Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading |
Mishra, Manish
(Department of Removal Prosthodontics, School of Dentistry, Aichi Gakuin University)
Ozawa, Shogo (Department of Removal Prosthodontics, School of Dentistry, Aichi Gakuin University) Masuda, Tatsuhiko (Department of Removal Prosthodontics, School of Dentistry, Aichi Gakuin University) Yoshioka, Fumi (Department of Removal Prosthodontics, School of Dentistry, Aichi Gakuin University) Tanaka, Yoshinobu (Department of Removal Prosthodontics, School of Dentistry, Aichi Gakuin University) |
1 | Holmes DC, Grigsby WR, Goel VK, Keller JC. Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: a finite element stress analysis. Int J Oral Maxillofac Implants 1992;7: 450-8. |
2 | McGlumphy EA, Campagni WV, Peterson LJ. A comparison of the stress transfer characteristics of a dental implant with a rigid or a resilient internal element. J Prosthet Dent 1989;62:586-93. DOI ScienceOn |
3 | van Rossen IP, Braak LH, de Putter C, de Groot K. Stressabsorbing elements in dental implants. J Prosthet Dent 1990;64: 198-205. DOI ScienceOn |
4 | Sato M, Kuboki T, Itasaka M, Kondo Y, Yamashita A. Stresstransfer characteristics of stress-absorbing elements in the IMZ implant system: Part 1. Stress around a freestanding single implant under static loading conditions. J Jpn Prosthodont Soc 1992;36:1102-10. DOI |
5 | Haganman CR, Holmes DC, Aquilino SA, Diaz-Arnold AM, Stanford CM. Deflection and stress distribution in three different IMZ abutment designs. J Prosthodont 1997;6:110-21. DOI ScienceOn |
6 | Morton D, Stanford CM, Aquilino SA. Evaluation of resilient abutment components on measured strain using dynamic loading conditions. J Prosthet Dent 1998;80:46-51. DOI ScienceOn |
7 | Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent 1983;49:843-8. DOI ScienceOn |
8 | Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent 2001;85:585-98. DOI ScienceOn |
9 | Oh TJ, Yoon J, Misch CE, Wang HL. The causes of early implant bone loss: myth or science? J Periodontol 2002;73:322-33. DOI ScienceOn |
10 | Kirsch A, Mentag PJ. The IMZ endosseous two phase implant system: a complete oral rehabilitation treatment concept. J Oral Implantol 1986;12:576-89. |
11 | Babbush CA, Kirsch A, Mentag PJ, Hill B. Intramobile cylinder (IMZ) two-stage osteointegrated implant system with the intramobile intramobile element (IME): part I. Its ratinale and procedure for use. Int J Oral Maxillofac Implants 1987;2:203-16. |
12 | Achour T, Merdji A, Bachir BB, Serier B, Djebbar N. Stress distribution in dental implant with elastomeric stress barrier. Mater Design 2011;32:282-90. DOI |