• 제목/요약/키워드: Abutment displacement

검색결과 88건 처리시간 0.026초

교량구조물의 측방이동 측정방법에 관한 연구 (The Measurement Method of Lateral Displacement in Bridge Abutment.)

  • 장용채
    • 한국항만학회지
    • /
    • 제14권1호
    • /
    • pp.115-124
    • /
    • 2000
  • This study is a suggest a measurement method of lateral displacement, which can be used to judge the stability of bridge abutment on soil undergoing lateral movement. The abutment of bridge on soft foundation makes lateral movement due to the settlement of back fill and lateral flow. To measure the displacement of such a abutment, there are a lot of indirect method for measurement such as survey of leveling or inclinometer gauge around the abutment. But all of them are not sufficient to confirm the ground behavior and measure the exact lateral behavior of structure. As making the structure and pile cooperatively by measuring the movement of lateral displacement, for measuring the abutment displacement precisely by using the inclinometer. In this work, we try to suggest efficient measuring method of abutment displacement and its application.

  • PDF

Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study

  • Kim, Sung-Jun;Son, KeunBaDa;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.388-394
    • /
    • 2018
  • PURPOSE. To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS. Twenty models of missing mandibular left second premolars were 3D-printed and implant fixtures were placed at the same position by using a surgical guide. External and internal fixtures were used. Three implant-abutment internal connection (INT) types and one implant-abutment external connection (EXT) type were prepared. Two of the INT types used titanium abutment and zirconia abutment; the other INT type was a customized abutment, fabricated by using a computer-controlled milling machine. The EXT type used titanium abutment. Screws were tightened at $10N{\cdot}cm$, simulating hand tightening, and then at the manufacturers' recommended torque ($30N{\cdot}cm$) 10 min later. Abutments and adjacent teeth were subsequently scanned with a contact scanner for 2D and 3D analyses using a 3D inspection software. RESULTS. Significant differences were observed in axial displacement according to the type of implant-abutment connection (P<.001). Vertical displacement of abutments was greater than overall displacement, and significant differences in vertical and overall displacement were observed among the four connection types (P<.05). CONCLUSION. Displacement according to connection type and material should be considered in choosing an implant abutment. When adjusting a prosthesis, tightening the screw at the manufacturers' recommended torque is advisable, rather than the level of hand tightening.

경사계를 이용한 교대변위 계측에 관한 연구 (The Measurement of Lateral Displacement of Abutment Using a Inclinometer)

    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 춘계학술대회논문집
    • /
    • pp.82-90
    • /
    • 2000
  • The abutment of bridge on soft foundation makes lateral movement due to the settlement of back fill and lateral flow. To measure the displacement of such a abutment, there are a lot of indirect method for measurement such as survey of leveling or inclinometer gauge around the abutment. But all of them are not sufficient to confirm the ground behavior and measure the exact lateral behavior of structure. As making the structure and pile cooperatively by measuring the movement of lateral displacement, for measuring the abutment displacement precisely by using the incliinometer. In this work, we try to suggest efficient measuring method of abutment displacement and its application.

  • PDF

유한요소법(有限要素法)에 의(依)한 Telescope Denture의 지대치(支臺齒) 및 지지조직(支持組織)의 역학적(力學的) 반응(反應)에 관(關)한 연구(硏究) (A STUDY ON THE MECHANICAL BEHAVIORS OF ABUTMENT TEETH AND SUPPORTING TISSUE OF THE TELESCOPE DENTURE BY THE FINITE ELEMENT METHOD)

  • 김문기;최부병
    • 대한치과보철학회지
    • /
    • 제22권1호
    • /
    • pp.109-122
    • /
    • 1984
  • The purpose of this study was to analyze the magnitude and mode of the stress distribution induced in the supporting alveolar bone and periodontal ligament and, to determine the displacement of abutment teeth and telescope denture base by applying chewing force to the telescope denture quantitatively and qualitatively. Two finite element models of telescope denture that were restored the missing mandibular second molar with two abutment teeth which were constructed. In two different models, parallel and tapering type telescope crowns were constructed. These finite element models of two cases used for these experiment were a two-dimensional mesiodistal section of the mandibular second bicuspid and first molar. Chewing force of 25Kg that was devided in the ratio of 45/155 (29%) in bicuspid and 55/155 (35.5%) in molars was applied to telescope denture and abutment teeth respectively. The displacement of the telescope denture base and abutment teeth and the stress distribution in the periodontal ligament and alveolar bone were analized to investigate the influence of chewing force acting on the telescope denture and abutment teeth. The results were as follows: 1. Abutment teeth displaced mesially and the magnitude of displacement of abutment teeth in vertical direction were more than that of horizontal direction in two cases. The displacement of abutment teeth on the telescope denture treated with tapering type telescope crown were less than that of the parallel type crown. 2. The displacement of the telescope denture base that were treated with parallel type telescope crown were less than that of treated with tapering type telescope crown. 3. The stress induced in the alveolar bone and periodontal ligament on abutment teeth that treated with parallel type telescope crown were more than that of treated with tapering type telescope crown and more stress induced in the alveolar bone than in the periodontal ligament. 4. In the telescope denture, the magnitude of displacement of abutment teeth and stress induced in the periodontal ligament and alveolar bone were within physiologic limit.

  • PDF

연약지반상 고성토 교대구간의 지반거동 특성 (Characteristics of Ground Movement in High Filling Abutment on Soft Ground)

  • 허열;송석철;안광국;오승탁;서상구
    • 한국지반환경공학회 논문집
    • /
    • 제9권7호
    • /
    • pp.13-23
    • /
    • 2008
  • 본 연구에서는 모래다짐말뚝으로 개량된 점성토 지반에 고성토시 발생될 수 있는 측방유동과 교대의 안정성을 파악하기 위하여 원심모형실험과 수치해석을 수행하였다. 원심모형실험과 수치해석은 교대 배면구간을 EPS로 성토한 경우(Case 1)와 토사로 성토한 경우(Case 2)에 대하여 수행하였으며, 모형실험시 교대와 성토체에 potentiometer를 설치하여 교대상부의 수직변위와 수평변위 및 성토체의 수직변위를 측정하였다. 원심모형실험결과 Case 1에서 교대의 수평변위는 1.4cm 정도로 해석결과와 거의 일치하며, 허용기준을 만족하는 것으로 나타났다. 반면, Case 2에서 교대의 수평변위는 12cm 정도로 해석결과에 비해 18% 정도 크게 평가되었으며, 허용기준을 초과하는 것으로 나타났다. 해석결과 Case 1에서 말뚝의 최대수평변위는 1.26cm로 허용 수평변위 기준(1.5cm)을 만족하는 것으로 나타난 반면, Case 2에서 말뚝의 최대 수평변위는 1.005m로 허용기준을 크게 초과하는 것으로 나타났다.

  • PDF

Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.305-312
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS. The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (106 cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces. RESULTS. There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant. CONCLUSION. The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.

복합지반상 교대변위 및 지반 측방유동에 관한 원심모델링 (Centrifuge Modeling on Lateral Flow of Soft Soils and Displacement of Bridge Abutment on the Composite Ground)

  • 허열;박성훈;윤석현;권선욱
    • 한국지반환경공학회 논문집
    • /
    • 제8권5호
    • /
    • pp.39-46
    • /
    • 2007
  • 본 연구에서는 모래다짐말뚝(SCP)로 개량된 복합 지반상의 고성토 지반 및 교대의 측방유동과 안정성을 파악하기 위하여 원심모형실험을 수행하였다. 원심모형실험은 교대배면구간을 EPS로 성토한 경우(Case 1)와 교대 배면구간을 토사로 성토한 경우(Case 2)에 대하여 수행하였으며, 모형실험시 성토체 상부와 교대구간에 Potentiometer를 설치하여 단계 성토별 성토체 수직변위 및 단계별 개량지반내 변형 양상과 교대상부에서 발생되는 수직 및 수평 변위를 측정하였다. 실험결과, 교대배면 성토부에서 수직변위는 최대 2.10m 정도(현장조건)로 성토고 대비 약 12%로 나타났다. 교대배면구간을 토사로 성토한 경우(Case 2) 교대 상부에서 측정된 수직 및 수평변위는 각각 10cm와 1.1m 정도로 허용기준을 크게 초과하였다. 반면, EPS로 뒷채움을 하는 경우(Case 1) 교대의 수직변위는 거의 발생하지 않았으며, 수평변위는 1.4cm 정도로 나타났다. 따라서, 연약지반상 도로 시공시 성토체의 안정성 확보를 위한 SCP공법 및 교대의 측방유동을 방지할 목적으로 채택된 SCP 개량 + EPS 성토공법의 효과는 매우 우수한 것으로 판단된다.

  • PDF

뒤채움 시공순서 및 말뚝 수에 따른 교대 접속부 거동평가 (Evaluation of Behaviors in Abutment Transition Zone Depending on Constrution Orders and Number of Piles)

  • 김웅진;정락교;김대상
    • 한국산학기술학회논문지
    • /
    • 제18권1호
    • /
    • pp.1-7
    • /
    • 2017
  • RAR(Reinforced Abutment for Railways)은 뒤채움을 선 시공하고, 교대를 후 시공하여 접속부의 침하와 교대 수평토압 및 변위를 저감할 수 있는 교대 구조로 교대 구체 및 저판의 사이즈와 말뚝의 설치 수를 줄인 경제적인 교대 구조이다. 본 논문에서는 말뚝 설치 수에 따른 RAR의 성능을 수치 해석을 이용하여 평가하였다. 말뚝의 설치 수를 1~4열을 적용한 RAR을 지반 변형계수를 달리한 조건에 대하여 수치 해석을 수행하고, 그 결과를 동일한 지반 조건에서 기존 교대의 수치해석결과와 비교, 분석하였다. 해석결과 말뚝 설치 수를 증가시키는 경우 접속부 침하저감 효과는 비교적 크지 않았고, 교대수평변위 및 토압 저감에 더 효과적인 것으로 나타났다. 말뚝 설치 열 수가 1~4열로 변할 때 RAR의 수평변위는 기존교대의 26~37%, 수평토압은 59~83%수준으로 말뚝 설치수가 증가할수록 기존교대(말뚝5열)에 비해 수평변위와 토압을 크게 저감할 수 있는 것으로 나타났다. 또한 RAR의 수평 토압은 보강재, 말뚝, 기초저판, 원지반 강성 등의 영향을 복합적으로 받는 것으로 평가되었다.

Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading

  • Mishra, Manish;Ozawa, Shogo;Masuda, Tatsuhiko;Yoshioka, Fumi;Tanaka, Yoshinobu
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권3호
    • /
    • pp.140-144
    • /
    • 2011
  • PURPOSE. Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading. MATERIALS AND METHODS. Two dimensional finite element models of cylinderical implant, abutments and bone made by titanium or polyoxymethylene were simulated with the aid of Marc/Mentat software. Each model represented bone, implant and titanium or polyoxymethylene abutment. Model 1: Implant with 3 mm titanium abutment, Model 2: Implant with 2 mm polyoxymethylene resilient material abutment, Model 3: Implant with 3 mm polyoxymethylene resilient material abutment and Model 4: Implant with 4 mm polyoxymethylene resilient material abutment. A vertical load of 11 N was applied with a frequency of 2 cycles/sec. The stress distribution pattern and displacement at the junction of cortical bone and implant was recorded. RESULTS. When Model 2, 3 and 4 are compared with Model 1, they showed narrowing of stress distribution pattern in the cortical bone as the height of the polyoxymethylene resilient material abutment increases. Model 2, 3 and 4 showed slightly less but similar displacement when compared to Model 1. CONCLUSION. Within the limitation of this study, we conclude that introduction of different height resilient material abutment with different heights i.e. 2 mm, 3 mm and 4 mm polyoxymethylene, does not bring about significant change in stress distribution pattern and displacement as compared to 3 mm Ti abutment. Clinically, with the application of resilient material abutment there is no significant change in stress distribution around implant-bone interface.

Integral Abutment Bridge behavior under uncertain thermal and time-dependent load

  • Kim, WooSeok;Laman, Jeffrey A.
    • Structural Engineering and Mechanics
    • /
    • 제46권1호
    • /
    • pp.53-73
    • /
    • 2013
  • Prediction of prestressed concrete girder integral abutment bridge (IAB) load effect requires understanding of the inherent uncertainties as it relates to thermal loading, time-dependent effects, bridge material properties and soil properties. In addition, complex inelastic and hysteretic behavior must be considered over an extended, 75-year bridge life. The present study establishes IAB displacement and internal force statistics based on available material property and soil property statistical models and Monte Carlo simulations. Numerical models within the simulation were developed to evaluate the 75-year bridge displacements and internal forces based on 2D numerical models that were calibrated against four field monitored IABs. The considered input uncertainties include both resistance and load variables. Material variables are: (1) concrete elastic modulus; (2) backfill stiffness; and (3) lateral pile soil stiffness. Thermal, time dependent, and soil loading variables are: (1) superstructure temperature fluctuation; (2) superstructure concrete thermal expansion coefficient; (3) superstructure temperature gradient; (4) concrete creep and shrinkage; (5) bridge construction timeline; and (6) backfill pressure on backwall and abutment. IAB displacement and internal force statistics were established for: (1) bridge axial force; (2) bridge bending moment; (3) pile lateral force; (4) pile moment; (5) pile head/abutment displacement; (6) compressive stress at the top fiber at the mid-span of the exterior span; and (7) tensile stress at the bottom fiber at the mid-span of the exterior span. These established IAB displacement and internal force statistics provide a basis for future reliability-based design criteria development.