• 제목/요약/키워드: Absorption Cooling System

검색결과 152건 처리시간 0.031초

지열원 열펌프 시스템의 에너지 생산량 모니터링 신뢰도 향상 방안 연구 (A Study on the Monitoring Methods for Energy Production in Ground Source Heat Pump System)

  • 강신형;이광호;도성록;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권2호
    • /
    • pp.10-16
    • /
    • 2019
  • In this study, the present regulation of heat metering for the ground source heat pump was investigated. The ground source heat pump has been adopting the heat metering system used in the district heating system for estimating the heating and cooling energy production amount. The accuracy of the present heat metering systems for a water to water ground source heat pump is low, because the system for district heating has a relatively high temperature range comparing with the ground source heat pump operating conditions. Even though the heat amount for the building side should be measured, the heat absorption and extraction amount from or to the ground was measured for the water to air ground source heat pump due to the difficulty of estimating the air side heating and cooling capacity in the present regulation. It is highly recommended to validate the heat metering system to have reliability for the ground source heat pump and develop the system to be applicable water to air ground source heat pump.

공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • 설비공학논문집
    • /
    • 제12권12호
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 -)

  • 정광섭;김민수;김용찬;박경근;박병윤;조금남
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

대형병원에서 마이크로터빈 이용한 열병합시스템 에너지성능 및 경제성 분석 (The Energy Performance & Economy Efficiency Evaluation of Microturbine Installed in Hospital buildings)

  • 김병수;길영욱;홍원표
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.176-183
    • /
    • 2009
  • 대형병원의 에너지 소비패턴을 분석한 후 마이크로가스터빈을 적용할 경우 기존 시스템 대비 냉난방에너지 절감량 및 전기에너지 절감량과 경제성분석을 통해 대형병원의 에너지 소비량을 절감하기 위한 에너지성능평가 모의연구를 수행하였다. 0.5[MW]급 마이크로 가스터빈을 설치한 후 에너지 성능분석을 한 결과 터빈에서의 발전효율은 30[%]이며, 전기는 건물에서 사용되는 조명에너지 뿐만 아니라 전체 전기에너지의 40[%]을 절감할 수 있는 것으로 분석되었다. 또한 터빈에서 발전되는 전기량과 배열을 냉난방에너지원으로 이용할 경우 전체 시스템효율은 70[%]로 상승할 뿐만 아니라 난방에너지의 56[%], 냉방에너지의 67[%]를 절감할 수 있는 것으로 분석되었으며 현가등가법에 의한 시스템 투자회수 기간이 약 9년으로 분석되었다.

리튬이온전지 양극제조 공정에서 사용된 NMP를 회수하기 위한 하이브리드형 NMP 회수시스템 개발에 관한 연구 (Study on the Development of Hybrid NMP Recovery System for Recovering the Used NMP in Lithium Ion Battery Cathode Manufacturing Process)

  • 황순호;남승백;김동권;김양준;강성은
    • 대한기계학회논문집B
    • /
    • 제40권5호
    • /
    • pp.289-296
    • /
    • 2016
  • 리튬이온전지 양극활물질 제조공정의 용제로 사용되는 NMP(N-Methyl-2-Pyrrolidinone)는 전량수입에 의존하고 있으며 BASF와 ISP의 독과점에 따라 높은 가격을 유지하고 있다. 이로 인해 대부분의 리튬이온전지 제조업체들은 건조과정에서 배기되는 공기 중에서 NMP를 회수한 후 재사용하는 방식을 이용하고 있다. 국내에서는 주로 NMP의 친수성을 이용해 흡수탑에서 회수하는 흡수법을 사용한다. 이 방식으로 회수된 NMP의 순도는 80% 수준이며, 처리된 가스의 수분 함유량이 높아 100% 배기할 수밖에 없는 문제점이 있다. 본 연구에서는 냉각응축법과 농축법을 복합 구성하여 NMP 회수율이 99.6%, 회수된 NMP 순도가 96.1%인 하이브리드형 NMP 회수시스템을 개발하였다.

축냉식냉방 및 가스흡수식 냉방시스템의 회피비용 분석 (Avoided Cost Analysis on The Thermal Storage Cooling and Gas Absorption Cooling System)

  • 원종률;황성욱;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.267-268
    • /
    • 2008
  • 부분축열을 기준으로 주로 300RT급 이상에서 주로 보급되고 있으며, 하계 전력수요를 심야로 이전시켜 전력사용의 효율성을 높일 수 있으며 동시에 하계발전설비를 회피할 수 있는 측냉식냉방에 대한 회피비용을 분석하고자 한다. 가격, 비용, 요금 등의 자료를 조사하여 이를 토대로 캘리포니아테스트(RIM, P, UC, TRC)를 분석하여 그 결과를 통해 적정 지원금여부를 판단하고자 한다. 또한 이에 대한 비교대상으로 중대형급에서 같이 보급되고 있는 가스 흡수식 냉방시스템과 비교 분석하고자 한다.

  • PDF

온도 변색 도료의 지붕 적용 및 냉방효과 분석 (Analysis on the Cooling Effect of Applying Temperature Discoloration Paint to a Roof Surface)

  • 백상훈
    • 토지주택연구
    • /
    • 제13권4호
    • /
    • pp.115-123
    • /
    • 2022
  • 본 연구는 지붕 표면에 온도 변색 도료(Thermochromic paint) 적용에 따른 지붕 표면 온도 저감 및 실내 냉방 효과를 분석하는 것에 목적이 있다. 본 도료는 특정 온도에서 색상이 변화되는 특징을 갖는다. 만약 본 도료를 적용함으로서 지붕 표면이 여름철에는 흰색으로, 겨울철에는 검정색으로 계절에 따라 변화될 수 있다면, 여름철에는 일사를 반사하여 실내 냉방 효과를 발휘할 수 있고, 겨울철에는 일사를 흡수하여 난방 효과를 가져올 수 있다. 이 중, 본 논문에서는 본 도료에 의해 여름철에 지붕의 표면 온도와 실내 온도가 어느 정도 감소되는지에 대해 실증 실험 및 기존 도료와의 비교를 통해 그 성능을 확인하였다. 그 결과, 온도 변색 도료가 적용된 지붕의 표면온도는 기존 도료의 경우보다 대략 5~10℃ 정도 낮게 나타났으며, 이로 인해, 실내 기온 또한 기존보다 대략 3℃ 이상 낮게 분석되었다. 따라서 온도 변색 도료는 여름철 높은 표면 온도를 유지하는 지붕에 적용 될 시, 표면 온도를 크게 감소시켜 실내 냉방효과를 발휘할 수 있는 것으로 확인되었다.

화학식 냉동기의 성능 및 반응기 거동에 관한 연구 (A Study on Performance and Reactor Behavior of Chemical Refrigerator)

  • Park, Seung-Hoon;Lee, Jong-Ho
    • 에너지공학
    • /
    • 제6권1호
    • /
    • pp.87-95
    • /
    • 1997
  • 금속염화물과 암모니아간의 가역반응을 이용한 화학열펌프는 비프레온계 냉동 냉장시스템으로서 환경규약의 제한이 없고 가스, 전기 및 산업폐열 등 다양한 구동열원을 사용할수 있으며 축열에 의한 에너지 저장이나 산업공정에서의 대용량 에너지관리 시스템 등 응용분야가 다양한 장점을 갖고 있다. 통상 소규모의 실험실 장치에서 파일롯트 플랜트(pilot plant)로 전환하는 과정에서 시스템의 성능에 대한 해석이 필요하며 화학반응기의 거동에 대한 컴퓨터 모사도 필수적이다. 따라서 본 연구에서는 작동조건에 따라 화학식 냉동기 성능계수가 어떻게 변하는지를 예측하였고 반응기 모델링에 의한 동적모사를 수행하여 반응기의 온도거동, 작동조건에 따른 전화율 변화, 반응혼합물의 제조변수가 냉동기 성능에 미치는 영향 등을 고찰하였다.

  • PDF

마이크로가스터빈 배열부하가 배가스흡수식 냉온수기의 성능에 미치는 영향 (Effect of the Exhaust Heat from Micro Gas Turbine on the Performance Characteristics of the Absorption Chiller)

  • 최경식;손화승;김형식;임상규;허광범
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.158-162
    • /
    • 2006
  • Micro gas turbine (MGT) has received attention recently as a small-scale distributed power source. Due to many advantages such as their small size, low maintenance cost and minimal vibrations during operation, they are expected to become widespread in a wide range of applications. The exhaust heat emitted by the MGT is in the form of an exhaust gas that is about $270^{\circ}C$ which is an extremely clean gas. Korea Gas Corporation (KOGAS) has researched performance characteristics of a cogeneration system combining 28kW class MGT and 13 USRT class absorption hot and chilled water generator in the local condition. The present results of this study can be summarized as follows: (1) in heating mode, the total efficiency of cogen. system is about $65\%$ and heating capacity is 33kW at 25kW MGP power (2) in cooling mode, COP is about 0.6 at 22kW MGT power.