• 제목/요약/키워드: Abutment geometry

검색결과 17건 처리시간 0.027초

Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections

  • Siadat, Hakimeh;Beyabanaki, Elaheh;Mousavi, Niloufar;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.271-277
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS. Two regular platform dental implants, one with external connection ($Br{\aa}nemark$, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at ${\alpha}=0.05$ of significance. RESULTS. There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups (P<.001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom (P<.001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments (P<.001). However, neither connection type (P=.15) nor abutment material (P=.38) affected torque loss. CONCLUSION. Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values.

Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation

  • Rodiger, Matthias;Rinke, Sven;Ehret-Kleinau, Fenja;Pohlmeyer, Franziska;Lange, Katharina;Burgers, Ralf;Gersdorff, Nikolaus
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.233-240
    • /
    • 2014
  • PURPOSE. To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS. Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: $5.7^{\circ}$; customized-long, height: 6.79 mm, taper: $4.8^{\circ}$; customized-short, height: 4.31 mm, taper: $4.8^{\circ}$) were used for luting of CAD/CAM-fabricated zirconia copings with a semi-permanent (Telio CS) and a provisional cement (TempBond NE). Retention forces were evaluated using a universal testing machine. Furthermore, the influence of cleaning methods (manually, manually in combination with ultrasonic bath or sandblasting) prior to re-cementation with a provisional cement (TempBond NE) was investigated with the pre-fabricated titanium abutments (height: 7.5 mm, taper: $5.7^{\circ}$) and SEM-analysis of inner surfaces of the copings was performed. Significant differences were determined via two-way ANOVA. RESULTS. Significant interactions between abutment geometry and luting agent were observed. TempBond NE showed the highest level of retentiveness on customized-long abutments, but was negatively affected by other abutment geometries. In contrast, luting with Telio CS demonstrated consistent results irrespective of the varying abutment geometries. Manual cleaning in combination with an ultrasonic bath was the only cleaning method tested prior to re-cementation that revealed retentiveness levels not inferior to primary cementation. CONCLUSION. No superiority for one of the two cements could be demonstrated because their influences on retentive strength are also depending on abutment geometry. Only manual cleaning in combination with an ultrasonic bath offers retentiveness levels after re-cementation comparable to those of primary luting.

내부연결방식 임플랜트 시스템의 삼차원 유한요소법적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF INTERNALLY CONNECTED IMPLANT SYSTEMS)

  • 김유리;조혜원;이재봉
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.85-102
    • /
    • 2006
  • Statement of problem: Currently, there are some 20 different geometric variations in implant/abutment interface available. The geometry is important because it is one of the primary determinants of joint strength, joint stability, locational and rotational stability. Purpose: As the effects of the various implant-abutment connections and the prosthesis height variation on stress distribution are not yet examined this study is to focus on the different types of implant-abutment connection and the prosthesis height using three dimensional finite element analysis. Material and method. The models were constructed with ITI, 3i TG, Bicon, Frialit-2 fixtures and solid abutment, TG post, Bicon post, EstheticBase abutment respectively. And the super structures were constructed as mandibular second premolar shapes with 8.5 mm, 11 mm, 13.5 mm of crown height. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the central pit of an occlusal surface. von Mises stresses were recorded and compared in the crowns, abutments, fixtures. Results: 1. Under the oblique loading, von Mises stresses were larger in the crown, abutment, fixture compared to the vertical loading condition. 2. The stresses were increased proportionally to the crown height under oblique loading but showed little differences with three different crown heights under vertical loading. 3. In the crown, the highest stress areas were loading points under vertical loading, and the finish lines under oblique loading. 4. Under the oblique loading, the higher stresses were located in the fixture/abutment interface of the Bicon and Frialit-2 systems compared to the ITI and TG systems. Conclusions: The stress distribution patterns of each implant-abutment system had difference among them and adequate crown height/implant ratio was important to reduce the stresses around the implants.

내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구 (FIT OF FIXTURE/ABUTMENT INTERFACE OF INTERNAL CONNECTION IMPLANT SYSTEM)

  • 이흥태;정재헌
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.192-209
    • /
    • 2004
  • Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.

Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments

  • Safari, Sina;Ghavam, Fereshteh Hosseini;Amini, Parviz;Yaghmaei, Kaveh
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권1호
    • /
    • pp.1-7
    • /
    • 2018
  • PURPOSE. The aim of this study was to evaluate the effects of abutment diameter, cement type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. MATERIALS AND METHODS. Sixty abutments with two different diameters, the height of which was reduced to 3 mm, were vertically mounted in acrylic resin blocks with matching implant analogues. The specimens were divided into 2 diameter groups: 4.5 mm and 5.5 mm (n=30). For each abutment a CAD/CAM metal coping was manufactured, with an occlusal loop. Each group was sub-divided into 3 sub-groups (n=10). In each subgroup, a different cement type was used: resin-modified glass-ionomer, resin cement and zinc-oxide-eugenol. After incubation and thermocycling, the removal force was measured using a universal testing machine at a cross-head speed of 0.5 mm/min. In zinc-oxide-eugenol group, after removal of the coping, the cement remnants were completely cleaned and the copings were re-cemented with resin cement and re-tested. Two-way ANOVA, post hoc Tukey tests, and paired t-test were used to analyze data (${\alpha}=.05$). RESULTS. The highest pulling force was registered in the resin cement group (414.8 N), followed by the re-cementation group (380.5 N). Increasing the diameter improved the retention significantly (P=.006). The difference in retention between the cemented and recemented copings was not statistically significant (P=.40). CONCLUSION. Resin cement provided retention almost twice as strong as that of the RMGI. Increasing the abutment diameter improved retention significantly. Re-cementation with resin cement did not exhibit any difference from the initial cementation with resin cement.

알칼리-골재반응에 의한 콘크리트 포장 팽창과 그에 따른 교량손상 감소방안 (Concrete Pavement Expansion due to Alkali-Aggregate Reaction and Damage Prevention of Bridges)

  • 우정원;임성순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권5호
    • /
    • pp.67-73
    • /
    • 2017
  • 고속도로에서 콘크리트 포장의 알칼리-골재반응 발생 구간이 증가하고 있다. 알칼리-골재반응이 발생한 콘크리트 포장은 팽창하면서 인접 교량에 교대 변위를 발생시켜 다수의 손상을 발생시키고 있다. 현장 조사 결과 콘크리트 포장의 팽창량은 온도 신축에 의한 팽창률을 상회하면서 교량에 치명적인 하중으로 작용하고 있어 손상 방지를 위한 선제적인 조치가 필요하다. 알칼리-골재 반응에 의한 팽창 정도는알칼리-골재반응의 상태, 포장의 길이 및 도로구조에 따라 달라짐을 알 수 있었다. 교량의 손상 방지를 위해선 콘크리트 포장의 팽창력을 이완시켜 주는 방안이 효과적이며 콘크리트 포장의 길이가 긴 구간은 아스팔트 치환공법이 유리할 것이다.

유한 요소법을 이용한 수종 심미 수복물의 응력 분석 (STRESS ANALYSIS OF VARIOUS ESTHETIC RESTORATIONS BY FINITE ELEMENT METHOD)

  • 조진희;방몽숙
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.129-145
    • /
    • 1991
  • The purpose of this study was to analyze the stresses and displacements of various esthetic restorations and abutment teeth. The finite element models of central incisor were divided into four groups according to the types of restoration. Three load cases were applied; 1) 45 degrees on the incisal edge, 2) horizontal force on the labial surface, and 3) 26 degrees diagonally on the lingual surface. Material property, geometry, and load conditions of each model were inputed to the two dimensional finite element program and stresses and displacements were analyzed. Results were as follows; 1. In the cases of porcelain fused gold ann and porcelain laminate venner, stresses were equally distributed in supporting abutment tooth. 2. The metal coping of porcelain fused gold u and collarless porcelain fused gold crown functioned as a good stress distributor. 3. When the horizontal load applied, the highest tensile and compressive stresses were seen in the cervical margin of restoration and the dentin of the abutment tooth. 4. The highest displacement of restoration was seen when load was applied at an mee of 26 degrees diagonally in lingual surface of tooth in centric occlusion. 5. The influence of loading direction on the stresses and displacements in the restoration was greater than that of various design. 6. The possibility of fracture was highest in porcelain jacket crown.

  • PDF

순수형 보강토교대의 슬래브교에 대한 적용성 및 외적/내적 안정성 검토 (A Study on Applicability and External / Internal Stability of true MSEW abutment with slab)

  • 박민철
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.263-274
    • /
    • 2018
  • 본 연구에서는 순수형 보강토교대의 상부구조로 적용되는 슬래브교에 대한 적용성을 검토하고 보강토 교대의 외적/내적 안정성에 대해 검토하였다. 상부구조인 슬래브교의 연장은 10.0 m ~ 20.0 m, 두께는 0.7 m ~ 0.9 m를 대상으로 하여 구조해석을 수행하여 보강토교대의 교량받침에 작용되는 사하중과 활하중에 의한 반력을 산정하였다. 슬래브교는 연장 20.0m까지 순수형 보강토교대의 허용 접지압 200 kPa을 만족하였다. 순수형 보강토교대의 외적 안정성은 보강토체의 기하형상에 지배되기 때문에 상부구조의 하중에 의한 안전율 변화는 작은 것으로 나타났다. 지지력에 대한 안전율은 기초지반의 강성은 상수이지만 활동력인 상부구조의 하중은 증가되므로 감소되었다. 그리고 상부구조로 인해 보강토옹벽 상단에 작용하는 접지압이 200 kPa을 초과할 경우, 순수형 보강토교대에서는 전면벽체에 작용하는 수평토압이 과도하게 증가되어, 최상단 보강재에서 내적안정성인 인발과 파단에서 허용안전율을 만족하지 못하였다. 순수형 보강토교대의 효율적 설계 및 성능 확보를 위해서는 보강토체 상단에 배치된 보강재의 인발저항력과 장기허용인장력을 증가시키는 것이 필요한 것으로 분석된다.

프리팹 교량의 DfMA를 위한 디지털엔지니어링 모델 정의 (Definition of Digital Engineering Models for DfMA of Prefabricated Bridges)

  • 두이-쿠엉 응구옌;노기태;심창수
    • 한국BIM학회 논문집
    • /
    • 제12권1호
    • /
    • pp.10-22
    • /
    • 2022
  • Prefabricated bridges require strict management of tolerance during fabrication and assembly. In this paper, digital engineering models for prefabricated bridge components such as deck, girder, pier, abutment are suggested to support information delivery through the life-cycle of the bridge. Rule-based modeling is used to define geometry of the members considering variable dimensions due to fabrication and assembly error. DfMA(design for manufacturing and assembly) provides the rules for ease of fabrication and assembly. The digital engineering model consists of geometry, constraints and corresponding parameters for each phase. Alignment and control points are defined to manage tolerances of the prefabricated bridge during fabrication and assembly. Quality control by digital measurement of dimensions was also considered in the model definition. A pilot bridge was defined virtually to validate the suggested digital engineering models. The digital engineering models for DfMA showed excellent potential to realize prefabricated bridges.

발치된 치아에 부착된 수복물의 변연 적합 및 형태 (Marginal dicrepancy and topography of the artificial crown on the extracted abutment)

  • 이정훈;최민호;김민호;강동완
    • 구강회복응용과학지
    • /
    • 제18권4호
    • /
    • pp.313-320
    • /
    • 2002
  • The purpose of the present study was to evaluate the marginal discrepancy and topography of artificial crown on teeth extracted due to severe periodontal disease. Twenty specimens were invested into metamethylacrylate resin and cutted into vertical slices along with the long axis of tooth. The selected marginal discrepancy between the outer edge of the crown and the finishing line of abutment was examined by stereo- microscope(Olympus, PM-VSP-3, Japan) at magnification of up to 10, and the topography of finishing margin on crown was observed by stereomicroscopeat magnification of up to $70{\times}$. The results were as follows. (1) The mean marginal discrepancy between extracted tooth and artificial crown were $50.82{\mu}m$. (2) There was a considerable difference in the microstructure of finishing margins among specimens. Microscopic Structure on finishing margin showed indefinite line, poor fit (open, underextended and overextended), distorted margin, and surface roughness. This study suggested that there could be necessary to consider the response of periodontium to the emergence profile of natural tooth and precision of marginal geometry while establishing treatment planning for the reconsruction of the artificial crown.