• 제목/요약/키워드: Access Floor

검색결과 147건 처리시간 0.136초

악세스플로어(Access Floor)의 연소위험 소고

  • 이덕준;진영화
    • 방재기술
    • /
    • 통권16호
    • /
    • pp.24-27
    • /
    • 1994
  • This report is relevant to the fire-hazard implied in Access Floor being composed of combusti-ble materials. It emphasizes the importance of component materials and first-phased extinguishment for Ac-cess Floor with respect to fire-prevention.

  • PDF

폐지를 활용한 재생 플라스틱 (Composite Material made of Recycling Paper and Plastics)

  • 윤승원;이장용;김윤식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.697-702
    • /
    • 2002
  • Composite material made of recycling paper and plastics was developed. The tension and bending testing result of developed composite material shows that the cellulose contained in paper contributes much to get high flexural rigidity. As an application example, the raised access floor for office automation purpose was developed by making use of developed composite material. Manufacturing process together with the extrusion die and the compression die for to manufacture the access floor have been developed.

  • PDF

지속가능형 공동주택 구현을 위한 건식온돌 이중바닥 시스템 개발 (A study on development of dry ondol access floor system for sustainable apartment)

  • 오진균;손장열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.689-689
    • /
    • 2010
  • Since the apartment was built by Korea National Housing Cooperation in 1961, the amount of its supply has been increased greatly, especially from the late 70's. Recently there are many ongoing studies regarding sustainable construction apartment in Korea, one of the research is developing sustainable apartment that has longer life cycle. Also according as life's quality of residents is upgrading, complain for impact noise and plumbing system noise from upstair or downstair are increasing more and more. To solve this complains, government established impact noise standard as lightweight impact noise of 58dB, heavyweight impact noise of 50dB and presented standard floor system or recognition floor system to satisfy this impact noise standard. So in this study, the aim is to develop dry ondol access floor system for sustainable apartment which have pleasant and quiet life environment.

  • PDF

다층 건물을 위한 Wi-Fi 기반의 저 복잡도 층간 위치 측위 기법 (Wi-Fi-Based Low-Complexity Floor Number Determination Method Based for Multistory Buildings)

  • 석건;리향;정홍규;김진오;신요안
    • 대한기계학회논문집A
    • /
    • 제38권2호
    • /
    • pp.149-156
    • /
    • 2014
  • 최근 들어, 다층 건물 내 층간 위치 측위(Floor Determination)는 다양한 위치 기반 응용 서비스를 만족하기 위해 빠르게 해결해야 되는 문제가 되었다. 본 논문에서는 다층 건물 환경에서 Wi-Fi 신호를 기반으로 한 저복잡도 층간 위치 측위 기법을 제안한다. 제안 기법에서는 WAP(Wireless Access Point)에 대한 자세한 좌표 정보가 필요 없이, 사용자 단말기에 나온 각 WAP의 층수와 각 WAP의 수신 신호 세기(Received Signal Strength) 값만을 이용한다. 제안 기법의 성능을 검증하기 위해 본 논문에서는 Multi-Wall-Floor 모델을 사용하였으며, 모의실험 결과를 통해 각층의 WAP 배치 밀도가 충분히 높을 경우 제안 기법의 정확도가 100%에 도달함을 보였다. 그리고 각층의 WAP 수가 적은 경우에서도 우수한 층간 위치 측위 성능을 보였으며, 특히 심지어 WAP 가 하나도 없는 층이 있어도 층간 위치 측위가 가능한 것을 보임으로써 제안된 기법의 우수성을 확인하였다.

지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구 (A Study on Comparison of Capacity between Wet.Dry Floor Heating Systems Using Geothermal Heat Pump)

  • 이병두;이세진;이대우;오성해;남우동
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.567-570
    • /
    • 2009
  • The present study conducted comparative evaluation of wet dry floor heating systems using geothermal heat pump. Circulation hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler was used. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.89^{\circ}C$ for wet type and $32.66^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. In the results, for floor heating system using low temperature circulation water, wet type was not enough to meet stable and comfortable radiant floor heating due to low floor temperature and access time to indoor set temperature. While dry type was practicable for stable floor heating due to fast rise of indoor set temperature and comfortable floor temperature.

  • PDF

제연구역 출입문의 최적 설계를 위한 도어클로저의 기준 산정에 관한 연구 (Study on the Assessment of the Criteria on a Door Closer for the Optimum Design of the Access Door of a Smoke Control Zone)

  • 이재오;최충석
    • 한국화재소방학회논문지
    • /
    • 제27권3호
    • /
    • pp.66-71
    • /
    • 2013
  • 본 연구의 목적은 제연구역 출입문의 최적 설계를 위한 플로어힌지(floor-hinge) 및 도어클로저(door closer)의 기준을 제시하는데 있다. 차압에 대한 개방력은 60 Pa일 때 60.75 N, 40 Pa일 때 40.5 N, 32.5 Pa일 때 32.91 N, 12.5 Pa일 때 12.66 N 등이다. KS F 2806의 기준을 적용한 플로어힌지 및 도어클로저의 개방력은 No.1은 27.5 N, No. 2는 40 N, No. 3는 75 N, No. 4는 100 N, No. 5는 125 N 등이다. 차압과 플로어힌지 및 도어클로저의 개방력을 NFSC 501A의 개방력 제한값과 비교한 결과 기준을 초과하는 것으로 확인되었다. 따라서 NFSC 501A 차압과 방연 풍속을 설계에 반영하는 것뿐만 아니라 개방력도 설계에 반영할 필요가 있다. 제연댐퍼의 종류에 따라 출입문의 플로어힌지 및 도어클로저의 설치 조건은 호칭에 따라 다르다. 저차압용의 경우는 No. 1, No. 2, No. 3의 설치가 가능하며, 일반 차압용의 경우에는 No. 1, No. 2의 설치가 가능하였다.

철근 콘크리트 구조물의 Access Floor 수평진동 제어를 위한 실험 및 해석 (Experiment and Analysis for the Horizontal Vibration Control of Access Floor on Reinforced Concrete Structures)

  • 변근주;김문겸;송하원;이호범
    • 한국지진공학회논문집
    • /
    • 제1권1호
    • /
    • pp.31-39
    • /
    • 1997
  • 본 논문은 철근 콘크리트(RC) 격자보위에 설치된 access floor 에 발생하는 진동 중 수평방향 진동을 제어하기 위해 정밀 스프링 댐퍼를 이용한 실험을 이용한 실험을 통하여 수평진동 방진 시스템을 개발하였고, 대상 구조물의 진동해석을 위한 모델링과 그에 따른 해석을 수행하였다. 설계된 스프링 댐버 시스템의 방진효과를 알아보기 위하여 모형구조물에 댐퍼를 설치하지 않은 경우, 설피시 댐버를 pedestal과 pedestal에 연결하여 설치한 경우 그리고 pedestal과 격자보에 연결하여 설치한 경우로 나누어 실험을 실시하였다. 각각의 경우에 대해 충격 가진 및 외부 진동을 가해 슬래브와 access floor에서의 가속도 응답을 측정하였다. 실험결과 댐퍼를 설치한 경우에 공진 응답은 댐퍼가 없는 경우에 비해 응답크기가 감소하고, 공진 최대치도 부분적으로 저진동수 대역으로 이동하는 경향으로 나타났다. 또한 저진동수 대역에서 보다는 고진동수 대역에서 가속도 성분의 감소가 크게 나타나고 있고, 특히 외부 진동에 대해서는 상당한 효과가 있다는 것을 알 수 있었다. 대상 구조물의 진동해석을 유한요소법에 의해 실시 하였으며 해석을 통해서도 스프링 댐퍼 시스템의 방진효과를 확인할 수 있었고, 실험과 해석의 결과가 잘 일치함을 알 수 있었다. 따라서 본 연구는 정밀 방.제진 시스템 및 미진동 제어 콘크리트 구조물 설계를 위해 유용하게 이용될 수 있으리라 판단된다.

  • PDF

하부 플레넘 구조물 조건을 고려한 클린룸의 편류 개선 방법 (Improving Vertical Airflow Uniformity Considering the Structures of the Lower Plenum in a Cleanroom)

  • 김영섭;하만영
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.17-25
    • /
    • 2008
  • To achieve the unidirectional airflow in a cleanroom, we need to predict accurately the static pressure losses at the lower plenum and to control properly the opening pressure ratio of access floor panels based on these pressure losses. At first, the present study proposed a correlation to predict the velocity distribution at the lower plenum, because the accuracy to predict pressure losses at the lower plenum depends on how to calculate the velocity correctly against the inner structures at the lower plenum. In the second place, this study proposed correlations which considered the effect of inner structures such as columns, ducts and equipments at the lower plenum on pressure losses. In order to test the accuracy of these correlations, we compared air flow patterns before regulating the opening ratio of access floor with those after regulating. Results after regulating the opening ratio of access floor show good unidirectional uniform airflow pattern. So the present method can be used as an important tool to control the air flow in a cleanroom.