• 제목/요약/키워드: Access Floor

검색결과 147건 처리시간 0.024초

지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구 (Comparative Study on Performance of Wet-type and Dry-type Floor Heating Systems Using Geothermal Heat Pump)

  • 이병두;이세진;이대우;오성해;남우동
    • 신재생에너지
    • /
    • 제5권4호
    • /
    • pp.60-65
    • /
    • 2009
  • The present study was conducted for a comparative evaluation of wet and dry floor heating systems using geothermal heat pump. We circulated hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.9^{\circ}C$ for wet type and $32.7^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. As a result, in case of floor heating system using low temperature circulation water, dry type was more practicable for stable floor heating than wet type in terms of floor temperature and access time to indoor set temperature.

  • PDF

무정전-무이설 방식의 전기판넬 내진보강시스템 시험연구 (Experimental Study of a Seismic Reinforcing System without Power Interruption and Movement for Electric Panel on the Access Floor)

  • 장정범;이종림;황경민;함경원
    • 한국지진공학회논문집
    • /
    • 제13권3호
    • /
    • pp.1-10
    • /
    • 2009
  • 본 연구에서는 전력, 통신 등 다양한 주요 기간설비의 운영에 필수적인 전기판넬의 내진성능개선을 위하여 내진보강시스템을 개발하고, 이 시스템의 내진성능평가를 위하여 진동대시험을 수행하였다. 본 연구에서 개발된 전기판넬 내진보강시스템은 이중바닥시스템(Access floor) 상에 설치된 전기판넬을 대상으로 운전하에서 무정전, 무이설 방식으로 내진보강이 가능하다는 장점을 지니고 있다. 진동대시험을 통해 전기판넬 내진보강시스템의 성능평가를 위하여 지진하중으로서 건물 내 여러 층에 설치되는 전기판넬의 특성을 고려하여 포괄응답스펙트럼을 입력하였다. 진동대시험은 널리 상용화되어 있는 스틸과 우드판넬 등 두 형식의 이중바닥시스템과 일반 전기판넬을 대표할 수 있는 동특성이 다른 두 종류의 전기판넬을 고려하여 총 4회 수행하였다. 진동대시험결과, 내진보강시스템은 진동대시험 중 및 후에도 전도 등으로 인한 전기판넬의 파손을 방지하는 등 전기판넬의 내진안전성을 확보하여 주는 것으로 나타났다. 따라서, 이중바닥시스템 상에 설치된 전기판넬에 개발된 내진보강시스템을 적용하는 경우, 지진으로 인한 전기판넬의 파손을 효과적으로 방지하여, 국내 주요 기간설비의 안정적 운영에 크게 기여할 수 있을 것으로 판단된다.

The Relationship Between Cage Floor Preferences and Performance in Broiler Chickens

  • Zulkifli, I.;Khatijah, A. Siti
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제11권3호
    • /
    • pp.234-238
    • /
    • 1998
  • Two experiments were conducted with broiler chickens to determine cage floor preferences, the strength of preference for a particular floor type and to evaluate the effect of rearing broilers on the preferred cage floor on productivity. In experiment 1, chicks when offered free access to either wire (WF) or plastic (PF) mesh flooring, preferred the former. However, when the perferred floor type (WF) was illuminated at 800 lux, birds spent longer time on PF. Also provision of incandescent lamps at PF resulted in broilers spending significantly longer period on WF. In experiment 2, while floor type had no effect on growth of female chicks throughout the duration of study, male chicks grown on PF were heavier than their WF counterparts on Days 21, 28, 35 and 42. Neither livability, nor incidence of breast blisters and leg deformities was affected by floor type.

A General Method for Error Probability Computation of UWB Systems for Indoor Multiuser Communications

  • Durisi, Giuseppe;Tarable, Alberto;Romme, Jac;Benedetto, Sergio
    • Journal of Communications and Networks
    • /
    • 제5권4호
    • /
    • pp.354-364
    • /
    • 2003
  • A general method for the evaluation of the symbol error probability (SER) of ultra wideband (UWB) systems with various kind of modulation schemes (N-PAM, M-PPM, Bi-Orthogonal), in presence of multipath channel, multiuser and strong narrowband interference, is presented. This method is shown to be able to include all the principal multiaccess techniques proposed so far for UWB, time hopping (TH), direct sequence (DS) and optical orthogonal codes (OOC). A comparison between the performance of these multiple access and modulation techniques is given, for both ideal Rake receiver and minimum mean square error (MMSE) equalizer. It is shown that for all the analyzed multiple access schemes, a Rake receiver exhibits a high error floor in presence of narrowband interference (NBI) and that the value of the error floor is in-fluenced by the spectral characteristics of the spreading code. As expected, an MMSE receiver offers better performance, representing a promising candidate for UWB systems. When the multiuser interference is dominant, all multiple access techniques exhibit similar performance under high-load conditions. If the number of users is significantly lower than the spreading factor, then DS outperforms both TH and OOC. Finally 2PPM is shown to offer better performance than the other modulation schemes in presence of multiuser interference; increasing the spreading factor is proposed as a more effective strategy for SER reduction than the use of time diversity.

공동주택 건축계획요소에 따른 전기 에너지 소비특성 분석 - 서울지역의 40평형(132~165㎡)의 단위세대 전기에너지 사용량을 중심으로 - (Analysis on Electricity Consumption Characteristics of Apartments based on Architectural Planning Factors - foused on Households with a total area of 132~165㎡ in Seoul-)

  • 박소윤;이윤재;이현수
    • KIEAE Journal
    • /
    • 제11권5호
    • /
    • pp.107-117
    • /
    • 2011
  • This paper aims to analyze architectural planning factors that could contribute to reductions in electricity consumption in the household of apartments, to apply energy saving methods at the design phase. These six architectural planning factors were orientation, building type (flat, tower block), standard floor access type (corridor access type, stair case type, EV hall access type), household location (floor), household opening type (one side opening, right angle opening, two sides opening or three sides opening), and bay on the facade (one bay, two bays, three bays, four bays), and these were derived from literature review. Household electricity consumption data were gathered from 2168 households with a total area of 135~150$m^2$ of 6 apartment complexes over 1000 households in Seoul. The annual characteristics of electricity consumption according to architectural planning factors were analyzed. And, variances between groups with respect to the mean of summer, winter, and annual electricity consumption according to each architectural planning factors were analyzed using ANOVA and t-test. The results showed that an annual electric energy saving of over 1000kWh was facilitated by these planning factors. In addition, high energy efficiency architectural planning factors based on the analysis were as follows: southwest orientation, flat type, corridor access type and staircase type, household loation below the 20th floor, two sides opening and three sides opening, and 2 bays and 3 bays.

Effect of the size of the bony access window and the collagen barrier over the window in sinus floor elevation: a preclinical investigation in a rabbit sinus model

  • Sim, Jeong-Eun;Kim, Sangyup;Hong, Ji-Youn;Shin, Seung-Il;Chung, Jong-Hyuk;Lim, Hyun-Chang
    • Journal of Periodontal and Implant Science
    • /
    • 제52권4호
    • /
    • pp.325-337
    • /
    • 2022
  • Purpose: The aim of this study was to investigate the effect of (1) the size of the bony access window and (2) collagen membrane coverage over the window in sinus floor elevation in a rabbit sinus model. Methods: Small bony access windows (SW; ø 2.8 mm) were made in 6 rabbits and large windows (LW; ø 6 mm) in 6 other rabbits. Both sinuses in each rabbit were allocated to groups with or without coverage of a collagen membrane (CM) on the window, resulting in 4 groups: SW, LW, SW+CM, and LW+CM. After 4 weeks of healing, micro-computed tomographic, histologic, and histomorphometric analyses were performed. Results: Bony healing in the window area was incomplete in all groups, but most bone graft particles were well confined in the augmented cavity. Histologically, the pattern of new bone formation was similar in all groups. Histomorphometrically, the percentage of newly formed bone was greater in the groups with CM than in the groups without CM, and in the groups with SW than in the groups with LW (12.92%±6.40% in the SW+CM group, 4.21%±7.73% in the SW group, 10.45%±4.81% in the LW+CM group, 11.77%±3.83% in the LW group). The above differences were not statistically significant (P>0.05). Conclusions: The combination of a small bony access window and the use of a collagen membrane over the window favored new bone formation compared to other groups, but this result should be further investigated due to the limitations of the present animal model.

근관치료의 시작 - 치수강 개방 (First step of root canal therapy-access cavity preparation)

  • 송민주
    • 대한치과의사협회지
    • /
    • 제56권10호
    • /
    • pp.572-580
    • /
    • 2018
  • Adequate access cavity is the key to achieving endodontic success. The aims of the access cavity can be considered as follows: 1) Creation of a smooth unimpeded pathway for instruments to canal orifices 2) Removal of the entire roof of the pulp chamber in order to inspect the pulp floor, 3) Preservation of natural tooth substance consistent with the above. Recently, contracted endodontic cavities based on minimally invasive endodontics has introduced. This has the benefit of preserving the pericervical dentin more than traditional access cavity with achieving long-term success. However, some studies reported controversial results regarding root canal detection, instrumentation efficacy (noninstrumented canal area, hard tissue debris accumulation, canal transportation, and centering ratio) as well as fracture resistance. Therefore, further studies are required for accepting contracted access cavity, and modified form of traditional and contracted access cavity could be considered.

  • PDF

철골조 고층 병원건물의 진동예측을 위한 동적특성 및 설계인자에 관한 연구 (The study on the dynamic characteristics of steel structure system for vibration estimation in hospital building)

  • 장강석;김영찬;안상경;나운
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.458-461
    • /
    • 2008
  • The primary objective of this study is to provide simple analytical tools to estimate dynamic characteristics of steel framed floor system in hospital building for vibration serviceability due to human activities, bogie, medical equipment. and so on. In order to evaluate the dynamic characteristics and vibration levels according to steel framed floor system, we had executed impact test and measurement on steel structure floor system in various hospital buildings. But perhaps most importantly, how to make the most of deduced design factor for design of hospital building. therefore we presented the access method such as the three-dimensional F.E. numerical analysis on the basis of the design drawing, and the properties of all floors for estimation of vibration level in hospital building.

  • PDF

한국형 저상버스 복합소재 차체에 대한 비틀림 강성 평가 (Torsion Rigidity of Composite Material Cmbody for Low Floor Bus)

  • 임송규;김연수;목재균;장세기;조세현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.548-553
    • /
    • 2008
  • Low Floor buses have no steps to get on or get off the main cabin to provide the old and the handicapped with easy access. The car body for the low floor bus was designed to consider Korean physical standard, passenger capacity (standee, seated, handicapped), arrangement of vehicle components, and bus law or regulations. It was designed as an one body, without any reinforcement armature, which has light-weight sandwich constructions with glass epoxy skins, aluminum honeycomb cores and inner-frames. In this paper, torsion rigidity of the designed car body was evaluated and compared with that of a car body with reinforcement armatures in the cabin. Finite element method verified that the designed car body without reinforcement armatures could satisfy requirements of torsion rigidity.

  • PDF

납-고무베어링을 적용한 제어장비의 동적 특성평가 (Dynamic Property Evaluation of Control Equipment using Lead Rubber Bearing)

  • 이경진;김갑순;서용표
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.341-348
    • /
    • 2002
  • In these days, The base isolation system is often used to improve the seismic capacity of the structures instead of conventional techniques of strengthening the structural members. The purpose of this study is to evaluate dynamic property evaluation of control equipment using lead Lead Rubber Bearing. In this study, a base isolation test of seismic monitoring control cabinet with LRB(lead rubber bearing) was performed. The cabinet will be installed on access floor in MCR(main control room) of nuclear power plant. Details and dynamic characteristics of the access floor were considered in the construction of testing specimen. N-S component of El Centre earthquake was used as seismic input motion. Acceleration response spectrums in the top of cabinets showed that the first mode frequency of cabinet with LRB(lead rubber bearing) was shifted to 7.5 Hz in compared with 18Hz of cabinet without LRB and the maximum peak acceleration was reduced in a degree of22 percent from 2.35 g to 1.84 g

  • PDF