• 제목/요약/키워드: Absorption system

검색결과 2,013건 처리시간 0.033초

병렬 다공판 시스템의 흡음성능에 관한 연구 (A Study on the Sound Absorbing Performance of Parallel Perforated Plate Systems)

  • 허성춘;임정빈;노승남;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.902-907
    • /
    • 2002
  • An equivalent electroacoustic circuit approach of estimating the sound absorption coefficient for parallel perforated plate system is proposed. The proposed approach is validated by comparing the calculated absorption coefficients of a parallel single layer perforated plate system with the values measured by the two-microphone impedance tube method for various porosity and the number of perforated plate. The sound absorbing performances of parallel and series perforated plate systems are compared and discussed from a standpoint of frequency bandwidth with sound absorption. The proposed approach is further extended to the parallel double layer perforated plate system.

  • PDF

급수관로계에 설치된 수격흡수기의 수격흡수효과에 관한 실험적 연구 (Experimental Study on the Water Hammer Absorption Effects of Water Hammer Arrester in the Water Supply Piping System)

  • 최중근;이석종;이명호;성재용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.396-402
    • /
    • 2006
  • In this study, dynamic characteristics of water hammer pressure in water supply piping system with water hammer arrester has been investigated experimentally to characterize the transient pressure of water hammer in high rise building. Experiments were conducted to verify the absorption effects by water hammer arresters with 3 different gas volumes of water hammer pressure generated by sudden valve closure. As the results, it has been found that zoning and sizing of pipe diameter for suitable flow velocity and water hammer arresters with effective pressure absorption capacity have to be installed to protect water hammer problems in building water supply piping system.

태양열을 이용한 흡수식 냉방시스템의 시뮬레이션과 운전조건의 검토 (Simulation of Solar/Absorption Cooling Hybrid System and Examination of Its Operating Condition)

  • 허재영;이상용
    • 대한설비공학회지:설비저널
    • /
    • 제14권1호
    • /
    • pp.1-11
    • /
    • 1985
  • Solar/absorption cooling system was analyzed and its operating condition was examined. For the system, the optimum size of absorption refrigerator and collector area should be determined. As the temperature of water supplied to the generator increases, the collector efficiency decreases whereas the coefficient of performance of absorption refrigerator increases up to a certain point, and vice versa for decreasing of the temperature of water supplied to the generator . Thus if the reeling load is given, the appropriate operating condition can be determined between the two opposing trends by simulation program. As an example of the simulation, the case of Jejudo province was studied. Under the conditions (such as weather data and prices of components, etc.) given en the sample calculation, the result shows that the optimum temperature of water supplied to the generator turned out to be $80.3^{\circ}C$, and still shows a large economical disadvantage in present stage compared to the case of conventional vapor compression cooling/heating combined heat pump system.

  • PDF

다이오드 레이저를 이용한 광흡수 농도 계측 기법 (I) (Species Concentration Measurement Using Diode Laser Absorption Spectroscopy (I))

  • 안재현;김용모;김세원
    • 한국연소학회지
    • /
    • 제9권3호
    • /
    • pp.27-35
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, resonable cost, robustness, and ease of use. In addition, diode lasers are fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develope a new gas sensing system and to verify feasibility of this system. Wavelength and power characteristics as a function of injection current and temperature are experimentally found out. Direct absorption spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

공냉식 흡수식 냉동기의 특성 해석 (Characteristic analysis of air-cooled absorption refrigeration machine)

  • 권오경;문춘근;양영명;유선일;윤정인
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 1998년도 추계학술발표회 논문집
    • /
    • pp.249-254
    • /
    • 1998
  • This paper describes the study of developing air-cooled absorption system which uses a new working solution instead of LiBr solution to improve the performance of system. The absorption chiller-heater considered was an air-cooled, double-effect, $H_2O/LiBr+HO(CH_2)_3$ system of parallel flow type. In this study, we found out the characteristic of new working solution through the cycle simulation and compared the result that of LiBr solution to evaluate. The new working fluid has a wider working range with $8\%$ higher crystallization limit at the saturated refrigerant pressure of 0.8kPa. The optimum designs and operating conditions of air-cooled absorption system were suggested based on this cycle simulation analysis. It was demonstrated that new working fluid substantially improves the performance of the absorption refrigeration machine and is expected to increase the COP by as much as $5\%$.

  • PDF

지역냉방 적용을 위한 LNG냉열 장거리 수송용 제 2종 흡수식 시스템 (Type 2 Absorption Cycle to Transport Energy in the Long Distance for District Cooling Application)

  • 조영경;김진경;오민규;강용태
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.250-255
    • /
    • 2005
  • The objective of this paper is to develop a new energy transport system for district cooling application by using type 2 absorption cycle. Cold energy from the LNG storage system is utilized as the cooling source of the condenser and the rectifier. The pressures of the system, UAs of the evaporator and the desorber, and the inlet temperatures of the refrigerant to each component are considered as the key parameters. The results show that UA of the evaporator is more dominant parameter on COP than that of the desorber and the optimum system pressure for the demand side is estimated as 525 kPa. For the present system, it is recommended that the refrigerant inlet temperature of the evaporator be lower than $4.3^{\circ}C$ for long-distance transportation. It is concluded that the cold energy from the LNG storage system can be effectively applied to the long-distance transportation system for district cooling application with the type 2 absorption cycle. The optimum operation conditions are also predicted from the parametric analysis.

유기색소의 흡수대 형태와 분자구조와의 상관성 (Relationship between the Molecular Structure and the Absorption Band Shape of Organic Dye)

  • 전근;권선영;김성훈
    • 한국염색가공학회지
    • /
    • 제27권4호
    • /
    • pp.270-274
    • /
    • 2015
  • Molecules always show broad absorption band envelopes, and this results from the vibrational properties of bonds. The width of an absorption band can have an important influence on the color of a dye. A narrow band imparts a bright, spectrally pure color to the dye, whereas a broad band can give the same hue, but with a much duller appearance. Typically, half-band widths of cyanine dyes are about 25nm compared to value of over 50nm for typical merocyanine dyes. Thus, cyanine dyes are exceptionally bright. The factors influencing the width of an absorption band can be understood with reference to the Morse curves. The width of the absorption band depends on how closely the bond order of the molecules in the first excited state resembles that in the ground state. We have quantitatively evaluated the "molecular structure-absorption band shape" relationship of dye molecules by means of Pariser-Parr-Pople Molecular Orbital Method(PPP-MO).

흡수압축 하이브리드 히트펌프 사이클의 성능특성 (Performance Characteristic of the Compression-Absorption Hybrid Heat Pump Cycles)

  • 윤정인;권오경;양영명
    • 한국가스학회지
    • /
    • 제3권1호
    • /
    • pp.14-20
    • /
    • 1999
  • [ $H_2O/LiBr$ ]계 흡수식 사이클에 압축기를 조합한 흡수압축사이클을 도입하여 증기를 단열압축시켜 그 증기의 응축열을 재생열로 이용하는 사이클에 대해서 시뮬레이션을 통하여 횹수압축사이클의 특성을 밝힌 연구이다. 기존의 흡수사이클에 압축기를 도입함에 따라 고효율 사이클을 실현할 수 있음을 제시하였으며, 흡수$\cdot$압축사이클의 구체적인 가능성을 제시하였다. 재생기에서 발생한 냉매증기를 단열압축시킨 TYPE 2는 단열압축 증기의 응축열만으로는 재생이 어려우므로 외부로부터 별도의 열량을 투입해야 하며 투입하는 외부열량에 폐열이나 2차 에너지를 이용할 수 있다면 높은 COP를 얻을 수 있어 실현가능성이 높다.

  • PDF

보육교사 직무만족이 조직몰입에 미치는 영향요인 분석 (Analysis of The Main Causes of The Effect of The Job Satisfaction to The System Absorption of The Childcare Teachers)

  • 김윤재;남궁선;강영숙
    • 벤처창업연구
    • /
    • 제9권4호
    • /
    • pp.135-144
    • /
    • 2014
  • 본 연구는 어린이집에서의 보육교사 역할의 중요성에 대한 인식 확산 및 시설이 확대되는 시점에서 어린이집에서 근무하는 보육교사들을 대상으로 조직몰입에 대해 스스로 어떻게 평가하고 있는지를 살펴보고, 이에 영향을 미치는 요인이 무엇인지 살펴보았다. 서울지역 어린이집에서 근무하는 보육교사를 대상으로 직무만족 자기인식 요인과 원장의 리더십 자기인식 요인, 인구통계학적 특성, 직장관련 특성 요인들이 조직몰입(정서적 몰입, 규범적 몰입, 지속적 몰입)에 영향을 미치는 요인들을 분석하였다. 분석 결과 직무만족, 개별적 고려, 지적 자극, 동기부여, 연령, 학력, 시설유형, 시설규모, 직급 등이 조직몰입에 대한 자기평가에 통계적으로 유의미한 영향을 미치는 것으로 나타났다. 즉, 보육교사는 원장의 지적 자극을 올리는 리더십, 동기부여를 제공하는 원장의 리더십, 교사 개인별로 배려를 해주는 원장의 리더십을 접할수록, 그리고 보육교사 개인이 인지하는 직무만족 자기평가가 높을수록 조직몰입에 반응정도가 긍정적인 방향으로 영향을 미칠 것이다. 이를 바탕으로 어린이집 원장은 보다 적극적 및 교사 배려적 운영을 위한 리더십을 펼치는 한편, 보육교사들의 직무만족 향상을 위한 다양한 경영서비스 제공 및 개발이 요구된다고 할 것이다.

  • PDF

흡수압축 하이브리드 사이클의 성능특성 (Performance Characteristic of the compression-absorption hybrid cycles)

  • 김재만;권오경;문춘근;설원실;윤정인
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 1998년도 추계학술발표회 논문집
    • /
    • pp.255-260
    • /
    • 1998
  • This study describes the results of Coefficient Of Performance(COP) analysis by cycle simulation for two types of absorption-compression hybride cycle using the water/Lithium Bromide solution pair, These types are basic hybride systems introducing a mechanical compression process into the refrigerant vapor phase of the single effect absorption cycle. In absorption-compression hybrid cycles, coefficient of performance is improved compared with absorption cycle. Hybride cycle Type ll is considered as a key technology to support energy utilization system, given its capability of utilizing waste heat to drive system with a high level of efficiency.

  • PDF