• 제목/요약/키워드: Accelerated Aging Test

검색결과 229건 처리시간 0.031초

복합 가속열화를 통한 배전용 고분자 피뢰기의 장기 열화특성 예측 (Longterm Aging Characteristics of Distribution Polymer Housed Surge Arresters by Multistress Accelerated Aging)

  • 김주용;권태호;박철배;김준일
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.691-696
    • /
    • 2007
  • In this study accelerated aging test equipment was developed to simulate domestic weather condition for accelerated aging test of polymer housed distribution surge arresters. Polymer arresters were aged for 3,000 hours by this test equipment and chemical and electrical characteristics analysis of surge arresters were conducted after aging test. In addition, performance assessment of outdoor installed arresters for 3 years was conducted to compare aging effect between accelerated aging test and natural aging. Through this experiment it is verified that the capability of the proposed aging test for simulating natural aging and the housing material and disconnector of domestic polymer arresters can be deteriorated by the long time field operation.

가속열화시험에 의한 폴리머애자의 신뢰성 평가 (Reliability Assessment of Polymer Insulators by Accelerated Aging Test)

  • 한채홍;이병성;정종욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.10-14
    • /
    • 2001
  • In order to assess the long-tenn reliability of polymer insulators for distribution power systems, we have developed the accelerated aging test method which can simulate the operation conditions. In this study, 3000 hours aging test for 4 kinds of polymer insulators has been completed by the developed accelerated aging test. After 3000 hours aging test, visual inspection and electrical tests were carried for identifying a change of characteristics. Some specimens showed the surface erosion and the manufacturing defect. In the electrical tests, the wet flashover voltage was significant1y decreased by the accelerated aging test. In comparison with the field-aged polymer insulators, it can be concluded that the developed test method can evaluate the long-tenn reliability within short time and screen the manufacturing defect.

  • PDF

광통신용 1.25Gbps Transceiver 가속수명시험 (Accelerated Life Test for 1.25Gbps Transceiver)

  • 윤광수;유정희;허영순
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1391-1393
    • /
    • 2008
  • In this paper, the long-term reliability for 1.25G transceiver in use of high speed optical access network is investigated. High temperature storage tests and accelerated life tests are used to long-term reliability. Accelerated aging test have been during 3,000 hour of the three accelerated aging conditions by caused high temperature stress. Mean life is assumed to follow the Arrhenius relationship and analysis from the failure data obtained in the accelerated aging conditions.

  • PDF

차수형 케이블의 수트리 가속실험후 와이블분포 해석 (The Analysis of Weibull Distribution after an Accelerated Aging Test of MV Cable)

  • 김진국;임장섭;송일관;이재봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.178-181
    • /
    • 2003
  • For many years, testing laboratories, research institutes and manufactures try to find a reliable water tree accelerated ageing test that is able to show whether a polymer Medium Voltage cable os susceptible to water treeing or not. Test on laboratory samples, model cable designs, and fell size cable are presented Apart form aging, another important aspect of any accelerated aging test is the right choice of th preconditioning method. This paper is the analysis of weibull distribution method after an accelerated aging test of MV(Medium Voltage) cable.

  • PDF

배전케이블의 수트리 가속열화 후 와이블분포 해석 (The Analysis of Weibull Distribution after an Accelerated Aging Test of MV Cable)

  • 김진국;임장섭;송일근;김주용;이우선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 영호남 학술대회 논문집
    • /
    • pp.7-11
    • /
    • 2003
  • for many years already, testing laboratories, research institutes and manufactures try to find a reliable water tree accelerated ageing test that is able to show whether a polymer Medium Voltage cable os susceptible to water treeing or not. Test on laboratory samples, model cable designs, and fell size cable are presented. Apart form aging, another important aspect of any accelerated aging test is the right choice of th preconditioning method. THTS paper is the analysis of weibull distribution method after an accelerated aging test of MV(Medium Cable) cable.

  • PDF

BD-R 장기보존 특성 평가를 위한 가속 열화 실험 조건과 안정성 평가 기준에 관한 연구 (A Study on Suitable Condition of Accelerated Aging Test and Evaluation Criteria of Data Stability for Archival Performance Analysis of BD-R media)

  • 이관용;박선주;김도현;조이형;김영주
    • 정보저장시스템학회논문집
    • /
    • 제10권1호
    • /
    • pp.7-13
    • /
    • 2014
  • The Blu-ray Disc Recordable(BD-R) is one of strong candidates for archival application among optical media formats, because of its large capability. However, the well-defined accelerated aging test conditions and evaluation criteria have not yet been fully confirmed for BD-R. In this study, the data stability and degradation aspect of BD-R were analyzed by the random-symbol error rate(R-SER) measurement after the accelerated aging test. And a reasonable test condition of accelerated aging for BD-R and the appropriate evaluation criterion using R-SER measurement were discussed.

가속열화시험에 의한 18kV ZnO 피뢰기의 누설 전류 특성 분석 (Leakage Current Characteristics of 18kv ZnO Lightning Arresters by Accelerated Aging Test)

  • 김주용;송일근;김찬영;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.62-67
    • /
    • 2002
  • This paper provides the results of accelerated aging test of 18kV ZnO lightning arresters to investigate the leakage current characteristics. It was impossible to establish the replacement criterion for field operating lightning arrester because conventional aging test was only focused on the aging of ZnO elements. In general, it is possible to replace the aged arresters before the failure in the field using the leakage current measurement because it must be increased by the aging. But we can not use the method because we don't know the characteristics of the installed lightning arresters. Therefore in this paper we applied operating voltage and accelerating cycle which consists of temperature and humidity to the arresters. Then we measured the variation of total and resistive leakage current and found out the characteristics of the acted lightning arresters.

폴리머 피뢰기 가속열화 방법과 열화특성 분석 (Accelerated aging test method and characteristics analysis of polymer housed surge arresters)

  • 김주용;박철배;권태호;정연하
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.210-213
    • /
    • 2007
  • In this study accelerated aging test cycle and equipment was developed for aging test of polymer housed surge arresters under domestic weather condition In order to investigate aging characteristics of polymer surge arresters electrical and chemical analysis of the arresters which are used for accelerated aging test and outdoor exposure test were conducted. Through the analysis the capability of the proposed method was verified and characteristics data were presented for maintenance of domestic arresters. Based on these results long term reliability assessment method was proposed for polymer housed distribution surge arresters.

  • PDF

가속 열 열화에 따른 환경친화형 변압기 절연물의 전기적-기계적 특성 분석 (Analyses on Electrical-Mechanical Characteristics of Environment-friendly Transformer Insulating Material by Accelerated Thermal Aging)

  • 심명섭;안정식;최순호;정중일;이태호;허창수
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1832-1838
    • /
    • 2010
  • Aging of transformer insulating material in natural ester insulating oil is compared to that in conventional transformer oil. Aging of insulating paper and insulating oil have been studied by performing accelerated thermal aging test. Sealed aging test vessels containing cooper, laminated core, Kraft paper and insulating oil(natural oil or mineral oil) were aged at $140^{\circ}C$ for 500, 1000, 1500 and 2000 hours. Insulating oils after aging are investigated with total acid number, breakdown voltage and viscosity. Also, degradation of insulating paper after aging is determined using breakdown voltage and mechanical strength. Accelerated aging studies demonstrate a slower aging rate for natural ester insulating oil compared to the rate for conventional mineral oil.

Evaluation of Nuclear Plant Cable Aging Through Condition Monitoring

  • Kim, Jong-Seog;Lee, Dong-Ju
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.475-484
    • /
    • 2004
  • Extending the lifetime of a nuclear power plant [(hereafter referred to simply as NPP)] is one of the most important concerns in the global nuclear industry. Cables are one of the long-life items that have not been considered for replacement during the design life of a NPP. To extend the cable life beyond the design life, it is first necessary to prove that the design life is too conservative compared with actual aging. Condition monitoring is useful means of evaluating the aging condition of cable. In order to simulate natural aging in a nuclear power plant. a study on accelerated aging must first be conducted. In this paper, evaluations of mechanical aging degradation for a neoprene cable jacket were performed after accelerated aging under tcontinuous and intermittent heating conditions. Contrary to general expectations, intermittent heating to the neoprene cable jacket showed low aging degradation, 50% break-elongation, and 60% indenter modulus, compared with continuous heating. With a plant maintenance period of 1 month after every 12 or 18 months operation, we can easily deduce that the life time of the cable jacket of neoprene can be extended much longer than extimated through the general EQ test. which adopts continuous accelerated aging for determining cable life. Therefore, a systematic approach that considers the actual environment conditions of the nuclear power plant is required for determining cable life.