Development of EM Wave Absorber for Increasing Communication Range in RFID System (RFID 시스템의 통신 거리 증대를 위한 전파흡수체 개발)

  • Park, Soo-Hoon;Kim, Dong-Il;Yoon, Sang-Gil;Yoo, Gun-Suk;Jeong, In-Seong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.3
    • /
    • pp.222-229
    • /
    • 2009
  • In this paper, we designed and fabricated the EM wave absorbers for preventing the reduction of the communication range when RFID Tag is approached to a metal plate. The EM wave absorber samples were fabricated with difference composition ratios of Amorphous metal powder and CPE, the absorption abilities of which were simulated by substituting different thicknesses of the EM wave absorbers. Then the EM wave absorbers are manufactured based on the simulated results. By using the EM wave absorbers, we have confirmed the improvement effect of RFID tag antenna and the increase of communication range of RFID system. As a result, it was cleary shown that the communication range of RFID system is improved by adopting the EM wave absorber with the composition ratio of Amorphous metal powder:CPE=80:20 wt.% and the thickness of 4 mm. Thus, it was confirmed that the proposed EM wave absorber can increase the communication range of RFID system from 0.8 m to 5.2 m in UHF band.

Synthsis of $CuInSe_2$ nanoparticles and its application to the absorber layer for thin films solar cells ($CuInSe_2$ 나노 입자 합성 및 이를 이용한 광흡수층 박막 제조)

  • Kim, Kyun-Hwan;Ahn, Se-Jin;Yun, Jae-Ho;Gwak, Ji-Hye;Jo, A-Ra;Kim, Do-Jin;Yoon, Kyung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.396-396
    • /
    • 2009
  • Chalcopyrite semiconductor $CuInSe_2$ nanoparticles were prepared using a low temperature colloidal route by reacting the starting materials (CuI, $InI_3$ and $Na_2Se$) in solvents. After synthesised $CuInSe_2$ nanoparticles precursors were mixed with organic binder for the viscosity of the precursor slurry to be suitable for the doctor blade method. The mixture of $CuInSe_2$ and binder was deposited onto molybdenum-coated sodalime glass substrates to form thin film. The precursor thin films were preheated on the hot plate to remove remaining solvents and binder material. After subsequent thermal processing of the thin film under a selenium ambient, $CuInSe_2$ absorber layer with grain size significantly lager than that of the nanoparticles was formed.

  • PDF

Electromagnetic Wave Absorption Characteristics of Y-type Barium Ferrite Prepared by the Glass-ceramic Method

  • Miki, Hiroki;Hori, Chinatsu;Nagae, Masahiro;Yoshio, Tetsuo
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1179-1180
    • /
    • 2006
  • Y-type barium ferrite ($Ba_2Me_2Fe_{12}O_{22};$ Me=Zn, Co, Cu) expected as an electromagnetic wave absorber were prepared by the glass-ceramic method. The glasses with composition of $0.1ZnO{\cdot}0.9(xB_2O_3{\cdot}yBaO{\cdot}(1-x-y)Fe_2O_3)$ were prepared. Single-phase powders of Y type barium ferrite were obtained with the composition $0.1ZnO{\cdot}0.9(0.2B_2O_3{\cdot}0.5BaO{\cdot}0.3Fe_2O_3)$. The shape of Y-type crystals depended strongly on the heating temperature and changed from a plate-like hexagon to a complex polyhedron with increasing heating temperature. Correlation was recognized between saturation magnetization and crystal shape. Electromagnetic wave absorption characteristics was affected by the saturation magnetization and crystal shape.

  • PDF

Analysis of Heat Transfer of Thermal Storage Roof with the Air Circulation System (공기순환구조를 갖는 축열지붕의 열전달해석)

  • Shin, U.C.;Park, S.H.;Baek, N.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.33-42
    • /
    • 2001
  • The paper discusses the modelling of the thermal storage roof with the air circulation system. In this system, the fully glazed absorber plate is put on the top of the conventional pitch roof made of massive concrete and acts as a solar air heater. Solar radiation collected into absorber is stored in the roof structure by radiation and convection so that it reduces the nighttime heating load through the roof. Another part of the energy is also transmitted to internal air drawn into the channel and is then introduced Into the room. To analysis the system, the energy balance equations are developed and are solved using a finite difference method. The calculation results show a good agreement with the measured ones obtained from our experiments. From the results, it is seen that the thermal storage roof with the air circulation system reduces significantly the conductive heat loss compared with that for the conventional roof and has the instantaneous solar collection efficiency of about 30%.

  • PDF

Analytical p-version finite elements and application in analyses of structural collision protection

  • Zhu, B.;Chen, Y.M.;Leung, A.Y.T.
    • Structural Engineering and Mechanics
    • /
    • v.23 no.5
    • /
    • pp.487-504
    • /
    • 2006
  • Several new versatile two-dimensional p-version finite elements are developed. The element matrices are integrated analytically to guarantee the accuracy and monotonic convergence of the predicted solutions of the proposed p-version elements. The analysis results show that the convergence rate of the present elements is very fast with respect to the number of additional Fourier or polynomial terms in shape functions, and their solutions are much more accurate than those of the linear finite elements for the same number of degrees of freedom. Additionally, the new p-version plate elements without the reduced integration can overcome the shear locking problem over the conventional h-version elements. Using the proposed p-version elements with fast convergent characteristic, the elasto-plastic impact of the structure attached with the absorber is simulated. Good agreement between the simulated and experimental results verifies the present p-version finite elements for the analyses of structural dynamic responses and the structural elasto-plastic impact. Further, using the elasto-plastic impact model and the p-version finite element method, the absorber of the T structure on the Qiantang River is designed for its collision protection.

Development of Multistage Concentrating Solar Collector - I. Thermal performance of multistage cylindrical parabolique concentrating solar collector (다단이차원(多段二次元) 집광식(集光式) 태양열(太陽熱) 집열기(集熱器) 개발(開發)에 관(關)한 연구(硏究) - I. 다단이차원(多段二次元) 집광식(集光式) 태양열(太陽熱) 집열기(集熱器)의 열적(熱的) 성능분석(性能分析))

  • Song, Hyun-Kap
    • Solar Energy
    • /
    • v.6 no.2
    • /
    • pp.3-14
    • /
    • 1986
  • It is desirable to collect the solar thermal energy at relatively high temperature in order to minimize the size of thermal storage system and to enlarge the scope of solar thermal energy utilization. In this study, to develop a solar collector that has both advantages of collecting solar thermal energy at high temperature and fixing conveniently the collector system for long term period, a cylindrical parabolique concentrating solar collector (M.C.P.C.S.C) was designed, which has several rows of parabolique reflectors and thin thickness such as the flat-plate solar collector, maintaining the optical form of concentrating solar collector. The thermal performance of the M.C.P.C.S.C. newly designed in this study was analysed theoretically and experimentally. The results are summarized as follows: 1) prediction equation for outlet temperature, $T_o$, of heat transfer fluid and for the thermal efficiency, ${\eta}$, of the collector were derived as; o $$T_o=[C+B1_n(\frac{I_c(t)}{pv^3})]T_i$$ o $${\eta}=\frac{A}{A_c}\dot{m}[(C-1)+B1_n(E{\cdot}di^6\frac{I_c(t)}{\dot{m}^3})]\frac{T_i}{I_c(t)}$$ 2) When the insolation on the tilted solar collector surface, $I_c$, was $900-950W/m^2$ and the heat transfer fluid was not circulated in tubular absorber, the maximum temperature on the absorber surface was $100-118^{\circ}C$, this result suggested that the heat transfer fluid could be heated up to $98-116^{\circ}C$. The maximum temperature on the absorber surface was decreased with the increase of the collector shape factor, $L_p/L_w$ 3) There was a good agreement between the experimental and theoretical value of solar collector efficiency, ${\eta}$, which was proportional to the collector shape factor, $L_p/L_w$ 4) It is desirable to continue the study on the relationship between the collector shape factor, $L_p/L_w$, and the thermal efficiency of solar collector.

  • PDF

Window Integrated Solar Collectors (창호일체형 태양열 집열기)

  • Park, Seong-Bae;Lim, Seong-Whan;Park, Mann-Kwi
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.61-65
    • /
    • 2009
  • Window integrated solar collector is to simply install inside of the existing double glass window frame. Double glass window frame is consist of inner glass of Low-E coating and Silver coating, and outer glass of low iron reinforced glass. In order to secure natural lighting in a room, only 50% of window frame is covered with solar collectors. Solar absorption or transmission rate varies seasonally depending on sun angles. Part of inner glass where right behind of the solar plate is covered with silver coating to increase absorption rate of solar plate. The collector is made of a copper serpentine where aluminum fins are soldering. To improve the effect of insulation of inside of the window frame is recommend vacuum. As a result, we are making the 3th sample and will archieve below $F_RU_L=7.5W/m^2^{\circ}C$ that is the account of heat lossed, and above $F_R({\tau}{\alpha})=0.45$.

  • PDF

Wave Absorbing Characteristics of a Horizontal Submerged Punching Plate (수평형 타공판의 소파특성)

  • 조일형
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.14 no.4
    • /
    • pp.265-273
    • /
    • 2002
  • In this paper, wave absorbing characteristics of a horizontal submerged punching plate are investigated throughout the calculation and the experiment. The punching plate with the array of circular holes can force the flow to separate and to form eddies of high vorticity and cause significant energy loss. As an analytic tool, the linear water wave theory and the eigenfunction expansion method is applied. Darcy's law that the normal velocity of the fluid passing through the punching plate is linearly proportional to the pressure difference between two sides of the punching plate is assumed. The proportional constant called the porous coefficient is deeply dependent to the porosity. To obtain the relationship between the porosity and the porous coefficient the systematic model test for the punching plates with 6 different porosities is conducted at 2-dimensional wave tank. It is found that the porous coefficient is linearly proportional to the porosity(b=57.63P-0.9717). It is also noted that the optimal porosity value is near P=0.1 and the optimal range of submergence depth is $d/h\\leq0.2$ within entire frequency range.

Quality Changes of Aseptic Packaged Cooked Rice during Storage (무균포장밥의 저장중 품질 변화에 관한 연구)

  • Kum, Jun-Seok;Lee, Chang-Ho;Lee, Sang-Hyo;Lee, Hyun-Yu
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.449-457
    • /
    • 1995
  • Aseptic packaged cooked rice without oxygen absorber and EVOH material was not suitable for good quality during long storage at room temperature. Quality change of aseptic packaged cooked rice with OPP/EVOH/EPL(P-1), PET/EVOH/EPL(P-2) and OPP/EVOH/LLDPE(P-3) for lid material and FX and TSQ for oxygen absorber was observed during storage(60 days) at $20^{\circ}C,\;30^{\circ}C\;and\;40^{\circ}C$. To evaluate quality change of aseptic packaged cooked rice, water content, color, pH, acidity, hardness, and total plate count were measured periodically. The results showed that moisture content was decreased as storage time increased while storage temperature showed no significant effect. P-2 and FX combination had the lowest evaporation of water. L value was decreased as storage time increased while a value increased in all treatment. P-2 and FX combination had the best result for color value. Titratable acidity and pH of P-3 increased up to 20, 5.5, respectively at the end of storage while the other treatment showed no significant effect. Hardness of aseptic packaging of cooked rice was decreased as temperature of storage increased while lid materials and oxygen absorber types showed no significant effect. Result of total plate count showed that there was no detection for $20^{\circ}C\;and\;30^{\circ}C$ storage temp. while more than $1{\times}10^6\;CFU/g\;for\;40^{\circ}C$ storage temp. at the end of storage. In conclusion, aseptic packaged cooked rice could be stored and distributed for 6 month at room temp. and effect of lid materials on quality change of aseptic packaged cooked rice was more significant than oxygen absorber.

  • PDF

Research on an Optimal Trickling Surface of the Regenerator in a Solar Air-conditioning System (태양열 이용 냉난방 공조시스템중 재생기의 최적 재생면 구조에 관한 연구)

  • Kim, B.C.;Choi, K.H.;Kum, J.S.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.185-195
    • /
    • 1998
  • The high viscosity of a LiCl(lithium chloride) solution as an absorbent in a solar energy regenerator causes a channeling phenomenon on the solar powered absorber plate surface when the solution is trickling down for regenerating itself. As this channeling phenomenon affects badly the heat and mass transfer, it is pertinent that this phenomenon be studied. Since regenerating performance of the solar energy regenerator depends on how the solution uniformly flows on the plate surface, an experiment on the structure of the plate surface for a model regenerator was conducted. Various shapes and structures of the plat surface down which the LiCl solution trickled were tested, and it was found that a tiered surface showed the highest water evaporation rate leaving more potential energy concentrating LiCl on the plate. It was also observed that the water evaporation rate depended largely on the pitch and height of the disturbing rods. In addition, the wider the contact area is and the longer the solution's flow time, the better the solar energy regenerator's performance.

  • PDF