size for Guided Missile Considering Test Method and Reliability Growth (유도무기 시험평가 방법과 신뢰성 성장을 고려한 시험 수량 산출)

  • Lee, Youn-ho;Kim, Jae-hwang;Lee, Kye-shin;Lee, Jong-sin;Lee, Myoung-jin;Kim, Doo-hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.844-852
    • /
    • 2017
  • Since guided weapon is high-cost and one-shot device which is non-reusable, it requires a lot of resources to prove required accuracy as a part of reliability demonstration. Once a test for proving accuracy rate of guided missile fails, it causes an additional cost and delay of schedule. This study introduces an equation for proper sample size and plan for guided-missile accuracy rate test in order to minimize the risk of test failure. Proper sample size for the test is derived by considering the reliability growth. Furthermore, each task for accuracy rate test is defined according to the development step. Therefore, this study can contribute to reduce sample size for accuracy rate test in order to meet the reliability requirement and assure transparency in the test process.

A Study on Cutting Conditions and Finishing Machining of Si Material Using Laser Assisted Module (레이저 보조 모듈을 이용한 Si 소재의 절삭조건 및 보정가공에 관한 연구)

  • Young-Durk Park
    • Design & Manufacturing
    • /
    • v.17 no.2
    • /
    • pp.15-21
    • /
    • 2023
  • In this study, a diamond turning machine and a laser-assisted machining module were utilized for the complex combined cutting of aspheric shapes and fine patterns on the surface of high-hardness brittle material, silicon. The analysis of material's form accuracy and corrective machining was conducted based on key factors such as laser output, rotational speed, feed rate, and cutting depth to achieve form accuracy below 1 ㎛ and surface roughness below 0.1 ㎛. The cutting condition and corrective machining methods were investigated to achieve the desired form accuracy and surface roughness. The rotational speed of the spindle and the linear feed rate of the diamond turning machine were varied in five stages for the cutting condition test. Surface roughness and form accuracy were measured using both a contact surface profilometer and a non-contact surface profilometer. The experimental results revealed a tendency of improved surface roughness with increased rotational speed of the workpiece, and the best surface roughness and form accuracy were observed at a feed rate of 5 mm/min. Furthermore, based on the cutting condition experiments, corrective machining was performed. The experimental results demonstrated an improvement in form accuracy from 0.94 ㎛ to 0.31 ㎛ and a significant reduction in the average value of the surface roughness curve from 0.234 ㎛ to 0.061 ㎛. This research serves as a foundation for future studies focusing on the machinability in relation to laser output parameters.

A Study on the High-Accuracy Power Meter and Reliability Verification Plan (고정밀 전력미터의 개발과 신뢰성 확보 방안에 대한 연구)

  • Lee, Sanghun;LEE, Changhwa
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1046-1053
    • /
    • 2017
  • We propose a design method of high accuracy power measuring device and the method of securing the reliability of the measured data. As a design method for the development of the high accuracy power measuring device, the circuit was made by reflecting the high accuracy power measuring ICs and the CT (Current Transformer). To ensure the reliability of the power meter, we requested to the watt-hour meter certified testing organization to measure the error rate, and the error rate of active power based on the "Wattmeter Technical Standard(Revision notify 2014-283)" was measure, and the error rate was confirmed to be less than 0.1%.

Evaluating the Accuracy of Blood Pressure Measurement (혈압측정의 정확성 평가)

  • Cho, Sung-Hyun;Hwang, Jeong-Hae;Kim, Eun-Gyung;Oh, Byung-Hee;Kim, Chang-Yup
    • Quality Improvement in Health Care
    • /
    • v.3 no.1
    • /
    • pp.94-103
    • /
    • 1996
  • Background : Blood pressure is an important indicator in diagnosis and assessing treatment of a patient. Clinical staffs use blood pressure on the assumption that measured value is accurate and reliable. However, whether measured blood pressure is accurate has been rarely investigated in Korea. Objectives : The aims of this study are to evaluate clinical staffs' knowledge and technique as well as accuracy of sphygmomanometer. Also the program to improve the measurement is developed. Methods : Seventy-three registered nurses were asked nine multiple choice questions including Korotkoff sound, cuff size, and deflation rate. Simultaneously characteristics of nurses were examined, age, working place, duration of employment and academic degree. A testing videotape(Standardizing Measurement Video-Tutored Course) was used for evaluating the accuracy of measurement. Testees were to read and record the 12 cases of blood pressure measurement, watching a falling mercury column and hearing Korotkoff sounds. After 10 minutes' education, they were again tested with the same cases. Additionally, 83 mercury sphygmomanometers were checked to find defects such as inaccurate calibration and zero setting, leaky bladder, etc. Results: For the knowledge testing correct response rate was 41.1%. They were the lowest in selecting the proper cuff size and Korotkoff sound. In examining accuracy of blood pressure with videotape, nurses had 67.7% correct response rate. The correct response rate was significantly improved by a session of education. About 23% of sphygmomanometers was without discernable defects. Conclusion : The knowledge and skill of clinical staffs along with the accuracy of equipment have to be improved. A properly designed education program would contribute to the accuracy improvement of blood pressure measurement. Also, more concerns should be given to the precision and maintenance of equipment.

  • PDF

A Study on the Improvement of Accuracy of Cardiomegaly Classification Based on InceptionV3 (InceptionV3 기반의 심장비대증 분류 정확도 향상 연구)

  • Jeong, Woo Yeon;Kim, Jung Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.45-51
    • /
    • 2022
  • The purpose of this study is to improve the classification accuracy compared to the existing InceptionV3 model by proposing a new model modified with the fully connected hierarchical structure of InceptionV3, which showed excellent performance in medical image classification. The data used for model training were trained after data augmentation on a total of 1026 chest X-ray images of patients diagnosed with normal heart and Cardiomegaly at Kyungpook National University Hospital. As a result of the experiment, the learning classification accuracy and loss of the InceptionV3 model were 99.57% and 1.42, and the accuracy and loss of the proposed model were 99.81% and 0.92. As a result of the classification performance evaluation for precision, recall, and F1 score of Inception V3, the precision of the normal heart was 78%, the recall rate was 100%, and the F1 score was 88. The classification accuracy for Cardiomegaly was 100%, the recall rate was 78%, and the F1 score was 88. On the other hand, in the case of the proposed model, the accuracy for a normal heart was 100%, the recall rate was 92%, and the F1 score was 96. The classification accuracy for Cardiomegaly was 95%, the recall rate was 100%, and the F1 score was 97. If the chest X-ray image for normal heart and Cardiomegaly can be classified using the model proposed based on the study results, better classification will be possible and the reliability of classification performance will gradually increase.

Improvement of the Accuracy in Cornering Cut Using End Mill (엔드밀의 코너 가공시 가공 정밀도 향상에 관한 연구)

  • Kim, Yong-Hyeon;Go, Seong-Rim
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.3
    • /
    • pp.399-407
    • /
    • 2001
  • The Surface, generated by end milling operation, is deteriorated by tool runout, vibration, friction, tool deflection, etc. Especially in cornering cut, surface accuracy is usually determined by varying cutting forces, which causes tool deflections. Cutting conditions like feed rate is usually kept constant during machining a part, which causes dimensional error in severe cutting. Cornering cut is a typical example of deterioration of surface accuracy when constant feed rate is applied. Therefore it becomes important to develop NC post processor module to determine optimal cutting conditions in various cutting situations. In this paper, cutting force is predicted in cornering cut with flat end mill and feed rate is determined by constraining constantly resultant force. Also some control characteristics of CNC machining center are evaluated.

Diadochokinetic Characters in the Persons with Spastic Cerebral Palsy in Severity ; Rate, Regularity, Accuracy and Consistency (심한정도에 따른 경직형 뇌성마비인의 교호운동 특성 ; 속도, 규칙성, 정확성 및 일관성을 중심으로)

  • Nam Hyun-Wook;Ahn Jong-Bok;Kwon Do-Ha
    • Proceedings of the KSPS conference
    • /
    • 2006.05a
    • /
    • pp.105-108
    • /
    • 2006
  • The purpose of this study was to investigate the diadochokinetic characters in the patients with spastic cerebral palsy(CP) in severity. The diadochokinetic characters were measured through rate, regularity, accuracy and consistency. The subjects participated in this study included 27 persons with spastic CP(mild- 9, moderate- 9, severe- 9) and 9 normal persons who is around 11-20 years old. On the result of this study, rate in AMR was significant difference between all spastic groups and normal group, and rate in SMR was significant difference between normal and mild groups and moderate and severe groups. In regularity of diadochokinetic task, severe group had significant difference the other groups. Finally, accuracy and consistency of diadochokinetic task exhibited significant difference between all spastic groups and normal group.

  • PDF

TPR-TNR plot for confusion matrix

  • Hong, Chong Sun;Oh, Tae Gyu
    • Communications for Statistical Applications and Methods
    • /
    • v.28 no.2
    • /
    • pp.161-169
    • /
    • 2021
  • The two-dimensional confusion matrix used in credit assessment, biostatistics, and many other fields consists of true positive, true negative, false positive, and false negative. Their rates, such as the true positive rate (TPR), true negative rate (TNR), false positive rate, and false negative rate, can be applied to measure its accuracy. In this study, we propose the TPR-TNR plot, a graphical method that can geometrically describe and explain these rates based on the confusion matrix. The proposed TPR-TNR plot consists of two right-angled triangles. We obtain that the TPR and TNR describe the acute angles of right-angled triangles in the plot. These acute angles can be used to determine optimal thresholds corresponding to lots of accuracy measures.

Analysis on Real Discount Rate for Prediction Accuracy Improvement of Economic Investment Effect (경제적 투자효과의 예측 정확도 향상을 위한 실질할인율 분석)

  • Lee, Chijoo;Lee, Eul-Bum
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.101-109
    • /
    • 2015
  • The expected economic effect by investment was divided by square of real discount rate annually for change to present value. Thus, the impact of real discount rate on economic analysis is larger than other factors. The existing general method for prediction of real discount rate is application of average data during past certain period. This study proposed prediction method of real discount rate for accuracy improvement. First, the economic variables which impact on interest rate of business loan and consumer price of real discount rate were determined. The variables which impact on interest rate of business loan were selected to call rate and exchange rate. The variable which impact on consumer price index was selected to producer price index. Next, the effect relation was analyzed between real discount rate and selected variables. The significant effect relation were analyzed to exit. Lastly, the real discount rate was predicted from 2008 to 2010 based on related economic variables. The accuracy of prediction result was compared with actual data and average data. The real discount rate based on actual data, predicted data, and average data were analyzed to -1.58%, -0.22%, and 6.06%, respectively. Though the proposed method in this study was not considered special condition such as financial crisis, the prediction accuracy was much higher than result based on average data.