• Title/Summary/Keyword: Absolute measurement

Search Result 591, Processing Time 0.03 seconds

Fuel Concentration Measurements by Laser Rayleigh Scattering (레이저 Rayleigh 산란을 이용한 연료농도 계측시 잡음원인과 대책)

  • Kwon, Soon-Tae;Lee, Jae-Won;Park, Chan-Jun;Ohm, In-Young
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.189-197
    • /
    • 2008
  • In this study, a system to measure continuously the fuel concentration in a steady flow rig on the basis of Rayleigh scattering is presented. The system can be employed to measure both the temporal and the spatial distribution. Also, it is possible to calibrate the system for the measurement of accurate absolute concentration. Firstly, the system was tested at a calibration chamber for the determination of scattering cross section from propane, butane, acetylene, Freon-12 and Genetron 143a. After this, the system was adapted to a steady flow rig to measure the temporal and spatial fuel concentration. The rig is composed of cylinder head, intake manifold, injector, and transparent cylinder which can simulate internal combustion engine. To cope with the interference of Mie scattering, which is main obstacle of the measuring concentration with Rayleigh scattering, a hardware filter was installed for reducing the number density of particles. Furthermore a software filter was developed, which is based on the rise time and the time constant of the photomultiplier-amplifier system. In addition, background noisy was reduced by adjusting the optical array and applying the pin hall and beam trap. The results show that LRS can provide useful information about concentration field and the software filter is very effective method to remove Mie interference.

Signal-Averaged P Wave Analysis in Patients with Paroxysmal Atrial Fibrillation (발작성 심방세동 환자의 신호평균 P파 분석)

  • 김인영;이종연;이병채;이용희;이종민;김선일;김준수
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Atrial fibrillation(AF). chronic or paroxysmal is the most frequent arrhythmia in human subjects Duration of P wave in signal-averaged electrocardiography(SAECG) reflects intra-atrial conduction time and therefore. could be used as an electrophysiological marker for atrial conduction chance at the earthy stave. So we apply the analysis method using SAECG to diagnose Paroxysmal atrial fibrillation(PAF) . Subjects Participated for the study consisted of two groups: a control group(n=34) of normal healthy volunteers and a group of AF Patients(n=38) with a documented history of PAF but no other history of cardiac disease. We evaluated the effect of several filtering and determination methods to find the starting and ending feints of the P wavy on its duration. To increase the measurement reliability of P wave duration. the automatic detection method was proposed. Also. to increase the detection rate for PAF risk, the decision threshold value was optimized using receiver operation characteristics(ROC) curve. Results showed that the highest statistical difference (p〈0.001) of the P wane duration between controls and subjects was obtained at the Processing condition, using absolute threshold vague(8.75 $\mu N$) , a least mean square(LMS) high pass filter and 30 Hz cutoff frequency. The most outstanding difference(sensitivity 88 % specificity 64.4 %) between controls and subjects was obtained at the decision threshold value of 112 ms.

Effects of Changes in Exercise Intensity on Resting Metabolic Rate (RMR) and Energy Expenditure in Young Men (운동강도의 차이가 안정시대사량 및 에너지 소비량에 미치는 영향)

  • Kawk Yi-Sub;Jin Young-Wan;Park Chan-Ho
    • Journal of Life Science
    • /
    • v.15 no.3 s.70
    • /
    • pp.352-358
    • /
    • 2005
  • The purpose of this study was to examine the effect of various exercise intensity on Resting Metabolic Rate (RMR), excess post exercise energy expenditure (EPEE), and thyroid hormonal changes in trained (TR) and untrained (UT) people. The subject of the present study were divided into two groups and four periods: trained (TR; n=6) and untrained (UT; n=6) group. And the periods were divided as follows; Resting (R), Maximal (M), High intensity (H), and Low intensity (L). The percent body fat and RMR of all subjects were measured at every periods. The RMR was measured early in the morning following a 12-hour fast using MMX3B gas analyzer and blood sample were collected from the anticubital vein to investigate thyroid hormonal (T3, T4, Free T3, Free T4, & TSH) changes. All the RMR values were expressed as absolute value/BSA $(kcal/d/m^2)$. And We also analyzed mean energy expenditure for 30 minutes during and after different intensity exercise. There was significant difference in RMR among different intensity of exercise. in TR (p < .05) not in the UT group. however, there was no significant different percent body fat in TR and in UT group. In the energy expenditure, there was significant different between TR and UT in HEE (high intensity exercise energy expenditure), LEE (low intensity exercise energy expenditure), HEEPE (high intensity exercise energy expenditure post exercise) & LEEPE (low intensity exercise expenditure post exercise). In the hormonal level, there was significant different in T4 level in the TR group at H period and in T4, Free T3, & Free T4 levels in TR group at L period, however there was no significant different in the UT group. The present cross-sectional study was design to investigate the relationship between exercise intensity and RMR. The focus of this investigation was to compare RMR in aerobically trained (TR) and untrained (VI). The relationship among RMR, exercise intensity and percent body fat would best be investigated using MMX3B and body composition analyzer. Each subject completed measurement of percent body fat, RMR, hormone in the period of maximal oxygen uptake exercise (M), high intensity exercise (H), and low intensity exercise (L). From the results, Low intensity of exercise (L), there was a trend for an increased RMR (kcal/day) in the TR not for the UT. This is best explained not by the reduced percent body fat but by the highly induced energy expenditure (during exercise and post exercise energy expenditure) and increased T4, Free T3, and Free T4 hormonal levels in the low intensity exercise for the TR group.

A Cytotoxicity of Carrier Oil and Essential Oils on Cells by Using of Aromatherapy (향기요법에 사용하는 캐리어 오일과 에션셜 오일의 세포에 대한 독성)

  • Yu, Byong-Soo;Kim, Sha-Sha;Yun, Young-Han;Kim, Ki-Young
    • Korean Journal of Human Ecology
    • /
    • v.17 no.5
    • /
    • pp.1027-1035
    • /
    • 2008
  • Essentail oils and carrier oils are generally used for Aromatherapy. Therefore the toxicity, possibilities of irritations and sensitive reactions and injury of essential oils must be considered for clients and therapists. So that, in this studies a toxicity of jojoba and 4 species essential oils (fennel, mandarine, tea tree and cedarwood) were investigated by the measurement of MTT-assay and sirius red staining. Liver, kidney and brain tell were chosen for the cell viability assay and observation of morphological change. In the result, no cytotoxicity was observed on live., kidney and brain cell at concentration of 0.01 $\mu\el/m\el$ jojoba oil. And lysis and nucleus breaking were not observed at same concentration of jojoba oil on live., kidney and brain cell. fennel oil was showed 50% of cell viability and inhibited cell growth on liver, kidney and brain cell at relatively high concentration compared with the other oils. 50% of liver, kidney and brain cell viability and delayed cell growth of tea tree and mandarine oil were revealed at lower concentration than fennel oil. In cedarwood oil, 50% of liver cell viability at concentration of 0.00067 $\mu\el/m\el$ was showed, but cell viability and cell growth of kidney and beam cell were effected at the lowest concentration compared with other oils. So that, jojoba oil as using of carrier oil may be not harmful. And 3 essential oils from the fennel, tea tree and mamdarine may have very low toxicity, but cedarwood may be used carefully for inhalation. And over dosage of concentrated cedarwood oil should be not directly touched and exposured, and absolute essential oils must be diluted with carrier oils for topical and systematic massage.

A Preliminary Development of Real-Time Hardware-in-the-Loop Simulation Testbed for the Satellite Formation Flying Navigation and Orbit Control (편대비행위성의 항법 및 궤도제어를 위한 실시간 Hardware-In-the-Loop 시뮬레이션 테스트베드 초기 설계)

  • Park, Jae-Ik;Park, Han-Earl;Shim, Sun-Hwa;Park, Sang-Young;Choi, Kyu-Hong
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.1
    • /
    • pp.99-110
    • /
    • 2009
  • The main purpose of the current research is to developments a real-time Hardware In-the-Loop (HIL) simulation testbed for the satellite formation flying navigation and orbit control. The HIL simulation testbed is integrated for demonstrations and evaluations of navigation and orbit control algorithms. The HIL simulation testbed is composed of Environment computer, GPS simulator, Flight computer and Visualization computer system. GPS measurements are generated by a SPIRENT GSS6560 multi-channel RF simulator to produce pseudorange, carrier phase measurements. The measurement date are transferred to Satrec Intiative space borne GPS receiver and exchanged by the flight computer system and subsequently processed in a navigation filter to generate relative or absolute state estimates. These results are fed into control algorithm to generate orbit controls required to maintain the formation. These maneuvers are informed to environment computer system to build a close simulation loop. In this paper, the overall design of the HIL simulation testbed for the satellite formation flying navigation and control is presented. Each component of the testbed is then described. Finally, a LEO formation navigation and control simulation is demonstrated by using virtual scenario.

Near-Infrared Imaging Spectrometer onboard NEXTSat-1

  • Jeong, Woong-Seob;Lee, Dae Hee;Moon, Bongkon;Park, Kwijong;Park, Sung-Joon;Pyo, Jeonghyun;Park, Youngsik;Kim, Il-Joong;Park, Won-Kee;Kim, Mingyu;Lee, Duk-Hang;Nam, Ukwon;Han, Wonyong;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.70.1-70.1
    • /
    • 2013
  • New space program for "Next-Generation Small Satellite (NEXTSat)" launched last year after the success of the series of Science & Technology Satellite (STSAT). KASI proposed the near-infrared imaging spectrometer as a scientific payload onboard NEXTSat-1. It was selected as one of two scientific payloads. The approved scientific payload is the near-infrared imaging spectrometer for the study of star formation history (NISS). The efficient near-infrared observation can be performed in space by evading the atmospheric emission as well as other thermal noise. The observation of cosmic near-infrared background enables us to reveal the early Universe in an indirect way through the measurement of absolute brightness and spatial fluctuation. The detection of near-infrared spectral lines in nearby galaxies, cluster of galaxies and star forming regions give us less biased information on the star formation. In addition, the NISS will be expected to demonstrate our technologies related to the development of the Korea's leading near-infrared instrument for the future large infrared telescope, SPICA.

  • PDF

Quantitative Analysis of Tooth Mineral Content by High Resolution Micro-computed Tomography

  • Song, Dae-Sung;Kim, Jung-Woo;Hwang, Hee-Su;Oh, Sin-Hye;Song, Ju Han;Kim, Il-Shin;Hwang, Yun-Chan;Koh, Jeong-Tae
    • International Journal of Oral Biology
    • /
    • v.42 no.4
    • /
    • pp.155-161
    • /
    • 2017
  • Teeth and bones are highly mineralized tissues containing inorganic minerals such as calcium phosphate, and a growing number of evidences show that their mineral content is associated with many diseases. Although the quantification of mineral contents by micro-computed tomography(micro- CT) has been used in diagnosis and evaluation for treating bone diseases, its application for teeth diseases has not been well established. In this study, we attempted to estimate a usefulness of a high-resolution micro-CT in analysis of human teeth. The teeth were scanned by using the Skyscan 1172 micro-CT. In order to measure tooth mineral content, beam hardening effect of the machine was corrected with a radiopaque iodine-containing substance, iodoacetamide. Under the maximum resolution of $6.6{\mu}m$, X-ray densities in teeth and hydroxyapatite standards were obtained with Hounsfield unit (HU), and they were then converted to an absolute mineral concentration by a CT Analyzer software. In enamel layer of cusp area, the mean mineral concentration was about $2.14mg/mm^3$ and there was a constant mineral concentration gradient from the enamel surface to the dentinoenamel junction. In the dentin of middle 1/3 of tooth, the mean mineral concentration was approximately $1.27mg/mm^3$ and there was a constant mineral concentration gradient from the outer of root to the pulp side, ranging from 1.3 to $1.06mg/mm^3$. In decay region of dentin, the mineral content was gradually decreased from the intact inner side to the decayed surface. These results suggest that high-resolution micro-CT can be as a useful tool for non-invasive measurement of mineral concentration in teeth.

A Study on Nutritional Management for Improvement of Exercise Capacity and Physical Fitness -For Dietary Feeding Condition- (운동 수행 능력 및 체력증진을 위한 효율적 영양관리에 관한 연구 -식이급식 조건에 대하여-)

  • 오승호;김유섭;강정채
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.20 no.2
    • /
    • pp.94-102
    • /
    • 1991
  • This study was directed to further clarify the effect of resting time or dietary condition for the improvement of exercise capacity and physical fitness, and the changes of some body consitiuents and physiological functions which are related to the exercise metabolism. Sixteen male students(8 athletes and 8 nonathletes)were participated during 3 weeks(Aug. 20-Sep.9, 1989). Each subject performed two treadmill running trials at an absolute intensity (1 mintute in 3.4mph/15% slope and 2 minutes in 5.5mph/20% slope). In the resting time trials, general diet was fed before 1, 2, 4 and 12 hours of the treadmill exercise loaded. in the dietary condition trials, high carbohydrate(HC), high fat(HF) and high protein(HP) diet were fed before 2 hours of the treadmill exercise loaded. Control trial was that of resting time before treadmill exercise loaded after 12 hours of general diet feeding. Measurement were made to study the change of blood glucose, palmitate, lactate, blood pressure and heart rate. The results obtained are summarized as follows: Mean daily metabolizable period. In resting time trial, the blood glucose concentration of athlete and nonathlete from 2 hours group was similar to control group. The blood palmitate concentration of athlete was increased in 1 and 2 hours group but those of nonathlete was not only increased in 1 and2 hours group but was more increased in 12 hours group, compared with both control group. The blood lactate concentration was increased in all experimental group, compared with both control group and those of nonathlete was much higher than athlets. The elevation rate of blood pressure in pre-and after-exercise of athlete was lower than those of nonathlete. In dietary composition trial, the blood glucose concentration of athlete and nonathlete in HC group was higher than other diet groups. The blood lactate concentration of athlete and nonathlete in HC group was lower than other diet groups. There was no remarkable change of the blood palmitate concentration and heart rate in each dietary composition trial, but those of nonathlete was low in HC and high in HP group. In above results, it was suggested that the effective condition of resting time and dietary composition for the improvement of exercise capacity of nonathlete may be 2 hours and HC diet, respectively. But it was showed that the exercise capacity of athlete may not be affected by experimental condition of resting time, except 1 hour after feeding or of dietary composition because of well adaptation in new exercise condition.

  • PDF

Critics on Ludwig Boltzmann's Methodology of Science (루드빅 볼츠만의 과학 방법론에 대한 역사-비판적 검토)

  • Moun, Jean-sou;Lee, Woo-buong
    • Journal of Korean Philosophical Society
    • /
    • v.117
    • /
    • pp.57-84
    • /
    • 2011
  • As for the methodology of physical science, on the one side, Ludwig Boltzmann was declined to Scientific Realist and at the same time Epistemological Idealist. But on the other. He was neither fully nor consistently either one of them, because of rejecting the causal realism of the former and the belief in absolute certainty of the latter. Is there nevertheless any evidence that he had a coherent world view of his own? Yes. In short, he seems to identify his own position with what is called a mind-matter identity theory. In 1897, he supported that psychological processes are identical with certain processes in the brain(realism). And in 1903, he said : "Physics is not separated from psychology. They are only different sides." But Boltzmann did not explain concretely the possibility of this identity. So I tried to construct one theory of identity which is suitable for understanding problems n the physical world, though whether it would work for a full-scale world view which includes both physical and mental phenomena remains problematic. If light phenomena, for example, tend to be measured in terms of some contexts as if light were a wave and in others as if light were a particle, then one may be able to reasonably suppose that light has whatever characteristics in itself which it must have in order to seem like a wave under some conditions of measurement and like a particle in others. If this theory is provisionally to mental phenomena as well, it would mean that reality has those characteristics in itself which it must have to appear as it does to the various faculties of the mind and as it is measured in different physical situations. This is probably not what Boltzmann meant by his theory of identity, since it is very ontological and metaphysical. But in my opinion it is by far the most reasonable identity theory.

Analyzing the Significance of T1 Slope minus Cervical Lordosis in Patients with Anterior Cervical Discectomy and Fusion Surgery

  • Lee, Ho Jin;You, Soon Tae;Sung, Jae Hoon;Kim, Il Sup;Hong, Jae Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.913-921
    • /
    • 2021
  • Objective : Accurate measurement of T1 slope (a component of T1s minus cervical lordosis [CL]) is often constrained by anatomical limitations. In this situation, efforts should be made to find the exact meaning of T1s-CL and whether there are any alternatives to it. Methods : We enrolled 117 patients who received two-level anterior cervical discectomy and fusion (ACDF). Occipital slope, C2 slope (C2s), C7 slope (C7s), T1, O-C2 angle (O-C2A), C2-7 angle (C2-7A), O-C7 angle (O-C7A), T1s-CL, C7-T1 angle (C7-T1A), and C2-7 sagittal vertical axis were measured. We determined 16° (T1s-CL) as the reference point for dividing subjects into the mismatch group and the balance group, and a comparative analysis was performed. Results : The mean value of C7-T1A was constantly maintained within 2.6° peri-operatively. In addition, C2s and T1s-CL showed the same absolute change (Δ|0.8|°). The mean values of T1s-CL of the mismatch and balance groups were 23.0° and 7.6°, respectively. The five factors with the largest differences between the two groups were as follows : C2s (Δ13.3°), T1s-CL (Δ15.4°), O-C2A (Δ8.7°), C2-7A (Δ14.7°), and segmental angle (Δ7.9°) before surgery. Only four factors showed statistically significant change between the two groups after ACDF : T1s-CL (Δ4.0° vs. Δ0.2°), C2s (Δ3.2° vs. Δ0.7°), O-C2A (Δ2.6° vs. Δ1.3°), C2-7A (Δ6.3° vs. Δ1.3°). A very strong correlation between T1s-CL and C2s was also found (r=|0.88-0.96|). Conclusion : C2s itself may be the essential key to represent T1s-CL. The amounts and directions of change of these two factors (T1s-CL and C2s) were also almost identical. The above phenomenon was re-confirmed once again through the correlation analysis.