• Title/Summary/Keyword: Accuracy

Search Result 33,967, Processing Time 0.068 seconds

Validation of ENVI-met Model with In Situ Measurements Considering Spatial Characteristics of Land Use Types (토지이용 유형별 공간특성을 고려한 ENVI-met 모델의 현장측정자료 기반의 검증)

  • Song, Bong-Geun;Park, Kyung-Hun;Jung, Sung-Gwan
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.2
    • /
    • pp.156-172
    • /
    • 2014
  • This research measures and compares on-site net radiation energy, air temperature, wind speed, and surface temperature considering various spatial characteristics with a focus on land use types in urban areas in Changwon, Southern Gyeongsangnam-do, to analyze the accuracy of an ENVI-met model, which is an analysis program of microclimate. The on-site measurement was performed for three days in a mobile measurement: two days during the daytime and one day during the nighttime. The analysis using the ENVI-met model was also performed in the same time zone as the on-site measurement. The results indicated that the ENVI-met model showed higher net radiation than the on-site measurement by approximately $300Wm^{-2}$ during the daytime whereas the latter showed higher net radiation energy by approximately $200Wm^{-2}$ during the nighttime. The temperature was found to be much higher by approximately $2-6^{\circ}C$ in the on-site measurement during both the daytime and nighttime. The on-site measurement also showed higher surface temperature than the ENVI-met by approximately $7-13^{\circ}C$. In terms of the wind speed, there was a significant difference between the results of the ENVI-met model and on-site measurement. As for the correlation between the results of the ENVI-met model and on-site measurement, the temperature showed significantly high correlation whereas the correlations for the net radiation energy, surface temperature, and wind speed were very low. These results appear to be affected by excessive or under estimation of solar and terrestrial radiation and climatic conditions of the surrounding areas and characteristics of land cover. Hence, these factors should be considered when applying these findings in urban and environment planning for improving the microclimate in urban areas.

A Study on Qulity Perceptions and Satisfaction for Medical Service Marketing (의료서비스 마케팅을 위한 품질지각과 만족에 관한 연구)

  • Yoo, Dong-Keun
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.2 no.1
    • /
    • pp.97-114
    • /
    • 1996
  • INSTRODUCTION Service quality is, unlike goods quality, an abstract and elusive constuct. Service quality and its requirements are not easily understood by consumers, and also present some critical research problems. However, quality is very important to marketers and consumers in that it has many strategic benefits in contributing to profitability of marketing activities and consumers' problem-solving activities. Moreover, despite the phenomenal growth of medical service sector, few researchers have attempted to define and model medical service quality. Especially, little research has focused on the evaluation of medical service quality and patient satisfaction from the perspectives of both the provider and the patient. As competition intensifies and patients are demanding higher quality of medical service, medical service quality and patient satisfaction has emerged as a critical research topic. The major purpose of this article is to explore the concept of medical service quality and its evaluation from both nurse and patient perspectives. This article attempts to achieve its purpose by (1)classfying critical service attibutes into threecategories(satisfiers, hygiene factors, and performance factors). (2)measuring the relative importance of need criteria, (3)evaluating SERVPERF model and SERVQUAL model in medical service sector, and (4)identifying the relationship between perceived quality and overall patient satisfaction. METHOD Data were gathered from a sample of 217 patients and 179 nurses in Seoul-area general hospitals. From the review of previous literature, 50 survey items representing various facets of the medical service quality were developed to form a questionnaire. A five-point scale ranging from "Strongly Agree"(5) to "Strongly Disagree"(1) accompanied each statement(expectation statements, perception statements, and importance statements). To measure overall satisfaction, a seven-point scale was used, ranging from "Very Satisfied"(7) to "Very Dissatisfied"(1) with no verbal labels for scale points 2 through 6 RESULTS In explaining the relationship between perceived performance and overall satisfaction, only 31 variables out of original 50 survey items were proven to be statistically significant. Hence, a penalty-reward analysis was performed on theses 31 critical attributes to find out 17 satisfiers, 8 hygiene factors, and 4 performance factors in patient perspective. The role(category) of each service quality attribute in relation to patient satisfaction was com pared across two groups, that is, patients and nurses. They were little overlapped, suggesting that two groups had different sets of 'perceived quality' attributes. Principal components factor analyses of the patients' and nurses' responses were performed to identify the underlying dimensions for the set of performance(experience) statements. 28 variables were analyzed by using a varimax rotation after deleting three obscure variables. The number of factors to be extracted was determined by evaluating the eigenvalue scores. Six factors wereextracted, accounting for 57.1% of the total variance. Reliability analysis was performed to refine the factors further. Using coefficient alpha, scores of .84 to .65 were obtained. Individual-item analysis indicated that all statements in each of the factors should remain. On 26 attributes of 31 critical service quality attributes, there were gaps between actual patient's importance of need criteria and nurse perceptions of them. Those critical attributes could be classified into four categories based on the relative importance of need criteria and perceived performance from the perspective of patient. This analysis is useful in developing strategic plans for performance improvement. (1) top priorities(high importance and low performance) (in this study)- more health-related information -accuracy in billing - quality of food - appointments at my convenience - information about tests and treatments - prompt service of business office -adequacy of accommodations(elevators, etc) (2) current strengths(high importance and high performance) (3)unnecessary strengths(low importance and high performance) (4) low priorities(low importance and low performance) While 26 service quality attributes of SERPERF model were significantly related to patient satisfation, only 13 attributes of SERVQUAL model were significantly related. This result suggested that only experience-based norms(SERVPERF model) were more appropriate than expectations to serve as a benchmark against which service experiences were compared(SERVQUAL model). However, it must be noted that the degree of association to overall satisfaction was not consistent. There were some gaps between nurse percetions and patient perception of medical service performance. From the patient's viewpoint, "personal likability", "technical skill/trust", and "cares about me" were most significant positioning factors that contributed patient satisfaction. DISCUSSION This study shows that there are inconsistencies between nurse perceptions and patient perceptions of medical service attributes. Also, for service quality improvement, it is most important for nurses to understand what satisfiers, hygiene factors, and performance factors are through two-way communications. Patient satisfaction should be measured, and problems identified should be resolved for survival in intense competitive market conditions. Hence, patient satisfaction monitoring is now becoming a standard marketing tool for healthcare providers and its role is expected to increase.

  • PDF

Strength and Deformation Capacities of Short Concrete Columns with Circular Section Confined by GFRP (GFRP로 구속된 원형단면 콘크리트 단주의 강도 및 변형 능력)

  • Cho, Soon-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.121-130
    • /
    • 2007
  • To investigate the enhancement in strength and deformation capacities of concrete confined by FRP composites, tests under axial loads were carried out on three groups of thirty six short columns in circular section with diverse GFRP confining reinforcement. The major test variables considered include fiber content or orientation, wrap or tube type by varying the end loading condition, and continuous or discontinuous confinement depending on the presence of vortical spices between its two halves. The circumferential FRP strains at failure for different types of confinements were also investigated with emphasis. Various analytical models capable of predicting the ultimate strength and strain of the confined concrete were examined by comparing to observed results. Tests results showed that FRP wraps or tubes provide the substantial increase in strength and deformation, while partial wraps comprising the vertical discontinuities fail in an explosive manner with less increase in strength, particularly in deformation. A bilinear stress-strain response was observed throughout all tests with some variations of strain hardening. The failure hoop strains measured on the FRP surface were less than those obtained from the tensile coupons in all tests with a high degree of variation. In overall, existing predictive equations overestimated ultimate strengths and strains observed in present tests, with a much larger scatter related to the latter. For more accuracy, two simple design- oriented equations correlated with present tests are proposed. The strength equation was derived using the Mohr-Coulomb failure criterion, whereas the strain equation was based on entirely fitting of test data including the unconfined concrete strength as one of governing factors.

Nutrition Knowledge, Dietary Habits and Nutrition Attitudes of Elementary and Middle School Teachers in Masan City (마산시 초.충 교사들의 영양지식, 식생활 습관 및 영양태도)

  • 윤현숙;최윤선;이경혜
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.1
    • /
    • pp.160-169
    • /
    • 2002
  • This study was carried to investigate the nutrition knowledge, dietary habits and nutrition attitude of 227 teachers of elementary and middle school in Masan city. The survey was conducted by a self-administered questionnaire. The results showed that the subjects had a high level of perceived nutrition knowledge (85.2%), but the accuracy of the knowledge was 76.2%, and percentage of correct answers was 65.5%. The average nutrition knowledge score was 13.1 out of possible 20 points, the average score of dietary habits was 76.2 and nutrition attitudes score was 70.8 out of 100 points. Most of the subjects are belonged to the 'good'group in terms of nutrition knowledge, dietary habits and nutrition attitudes level. Female teachers scored significantly higher on nutrition knowledge and nutrition attitudes than male teachers did (p<0.001). And elementary school teachers scored significantly higher on dietary habits than noddle school teachers (p<0.01). There was a highly significant correlations between nutrition knowledge and nutrition attitude (r =0.3, p<0.001); dietary habit and nutrition attitude (r : 0.4, p<0.001). But the correlation between nutrition knowledge and dietary habits was not significant.

Performance Test of Portable Hand-Held HPGe Detector Prototype for Safeguard Inspection (안전조치 사찰을 위한 휴대형 HPGe 검출기 시제품 성능평가 실험)

  • Kwak, Sung-Woo;Ahn, Gil Hoon;Park, Iljin;Ham, Young Soo;Dreyer, Jonathan
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.54-60
    • /
    • 2014
  • IAEA has employed various types of radiation detectors - HPGe, NaI, CZT - for accountancy of nuclear material. Among them, HPGe has been mainly used in verification activities required for high accuracy. Due to its essential cooling component(a liquid-nitrogen cooling or a mechanical cooling system), it is large and heavy and needs long cooling time before use. New hand-held portable HPGe has been developed to address such problems. This paper deals with results of performance evaluation test of the new hand-held portable HPGe prototype which was used during IAEA's inspection activities. Radioactive spectra obtained with the new portable HPGe showed different characteristics depending on types and enrichments of nuclear materials inspected. Also, Gamma-rays from daughter radioisotopes in the decay series of $^{235}U$ and $^{238}U$ and characteristic x-rays from uranium were able to be remarkably separated from other peaks in the spectra. A relative error of enrichment measured by the new portable HPGe was in the range of 9 to 27%. The enrichment measurement results didn't meet partially requirement of IAEA because of a small size of a radiation sensing material. This problem might be solved through a further study. This paper discusses how to determine enrichment of nuclear material as well as how to apply the new hand-held portable HPGe to safeguard inspection. There have been few papers to deal with IAEA inspection activity in Korea to verify accountancy of nuclear material in national nuclear facilities. This paper would contribute to analyzing results of safeguards inspection. Also, it is expected that things discussed about further improvement of a radiation detector would make contribution to development of a radiation detector in the related field.

Validity of Long Form Assessment in Interactive Metronome® as a Measure of Children's Praxis (아동의 운동기능평가에 대한 Interactive Metronome® LFA의 타당도 연구)

  • Kim, Kyeong-Mi;Heo, Seo-Yoon;Kim, Mi-Su;Lee, Soo-Min
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.13 no.1
    • /
    • pp.13-22
    • /
    • 2015
  • Objective : The aim of this study is to verify validity of Long Form Assessment, which is an Interactive Metronome $measure^{(R)}$(LFA-IM), as a measurement of praxis of children. Methods : The study was implemented from March 2015 to July 2015. Twenty-five children with Attention Deficit Hyperactivity Disorder (ADHD) and those without ADHD (age of 6~11) were selected from a local university hospital and community in Gyeoung-Nam province and Busan for this study. In order to examine discriminative validity of LFA-IM, Bruininks-Oseretsky Test of Motor Proficiency, second edition (BOT-2) was used to compare the difference of results with LFA-IM for both children with- and without ADHD. For concurrent validity, correlation between LFA-IM and BOT-2 was investigated using spearman correlation coefficients. Results : For the comparison between children with ADHD and children without ADHD, there were significant differences in the total scores of LFA-IM (p<.05). Regarding the concurrent validity, there was a strong negative correlation between the total scores of LFA-IM and BOT-2 (p<.05). In addition, there was high correlation between LFA-IM and BOT-2 for the area of hand control (rs=-.532), and high negative correlation for the area of fine-motor accuracy (rs=-.447), hand dexterity (rs=-.532), and balance control (rs=-.623) (p<.05). Conclusion : This study identified validities of LFA-IM as an assessment of praxis of children. The results showed that it is appropriate to evaluate praxis of children with the total score of LFA-IM and, thus, it is believed that LFA-IM has a potential clinical utility. However, there should be more researches with large number of subjects.

A Polarization-based Frequency Scanning Interferometer and the Measurement Processing Acceleration based on Parallel Programing (편광 기반 주파수 스캐닝 간섭 시스템 및 병렬 프로그래밍 기반 측정 고속화)

  • Lee, Seung Hyun;Kim, Min Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.253-263
    • /
    • 2013
  • Frequency Scanning Interferometry(FSI) system, one of the most promising optical surface measurement techniques, generally results in superior optical performance comparing with other 3-dimensional measuring methods as its hardware structure is fixed in operation and only the light frequency is scanned in a specific spectral band without vertical scanning of the target surface or the objective lens. FSI system collects a set of images of interference fringe by changing the frequency of light source. After that, it transforms intensity data of acquired image into frequency information, and calculates the height profile of target objects with the help of frequency analysis based on Fast Fourier Transform(FFT). However, it still suffers from optical noise on target surfaces and relatively long processing time due to the number of images acquired in frequency scanning phase. 1) a Polarization-based Frequency Scanning Interferometry(PFSI) is proposed for optical noise robustness. It consists of tunable laser for light source, ${\lambda}/4$ plate in front of reference mirror, ${\lambda}/4$ plate in front of target object, polarizing beam splitter, polarizer in front of image sensor, polarizer in front of the fiber coupled light source, ${\lambda}/2$ plate between PBS and polarizer of the light source. Using the proposed system, we can solve the problem of fringe image with low contrast by using polarization technique. Also, we can control light distribution of object beam and reference beam. 2) the signal processing acceleration method is proposed for PFSI, based on parallel processing architecture, which consists of parallel processing hardware and software such as Graphic Processing Unit(GPU) and Compute Unified Device Architecture(CUDA). As a result, the processing time reaches into tact time level of real-time processing. Finally, the proposed system is evaluated in terms of accuracy and processing speed through a series of experiment and the obtained results show the effectiveness of the proposed system and method.

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF

Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy (자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2003
  • High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a phantom. In this study, the phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the phantom were then compared with the treatment planning system for the dose verification. The phantom needs to be designed such that the dose distributions can be quantitatively evaluated by utilizing the dosimeters with a high spatial resolution. Therefore, the small size of the thermoluminescent dosimeter (TLD) chips with a dimension of <1/8"and film dosimetry with a spatial resolution of <1mm used to measure the radiation dosages in the phantom. The phantom called a pelvic phantom was made from water and the tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators were inserted into the grooves of the applicator holder. The dose distributions around the applicators, such as Point A and B, were measured by placing a series of TLD chips (TLD-to-TLD distance: 5mm) in the three TLD holders, and placing three verification films in the orthogonal planes. This study used a Nucletron Plato treatment planning system and a Microselectron Ir-192 source unit. The results showed good agreement between the treatment plan and measurement. The comparisons of the absolute dose showed agreement within $\pm$4.0 % of the dose at point A and B, and the bladder and rectum point. In addition, the relative dose distributions by film dosimetry and those calculated by the planning computer show good agreement. This pelvic phantom could be a useful to verify the dose calculation algorithm and the accuracy of the image localization algorithm in the high dose rate (HDR) planning computer. The dose verification with film dosimetry and TLD as quality assurance (QA) tools are currently being undertaken in the Catholic University, Seoul, Korea.

  • PDF

A Comparison of Peripheral Doses Scattered from a Physical Wedge and an Enhanced Dynamic Wedge (금속쐐기와 기능강화동적쐐기의 조사야 주변부 선량 비교)

  • Park, Jong-Min;Kim, Hee-Jung;Min, Je-Soon;Lee, Je-Hee;Park, Charn-Il;Ye, Sung-Joon
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.107-117
    • /
    • 2007
  • In order to evaluate the radio-protective advantage of an enhanced dynamic wedge (EDW) over a physical wedge (PW), we measured peripheral doses scattered from both types of wedges using a 2D array of ion-chambers. A 2D array of ion-chambers was used for this purpose. In order to confirm the accuracy of the device we first compared measured profiles of open fields with the profiles calculated by our commissioned treatment planning system. Then, we measured peripheral doses for the wedge angles of $15^{\circ},\;30^{\circ},\;45^{\circ},\;and\;60^{\circ}$ at source to surface distances (SSD) of 80 cm and 90 cm. The measured points were located at 0.5 cm depth from 1 cm to 5 cm outside of the field edge. In addition, the measurements were repeated by using thermoluminescence dosimeters (TLD). The peripheral doses of EDW were (1.4% to 11.9%) lower than those of PW (2.5% to 12.4%). At 15 MV energy, the average peripheral doses of both wedges were 2.9% higher than those at 6MV energy. At a small SSD (80 cm vs. 90 cm), peripheral dose differences were more recognizable. The average peripheral doses to the heel direction were 0.9% lower than those to the toe direction. The results from the TLD measurements confirmed these findings with similar tendency. Dynamic wedges can reduce unnecessary scattered doses to normal tissues outside of the field edge in many clinical situations. Such an advantage is more profound in the treatment of steeper wedge angles, and shorter SSD.

  • PDF