• 제목/요약/키워드: Absorption spectrometry

검색결과 220건 처리시간 0.026초

인공타액에서 수종 아말감의 부식시 용해성분 및 표면 부식 생성물에 관한 실험적 연구 (EXPERIMENTAL STUDY ON THE DISSOLUTION COMPONENTS AND CORROSION PRODUCTS OF SEVERAL AMALGAMS IN ARTIFICIAL SALIVA)

  • 조승주;이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.1-26
    • /
    • 1994
  • The purpose of this study was to investigate the dissolution components during corrosion of amalgams and to identify surface corrosion products in the modified Fusayama artificial saliva. Four type of amalgam alloys were used: low copper lathe cut amalgam alloy (Cavex 68), low copper spherical amalgam alloy (Caulk Spherical Alloy), high copper admixed amalgam alloy (Dispersalloy) and high copper single composition amalgam alloy (Tytin). Each amalgam alloy and Hg were triturated according to the manufacturer's direction by means of mechanical amalgamator (Capmaster, S.S.White), and then the triturated mass was inserted into the cylindrical metal mold which was 10mm in diameter and 2.0mm in height and condensed with compression of 150kg/$cm^2$ using oil pressor. The specimens were removed from the mold and stored at room temperature for 7 days and cleansed with distiled water for 30 minutes in an ultrasonic cleaner. The specimens were immersed in the modified Fusayama artificial saliva for the periods of 1 month, 3 months and 6 months. The amounts of Hg, Cu, Sn and Zn dissolved from each amalgam specimen immersed in the artificial saliva for the periods of 1 month, 3 months and 6 months were measured using Inductivity Coupled Plasma Atomic Emission Spectrometry (ICPQ-1000, Shimadzu, Japan) and amount of Ag dissolved from amalgam specimen was measured using Atomic Absorption Spectrophotometry (Atomic Absorption/Flame emission spectrophotometer M-670, Shimadzu, Japan). A surface corrosion products of specimens were analysed using Electron Spectroscopy Chemical Analyser (ESCA PHI-558, PERKIN ELMER, U.S.A.). The secondary image and back scattered image of corroded surface of specimens was observed under the SEM, and the corroded surface of specimens was analysed with the EDX. The following results were obtained. 1. The dissolution amount of Cu was the most in high copper admixed amalgam(Dispersalloy) and the least in high copper single composition amalgam(Tytin). 2. Sn and Zn were dissolved during all the experiment periods, and dissolution amounts were decreased as the time elapsed. 3. Initial surface corrosion products were ZnO and SnO. 4. Corrosion of ${\gamma}$ and ${\gamma}_2$ phase in low copper amalgams was observed and Ag-Cu eutectic alloy phase was corroded in low copper spherical amalgam(Caulk Sperical Alloy). 5. Corrosion of ${\gamma}$ and $\eta$' phase in high copper amalgams was observed and Ag-Cu eutectic alloy phase was corroded in high copper admixed amalgam(Dispersalloy). 6. Sn-Cl was produced in the subsurface of low copper amalgams and high copper admixed amalgam.

  • PDF

흑연로 원자흡수분광법에 의한 혈액중 카드뮴 정량분석 (A Comparative Analysis of Whole Blood Cadmium by Atomic Absorption Spectrophotometry with a Graphite Furnace)

  • 박종안;오혜정;이종화
    • 한국산업보건학회지
    • /
    • 제6권2호
    • /
    • pp.301-312
    • /
    • 1996
  • This study was performed to search a optimal analyzing method of cadmium in whole-blood. Cadmium was determined by graphite furnace atomic absorption spectrometry(GFAAS). We investigated the effect of ashing temperature on the absorbance of cadmium in a simple dilution(ten-fold) method with triton X-100 and matrix modifier methods treated with $NH_4H_2PO_4$(1 and 3%) and $Pd(NO_3)_2$(0.00l and 0.005%) as matrix modifier. We also compared the reported reference values of standard blood with values resulted from optimal analyzing conditions of this study. In case of a simple dilution method, when ashing temperature was set at $450^{\circ}C$, the absorbance of sample and background were $0.334{\pm}0.012$ and $1.382{\pm}0.245$, respectively. Background level was higher than the value(0.8) that can be corrected by $D_2$ background correction method. As ashing temperature was rised to $500^{\circ}C$, the absorbance of sample and background were $0.178{\pm}0.008$ and $0.711{\pm}0.223$ respectively. The higher ashing temperature($450^{\circ}C-650^{\circ}C$) was, the lower the absorbance of sample was. In case of a matrix modifier method with $NH_4H_2PO_4$(1 and 3%), when ashing temperature was rised from $500^{\circ}C$ to $650^{\circ}C$, the absorbance of sample slightly changed. The absorbances of sample at $600^{\circ}C$ were $0.230{\pm}0.017$ and $0.137{\pm}0.012$, respectively. These values were larger than that of simple dilution method. But the absorbance of background was higher than the level that can be corrected by $D_2$ method. In case of a matrix modifier method with $Pd(NO_3)_2$(0.001 and 0.005%), the absorbance of sample and background were higher than those of other methods and were stable and reproducible. When ashing temperature was over $550^{\circ}C$, the absorbance of sample was significantly decreased. In case of 0.005% $Pd(NO_3)_2$ carbon residue remained in graphite tube affected the absorbance of sample and background. From these results, We propose that in case of a simple dilution(ten-fold) method with triton X-100 ashing temperature must be maintained below $400^{\circ}C$. In order to diminish the absorbance of background, the alternative method is attenuation of injection volume or multiplication of dilution ratio. We recommend $Pd(NO_3)_2$ than $NH_4H_2PO_4$ as a matrix modifier. In case of a matrix modifier method with $Pd(NO_3)_2$ ashing temperature might be maintained below $550^{\circ}C$.

  • PDF

표층해수 내 용존 메탄 탄소동위원소 실시간 측정을 위한 광학기기의 개발 및 활용 전망 (Recent Technological Advances in Optical Instruments and Future Applications for in Situ Stable Isotope Analysis of CH4 in the Surface Ocean and Marine Atmosphere)

  • 박미경;박선영
    • 한국해양학회지:바다
    • /
    • 제23권1호
    • /
    • pp.32-48
    • /
    • 2018
  • 대기 중 메탄의 해양 흡수와 방출 메커니즘은 생지화학 순환이 갖는 복잡성과 해양-대기 경계면에서 지역 규모 혹은 기작 단위에서의 관측 연구 부족으로 잘 알려져 있지 못하다. 그러나 다양한 시 공간적 규모에서 탄소 수지와 순환을 조절하는 해양 메커니즘에 대한 완전한 이해 없이는, 해양의 탄소 변동과 전 지구적 지역적 기후 변화에 미치는 영향을 예측하기란 불가능하다. 표층해양 및 해양대기에서 용존 메탄의 탄소동위원소 조성에 대한 정밀한 연속 관측은 해양-대기 경계면에서의 유 출입 및 생산 소모 과정에 대한 추가적인 정보를 제공한다. 본 연구는 최근 급격히 발전한 광학기반 동위원소 분석 기기들을 개괄적으로 소개하고, 표층 양 내 용존 메탄과 해양대기 메탄의 탄소동위원소 실시간 연속 측정으로의 적용을 위해, 현재 이들 기기들의 기술 및 활용 현황을 논의한다. 이어 레이저 광원의 흡수분광기 중 하나로, 사용이 최근 급증하고 있는 광공동 링다운분광기(CRDS, Cavity Ring Down Spectroscopy)기반 동위원소 분석기기를 예시로 하여 연속 관측 시스템의 운용, 최적화 조건, 보정법을 제안하며, 기체 시료로부터 실시간 관측된 메탄 농도 및 메탄 탄소동위원소의 관측 예를 소개하고자 한다. 이러한 가능성 검토를 통해 향후 해양 환경에서의 실시간 메탄 탄소동위원소 분석 연구의 방향을 제안하고자 한다.

거주지와 산업단지간의 거리와 혈 중 납 농도 및 요 중 카드뮴 농도의 상관관계에 관한 연구 (A Study of the Relationships Between Proximity to an Industrial Complex and Blood Lead Levels and Urinary Cadmium Levels)

  • 허진아;김효미;이종태
    • 한국환경보건학회지
    • /
    • 제38권2호
    • /
    • pp.95-104
    • /
    • 2012
  • Objectives: The goal of this study was to investigate the relationships between proximity to an industrial complex and blood lead levels and urinary cadmium levels. Methods: We conducted a questionnaire survey and analyzed blood lead and urinary cadmium levels using Atomic Absorption Spectrometry (AAs). Data was analyzed using logistic regression analysis. All statistical analyses were conducted with SAS software version 9.2. The distance between the residence and an industrial complex was calculated through a Geographical Information System (GIS). Results: A total of 967 residents living near a large petrochemical complex in Ulsan participated. The geometric mean levels of blood lead and urinary cadmium were $1.70{\mu}g/dl$ (male: $1.77{\mu}g/dl$, female: $1.67{\mu}g/dl$), and $0.72{\mu}g/g$ creatinine (male: $0.49{\mu}g/g$ cr. female: $0.89{\mu}g/g$ cr.), respectively. Blood lead and urinary cadmium levels both increased with age and were higher among smokers compared to never smokers. Both significantly showed a decreasing trend with rising income. Results from multiple logistic regression analysis showed that urinary cadmium levels for subjects aged less than 20 years old were negatively associated with distance from the industrial area to the residence. The results, however, indicated that the blood lead levels were positively associated with the distance. Conclusions: The results of this study support that proximity to an industrial complex is related to urinary cadmium values for children. A positive finding with blood lead can be explained by the ambiguity of lead exposure sources in the general environment.

The impact of municipal waste disposal of heavy metals on environmental pollution: A case study for Tonekabon, Iran

  • Azizpour, Aziz;Azarafza, Mohammad;Akgun, Haluk
    • Advances in environmental research
    • /
    • 제9권3호
    • /
    • pp.175-189
    • /
    • 2020
  • Municipal solid waste disposal is considered as one of the most important risks for environmental contamination which necessitates the development of strategies to reduce destructive consequences on the ecosystem as related especially to heavy metal accumulation. This study investigates heavy metal (i.e., As, Cd, Co, Cr, Cu, Mn, Ni, Pb, Zn) accumulation in the Tonekabon region, NW of Iran that is related to city waste disposal and evaluates the environmental impact in the Caspian Sea coastal region. For this purpose, after performing field studies and collecting 50 soil specimens from 5 sites of the study area, geochemical tests (i.e., inductively coupled plasma mass spectrometry, atomic absorption spectroscopy and x-ray fluorescence) were conducted on the soil specimens collected from the 5 sites (named as Sites A1, A2, A3, A4 and A5) and the results were used to estimate the pollution indices (i.e., geo-accumulation index, normalized enrichment factor, contamination factor, and pollution load index). The obtained indices were utilized to assess the eco-toxicological risk level in the landfill site which indicated that the city has been severely contaminated by Cu, Mn, Ni, Pb and Zn. These levels have been developed along the stream towards the nearshore areas indicating uptake of soil degradation. The heavy metal contamination was classified to range from unpolluted to highly polluted, which indicated serious heavy metal pollution in the study area as related to municipal solid waste disposal in Tonekabon.

The Association of Maternal Food Intake and Blood Lead Levels in Pregnant and Their Newborns

  • Lee, Ah-Young;Kim, Hye-Sook;Kim, Ki-Nam;Ha, Eun-Hee;Park, Hye-Sook;Ha, Mi-Na;Kim, Yang-Ho;Hong, Yun-Chul;Chang, Nam-Soo
    • Molecular & Cellular Toxicology
    • /
    • 제4권1호
    • /
    • pp.61-65
    • /
    • 2008
  • Although dietary intake of pregnant is supposed to have beneficial effects on development of infants, it may be harmful for fetal growth and development since specific food is a common source of toxicants including heavy metal. The purpose of this study was to investigate the association of maternal food intake and mid-pregnancy and their newborns blood lead levels. Pregnant women of 18-20 weeks of gestation were recruited from prenatal clinic in Seoul, Cheonan and Ulsan. In 422 pregnant women, dietary intake during pregnancy was assessed by a 24-hour recall method. Blood sample from pregnant (18-20 wks) and their cord blood at delivery were collected. Blood leas levels were analyzed by atomic-absorption spectrometry methods. Pregnant blood lead levels whose meat and meat products intake were in the highest quartile was significantly higher compared to the lowest quartile. Maternal meat and meat products intake was positively correlated maternal blood lead level (r=0.120, P=0.014). After adjusting for age, maternal blood lead level was positively correlated with their newborn blood lead level (r=0.303, P=0.030). As maternal food intake effects on blood lead levels of pregnant, careful regulation of food intake during pregnancy is perceives to be important in order to bring about desirable pregnancy outcomes.

K/Na Ratio를 이용한 토종꿀과 양봉꿀의 품질 특성 비교 (Comparison of Quality Attributes of Korean Native-Bee Honey and Foreign-Bee Honey by K/Na Ratio)

  • 김은선;이종욱
    • 한국식품영양과학회지
    • /
    • 제25권4호
    • /
    • pp.672-679
    • /
    • 1996
  • 토종꿀파 양봉꿀의 이화학적 특성을 비교, 분석하였고 벌꿀에 함유되 어 있는 무기성분 중 K/Na ratio를 이용하여 토종꿀의 판별가능성을 고찰하였다. 벌꿀의 이화학적 특성을 살펴 본 결과, 토종꿀과 양봉꿀의 일반성분 중에서 가장 차이가 두드러진 항목이 회분과 조 단백질이었는데 토종꿀의 함량은 평균 0.31% 및 0.28%, 양봉꿀의 평균 함량은 0.11%및 0.13%로서 토종꿀이 휠씬 높게 나타났다. 벌꿀 중의 proline과 diastase activity는 토종꿀이 평균 13.6mg%, 31.7unit, 양봉꿀은 평균 16.4mg%, 17.0unit로서 proline 함랑은 양봉꿀이 높았으며, diastase activity는 토종꿀이 더 높았다. 무기성분은 토종꿀이 양봉꿀에 비해 월등히 많이 함유하고 있는 성분이 었는데, 주요 무기성 분은 Ca, Mg, Na, K, Cl 등으로 토종꿀에서는 K가 가장 높은 함량을 보인 반면 양봉꿀에서는 Cl이 가장 높은 함량을 보였다. 본 실험에서 분석하였던 무기성분 중 K와 Na의 조성비를 이용하였더니 토종꿀과 양봉꿀의 특성이 분명하게 구분되었다. 토종꿀의 K/Na ratio는 실험 에 사용하였던 6점 모두 10 이상으로 나타난 반면 양봉꿀은 3점 모두 1.5 이하로 나타나 토종꿀을 판별할 수 있는 하나의 지표로서의 가능성이 있는 것으로 판단되었다.

  • PDF

준 실시간 측정시스템을 이용한 미세입자 원소성분 배출특성 조사 (Emission Characteristics of Elemental Constituents in Fine Particulate Matter Using a Semi-continuous Measurement System)

  • 박승식
    • 한국대기환경학회지
    • /
    • 제26권2호
    • /
    • pp.190-201
    • /
    • 2010
  • Fine particulate matter < $1.8{\mu}m$ was collected as a slurry using the Semicontinuous Elements in Aerosol Sampler with time resolution of 30-min between May 23 and 27, 2002 at the Sydney Supersite, Florida, USA. Concentrations of 11 elements, i.e., Al, As, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Se, and Zn, in the collected slurry samples were determined off-line by simultaneous multi-element graphite furnace atomic absorption spectrometry. Temporal profiles of $SO_2$ and elemental concentrations combined with meteorological parameters such as wind direction and wind speed indicate that some transient events in their concentrations are highly correlated with the periods when the plume from an animal feed supplement processing facility influenced the Sydney sampling site. The peaking concentrations of the elemental species during the transient events varied clearly as the plume intensity varied, but the relative concentrations for As, Cr, Pb, and Zn with respect to Cd showed almost consistent values. During the transient events, metal concentrations increased by factors of >10~100 due to the influence of consistent plumes from an individual stationary source. Also the multi-variate air dispersion receptor model, which was previously developed by Park et al. (2005), was applied to ambient $SO_2$ and 8 elements (Al, As, Cd, Cr, Cu, Fe, Pb, and Zn) measurements between 20:00 May 23 and 09:30 May 24 when winds blew from between 70 and $85^{\circ}$, in which animal feed processing plant is situated, to determine emission and ambient source contributions rates of $SO_2$ and elements from one animal feed processing plant. Agreement between observed and predicted $SO_2$ concentrations was excellent (R of 0.99; and their ratio, $1.09{\pm}0.35$) when one emission source was used in the model. Average ratios of observed and predicted concentrations for As, Cd, Cr, Pb, and Zn varied from $0.83{\pm}0.26$ for Pb to $1.12{\pm}0.53$ for Cd.

Bioequivalence of Mepiril Tablet to Amaryl Tablet (Glimepiride 2 mg) by Liquid Chromatography/Electrospray Tandem Mass Spectrometry

  • Lee, Heon-Woo;Cho, Sung-Hee;Park, Wan-Su;Im, Ho-Taek;Rew, Jae-Hwan;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권4호
    • /
    • pp.287-293
    • /
    • 2005
  • The purpose of the present study was to evaluate the bioequivalence of two glimepiride tablets, Amaryl tablet (Handok & Aventis Korea, reference drug) and Mepiril tablet (Myungmoon Pharm. Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (glibenclamide) to human plasma, plasma samples were extracted using 1mL of methyl tertiary butyl ether. Compounds extracted were analyzed by reverse-phase HPLC with multiple reaction monitoring (MRM) mode analyte detection. This method for determination glimepiride proved accurate and reproducible, with a limit of quantitation of 2 ng/mL in human plasma. Twenty-four healthy male Korean volunteers received each medicine at the glimepiride dose of 2 mg in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of glimepiride were monitored by a LC-MS/MS for over a period of 12 hr after the administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Amaryl/Mepiril were log 0.9583-log 1.1357 and log 1.0570-log 1.2376, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25. Taken together, our study demonstrated the bioequivalence of Amaryl and Mepiril with respect to the rate and extent of absorption.

Properties of a New Adhesive Composed of Gambir-Sucrose

  • SUCIPTO, Tito;WIDYORINI, Ragil;PRAYITNO, Tibertius Agus;LUKMANDARU, Ganis
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권3호
    • /
    • pp.303-314
    • /
    • 2020
  • Gambir is a non-wood forest product with a potential of being used as wood adhesive, due to about 33% catechin in it. Meanwhile, catechins and sucrose have not been studied as adhesives. Therefore, basic characteristics of gambir-sucrose adhesives were investigated. In this research, adhesives were prepared by dissolving gambir and sucrose in distilled water, at different blending ratios of the gambir/sucrose such as 100/0, 75/25, 50/50, and 25/75 wt%. Furthermore, gas chromatography-mass spectrometry (GC-MS) was employed to determine the gambir chemical compositions, and Fourier transform-infrared (FTIR) spectroscopy was carried out to identify chemical bonds. Particleboards with a target density of 0.8 g/㎤ were then manufactured by hot-pressing for 10 min at 200℃. The internal bond (IB) strength of particleboard was subsequently measured. Based on the GC-MS analysis, 31.11% of catechin was identified. In addition, the viscosity, density, solid content, and gelation time of the adhesives, and insoluble matter content (IMC) in boiling water were 7.30~33.24 mPa.s, 1.2~1.3 g/㎤, 25.56~28.44%, 73~420 min, and 29.75~62.10%, respectively. Adding sucrose to the adhesive was observed to raise the IMC from 49.05 to 62.10%, at 180℃ and 200℃. FT-IR analysis showed that the gambir absorption peaks occurred at approximately 1620 cm-1, assigned to the C=O stretching of 5-hydroxymethylfurfural, which tended to increase with the addition of sucrose. The reaction between gambir and sucrose was observed in the form of the dimethylene ether bridge. The 25/75 wt% gambir-sucrose adhesives and 200℃ hot-pressed temperature resulted in the highest IB strength (0.89 MPa), and met the requirement of JIS A5908-2003 type 18. Consequently, the gambir-sucrose adhesive could be used as a particleboard adhesive.