• 제목/요약/키워드: Accuracy Assessment

검색결과 1,599건 처리시간 0.118초

Assessment of solid components of borderline ovarian tumor and stage I carcinoma: added value of combined diffusion- and perfusion-weighted magnetic resonance imaging

  • Kim, See Hyung
    • Journal of Yeungnam Medical Science
    • /
    • 제36권3호
    • /
    • pp.231-240
    • /
    • 2019
  • Background: We sought to determine the value of combining diffusion-weighted (DW) and perfusion-weighted (PW) sequences with a conventional magnetic resonance (MR) sequence to assess solid components of borderline ovarian tumors (BOTs) and stage I carcinomas. Methods: Conventional, DW, and PW sequences in the tumor imaging studies of 70 patients (BOTs, n=38; stage I carcinomas, n=32) who underwent surgery with pathologic correlation were assessed. Two independent radiologists calculated the parameters apparent diffusion coefficient (ADC), $K^{trans}$ (vessel permeability), and $V_e$ (cell density) for the solid components. The distribution on conventional MR sequence and mean, standard deviation, and 95% confidence interval of each DW and PW parameter were calculated. The inter-observer agreement among the two radiologists was assessed. Area under the receiver operating characteristic curve (AUC) and multivariate logistic regression were performed to compare the effectiveness of DW and PW sequences for average values and to characterize the diagnostic performance of combined DW and PW sequences. Results: There were excellent agreements for DW and PW parameters between radiologists. The distributions of ADC, $K^{trans}$, and $V_e$ values were significantly different between BOTs and stage I carcinomas, yielding AUCs of 0.58 and 0.68, 0.78 and 0.82, and 0.70 and 0.72, respectively, with ADC yielding the lowest diagnostic performance. The AUCs of the DW, PW, and combined PW and DW sequences were $0.71{\pm}0.05$, $0.80{\pm}0.05$, and $0.85{\pm}0.05$, respectively. Conclusion: Combining PW and DW sequences to a conventional sequence potentially improves the diagnostic accuracy in the differentiation of BOTs and stage I carcinomas.

Assessment of compressive strength of cement mortar with glass powder from the early strength

  • Wang, Chien-Chih;Ho, Chun-Ling;Wang, Her-Yung;Tang, Chi
    • Computers and Concrete
    • /
    • 제24권2호
    • /
    • pp.151-158
    • /
    • 2019
  • The sustainable development principle of replacing natural resources with renewable material is an important research topic. In this study, waste LCD (liquid crystal display) glass powder was used to replace cement (0%, 10%, 20% and 30%) through a volumetric method using three water-binder ratios (0.47, 0.59, and 0.71) to make cement mortar. The compressive strength was tested at the ages of 7, 28, 56 and 91 days. The test results show that the compressive strength increases with age but decreases as the water-binder ratio increases. The compressive strength slightly decreases with an increase in the replacement of LCD glass powder at a curing age of 7 days. However, at a curing age of 91 days, the compressive strength is slightly greater than that for the control group (glass powder is 0%). When the water-binder ratios are 0.47, 0.59 and 0.71, the compressive strength of the various replacements increases by 1.38-1.61 times, 1.56-1.80 times and 1.45-2.20 times, respectively, during the aging process from day 7 to day 91. Furthermore, a prediction model of the compressive strength of a cement mortar with waste LCD glass powder was deduced in this study. According to the comparison between the prediction analysis values and test results, the MAPE (mean absolute percentage error) values of the compressive strength are between 2.79% and 5.29%, and less than 10%. Thus, the analytical model established in this study has a good forecasting accuracy. Therefore, the proposed model can be used as a reliable tool for assessing the design strength of cement mortar from early age test results.

오리사 바닥재의 수분 증발량 평가 (Assessment of Evaporation Rates from Litter of Duck House)

  • 이상연;이인복;김락우;여욱현;데카노 크리스티나;김준규;최영배;박유미;정효혁
    • 한국농공학회논문집
    • /
    • 제61권5호
    • /
    • pp.101-108
    • /
    • 2019
  • The domestic duck industry is the sixth-largest among the livestock industries. However, 34.3% of duck houses were the duck houses arbitrarily converted from plastic greenhouses. This type of duck house was difficult to properly manage internal air temperature and humidity environment. Humidity environment inside duck houses is an important factor that directly affects the productivity and disease occurrence of the duck. Although the humidity environments of litters (bedding materials) affect directly the inside environment of duck houses, there are only few studies related to humidity environment of litters. In this study, evaporation rates from litters were evaluated according to air temperature, relative humidity, water contents of litters, and wind speed. The experimental chamber was made to measure evaporation rates from litters. Temperature and humidity controlled chamber was utilized during the conduct of the laboratory experiments. Using the measured data, a multi linear regression analysis was carried out to derive the calculation formula of evaporation rates from litters. In order to improve the accuracy of the multi linear regression model, the partial vapor pressure directly related to evaporation was also considered. Variance inflation factors of air temperature, relative humidity, partial vapor pressure, water contents of litters, and wind speed were calculated to identify multicollinearity problem. The Multiple $R^2$ and adjusted-$R^2$ of regression model were calculated at 0.76 and 0.71, respectively. Therefore, the regression models were developed in this study can be used to estimate evaporation rates from the litter of duck houses.

Comparison of the outcomes of nasal bone reduction using serial imaging

  • Lee, Cho Long;Yang, Ho Jik;Hwang, Young Joong
    • 대한두개안면성형외과학회지
    • /
    • 제22권4호
    • /
    • pp.193-198
    • /
    • 2021
  • Background: Nasal bone fractures are frequently encountered in clinical practice. Although fracture reduction is simple and correction requires a short operative time, low patient satisfaction and relatively high complication rates remain issues for many surgeons. These challenges may result from inaccuracies in fracture recognition and assessment or inappropriate surgical planning. Findings from immediate postoperative computed tomography (CT) scans and those performed at 4 to 6 weeks postoperatively were compared to evaluate the accuracy and outcomes of nasal fracture reduction. Methods: This retrospective study included patients diagnosed with nasal bone fractures at our department who underwent closed reduction surgery. Patients who did not undergo additional CT scans were excluded from the study. Clinical examinations, patient records, and radiographic images were evaluated in 20 patients with nasal bone fractures. Results: CT findings from immediately after surgery and a 1month follow-up were compared in 20 patients. Satisfactory nasal projection and aesthetically acceptable results were observed in patients with accurate correction or mild overcorrection, while undercorrection was associated with unfavorable results. Conclusion: Closed reduction surgery for correcting nasal bone fractures usually provides acceptable outcomes with relatively few complications. If available, immediate postoperative CT scans are recommended to guide surgeons in the choice of whether to perform secondary adjustments if the initial results are unsatisfactory. Based on photogrammetric data, nasal bone reduction with accurate correction or mild overcorrection achieved acceptable and stable outcomes at 1 month postoperatively. Therefore, when upward dislocation is observed on postoperative CT, one can simply observe without a subsequent intervention.

Development of a Simultaneous Analytical Method for Diquat, Paraquat and Chlormequat in Animal Products Using UPLC-MS/MS

  • Cho, Il Kyu;Rahman, Md. Musfiqur;Seol, Jae Ung;Noh, Hyun Ho;Jo, Hyeong-Wook;Moon, Joon-Kwan
    • 한국환경농학회지
    • /
    • 제39권4호
    • /
    • pp.368-374
    • /
    • 2020
  • BACKGROUND: The residual analysis of polar pesticides has remained a challenge. It is even more difficult to simultaneously analyze multiple polar pesticides. Diquat, paraquat, and chlormequat are typical examples of highly polar pesticides. The existing methods for the analysis of diquat, paraquat and chlormequat are complex and time consuming. Therefore, a simple, quick and effective method was developed in the represent study for simultaneous analysis of diquat, paraquat and chlormequat in animal products, meat and fat using UPLC-MS/MS. METHODS AND RESULTS: Sample extraction was carried out using acidified acetonitrile and water and re- extracted with acidified acetonitrile and combine the extracts followed by centrifugation. The extract was then cleaned up with a HLB cartridge after reconstitution with acidic acetonitrile and water. The method was validated in quintuplicate at three different concentrations. The limits of detection (LOD) and quantification (LOQ) were 0.0015 and 0.005 mg/L, respectively. Matrix suppression effect was observed for all of the analytes. A seven point matrix matched calibration curve was constructed for each of the compound resulted excellent linearity with determination coefficients (R2) ≥ 0.991. Accuracy and precision of the method was calculated from the recovery and repeatability and ranged from 62.4 to 119.7% with relative standard deviation less than 18.8%. CONCLUSION: The recovery and repeatability of the developed method were in the acceptable range according to the Codex Alimentarius guideline. The developed method can be applied for the routine monitoring of diquat, paraquat, and chlormequat in animal products, meat and fat.

한국형수치예보모델 KIM의 폭염 예측 성능 검증 (Evaluation of Heat Waves Predictability of Korean Integrated Model)

  • 정지영;이은희;박혜진
    • 대기
    • /
    • 제32권4호
    • /
    • pp.277-295
    • /
    • 2022
  • The global weather prediction model, Korean Integrated Model (KIM), has been in operation since April 2020 by the Korea Meteorological Administration. This study assessed the performance of heat waves (HWs) in Korea in 2020. Case experiments during 2018-2020 were conducted to support the reliability of assessment, and the factors which affect predictability of the HWs were analyzed. Simulated expansion and retreat of the Tibetan High and North Pacific High during the 2020 HW had a good agreement with the analysis. However, the model showed significant cold biases in the maximum surface temperature. It was found that the temperature bias was highly related to underestimation of downward shortwave radiation at surface, which was linked to cloudiness. KIM tended to overestimate nighttime clouds that delayed the dissipation of cloud in the morning, which affected the shortage of downward solar radiation. The vertical profiles of temperature and moisture showed that cold bias and trapped moisture in the lower atmosphere produce favorable conditions for cloud formation over the Yellow Sea, which affected overestimation of cloud in downwind land. Sensitivity test was performed to reduce model bias, which was done by modulating moisture mixing parameter in the boundary layer scheme. Results indicated that the daytime temperature errors were reduced by increase in surface solar irradiance with enhanced cloud dissipation. This study suggested that not only the synoptic features but also the accuracy of low-level temperature and moisture condition played an important role in predicting the maximum temperature during the HWs in medium-range forecasts.

Sensitivity, specificity, and predictive value of cardiac symptoms assessed by emergency medical services providers in the diagnosis of acute myocardial infarction: a multi-center observational study

  • Park, Jeong Ho;Moon, Sung Woo;Kim, Tae Yun;Ro, Young Sun;Cha, Won Chul;Kim, Yu Jin;Shin, Sang Do
    • Clinical and Experimental Emergency Medicine
    • /
    • 제5권4호
    • /
    • pp.264-271
    • /
    • 2018
  • Objective For patients with acute myocardial infarction (AMI), symptoms assessed by emergency medical services (EMS) providers have a critical role in prehospital treatment decisions. The purpose of this study was to evaluate the diagnostic accuracy of EMS provider-assessed cardiac symptoms of AMI. Methods Patients transported by EMS to 4 study hospitals from 2008 to 2012 were included. Using EMS and administrative emergency department databases, patients were stratified according to the presence of EMS-assessed cardiac symptoms and emergency department diagnosis of AMI. Cardiac symptoms were defined as chest pain, dyspnea, palpitations, and syncope. Disproportionate stratified sampling was used, and medical records of sampled patients were reviewed to identify an actual diagnosis of AMI. Using inverse probability weighting, verification bias-corrected diagnostic performance was estimated. Results Overall, 92,353 patients were enrolled in the study. Of these, 13,971 (15.1%) complained of cardiac symptoms to EMS providers. A total of 775 patients were sampled for hospital record review. The sensitivity, specificity, positive predictive value, and negative predictive value of EMS provider-assessed cardiac symptoms for the final diagnosis of AMI was 73.3% (95% confidence interval [CI], 70.8 to 75.7), 85.3% (95% CI, 85.3 to 85.4), 3.9% (95% CI, 3.6 to 4.2), and 99.7% (95% CI, 99.7 to 99.8), respectively. Conclusion We found that EMS provider-assessed cardiac symptoms had moderate sensitivity and high specificity for diagnosis of AMI. EMS policymakers can use these data to evaluate the pertinence of specific prehospital treatment of AMI.

Ultrasonographic Evaluation of Diffuse Thyroid Disease: a Study Comparing Grayscale US and Texture Analysis of Real-Time Elastography (RTE) and Grayscale US

  • Yoon, Jung Hyun;Lee, Eunjung;Lee, Hye Sun;Kim, Eun-Kyung;Moon, Hee Jung;Kwak, Jin Young
    • International journal of thyroidology
    • /
    • 제10권1호
    • /
    • pp.14-23
    • /
    • 2017
  • Background and Objectives: To evaluate and compare the diagnostic performances of grayscale ultrasound (US) and quantitative parameters obtained from texture analysis of grayscale US and elastography images in evaluating patients with diffuse thyroid disease (DTD). Materials and Methods: From September to December 2012, 113 patients (mean age, $43.4{\pm}10.7years$) who had undergone preoperative staging US and elastography were included in this study. Assessment of the thyroid parenchyma for the diagnosis of DTD was made if US features suggestive of DTD were present. Nine histogram parameters were obtained from the grayscale US and elastography images, from which 'grayscale index' and 'elastography index' were calculated. Diagnostic performances of grayscale US, texture analysis using grayscale US and elastography were calculated and compared. Results: Of the 113 patients, 85 (75.2%) patients were negative for DTD and 28 (24.8%) were positive for DTD on pathology. The presence of US features suggestive of DTD showed significantly higher rates of DTD on pathology, 60.7% to 8.2% (p<0.001). Specificity, accuracy, and positive predictive value was highest in US features, 91.8%, 84.1%, and 87.6%, respectively (all ps<0.05). Grayscale index showed higher sensitivity and negative predictive value (NPV) than US features. All diagnostic performances were higher for grayscale index than the elastography index. Area under the curve of US features was the highest, 0.762, but without significant differences to grayscale index or mean of elastography (all ps>0.05). Conclusion: Diagnostic performances were the highest for grayscale US features in diagnosis of DTD. Grayscale index may be used as a complementary tool to US features for improving sensitivity and NPV.

Fragility-based performance evaluation of mid-rise reinforced concrete frames in near field and far field earthquakes

  • Ansari, Mokhtar;Safiey, Amir;Abbasi, Mehdi
    • Structural Engineering and Mechanics
    • /
    • 제76권6호
    • /
    • pp.751-763
    • /
    • 2020
  • Available records of recent earthquakes show that near-field earthquakes have different characteristics than far-field earthquakes. In general, most of these unique characteristics of near-fault records can be attributed to their forward directivity. This phenomenon causes the records of ground motion normal to the fault to entail pulses with long periods in the velocity time history. The energy of the earthquake is almost accumulated in these pulses causing large displacements and, accordingly, severe damages in the building. Damage to structures caused by past earthquakes raises the need to assess the chance of future earthquake damage. There are a variety of methods to evaluate building seismic vulnerabilities with different computational cost and accuracy. In the meantime, fragility curves, which defines the possibility of structural damage as a function of ground motion characteristics and design parameters, are more common. These curves express the percentage of probability that the structural response will exceed the allowable performance limit at different seismic intensities. This study aims to obtain the fragility curve for low- and mid-rise structures of reinforced concrete moment frames by incremental dynamic analysis (IDA). These frames were exposed to an ensemble of 18 ground motions (nine records near-faults and nine records far-faults). Finally, after the analysis, their fragility curves are obtained using the limit states provided by HAZUS-MH 2.1. The result shows the near-fault earthquakes can drastically influence the fragility curves of the 6-story building while it has a minimal impact on those of the 3-story building.

Quantitative aspects of the hydrolysis of ginseng saponins: Application in HPLC-MS analysis of herbal products

  • Abashev, Mikhail;Stekolshchikova, Elena;Stavrianidi, Andrey
    • Journal of Ginseng Research
    • /
    • 제45권2호
    • /
    • pp.246-253
    • /
    • 2021
  • Background: Ginseng is one of the most valuable herbal supplements. It is challenging to perform quality control of ginseng products due to the diversity of bioactive saponins in their composition. Acid or alkaline hydrolysis is often used for the structural elucidation of these saponins and sugars in their side chains. Complete transformation of the original ginsenosides into their aglycones during the hydrolysis is one of the ways to determine a total saponin group content. The main hurdle of this approach is the formation of various by-products that was reported by many authors. Methods: Separate HPLC assessment of the total protopanaxadiol, protopanaxatriol and ocotillol ginsenoside contents is a viable alternative to the determination of characteristic biomarkers of these saponin groups, such as ginsenoside Rf and pseudoginsenoside F11, which are commonly used for authentication of P. ginseng Meyer and P. quinquefolius L. samples respectively. Moreover, total ginsenoside content is an ideal aggregated parameter for standardization and quality control of ginseng-based medicines, because it can be directly applied for saponin dosage calculation. Results: Different hydrolysis conditions were tested to develop accurate quantification method for the elucidation of total ginsenoside contents in herbal products. Linearity, limits of quantification, limits of detection, accuracy and precision were evaluated for the developed HPLC-MS method. Conclusion: Alkaline hydrolysis results in fewer by-products than sugar elimination in acidic conditions. An equimolar response, as a key parameter for quantification, was established for several major ginsenosides. The developed approach has shown acceptable results in the analysis of several different herbal products.